Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
BMC Biol ; 22(1): 67, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38504308

RESUMO

BACKGROUND: Insects have evolved complex visual systems and display an astonishing range of adaptations for diverse ecological niches. Species of Drosophila melanogaster subgroup exhibit extensive intra- and interspecific differences in compound eye size. These differences provide an excellent opportunity to better understand variation in insect eye structure and the impact on vision. Here we further explored the difference in eye size between D. mauritiana and its sibling species D. simulans. RESULTS: We confirmed that D. mauritiana have rapidly evolved larger eyes as a result of more and wider ommatidia than D. simulans since they recently diverged approximately 240,000 years ago. The functional impact of eye size, and specifically ommatidia size, is often only estimated based on the rigid surface morphology of the compound eye. Therefore, we used 3D synchrotron radiation tomography to measure optical parameters in 3D, predict optical capacity, and compare the modelled vision to in vivo optomotor responses. Our optical models predicted higher contrast sensitivity for D. mauritiana, which we verified by presenting sinusoidal gratings to tethered flies in a flight arena. Similarly, we confirmed the higher spatial acuity predicted for Drosophila simulans with smaller ommatidia and found evidence for higher temporal resolution. CONCLUSIONS: Our study demonstrates that even subtle differences in ommatidia size between closely related Drosophila species can impact the vision of these insects. Therefore, further comparative studies of intra- and interspecific variation in eye morphology and the consequences for vision among other Drosophila species, other dipterans and other insects are needed to better understand compound eye structure-function and how the diversification of eye size, shape, and function has helped insects to adapt to the vast range of ecological niches.


Assuntos
Drosophila melanogaster , Drosophila , Animais , Drosophila/fisiologia , Drosophila melanogaster/genética , Olho/anatomia & histologia , Especificidade da Espécie
2.
Adv Sci (Weinh) ; : e2308811, 2024 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-38520713

RESUMO

Articular cartilage and meniscus transfer and distribute mechanical loads in the knee joint. Degeneration of these connective tissues occurs during the progression of knee osteoarthritis, which affects their composition, microstructure, and mechanical properties. A deeper understanding of disease progression can be obtained by studying them simultaneously. Time-resolved synchrotron-based X-ray phase-contrast tomography (SR-PhC-µCT) allows to capture the tissue dynamics. This proof-of-concept study presents a rheometer setup for simultaneous in situ unconfined compression and SR-PhC-µCT of connective knee tissues. The microstructural response of bovine cartilage (n = 16) and meniscus (n = 4) samples under axial continuously increased strain, or two steps of 15% strain (stress-relaxation) is studied. The chondrocyte distribution in cartilage and the collagen fiber orientation in the meniscus are assessed. Variations in chondrocyte density reveal an increase in the top 40% of the sample during loading, compared to the lower half. Meniscus collagen fibers reorient perpendicular to the loading direction during compression and partially redisperse during relaxation. Radiation damage, image repeatability, and image quality assessments show little to no effects on the results. In conclusion, this approach is highly promising for future studies of human knee tissues to understand their microstructure, mechanical response, and progression in degenerative diseases.

3.
Proc Natl Acad Sci U S A ; 121(12): e2316723121, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38478686

RESUMO

Many environmental and industrial processes depend on how fluids displace each other in porous materials. However, the flow dynamics that govern this process are still poorly understood, hampered by the lack of methods to measure flows in optically opaque, microscopic geometries. We introduce a 4D microvelocimetry method based on high-resolution X-ray computed tomography with fast imaging rates (up to 4 Hz). We use this to measure flow fields during unsteady-state drainage, injecting a viscous fluid into rock and filter samples. This provides experimental insight into the nonequilibrium energy dynamics of this process. We show that fluid displacements convert surface energy into kinetic energy. The latter corresponds to velocity perturbations in the pore-scale flow field behind the invading fluid front, reaching local velocities more than 40 times faster than the constant pump rate. The characteristic length scale of these perturbations exceeds the characteristic pore size by more than an order of magnitude. These flow field observations suggest that nonlocal dynamic effects may be long-ranged even at low capillary numbers, impacting the local viscous-capillary force balance and the representative elementary volume. Furthermore, the velocity perturbations can enhance unsaturated dispersive mixing and colloid transport and yet, are not accounted for in current models. Overall, this work shows that 4D X-ray velocimetry opens the way to solve long-standing fundamental questions regarding flow and transport in porous materials, underlying models of, e.g., groundwater pollution remediation and subsurface storage of CO2 and hydrogen.

4.
Heliyon ; 10(4): e26025, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38384517

RESUMO

The mechanism governing pharmaceutical tablet disintegration is far from fully understood. Despite the importance of controlling a formulation's disintegration process to maximize the active pharmaceutical ingredient's bioavailability and ensure predictable and consistent release profiles, the current understanding of the process is based on indirect or superficial measurements. Formulation science could, therefore, additionally deepen the understanding of the fundamental physical principles governing disintegration based on direct observations of the process. We aim to help bridge the gap by generating a series of time-resolved X-ray micro-computed tomography (µCT) images capturing volumetric images of a broad range of mini-tablet formulations undergoing disintegration. Automated image segmentation was a prerequisite to overcoming the challenges of analyzing multiple time series of heterogeneous tomographic images at high magnification. We devised and trained a convolutional neural network (CNN) based on the U-Net architecture for autonomous, rapid, and consistent image segmentation. We created our own µCT data reconstruction pipeline and parameterized it to deliver image quality optimal for our CNN-based segmentation. Our approach enabled us to visualize the internal microstructures of the tablets during disintegration and to extract parameters of disintegration kinetics from the time-resolved data. We determine by factor analysis the influence of the different formulation components on the disintegration process in terms of both qualitative and quantitative experimental responses. We relate our findings to known formulation component properties and established experimental results. Our direct imaging approach, enabled by deep learning-based image processing, delivers new insights into the disintegration mechanism of pharmaceutical tablets.

5.
Commun Biol ; 7(1): 157, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38326549

RESUMO

The characterization of the vibrations of the middle ear ossicles during sound transmission is a focal point in clinical research. However, the small size of the structures, their micrometer-scale movement, and the deep-seated position of the middle ear within the temporal bone make these types of measurements extremely challenging. In this work, dynamic synchrotron-based X-ray phase-contrast microtomography is used on acoustically stimulated intact human ears, allowing for the three-dimensional visualization of entire human eardrums and ossicular chains in motion. A post-gating algorithm is used to temporally resolve the fast micromotions at 128 Hz, coupled with a high-throughput pipeline to process the large tomographic datasets. Seven ex-vivo fresh-frozen human temporal bones in healthy conditions are studied, and the rigid body motions of the ossicles are quantitatively delineated. Clinically relevant regions of the ossicular chain are tracked in 3D, and the amplitudes of their displacement are computed for two acoustic stimuli.


Assuntos
Imageamento Tridimensional , Síncrotrons , Humanos , Raios X , Orelha Média/diagnóstico por imagem , Ossículos da Orelha/diagnóstico por imagem
6.
J Synchrotron Radiat ; 31(Pt 1): 150-161, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38117694

RESUMO

Third- and fourth-generation synchrotron light sources with high fluxes and beam energies enable the use of innovative X-ray translucent experimental apparatus. These experimental devices access geologically relevant conditions whilst enabling in situ characterization using the spatial and temporal resolutions accessible at imaging beamlines. Here, Heitt Mjölnir is introduced, a heated miniature triaxial rig based on the design of Mjölnir, but covering a wider temperature range and larger sample volume at similar pressure capacities. This device is designed to investigate coupled thermal, chemical, hydraulic and mechanical processes from grain to centimetre scales using cylindrical samples of 10 mm × 20 mm (diameter × length). Heitt Mjölnir can simultaneously reach confining (hydraulic) pressures of 30 MPa and 500 MPa of axial stress with independently controlled sample pore fluid pressure < 30 MPa. This internally heated apparatus operates to temperatures up to 573 K with a minimal vertical thermal gradient in the sample of <0.3 K mm-1. This new apparatus has been deployed in operando studies at the TOMCAT (Swiss Light Source), I12 JEEP (Diamond Light Source) and PSICHÉ (Synchrotron SOLEIL) beamlines for 4D X-ray microtomography with scan intervals of a few minutes. Heitt Mjölnir is portable and modular, allowing a wide range of 4D characterizations of low-grade metamorphism and deformational processes. It enables spatially and temporally resolved fluid-rock interaction studies at conditions of crustal reservoirs and is suitable for characterization of material properties in geothermal, carbonation or subsurface gas storage applications. Technical drawings and an operation guide are included in this publication.

7.
Cells ; 12(19)2023 09 28.
Artigo em Inglês | MEDLINE | ID: mdl-37830589

RESUMO

(1) Background: Stereological estimations significantly contributed to our understanding of lung anatomy and physiology. Taking stereology fully 3-dimensional facilitates the estimation of novel parameters. (2) Methods: We developed a protocol for the analysis of all airspaces of an entire lung. It includes (i) high-resolution synchrotron radiation-based X-ray tomographic microscopy, (ii) image segmentation using the free machine-learning tool Ilastik and ImageJ, and (iii) calculation of the airspace diameter distribution using a diameter map function. To evaluate the new pipeline, lungs from adult mice with cystic fibrosis (CF)-like lung disease (ßENaC-transgenic mice) or mice with elastase-induced emphysema were compared to healthy controls. (3) Results: We were able to show the distribution of airspace diameters throughout the entire lung, as well as separately for the conducting airways and the gas exchange area. In the pathobiological context, we observed an irregular widening of parenchymal airspaces in mice with CF-like lung disease and elastase-induced emphysema. Comparable results were obtained when analyzing lungs imaged with µCT, sugges-ting that our pipeline is applicable to different kinds of imaging modalities. (4) Conclusions: We conclude that the airspace diameter map is well suited for a detailed analysis of unevenly distri-buted structural alterations in chronic muco-obstructive lung diseases such as cystic fibrosis and COPD.


Assuntos
Fibrose Cística , Enfisema , Doença Pulmonar Obstrutiva Crônica , Enfisema Pulmonar , Camundongos , Animais , Fibrose Cística/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Enfisema Pulmonar/diagnóstico por imagem , Elastase Pancreática
8.
Zool Stud ; 61: e51, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36568820

RESUMO

Bursinia genei (Dufour, 1849) is the most widespread species of the planthopper subfamily Orgeriinae (Hemiptera: Fulgoromorpha: Dictyopharidae) in Europe, found from the Iberian Peninsula to the Western Balkans. However, its diagnostically important genitalia and biology have been insufficiently described. We employ state-of-the-art synchrotron X-ray microtomography and photomicrography to re-describe B. genei, and to study the morphology of both its sexes in unprecedented detail. By examining specimens from across the distribution of B. genei, we find that they probably belong to a single, broadly distributed morphospecies. Our morphological examination allowed us to make inferences on its jumping mechanism and capacity for vibrational communication. We also record B. genei for the first time from Greece, further extending the range of this elusive species. Detailed information on the habitat of B. genei is also provided.

9.
Appl Opt ; 61(13): 3850-3854, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-36256429

RESUMO

Precisely aligned optical components are crucial prerequisites for X-ray tomography at high resolution. We propose a device with a fractal pattern for precise automatic focusing. The device is etched in a Si substrate by deep reactive ion etching and then filled by a self-terminating bottom-up Au electroplating process. The fractal nature of the device produces an X-ray transmission image with globally homogeneous macroscopic visibility and high local contrast for pixel sizes in the range of 0.165 µm to 11 µm, while the high absorption contrast provided between Au and Si enables its use for X-ray energies ranging from 12 keV to 40 keV.

10.
J Colloid Interface Sci ; 626: 416-425, 2022 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-35803141

RESUMO

HYPOTHESIS: Wicking flow in the wale direction of knit fabrics is slowed by capillary pressure minima during the transition at yarn contacts. The characteristic pore structure of yarns leads to an unfavorable free energy evolution and is the cause of these minima. EXPERIMENTS: Time-resolved synchrotron tomographic microscopy is employed to study the evolution of water configuration during wicking flow in interlacing yarns. Dynamic pore network modeling is used based on the obtained image data and distributions of delay times for pore intrusion. Good agreement is observed by comparison to the experimental data. FINDINGS: Yarn-to-yarn transition is found to coincide with slow water advance in a thin interface zone at the yarn contact. The pore spaces of the two yarns merge within this interface zone and provide a transition path. A deep capillary pressure minimum occurs while water passes through the center of the interface zone, effectively delaying the wicking flow. A pore network model considering pore intrusion delay times is expanded to include inter-yarn wicking and reproduce the observed wicking dynamics.


Assuntos
Têxteis , Água , Ação Capilar
11.
J Colloid Interface Sci ; 625: 1-11, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35714401

RESUMO

The spontaneous imbibition of a liquid within porous media, known as wicking, can display uncommon features in textiles and yarns. Yarns exhibited step-wise wicking dynamics not captured by current models. HYPOTHESIS: Wicking dynamics in yarns not only depend on inter-fiber pore filling, but are mainly determined by the pore-to-pore transition processes and the structure of the pore network. EXPERIMENTS: Fast X-ray tomographic microscopy is employed to reveal the pore scale processes and neutron radiography for the macroscopic water uptake in yarns. A semi-empirical pore network model is presented that employs the measured pore network topology and pore scale dynamics to reproduce the experimentally observed wicking dynamics in yarns. FINDINGS: The yarn pore system is a sparse network of long and narrow pores that promotes step-wise uptake dynamics. Wicking in yarns displays fast pore filling events in the order of seconds and long waiting times between filling events up to several minutes while navigating the pore network. As main result, we find that a few filling events directly determine the macroscopic behavior of wicking in the sparse pore network of yarns. It is necessary to consider pore-to-pore transition waiting times and the pore network structure to explain the characteristics of wicking dynamics in yarns.


Assuntos
Têxteis , Ação Capilar
12.
J Med Imaging (Bellingham) ; 9(3): 031507, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35372637

RESUMO

Purpose: Synchrotron radiation-based tomography yields microanatomical features in human and animal tissues without physical slicing. Recent advances in instrumentation have made laboratory-based phase tomography feasible. We compared the performance of three cutting-edge laboratory systems benchmarked by synchrotron radiation-based tomography for three specimens. As an additional criterion, the user-friendliness of the three microtomography systems was considered. Approach: The three tomography systems-SkyScan 2214 (Bruker-microCT, Kontich, Belgium), Exciscope prototype (Stockholm, Sweden), and Xradia 620 Versa (Zeiss, Oberkochen, Germany)-were given 36 h to measure three medically relevant specimens, namely, zebrafish larva, archaeological human tooth, and porcine nerve. The obtained datasets were registered to the benchmark synchrotron radiation-based tomography from the same specimens and selected ones to the SkyScan 1275 and phoenix nanotom m® laboratory systems to characterize development over the last decade. Results: Next-generation laboratory-based microtomography almost reached the quality achieved by synchrotron-radiation facilities with respect to spatial and density resolution, as indicated by the visualization of the medically relevant microanatomical features. The SkyScan 2214 system and the Exciscope prototype demonstrated the complementarity of phase information by imaging the eyes of the zebrafish larva. The 3 - µ m thin annual layers in the tooth cementum were identified using Xradia 620 Versa. Conclusions: SkyScan 2214 was the simplest system and was well-suited to visualizing the wealth of anatomical features in the zebrafish larva. Data from the Exciscope prototype with the high photon flux from the liquid metal source showed the spiral nature of the myelin sheaths in the porcine nerve. Xradia 620 Versa, with detector optics as typically installed for synchrotron tomography beamlines, enabled the three-dimensional visualization of the zebrafish larva with comparable quality to the synchrotron data and the annual layers in the tooth cementum.

13.
J Exp Biol ; 225(1)2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34904652

RESUMO

Modern bony fishes possess a high morphological diversity in their auditory structures and auditory capabilities. Yet, how auditory structures such as the otoliths in the inner ears and the swim bladder work together remains elusive. Gathering experimental evidence on the in situ motion of fish auditory structures while avoiding artifacts caused by surgical exposure of the structures has been challenging for decades. Synchrotron radiation-based tomography with high spatio-temporal resolution allows the study of morphofunctional issues non-invasively in an unprecedented way. We therefore aimed to develop an approach that characterizes the moving structures in 4D (=three spatial dimensions+time). We designed a miniature standing wave tube-like setup to meet both the requirements of tomography and those of tank acoustics. With this new setup, we successfully visualized the motion of isolated otoliths and the auditory structures in zebrafish (Danio rerio) and glass catfish (Kryptopterus vitreolus).


Assuntos
Audição , Peixe-Zebra , Animais , Membrana dos Otólitos , Som , Tomografia
14.
Front Cardiovasc Med ; 9: 1023483, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36620622

RESUMO

Introduction: Cardiac architecture has been extensively investigated ex vivo using a broad spectrum of imaging techniques. Nevertheless, the heart is a dynamic system and the structural mechanisms governing the cardiac cycle can only be unveiled when investigating it as such. Methods: This work presents the customization of an isolated, perfused heart system compatible with synchrotron-based X-ray phase contrast imaging (X-PCI). Results: Thanks to the capabilities of the developed setup, it was possible to visualize a beating isolated, perfused rat heart for the very first time in 4D at an unprecedented 2.75 µm pixel size (10.6 µm spatial resolution), and 1 ms temporal resolution. Discussion: The customized setup allows high-spatial resolution studies of heart architecture along the cardiac cycle and has thus the potential to serve as a tool for the characterization of the structural dynamics of the heart, including the effects of drugs and other substances able to modify the cardiac cycle.

15.
Bioinspir Biomim ; 16(6)2021 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-34608869

RESUMO

Bamboo is becoming increasingly popular as an engineering material and source of bio-inspiration for instance in architecture and for the manufacture of a variety of woven products. Besides the properties of bamboo products for construction purposes, the bending deformability of thin bamboo slivers is of interest, as it appears that extraordinary large deflection can be achieved. To unravel the underlying mechanisms that may contribute to the high deformability at the tissue and cell level, bending deflection tests and additionalin situexperiments were performed to record the deflection of bamboo slivers in dependence of the tissue composition and the deformations of individual cells. For the latter, a simple bending deflection setup was used employing micro-CT measurements to analyze the deformation of individual parenchyma cells (PCs), fiber bundles and vessel elements at different stages of bending deformation of the bamboo slivers. The results showed that the degree of displacement and the characteristic fracture behavior strongly depend on the volume fractions of PCs and fibres determined by the position in the bamboo culm. For slivers with a sufficiently high fibre volume content, the very high bending deformability could be facilitated by the deformation of PCs, which are squeezed between the fibre bundles during increasing bending deflection.


Assuntos
Engenharia , Sasa
16.
Phys Rev E ; 103(5-1): 053101, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34134200

RESUMO

What are the mechanisms at play in the spontaneous imbibition dynamics in polyethylene terephthalate filament yarns at pore scale? Processes at pore scale such as waiting times between the filling of two neighboring pores, as observed in special irregular porous media, like yarns, may overrule the predicted behavior by well-known laws such as Washburn's law. While the imbibition physics are well known, classic models like Washburn's law cannot explain the dynamics observed for yarns. The stepwise dynamics is discussed in terms of the interplay of thermodynamic free energy and viscous dissipation. Time-resolved synchrotron x-ray microtomography documents water filling at pore scale. Spontaneous imbibition in yarns is characterized by a series of fast pore-filling events separated by long periods of low flux. Four-dimensional imaging allows the extraction of interface areas at the boundaries between water, air, and polymer and the calculation of free-energy evolution. It is found that the waiting periods correspond to quasistable water configurations of almost vanishing free-energy gradient. The distributions of pore filling event sizes and waiting times spread over several orders of magnitude, resulting in the pronounced stepwise uptake dynamics.

17.
Materials (Basel) ; 14(9)2021 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-33946697

RESUMO

An open-porous protein sponge with mixed wettability is presented made entirely from whey proteins and with promising applications in biomedicine, pharmaceutical, and food industry. The fabrication relies on an additive-free, clean and scalable process consisting of foaming followed by controlled microwave-convection drying. Volumetric heating throughout the matrix induced by microwaves causes fast expansion and elongation of the foam bubbles, retards crust formation and promotes early protein denaturation. These effects counteract collapse and shrinkage typically encountered in convection drying of foams. The interplay of high protein content, tailored gas incorporation and controlled drying result in a dried structure with dual-scale porosity composed of open macroscopic elongated foam bubbles and microscopic pores in the surrounding solid lamellae induced by water evaporation. Due to the insolubility and mixed wettability of the denatured protein network, polar and non-polar liquids are rapidly absorbed into the interconnected capillary system of the sponge without disintegrating. While non-watery liquids penetrate the pores by capillary suction, water diffuses also into the stiff protein matrix, inducing swelling and softening. Consequently, the water-filled soft sponge can be emptied by compression and re-absorbs any wetting liquid into the free capillary space.

18.
Histochem Cell Biol ; 155(2): 215-226, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32189111

RESUMO

In this article, we present an X-ray tomographic imaging method that is well suited for pulmonary disease studies in animal models to resolve the full pathway from gas intake to gas exchange. Current state-of-the-art synchrotron-based tomographic phase-contrast imaging methods allow for three-dimensional microscopic imaging data to be acquired non-destructively in scan times of the order of seconds with good soft tissue contrast. However, when studying multi-scale hierarchically structured objects, such as the mammalian lung, the overall sample size typically exceeds the field of view illuminated by the X-rays in a single scan and the necessity for achieving a high spatial resolution conflicts with the need to image the whole sample. Several image stitching and calibration techniques to achieve extended high-resolution fields of view have been reported, but those approaches tend to fail when imaging non-stable samples, thus precluding tomographic measurements of large biological samples, which are prone to degradation and motion during extended scan times. In this work, we demonstrate a full-volume three-dimensional reconstruction of an intact rat lung under immediate post-mortem conditions and at an isotropic voxel size of (2.75 µm)3. We present the methodology for collecting multiple local tomographies with 360° extended field of view scans followed by locally non-rigid volumetric stitching. Applied to the lung, it allows to resolve the entire pulmonary structure from the trachea down to the parenchyma in a single dataset. The complete dataset is available online ( https://doi.org/10.16907/7eb141d3-11f1-47a6-9d0e-76f8832ed1b2 ).


Assuntos
Imageamento Tridimensional , Pneumopatias/patologia , Tomografia Computadorizada por Raios X , Animais , Pneumopatias/metabolismo , Ratos , Ratos Wistar
19.
J Comp Neurol ; 529(3): 616-634, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32592497

RESUMO

A great diversity of adaptations is found among animals with compound eyes and even closely related taxa can show variation in their light-adaptation strategies. A prime example of a visual system evolved to function in specific light environments is the fiddler crab, used widely as a model to research aspects of crustacean vision and neural pathways. However, questions remain regarding how their eyes respond to the changes in brightness spanning many orders of magnitude, associated with their habitat and ecology. The fiddler crab Afruca tangeri forages at low tide on tropical and semi-tropical mudflats, under bright sunlight and on moonless nights, suggesting that their eyes undergo effective light adaptation. Using synchrotron X-ray tomography, light and transmission electron microscopy and in vivo ophthalmoscopy, we describe the ultrastructural changes in the eye between day and night. Dark adaptation at dusk triggered extensive widening of the rhabdoms and crystalline cone tips. This doubled the ommatidial acceptance angles and increased microvillar surface area for light capture in the rhabdom, theoretically boosting optical sensitivity 7.4 times. During daytime, only partial dark-adaptation was achieved and rhabdoms remained narrow, indicating strong circadian control on the process. Bright light did not evoke changes in screening pigment distributions, suggesting a structural inability to adapt rapidly to the light level fluctuations frequently experienced when entering their burrow to escape predators. This should enable fiddler crabs to shelter for several minutes without undergoing significant dark-adaptation, their vision remaining effectively adapted for predator detection when surfacing again in bright light.


Assuntos
Adaptação Ocular/fisiologia , Olho/química , Olho/citologia , Fenômenos Fisiológicos Oculares , Animais , Braquiúros , Olho/metabolismo , Feminino , Masculino , Microscopia Eletrônica de Transmissão/métodos
20.
Small ; 16(31): e2000746, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32567135

RESUMO

Metal-based nanoparticles are clinically used for diagnostic and therapeutic applications. After parenteral administration, they will distribute throughout different organs. Quantification of their distribution within tissues in the 3D space, however, remains a challenge owing to the small particle diameter. In this study, synchrotron radiation-based hard X-ray tomography (SRµCT) in absorption and phase contrast modes is evaluated for the localization of superparamagnetic iron oxide nanoparticles (SPIONs) in soft tissues based on their electron density and X-ray attenuation. Biodistribution of SPIONs is studied using zebrafish embryos as a vertebrate screening model. This label-free approach gives rise to an isotropic, 3D, direct space visualization of the entire 2.5 mm-long animal with a spatial resolution of around 2 µm. High resolution image stacks are available on a dedicated internet page (http://zebrafish.pharma-te.ch). X-ray tomography is combined with physico-chemical characterization and cellular uptake studies to confirm the safety and effectiveness of protective SPION coatings. It is demonstrated that SRµCT provides unprecedented insights into the zebrafish embryo anatomy and tissue distribution of label-free metal oxide nanoparticles.


Assuntos
Nanopartículas de Magnetita , Nanopartículas Metálicas , Animais , Óxidos , Distribuição Tecidual , Tomografia Computadorizada por Raios X , Peixe-Zebra
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA