Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
Int J Comput Assist Radiol Surg ; 19(3): 591-599, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37523011

RESUMO

PURPOSE: The aim of the study was to assess the deviation between clinical implant axes (CIA) determined by a surgeon during preoperative planning and reconstructed tooth axes (RTA) of missing teeth which were automatically computed by a previously introduced anatomical SSM. METHODS: For this purpose all available planning datasets of single-implant cases of our clinic, which were planned with coDiagnostix Version 9.9 between 2018 and 2021, were collected for retrospective investigation. Informed consent was obtained. First, the intraoral scans of implant patients were annotated and subsequently analyzed using the SSM. The RTA, computed by the SSM, was then projected into the preoperative planning dataset. The amount and direction of spatial deviation between RTA and CIA were then measured. RESULTS: Thirty-five patients were implemented. The mean distance between the occlusal entry point of anterior and posterior implants and the RTA was 0.99 mm ± 0.78 mm and 1.19 mm ± 0.55, respectively. The mean angular deviation between the CIA of anterior and posterior implants and the RTA was 12.4° ± 3.85° and 5.27° ± 2.97° respectively. The deviations in anterior implant cases were systematic and could be corrected by computing a modified RTA (mRTA) with decreased deviations (0.99 mm ± 0.84 and 4.62° ± 1.95°). The safety distances of implants set along the (m)RTA to neighboring teeth were maintained in 30 of 35 cases. CONCLUSION: The RTA estimated by the SSM revealed to be a viable implant axis for most of the posterior implant cases. As there are natural differences between the anatomical tooth axis and a desirable implant axis, modifications were necessary to correct the deviations which occurred in anterior implant cases. However, the presented approach is not applicable for clinical use and always requires manual optimization by the planning surgeon.


Assuntos
Implantes Dentários , Cirurgia Assistida por Computador , Dente , Humanos , Tomografia Computadorizada de Feixe Cônico , Estudos Retrospectivos , Próteses e Implantes , Desenho Assistido por Computador , Imageamento Tridimensional
3.
Dentomaxillofac Radiol ; 52(6): 20230059, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37427585

RESUMO

OBJECTIVES: This study evaluated the accuracy of deep neural patchworks (DNPs), a deep learning-based segmentation framework, for automated identification of 60 cephalometric landmarks (bone-, soft tissue- and tooth-landmarks) on CT scans. The aim was to determine whether DNP could be used for routine three-dimensional cephalometric analysis in diagnostics and treatment planning in orthognathic surgery and orthodontics. METHODS: Full skull CT scans of 30 adult patients (18 female, 12 male, mean age 35.6 years) were randomly divided into a training and test data set (each n = 15). Clinician A annotated 60 landmarks in all 30 CT scans. Clinician B annotated 60 landmarks in the test data set only. The DNP was trained using spherical segmentations of the adjacent tissue for each landmark. Automated landmark predictions in the separate test data set were created by calculating the center of mass of the predictions. The accuracy of the method was evaluated by comparing these annotations to the manual annotations. RESULTS: The DNP was successfully trained to identify all 60 landmarks. The mean error of our method was 1.94 mm (SD 1.45 mm) compared to a mean error of 1.32 mm (SD 1.08 mm) for manual annotations. The minimum error was found for landmarks ANS 1.11 mm, SN 1.2 mm, and CP_R 1.25 mm. CONCLUSION: The DNP-algorithm was able to accurately identify cephalometric landmarks with mean errors <2 mm. This method could improve the workflow of cephalometric analysis in orthodontics and orthognathic surgery. Low training requirements while still accomplishing high precision make this method particularly promising for clinical use.


Assuntos
Pontos de Referência Anatômicos , Crânio , Adulto , Humanos , Masculino , Feminino , Reprodutibilidade dos Testes , Cefalometria/métodos , Crânio/diagnóstico por imagem , Algoritmos
4.
Head Neck ; 44(12): 2810-2819, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36114764

RESUMO

BACKGROUND: This study evaluated the accuracy of computer-assisted surgery (CAS)-driven DCIA (deep circumflex iliac artery) flap mandibular reconstruction by traditional morphometric methods and geometric morphometric methods (GMM). METHODS: Reconstruction accuracy was evaluated by measuring distances and angles between bilateral anatomical landmarks. Additionally, the average length of displacements vectors between landmarks was computed to evaluate factors assumed to influence reconstruction accuracy. Principal component analysis (PCA) was applied to unveil main modes of dislocation. RESULTS: High reconstruction accuracy could be demonstrated for a sample consisting of 26 patients. The effect of the number of segments and length of defect on reconstruction accuracy were close to the commonly used significance threshold (p = 0.062/0.060). PCA demonstrated displacement to result mainly from sagittal and transversal shifts. CONCLUSIONS: CAS is a viable approach to achieve high accuracy in mandibular reconstruction and GMM can facilitate the evaluation of factors influencing reconstruction accuracy and unveil main modes of dislocation in this context.


Assuntos
Retalhos de Tecido Biológico , Reconstrução Mandibular , Procedimentos de Cirurgia Plástica , Cirurgia Assistida por Computador , Humanos , Reconstrução Mandibular/métodos , Artéria Ilíaca/cirurgia , Retalhos Cirúrgicos/irrigação sanguínea , Computadores , Procedimentos de Cirurgia Plástica/métodos , Retalhos de Tecido Biológico/cirurgia
5.
Bone Rep ; 17: 101611, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36120645

RESUMO

Purpose: Morphological variability of the skull is an important consideration for cranioplasty and implant design. Differences in morphology of the skull based on the ethnicity are known. In a previous study we could show the accuracy and benefits of virtual reconstructions based on a statistical shape model (SSM) for neurocranial defects. As the SSM is trained on European data, the question arises how well this model fares when dealing with patients with a different ethnic background. In this study we aim to evaluate the accuracy and applicability of our proposed method when deploying a cranial SSM generated from European data to estimate missing parts of the neurocranium in a Chinese population. Methods: We used the same data and methods as in our previous study and compared the outcomes when applied to Chinese individuals. A large unilateral defect on the right side and a bilateral defect were created. The outer surface of the cranial table was reconstructed from CT scans, meshed with triangular elements, and registered to a template. Principal component analysis together with Thin Plate Spines (TPS) deformation was applied to quantify modes of variation. The mesh to mesh distances between the original defects´ surfaces and the reconstructed surface were computed. Results: Comparing the Chinese test group with the European control group, regarding the entire defect the analysis shows no significant difference for unilateral defects (test vs. control group/0.46 mm ± vs. 0.44 mm). Reconstruction of bilateral defects exhibited only in slightly higher prediction errors than those of unilateral defects (0.49 mm ± vs. 0.45 mm). Conclusion: The proposed method shows a high accuracy that seems to be ethnical independent - with low error margins for virtual skull reconstruction and implant design.Clinical relevance: Metallic objects may severely impact image quality in several CBCT devices.

6.
Int J Comput Assist Radiol Surg ; 17(10): 1957-1968, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35902422

RESUMO

PURPOSE: Modern virtual implant planning is a time-consuming procedure, requiring a careful assessment of prosthetic and anatomical factors within a three-dimensional dataset. In order to facilitate the planning process and provide additional information, this study examines a statistical shape model (SSM) to compute the course of dental roots based on a surface scan. MATERIAL AND METHODS: Plaster models of orthognathic patients were scanned and superimposed with three-dimensional data of a cone-beam computer tomography (CBCT). Based on the open-source software "R", including the packages Morpho, mesheR, Rvcg and RvtkStatismo, an SSM was generated to estimate the tooth axes. The accuracy of the calculated tooth axes was determined using a leave-one-out cross-validation. The deviation of tooth axis prediction in terms of angle or horizontal shift is described with mean and standard deviation. The planning dataset of an implant surgery patient was additionally analyzed using the SSM. RESULTS: 71 datasets were included in this study. The mean angle between the estimated tooth-axis and the actual tooth-axis was 7.5 ± 4.3° in the upper jaw and 6.7 ± 3.8° in the lower jaw. The horizontal deviation between the tooth axis and estimated axis was 1.3 ± 0.8 mm close to the cementoenamel junction, and 0.7 ± 0.5 mm in the apical third of the root. Results for models with one missing tooth did not differ significantly. In the clinical dataset, the SSM could give a reasonable aid for implant positioning. CONCLUSIONS: With the presented SSM, the approximate course of dental roots can be predicted based on a surface scan. There was no difference in predicting the tooth axis of existent or missing teeth. In clinical context, the estimation of tooth axes of missing teeth could serve as a reference for implant positioning. However, a higher number of training data must be achieved to obtain increasing accuracy.


Assuntos
Implantes Dentários , Cirurgia Assistida por Computador , Desenho Assistido por Computador , Tomografia Computadorizada de Feixe Cônico/métodos , Estudos de Viabilidade , Humanos , Imageamento Tridimensional , Mandíbula , Maxila , Cirurgia Assistida por Computador/métodos
7.
J Clin Med ; 11(9)2022 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-35566508

RESUMO

Adequate soft-tissue dimensions have been shown to be crucial for the long-term success of dental implants. To date, there is evidence that placement of dental implants should only be conducted in an area covered with attached gingiva. Modern implant planning software does not visualize soft-tissue dimensions. This study aims to calculate the course of the mucogingival borderline (MG-BL) using statistical shape models (SSM). Visualization of the MG-BL allows the practitioner to consider the soft tissue supply during implant planning. To deploy an SSM of the MG-BL, healthy individuals were examined and the intra-oral anatomy was captured using an intra-oral scanner (IOS). The empirical anatomical data was superimposed and analyzed by principal component analysis. Using a Leave-One-Out Cross Validation (LOOCV), the prediction of the SSM was compared with the original anatomy extracted from IOS. The median error for MG-BL reconstruction was 1.06 mm (0.49-2.15 mm) and 0.81 mm (0.38-1.54 mm) for the maxilla and mandible, respectively. While this method forgoes any technical work or additional patient examination, it represents an effective and digital method for the depiction of soft-tissue dimensions. To achieve clinical applicability, a higher number of datasets has to be implemented in the SSM.

9.
Int J Comput Dent ; 25(4): 349-359, 2022 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-35072424

RESUMO

PURPOSE: Creating wax-ups of missing teeth for backward planning in implant surgery is a complex and time-consuming process. To facilitate implant-planning procedures, the automatic generation of a virtual wax-up would be useful. In the present study, the reconstruction of missing teeth in partially edentulous patients was performed automatically using newly developed software. The accuracy was investigated in order to test its clinical applicability. MATERIALS AND METHODS: This study presents a new method for creating an automatic virtual wax-up, which could serve as a basic tool in modern implant-planning procedures. First, a statistical shape model (SSM) based on 76 maxillary and mandibular arch scans from dentally healthy individuals was generated. Then, artificially generated tooth gaps were reconstructed. The accuracy of the workflow was evaluated on a separate testing sample of 10 individuals with artificially created tooth gaps given as a median deviation, in millimeters. Scans of three clinical cases with partial edentulism were equally reconstructed using the SSM and compared with the final prosthodontic work. RESULTS: The reconstruction of the artificial tooth gaps could be performed with the following median reconstruction accuracy: gap 21 with 0.15 mm; gap 27 with 0.20 mm; gap 34 with 0.22 mm: gap 36 with 0.22 mm; gaps 12 to 22 with 0.22 mm; gaps 34 to 36 with 0.22 mm. A scenario for an almost edentulous mandible with all teeth missing except teeth 33 and 43 could be reconstructed with a median reconstruction accuracy of 0.37 mm. The median tooth gap deviation of the SSM-based reconstruction in clinical cases differed from the final inserted prosthodontic teeth by 0.49 to 0.86 mm in median. CONCLUSION: A first feasibility of creating virtual wax-ups using an SSM could be shown. Artificially generated tooth gaps could be reconstructed close to the original with the proposed workflow. In the clinical cases, the SSM proposes an anatomical reconstruction, which does not yet consider prosthodontic aspects. To obtain clinical use, contact with antagonist teeth must be considered and more training data must be implemented. However, the presented method offers a fast and viable way for the approximate placement of missing crowns. This could be used in a digital planning workflow when implant position must be determined. (Int J Comput Dent 2022;25(4):349-0; doi: 10.3290/j.ijcd.b2599407).


Assuntos
Implantes Dentários , Boca Edêntula , Humanos , Prostodontia , Modelos Estatísticos , Coroas
10.
J Prosthet Dent ; 128(6): 1303-1309, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33902891

RESUMO

STATEMENT OF PROBLEM: The accuracy of intraoral scanners is a prerequisite for the fabrication of dental restorations in computer-aided design and computer-aided manufacturing (CAD-CAM) dentistry. While the precision of intraoral scanners has been investigated in vitro, clinical data on the accuracy of intraoral scanning (IOS) are limited. PURPOSE: The purpose of this clinical study was to determine the accuracy of intraoral scanning with different devices compared with extraoral scanning. MATERIAL AND METHODS: An experimental appliance was fabricated for 11 participants and then scanned intraorally and extraorally with 3 different intraoral scanners and a reference scanner. Intraoral and extraoral scans were subdivided into complete-arch and short-span scans and compared with the reference scan to assess trueness. Repeated scans in each group were assessed for precision. RESULTS: Precision and trueness were higher for extraoral scans compared with intraoral scans, except for complete-arch scans with 1 intraoral scanner. The median precision of short-span scans was higher (extraoral: 22 to 29 µm, intraoral: 23 to 43 µm) compared with complete-arch scans (extraoral: 81 to 165 µm, intraoral: 80 to 198 µm). The median trueness of short-span scans (extraoral: 28 to 40 µm, intraoral: 38 to 47 µm) was higher than that of complete-arch scans (extraoral: 118 to 581 µm, intraoral: 147 to 433 µm) for intraoral and extraoral scanning. CONCLUSIONS: Intraoral conditions negatively influenced the accuracy of the scanning devices, which was also reduced for the complete-arch scans.


Assuntos
Técnica de Moldagem Odontológica , Modelos Dentários , Humanos , Imageamento Tridimensional , Desenho Assistido por Computador , Arco Dental
11.
J Anat ; 240(2): 323-329, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34658032

RESUMO

PURPOSE: The current standard in reconstructing defects of the orbital floor, by using the concept of mirroring, is time-consuming and ignores the natural asymmetry of the skull. By using a statistical shape model (SSM), the reconstruction can be automatized and improved in accuracy. The present study aims to show the possibilities of the virtual reconstruction of artificial defects of the orbital floor using an SSM and its potentials for clinical implementation. METHODS: Based on 131 unaffected CT scans of the midface, an SSM was created which contained the shape variability of the orbital floor. Nineteen midface CT scans, that were not included in the SSM, were manually segmented to establish ground truth (control group). Then artificial defects of larger and smaller sizes were created and reconstructed using SSM (Group I) and the gold standard of mirroring (Group II). Eventually, a comparison to the surface of the manual segmentation (control group) was performed. RESULTS: The proposed method of reconstruction using an SSM leads to more precise reconstruction results, compared with the conventional method of mirroring. Whereas mirroring led to the reconstruction errors of 0.7 mm for small defects and 0.73 mm for large defects, reconstruction using SSM led to deviations of 0.26 mm (small defect) and, respectively, 0.34 mm (large defect). CONCLUSIONS: The presented approach is an effective and accurate method for reconstructing the orbital floor. In connection with modern computer-aided design and manufacturing, individual patient-specific implants could be produced according to SSM-based reconstructions and could replace current methods using manual bending techniques. By acknowledging the natural asymmetry of the human skull, the SSM-based approach achieves higher accuracy in reconstructing injured orbits.


Assuntos
Órbita , Procedimentos de Cirurgia Plástica , Humanos , Modelos Estatísticos , Órbita/diagnóstico por imagem , Órbita/cirurgia , Crânio , Tomografia Computadorizada por Raios X/métodos
12.
J Clin Med ; 10(24)2021 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-34945272

RESUMO

PURPOSE: The known preformed osteosynthesis plates for the midface are helpful tools for a precise and fast fixation of repositioned fractures. The purpose of the current study is to analyze the precision of newly developed prototypes of preformed osteosynthesis plates for the mandible. METHODS: Four newly designed preformed osteosynthesis plates, generated by a statistical shape model based on 115 CT scans, were virtually analyzed. The used plates were designed for symphyseal, parasymphyseal, angle, and condyle fractures. Each type of plate has three different sizes. For analysis, the shortest distance between the plate and the bone surface was measured, and the sum of the plate-to-bone distances over the whole surface was calculated. RESULTS: A distance between plate and bone of less than 1.5 mm was defined as sufficient fitting. The plate for symphyseal fractures showed good fitting in 90% of the cases for size M, and in 84% for size L. For parasymphyseal fractures, size S fits in 80%, size M in 68%, and size L in 65% of the cases. Angle fractures with their specific plate show good fitting for size S in 53%, size M in 60%, and size L in 47%. The preformed plate for the condyle part fits for size S in 75%, for size M in 85%, and for size L in 74% of the cases. CONCLUSION: The newly developed mandible plates show sufficient clinical fitting to ensure adequate fracture reduction and fixation.

13.
Head Face Med ; 17(1): 44, 2021 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-34670566

RESUMO

BACKGROUND: Complex bilateral midface fractures necessitate a surgically challenging procedure to preserve or restore the occlusion and the sensitive eye area. In this case control study, we aim to show the potential of a statistical shape model (SSM) for measuring the quality of the midface reconstruction, compared to the estimated preoperative situation. METHODS: An individualized SSM was postoperatively registered on 19 reconstructed complex bilateral midface fractures. Using this SSM, the distances from the simulated preoperative situation to the postoperative positions of the fracture segments were calculated. The fracture lines for Le Fort II, Le Fort III, and NOE fractures were chosen as reference points for the distance measurements. RESULTS: The SSM could be registered on all 19 complex bilateral midface fractures. All analyzed fractures showed a dorsal impaction (negative values) of the midface. Le Fort II fractures showed deviation values of -0.98 ± 4.6 mm, Le Fort III fractures showed values of -3.68 ± 3.6 mm, NOE type 2 fractures showed values of -0.25 ± 4.6 mm, and NOE type 1 fractures showed values of -0.25 ± 4.6 mm. CONCLUSIONS: The SSM can be used to measure the quality of the achieved reduction of complex bilateral midface fractures based on the estimated preoperative situation. TRIAL REGISTRATION: DRKS00009719.


Assuntos
Traumatismos Faciais , Estudos de Casos e Controles , Traumatismos Faciais/cirurgia , Humanos , Qualidade da Assistência à Saúde
14.
Sci Rep ; 11(1): 19347, 2021 09 29.
Artigo em Inglês | MEDLINE | ID: mdl-34588584

RESUMO

The ongoing COVID-19 pandemic has revealed alarming shortages of personal protective equipment for frontline healthcare professionals and the general public. Therefore, a 3D-printable mask frame was developed, and its air seal performance was evaluated and compared. Personalized masks (PM) based on individual face scans (n = 8) and a statistically shaped mask (SSM) based on a standardized facial soft tissue shape computed from 190 face scans were designed. Subsequently, the masks were additively manufactured, and in a second step, the PM and SSM were compared to surgical masks (SM) and FFP2 masks (FFP2) in terms of air seal performance. 3D-printed face models allowed for air leakage evaluation by measuring the pressure inside the mask in sealed and unsealed conditions during a breathing simulation. The PM demonstrated the lowest leak flow (p < 0.01) of inspired or expired unfiltered air of approximately 10.4 ± 16.4%, whereas the SM showed the highest (p < 0.01) leakage with 84.9 ± 7.7%. The FFP2 and SSM had similar values of 34.9 ± 18.5% leakage (p > 0.68). The developed framework allows for the time- and resource-efficient, on-demand, and in-house production of masks. For the best seal performance, an individually personalized mask design might be recommended.


Assuntos
COVID-19 , Máscaras , Equipamento de Proteção Individual , Biometria , Desenho de Equipamento , Pessoal de Saúde , Humanos , Impressão Tridimensional , Saúde Pública
15.
Am J Phys Anthropol ; 174(1): 3-19, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32935864

RESUMO

OBJECTIVES: Warfare is assumed to be one of the defining cultural characteristics of steppe nomads in Eastern Eurasia. For the first-centuries CE, a period of political turmoil in Northern China and Southern Siberia, relatively few data are, however, available about the degree and variability of violence in these communities. Here, we provide new data on violence among steppe nomads during the first-centuries CE by analyzing the type, anatomical distribution, and demographic distribution of perimortem trauma at Tunnug1 (Tuva, Southern Siberia-second to fourth c. CE). MATERIALS AND METHODS: Perimortem traumas were assessed on 87 individuals representing both sexes and different age classes. The timing of the lesions was assessed based on morphological criteria, including the absence and presence of bone reactive processes and the relative plasticity of the bone at the moment of impact. The distribution by age, sex, and anatomical location of trauma was analyzed by means of logistic models, Fisher's exact tests, and 3D visualizations. RESULTS: A total of 130 perimortem traumas, including chop marks, slice marks, penetrating lesions, and blunt traumas were identified on 22 individuals. Chop marks were mostly at the level of the skull and vertebrae and were likely caused by bladed weapons. Slice marks were found on the cervical vertebrae and cranium and may be the result of throat slitting and scalping by means of smaller bladed implements. Traumas were more frequent in males, and their presence is not correlated with age. DISCUSSION: This study adds new data to the few available regarding violence among steppe nomadic cultures and provides new insights about the effects of political instability on the life of the people inhabiting Eastern Eurasia during the early centuries CE.


Assuntos
Povo Asiático/história , Violência/história , Ferimentos Penetrantes/história , Adolescente , Adulto , Antropologia Física , Osso e Ossos/lesões , Osso e Ossos/patologia , Sepultamento/história , Criança , Pré-Escolar , Decapitação/história , Feminino , História Antiga , Humanos , Lactente , Recém-Nascido , Masculino , Sibéria , Migrantes , Guerra/história , Adulto Jovem
16.
J Hum Evol ; 150: 102912, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33302003

RESUMO

Genetic and climate-driven estimates of past population dynamics are increasingly influential in broader models of hominin migration and adaptation, yet the contribution of stone artifact variability remains more contentious. Scientists are increasingly recognizing the potential of unretouched stone flakes ('flakes') in exploring existing models of hominin behavioral evolution. This is because flakes (1) were produced by all stone tool manufacturing groups in the past, (2) are abundant from the inception of the archaeological record up into the ethnographic present, and (3) preserve under most conditions. The statistical tools of 3D geometric morphometrics capture detailed approximations of flake form that are challenging to document with conventional artifact analyses. We analyze a collection of 717 3D scans of experimentally produced flakes from 5 production strategies that were practiced by hominins through large parts of the Pleistocene and that scientists have drawn on also to make demographic arguments about past human behavior (n = 45 reduction sequences, n = 3 knappers naive toward the study objectives). First, as a proof of concept, we demonstrate that we can estimate the strategies used to produce these flakes at a high success rate even when flakes from early stages of core reduction are included. We frame the significance of this finding against archaeological classifications from several key Middle Paleolithic assemblages in France (n = 4 sites, n = 28 layers, n = 16,467 flakes). Second, we show that 3D geometric morphometrics captures subtle differences in these strategies that influence flake formation on a flake-by-flake basis and that reflect decisions made by knappers about platform selection, preparation, and core-surface management. We explore the broader potential of our model with a cross-validation approach, and we describe a means of assessing flake form on a continuum wherein variability among assemblages separated by large expanses of space and time can be meaningfully explored.


Assuntos
Evolução Cultural , Hominidae , Tecnologia , Animais , Arqueologia
17.
Am J Phys Anthropol ; 173(3): 514-534, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32864759

RESUMO

OBJECTIVES: Understanding thoraco-pelvic integration in Homo sapiens and their closest living relatives (genus Pan) is of great importance within the context of human body shape evolution. However, studies assessing thoraco-pelvic covariation across Hominoidea species are scarce, although recent research would suggest shared covariation patterns in humans and chimpanzees but also species-specific features, with sexual dimorphism and allometry influencing thoraco-pelvic covariation in these taxa differently. MATERIAL AND METHODS: N = 30 adult H. sapiens and N = 10 adult Pan troglodytes torso 3D models were analyzed using 3D geometric morphometrics and linear measurements. Effects of sexual dimorphism and allometry on thoraco-pelvic covariation were assessed via regression analyses, and patterns of thoraco-pelvic covariation in humans and chimpanzees were computed via Two-Block Partial Least Squares analyses. RESULTS: Results confirm the existence of common aspects of thoraco-pelvic covariation in humans and chimpanzees, and also species-specific covariation in H. sapiens that is strongly influenced by sexual dimorphism and allometry. Species-specific covariation patterns in chimpanzees could not be confirmed because of the small sample size, but metrics point to a correspondence between the most caudal ribs and iliac crest morphology that would be irrespective of sex. CONCLUSIONS: This study suggests that humans and chimpanzees share common aspects of thoraco-pelvic covariation but might differ in others. In humans, torso integration is strongly influenced by sexual dimorphism and allometry, whilst in chimpanzees it may not be. This study also highlights the importance not only of torso widths but also of torso depths when describing patterns of thoraco-pelvic covariation in primates. Larger samples are necessary to support these interpretations.


Assuntos
Imageamento Tridimensional/métodos , Pan troglodytes/anatomia & histologia , Pelve/anatomia & histologia , Tórax/anatomia & histologia , Adulto , Anatomia Comparada , Animais , Antropologia Física , Feminino , Humanos , Masculino , Pelve/diagnóstico por imagem , Caracteres Sexuais , Tórax/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto Jovem
18.
J Hum Evol ; 147: 102854, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32805525

RESUMO

The skeletal torso is a complex structure of outstanding importance in understanding human body shape evolution, but reconstruction usually entails an element of subjectivity as researchers apply their own anatomical expertise to the process. Among different fossil reconstruction methods, 3D geometric morphometric techniques have been increasingly used in the last decades. Two-block partial least squares analysis has shown great potential for predicting missing elements by exploiting the covariation between two structures (blocks) in a reference sample: one block can be predicted from the other one based on the strength of covariation between blocks. The first aim of this study is to test whether this predictive approach can be used for predicting thorax morphologies from pelvis morphologies within adult Homo sapiens reference samples with known covariation between the thorax and the pelvis. The second aim is to apply this method to Kebara 2 Neandertal (Israel, ∼60 ka) to predict its thorax morphology using two different pelvis reconstructions as predictors. We measured 134 true landmarks, 720 curve semilandmarks, and 160 surface semilandmarks on 60 3D virtual torso models segmented from CT scans. We conducted three two-block partial least squares analyses between the thorax (block 1) and the pelvis (block 2) based on the H. sapiens reference samples after performing generalized Procrustes superimposition on each block separately. Comparisons of these predictions in full shape space by means of Procrustes distances show that the male-only predictive model yields the most reliable predictions within modern humans. In addition, Kebara 2 thorax predictions based on this model concur with the thorax morphology proposed for Neandertals. The method presented here does not aim to replace other techniques, but to rather complement them through quantitative prediction of a virtual 'scaffold' to articulate the thoracic fossil elements, thus extending the potential of missing data estimation beyond the methods proposed in previous works.


Assuntos
Fósseis/anatomia & histologia , Homem de Neandertal/anatomia & histologia , Pelve/anatomia & histologia , Tórax/anatomia & histologia , Animais , Antropologia Física , Processamento de Imagem Assistida por Computador , Israel , Masculino , Tomografia Computadorizada por Raios X
19.
J Craniomaxillofac Surg ; 47(6): 951-958, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30935849

RESUMO

INTRODUCTION: There has been a shift toward surgical treatment of ZMC (zygomaticomaxillary complex) fractures with open reduction and subsequent fixation in the past decades. Anatomically preformed osteosynthesis plates, already used in the field of craniomaxillofacial surgery for the treatment of fractures of the mandible and the orbit, might be a suitable option for ZMC fractures as well. MATERIAL AND METHODS: A statistical shape model was created from 179 cranial CT scans. Based on this surface model, an anatomically preformed plate for the reduction and fixation of ZMC fractures was developed in 3 sizes (S, M, L). Virtual analysis of the accuracy of the plate was performed on a dataset consisting of 120 CT scans. RESULTS: Within a determined tolerance range of 0-1.5 mm, analysis revealed a high accuracy of the plate in 70-87 % of the CT scans. The S-sized plate has the highest overall accuracy, whereas the L-sized plate has highest accuracy at the "base" region which is essential for the placement of the plate. DISCUSSION: The newly developed plate can be placed via an intraoral approach and analysis of the plate has confirmed its accuracy to be sufficient to ensure an adequate fracture reduction and fixation. It thus might allow for a less extensive approach and less approaches/incisions necessary overall to reduce and fixate ZMC fractures.


Assuntos
Fraturas Ósseas , Procedimentos de Cirurgia Plástica , Placas Ósseas , Fixação de Fratura , Fixação Interna de Fraturas , Humanos
20.
J Craniomaxillofac Surg ; 47(7): 1054-1059, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30982558

RESUMO

PURPOSE: Mirroring and manual adaptation as the main virtual reconstruction method of midfacial defects is time demanding and ignores asymmetrical skull shapes. By using a statistical shape model (SSM), the reconstruction can be automatized and specified. The current study aims to show the ability of the SSM in the virtual reconstruction of artificial bilateral defects. METHODS: Based on 131 pathologically unaffected CT scans of the adult midface region, an SSM was created. DICOM data were generated, segmented and registered on one mesh, which serves as template for the SSM. The SSM consists of the registered surface meshes and includes the shape variability of the cranial vault. Fractured or missing parts were calculated by the known shape variability of healthy midface data. Using 25 CT scans not included in the SSM, the precision of the reconstruction of virtually placed bilateral defects of the orbital floor (Group 1) and bilateral naso-orbital-ethmoid (NOE) fractures (Group 2). Distances to the corresponding parts of the intact skull were calculated to show the accuracy of the virtual reconstruction method. RESULTS: All defects could be reconstructed by using the SSM and GM technique. The analysis shows a high accuracy of the SSM-driven reconstruction, with a mean error of 0.75 ± 0.18 mm in group 1 and with a mean error of 0.81 ± 0.23 mm in group 2. CONCLUSION: The precision of the SSM-driven reconstruction is high and its application is easy for the clinician because of the automatization of the virtual reconstruction process in the field of computer-assisted surgery (CAS). Respecting of the natural asymmetry of the skull and the methods of GM are reasons for the high precision and the automatization of the new shown reconstruction workflow.


Assuntos
Modelos Estatísticos , Fraturas Orbitárias , Cirurgia Assistida por Computador , Adulto , Humanos , Imageamento Tridimensional , Crânio , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA