Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Cytotherapy ; 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38795114

RESUMO

BACKGROUND AIMS: ABO incompatibility does not hinder bone marrow transplantation (BMT), but it has been associated with worse outcomes and additional adverse events. This study aimed to verify the impact of incompatible red blood cells (iRBCs) in allogeneic BMT and to determine a safe number of iRBCs to be infused. METHODS: We compared ABO-incompatible (iABO) allogeneic BMT (n = 42) with ABO-compatible allogeneic BMT (n = 44) and evaluated the impact of the number of infused iRBCs on outcomes and adverse events. RESULTS: The iABO patients demonstrated delayed time to transfusion independence at 30 days and 60 days, increased requirement for red blood cell (RBC) transfusion and greater hemolysis signals and incidence of pure red cell aplasia. Neutrophil/platelet engraftment, length of hospitalization post-transplant, platelet units required, graft-versus-host disease occurrence and overall survival were similar in both groups. Patients in the iABO group received 1.03 × 1010 iRBCs/kg (range, 0.36-3.88). Infusion of iRBCs >1.0 × 1010 /kg was related to graft failure or death before neutrophil engraftment or platelet engraftment or both as well as increased plasma requirement and increased creatinine. Our results also suggest that antibody titers impact the transplantation scenario. CONCLUSIONS: The iABO transplantation showed some unfavorable outcomes. It is important to monitor the value of iRBCs to be infused, considering the recipient antibody titers. We propose using the number of iRBCs (iRBCs/kg) as a dose parameter with regard to infused iRBCs. Further studies are necessary to clarify the maximum safe number of iRBCs in iABO transplants.

2.
Transfusion ; 62(10): 1967-1972, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36052689

RESUMO

BACKGROUND: Autologous stem cell transplantation is the standard procedure for multiple myeloma and the grafts are usually cryopreserved. Previous studies reported advantages in the use of fresh peripheral blood stem cells (PBSC) autotransplantation compared to cryopreservation of the grafts. This study compared the transplant-related outcomes of two graft preservation methods: fresh storage (4°C/72 h) and cryopreservation (-80°C). STUDY DESIGN AND METHODS: We performed an analysis of 45 patients with multiple myeloma under autotransplantation (17 fresh and 28 cryopreserved) from 2017 to 2021. Fresh PBSC were maintained in the refrigerator for three days in a concentration up to 300 × 103 TNC/µL. Cryopreserved PBSC were concentrated by plasma reduction after centrifugation (950 g/10 min/4°C) and an equal volume of cryoprotection solution was added for a final concentration of 300 × 103 TNC/µL, 5% DMSO, 6% hydroxyethyl starch, and 3% human albumin. RESULTS: Neutrophil engraftment was significantly faster with fresh PBSCs (10 vs. 11.5 days, p = 0.045). Adverse effects were more common in cryopreserved PBSC transplantation (75% vs. 35.3% patients; p = 0.013). Post transplantation hospital stay was 20 and 22 days for fresh and cryopreserved PBSCs respectively (p = 0.091). There was no difference in platelet engraftment time (10.5 days for both; p = 0.133), number of antibiotics used after transplantation (3 for fresh and 2.5 for cryopreserved; p = 0.828), days of antibiotic use after transplantation (12.2 days for fresh and 13.3 days for cryopreserved, p = 0.579), and overall survival (p = 0.736). CONCLUSION: The infusion of fresh PBSC refrigerated for up to three days is effective and safe for autologous transplantation in patients with multiple myeloma, which is a useful alternative to cryopreserved PBSC.


Assuntos
Transplante de Células-Tronco Hematopoéticas , Mieloma Múltiplo , Células-Tronco de Sangue Periférico , Antibacterianos , Criopreservação/métodos , Dimetil Sulfóxido , Humanos , Mieloma Múltiplo/terapia , Albumina Sérica Humana , Amido , Transplante Autólogo/métodos
3.
Transfus Apher Sci ; 61(1): 103298, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34696981

RESUMO

INTRODUCTION: Peripheral blood stem cells are widely used in autologous or allogeneic transplantation. The quality of the product directly impacts clinical outcomes, and the cell quality and/or functionality may be influenced by the storage conditions as time, temperature, total nucleated cells (TNC) concentration and cryopreservation requirement. OBJECTIVE: To verify the effects of time, cell concentration, and cryopreservation/thawing in the viability and functionality of stem cells for transplantation. METHODS: We evaluated TNC, CD45+ viable cells, CD34+ viable cells, and cell viability and functionality of 11 samples. Measurements were performed immediately and 24 h, 48 h, 72 h, and 96 h after sample collection at high and low TNC concentrations. The same parameters were also evaluated after cryopreservation and thawing of the samples. RESULT: Duration of storage and TNC concentration exhibited a negative effect on cell quality (CD45+ viable cells, CD34+ viable cells and functionality). Moreover, the association of these parameters increased the negative effect on graft quality. Cryopreservation and thawing also negatively affected the collected sample regarding viable CD34+ cells (recovery 66.2 %), viable CD45+ cells (recovery 56.8 %), and 7-AAD viability. No significant losses in viable CD45+/CD34+ cells and functionality were observed in the first 24 h in both TNC conditions. CONCLUSION: These results emphasize the importance to consider carefully the storage conditions until transplantation, measuring TNC/µL until 24 h after collection (diluting the product when TNC > 300 × 103/µL) and infusing fresh graft as soon as possible.


Assuntos
Criopreservação/métodos , Transplante de Células-Tronco de Sangue Periférico/métodos , Células-Tronco de Sangue Periférico/metabolismo , Adulto , Idoso , Humanos , Pessoa de Meia-Idade
5.
Braz J Infect Dis ; 16(4): 345-50, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22846122

RESUMO

Hematopoietic progenitor cells from peripheral blood (HPCPB) are commonly used for autologous and allogenic transplants in patients with most various onco-hematological diseases, and despite the utilization of sterile techniques during collection and processing of these products, bacterial contamination can occur. This study aimed to investigate the microbial contamination of HPCPB products. Microbial cultures of 837 HPCPB products between the year 2000 and 2009 were retrospectively analyzed to determine the incidence of culture positivity and identify the main organisms that cause contamination. The microbiological studies were performed with an automated system (BacT/Alert(®) bioMérieux Corporate). Thirty-six (4.3%) of 837 microbial cultures were contaminated. Coagulase-negative Staphylococcus was the most frequent bacteria isolated from HPCPB products (20 [56%] of the 36 positive microbial cultures). Considering the 36 contaminated samples, 22 HPCPB products were infused and 14 discarded. Pre- and post-infusion antibiotic therapy of the patients transfused with contaminated products was established based on the isolated microorganism and its antibiogram. Microbial contamination rate of HPCPB products was low. Clinically significant outcomes after infusion of contaminated HPCPB products were not observed.


Assuntos
Transplante de Células-Tronco Hematopoéticas , Células-Tronco Hematopoéticas/microbiologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Transplante Autólogo
6.
Braz. j. infect. dis ; 16(4): 345-350, July-Aug. 2012. ilus, tab
Artigo em Inglês | LILACS | ID: lil-645423

RESUMO

Hematopoietic progenitor cells from peripheral blood (HPCPB) are commonly used for autologous and allogenic transplants in patients with most various onco-hematological diseases, and despite the utilization of sterile techniques during collection and processing of these products, bacterial contamination can occur. This study aimed to investigate the microbial contamination of HPCPB products. Microbial cultures of 837 HPCPB products between the year 2000 and 2009 were retrospectively analyzed to determine the incidence of culture positivity and identify the main organisms that cause contamination. The microbiological studies were performed with an automated system (BacT/Alert® bioMérieux Corporate). Thirty-six (4.3%) of 837 microbial cultures were contaminated. Coagulase-negative Staphylococcus was the most frequent bacteria isolated from HPCPB products (20 [56%] of the 36 positive microbial cultures). Considering the 36 contaminated samples, 22 HPCPB products were infused and 14 discarded. Pre-and post-infusion antibiotic therapy of the patients transfused with contaminated products was established based on the isolated microorganism and its antibiogram. Microbial contamination rate of HPCPB products was low. Clinically significant outcomes after infusion of contaminated HPCPB products were not observed.


Assuntos
Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Transplante de Células-Tronco Hematopoéticas , Células-Tronco Hematopoéticas/microbiologia , Estudos Retrospectivos , Transplante Autólogo
7.
Rev. bras. hematol. hemoter ; 32(1): 23-28, fev. 2010. tab
Artigo em Português | LILACS | ID: lil-551506

RESUMO

A taxa de contaminação microbiana dos produtos de células progenitoras hematopoéticas do sangue periférico é baixa. Neste estudo pesquisou-se a prevalência de hemoculturas positivas em células progenitoras hematopoéticas do sangue periférico (CPHSP) no Serviço de Hemoterapia do Hospital de Clínicas de Porto Alegre. Do total de 618 coletas realizadas no período de 2000 a 2007, 26 (4,2 por cento) apresentaram contaminação por bactérias. O Staphylococcus coagulase-negativo foi predominantemente isolado nas hemoculturas. A antibioticoterapia pré e pós-infusão foi estabelecida de acordo com o microorganismo e seu antibiograma, sendo que, em cinco das doze infusões contaminadas realizadas, não foram administrados antimicrobianos profilaticamente. Episódios febris foram observados em sete pacientes (58 por cento), enquanto cinco (42 por cento) não apresentaram febre. Das doze infusões contaminadas realizadas, seis (50 por cento) apresentaram hemocultura pós-descongelamento positivas, enquanto as restantes (50 por cento) foram negativas. Isto se deve às propriedades bactericidas do DMSO, de células fagocitose-ativas e de temperaturas muito baixas atingidas na criopreservação. Autores têm relatado sucesso neste procedimento após a infusão desses produtos contaminados com o mínimo de consequências clínicas.


The rate of microbial contamination of hematopoietic progenitor cell products from peripheral blood is low. In this study, we investigated the prevalence of positive blood cultures of hematopoietic progenitor cells from peripheral blood in a hemotherapy service. Of a total of 618 samples taken during the period from 2000 to 2007, 26 (4.2 percent) were contaminated by bacteria. Staphylococcus coagulase-negative was the predominant bacterium isolated in blood cultures. Pre- and post-infusion antibiotic therapy was established depending on the microorganism and antibiogram, whereas in five out of twelve contaminated infusions, no antibiotics were administered prophylactically. Febrile episodes were observed in seven patients (58 percent), while five (42 percent) did not suffer from fever. Of the twelve contaminated infusions performed, six (50 percent) of the samples had positive blood cultures after thawing, while the others (50 percent) were negative. This is due to the bactericidal properties of DMSO, phagocytosis-active cells and the extremely low temperatures during cryopreservation. Authors have reported success in the procedure after the infusion of contaminated products with minimal clinical consequences.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA