Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Burn Care Res ; 41(4): 871-877, 2020 07 03.
Artigo em Inglês | MEDLINE | ID: mdl-32141505

RESUMO

In sepsis and burns, ascorbic acid (AA) is hypothesized advantageous during volume resuscitation. There is uncertainty regarding its safety and dosing. This study evaluated high dose AA (HDAA: 66 mg/kg/h for 24 hours) versus low dose AA (LDAA: 3.5 g/days) administration during the first 24 hours in severely burned adults. We conducted a retrospective study comparing fluid administration before and after switching from low dose to HDAA in severely burned adults. A total of 38 adults with burns >20% TBSA, who received either HDAA or LDAA were included in this retrospective study. AA serum concentrations were quantified at 0, 24, and 72 hours postburn. HDAA impact on hemodynamics, acid-base homeostasis, acute kidney injury, vasopressor use, resuscitation fluid requirement, urinary output, and the incidence of adverse effects was evaluated; secondary clinical outcomes were analyzed. AA plasma levels were 10-fold elevated in the LDAA and 150-fold elevated in the HDAA group at 24 hours and decreased in both groups afterwards. HDAA was not associated with a significantly increased risk of any complications. A significant reduction in colloid fluid requirements was noted (LDAA: 947 ± 1722 ml/24 hours vs HDAA: 278 ± 667 ml/24 hours, P = 0.029). Other hemodynamic and resuscitation measures, as well as secondary clinical outcomes were comparable between groups. HDAA was associated with higher AA levels and lower volumes of colloids in adults with severe burns. The rate of adverse events was not significantly higher in patients treated with HDAA. Future studies should consider prolonged administration of AA.


Assuntos
Antioxidantes/administração & dosagem , Ácido Ascórbico/administração & dosagem , Queimaduras/complicações , Choque/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Antioxidantes/análise , Ácido Ascórbico/sangue , Coloides/administração & dosagem , Creatinina/análise , Relação Dose-Resposta a Droga , Feminino , Hidratação , Humanos , Infusões Intravenosas , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Terapia de Substituição Renal/estatística & dados numéricos , Ressuscitação , Estudos Retrospectivos , Choque/etiologia , Urina , Vasoconstritores/uso terapêutico , Adulto Jovem
2.
Surg Innov ; 23(3): 249-60, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26474605

RESUMO

BACKGROUND: Near-infrared indocyanine green video angiography (ICG-NIR-VA) has been introduced for free-flap surgery and may provide intraoperative flap designing as well as postoperative monitoring. Nevertheless, the technique has not been established in clinical routine because of controversy over benefits. Improved technical features of the novel Visionsense ICG-NIR-VA surgery system are promising to revisit the field of application. It features a unique real-time fusion image of simultaneous NIR and white light visualization, with highlighted perfusion, including a color-coded perfusion flow scale for optimized anatomical understanding. METHODS: In a feasibility study, the Visionsense ICG-NIR-VA system was applied during 10 free-flap surgeries in 8 patients at our center. Indications included anterior lateral thigh (ALT) flap (n = 4), latissimus dorsi muscle flap (n = 1), tensor fascia latae flap (n = 1), and two bilateral deep inferior epigastric artery perforator flaps (n = 4). The system was used intraoperatively and postoperatively to investigate its impact on surgical decision making and to observe perfusion patterns correlated to clinical monitoring. RESULTS: Visionsense ICG-NIR-VA aided assessing free-flap design and perfusion patterns in all cases and correlated with clinical observations. Additional interventions were performed in 2 cases (22%). One venous anastomosis was revised, and 1 flap was redesigned. Indicated by ICG-NIR-VA, 1 ALT flap developed partial flap necrosis (11%). CONCLUSIONS: The Visionsense ICG-NIR-VA system allowed a virtual view of flap perfusion anatomy by fusion imaging in real-time. The system improved decision making for flap design and surgical decisions. Clinical and ICG-NIR-VA parameters correlated. Its future implementation may aid in improving outcomes for free-flap surgery, but additional experience is needed to define its final role.


Assuntos
Angiofluoresceinografia , Retalhos de Tecido Biológico/irrigação sanguínea , Verde de Indocianina , Imagem Óptica/métodos , Imagem de Perfusão/métodos , Procedimentos de Cirurgia Plástica/métodos , Idoso , Estudos de Viabilidade , Feminino , Seguimentos , Retalhos de Tecido Biológico/transplante , Rejeição de Enxerto , Sobrevivência de Enxerto , Humanos , Masculino , Pessoa de Meia-Idade , Retalho Miocutâneo/irrigação sanguínea , Retalho Miocutâneo/transplante , Procedimentos de Cirurgia Plástica/efeitos adversos , Estudos de Amostragem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA