Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Respiration ; 103(9): 593-600, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38810608

RESUMO

Based on the assessment of new evidence, the World Health Organization (WHO) updated its guidelines for the treatment of drug-resistant tuberculosis (TB) in December 2022. The new recommendations and the latest study data made it necessary to update the existing guideline on the treatment of at least rifampicin-resistant TB (RR-TB) for the German-speaking countries, replacing the respective chapters of the treatment guidelines published in 2022. A shortened treatment of proven RR-TB and multidrug-resistant TB for at least 6 months using the fixed and non-modifiable drug combination of bedaquiline, pretomanid, linezolid, and moxifloxacin (BPaLM) is now also recommended for Austria, Germany, and Switzerland under certain conditions considering the existing barriers for the implementation of the new treatment regimen. For the treatment of pre-extensively drug-resistant (pre-XDR-) TB, an individualized treatment for 18 months continues to be the primary recommendation. The non-modifiable drug combination of bedaquiline, pretomanid, and linezolid (BPaL) may be used alternatively in selected pre-XDR-TB cases, provided that all prerequisites are met. The necessary requirements for using BPaLM and BPaL are presented in detail in this amendment to the consensus-based TB treatment guideline for adult patients.


Assuntos
Antituberculosos , Tuberculose Extensivamente Resistente a Medicamentos , Rifampina , Tuberculose Resistente a Múltiplos Medicamentos , Humanos , Antituberculosos/farmacologia , Antituberculosos/uso terapêutico , Áustria , Diarilquinolinas/farmacologia , Diarilquinolinas/uso terapêutico , Tuberculose Extensivamente Resistente a Medicamentos/tratamento farmacológico , Alemanha , Linezolida/farmacologia , Linezolida/uso terapêutico , Moxifloxacina/farmacologia , Moxifloxacina/uso terapêutico , Rifampina/farmacologia , Rifampina/uso terapêutico , Suíça , Tuberculose Resistente a Múltiplos Medicamentos/tratamento farmacológico
2.
Respiration ; 102(11): 934-943, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37899038

RESUMO

BACKGROUND: Children exposed to a tuberculosis (TB) index case are at risk of TB infection and disease. OBJECTIVES: The aim of this study was to describe the proportion of child contacts who developed TB infection or disease after exposure and to assess the diagnostic pathways and adherence to current guidelines. METHODS: Retrospective observational study including children ≤16 years of age who had contact to a TB index case between January 2019 and July 2021. Analysis was stratified by age groups 0-4, 5-11, and 12-16 years. RESULTS: Of 401 TB-exposed children, data were available for 380 (95%). Of those, 7 (2%) were diagnosed with TB disease and 35 (9%) with TB infection. We identified several deviations in the management compared to recommendations in national Swiss guidelines: In the children aged 0-4 years, only 82% were examined with an immunodiagnostic test or a chest radiography within 2 weeks after last contact. Recommended prophylactic treatment was prescribed in 66% of the children only. In the children aged 5-11 years, 64% were tested with an immunodiagnostic test in a first examination and 75% in a second examination, 2 weeks and 2 months after last contact, respectively. CONCLUSIONS: Contact investigations of children exposed to a TB index case identified a significant proportion of children with TB infection and disease in a low TB incidence setting. We observed significant deviations from the guidelines in the contact investigations suggesting the need for improved implementation.


Assuntos
Tuberculose Latente , Tuberculose , Adolescente , Criança , Humanos , Fidelidade a Diretrizes , Tuberculose Latente/diagnóstico , Suíça/epidemiologia , Teste Tuberculínico , Tuberculose/diagnóstico , Tuberculose/epidemiologia , Estudos Retrospectivos
4.
PLoS One ; 17(7): e0271004, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35862391

RESUMO

BACKGROUND: Sleep apnea (SA) is a prevalent disorder characterized by recurrent events of nocturnal apnea originating from obstructive and/or central mechanisms. SA disrupts normal sleep and can lead to a series of complications when left untreated. SA results in intermittent hypoxia which has an impact on the cardio- and cerebrovascular system. Hospitalized patients with SA typically have a greater burden of comorbidity, a longer length of hospital stay, but may show an improvement of in-hospital mortality compared to patients without diagnosed SA. The reason for this survival benefit is controversial and we aimed to clarify this protective effect in the light of predictive factors including SA-associated comorbidities using a nation-wide hospitalization database. METHODS AND FINDINGS: Data were extracted from a nation-wide hospitalization database provided by the Swiss Federal Office for Statistics. Hospitalized patients with a SA co-diagnosis were extracted from the database together with a 1:1-matched control population without SA. Overall, 212'581 patients with SA were hospitalized in Switzerland between 2002 and 2018. Compared to the controls, SA cases had a longer median length of hospital stay (7 days; 95% CI: 3 to 15 vs. 4 days; 95% CI: 2 to 10) (p < 0.001) and a higher median number of comorbidities (8 comorbidities; IQR: 5 to 11 vs. 3 comorbidities; IQR: 1 to 6) (p < 0.001). The risk of in-hospital mortality was lower in the SA cases compared to the controls (OR: 0.73; 95% CI: 0.7 to 0.76; p < 0.001). SA was associated with a survival benefit in hospitalizations related to 28 of 47 conditions with the highest rate of in-hospital death. Sixty-three comorbidities were significantly over-represented in SA cases among which obesity, hypertension and anatomic nasal deviations were associated with a significant decrease of in-hospital mortality. CONCLUSIONS: Compared to matched controls, SA was associated with significant and relevant inpatient survival benefit in a number of most deadly conditions. Within SA-patients, associated comorbidities mostly correlated with a poorer prognosis, whereas obesity and hypertension were associated with an improved in-hospital mortality.


Assuntos
Hipertensão , Síndromes da Apneia do Sono , Estudos de Casos e Controles , Comorbidade , Mortalidade Hospitalar , Hospitalização , Hospitais , Humanos , Hipertensão/epidemiologia , Obesidade/epidemiologia , Síndromes da Apneia do Sono/epidemiologia
5.
Swiss Med Wkly ; 151: w30041, 2021 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-34495608

RESUMO

BACKGROUND: Numerous ECG alterations due to pneumothorax have been reported. The objective of the study was to establish the presence of ECG changes associated with pneumothorax in the literature, and in a cohort of patients with proven pneumothorax compared with age- and sex-matched healthy controls. METHODS: A systematic review for ECG alterations associated with pneumothorax was performed. We then reviewed our hospital database for patients with pneumothorax and identified all patients with an ECG available at this time. The retrieved ECG alterations in the systematic review were identified in our pneumothorax patients and compared with a healthy sex- and age-matched control group. Accordingly, we calculated sensitivity and specificity for all alterations. RESULTS: Seventeen ECG alterations were found and defined from the systematic review. Our pneumothorax cohort consisted of 82 pneumothorax patients and 82 control patients. Specificity was mostly more than 90%, but sensitivities were low. Phasic R voltage (pneumothorax group 25.6% vs control group 1.2%), T-wave inversion (31.7% vs 2.4%), prolonged QTc (11.0% vs 2.4%), right axis deviation (14.6% vs 3.6%) and QRS voltage ratio in aVF/I >2 (41.5% vs 22.0%) were significantly more frequent in pneumothorax patients compared with controls. CONCLUSION: The sensitivity of published ECG signs in predicting pneumothorax in our cohort was low, which means that ECG findings are an unsuitable tool for pneumothorax screening. However, presence of these ECG signs might raise a suspicion of pneumothorax in patients presenting with dyspnoea, or unclear chest discomfort.


Assuntos
Pneumotórax , Arritmias Cardíacas , Estudos de Casos e Controles , Dispneia , Eletrocardiografia , Humanos , Pneumotórax/diagnóstico
6.
Clin Cardiol ; 44(9): 1276-1285, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34219245

RESUMO

BACKGROUND: The new 2018 pulmonary hypertension (PH) definition includes a lower mean pulmonary artery pressure (mPAP) cut-off (>20 mmHg rather than ≥25 mmHg) and the compulsory requirement of a pulmonary vascular resistance (PVR) ≥3 Wood units (WU) to define precapillary PH. We assessed the clinical impact of the 2018 compared to the 2015 PH definition in aortic stenosis (AS) patients undergoing aortic valve replacement (AVR). METHODS: Severe AS patients (n = 487) undergoing pre-AVR right heart catheterization were classified according to the 2015 and 2018 definitions. Post-AVR mortality (median follow-up 44 months) was assessed. RESULTS: Based on the 2015 definition, 66 (13%) patients exhibited combined pre and postcapillary PH (CpcPH), 116 (24%) isolated post-capillary PH (IpcPH), 28 (6%) precapillary PH, and 277 (57%) no PH at all. Overall, 52 (11%) patients were reclassified: 23 no PH into IpcPH; 8 no PH into precapillary PH; 20 precapillary PH into no PH; 1 CpcPH into IpcPH. By the 2015 definition, only CpcPH patients displayed increased mortality, whereas by the 2018 definition, precapillary PH patients also experienced higher mortality than those without PH. Among the PH definition components, PVR ≥3 WU was the strongest predictor of death (hazard ratio > 4). CONCLUSIONS: In severe AS, a higher number of IpcPH patients are diagnosed by the 2018 definition, even though they have the same prognosis as those without PH. Patients with true precapillary PH are more accurately identified by the 2018 definition that includes a pulmonary vascular disease criterion, that is, PVR ≥3 WU, a strong mortality predictor.


Assuntos
Estenose da Valva Aórtica , Hipertensão Pulmonar , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco , Humanos , Hipertensão Pulmonar/diagnóstico , Estudos Retrospectivos , Resistência Vascular
8.
Respiration ; 100(4): 328-338, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33540413

RESUMO

BACKGROUND: In patients with obstructive sleep apnea syndrome (OSAS), the preference-based, health-related quality of life in terms of utility has not been extensively studied. OBJECTIVE: To address this point, we compared the performance of different instruments assessing utility in patients with OSAS undergoing continuous positive airway pressure (CPAP) therapy. MATERIALS AND METHODS: Data of 208 patients with OSAS (28 women, mean ± SE age 54.4 ± 0.7 years, apnea-hypopnea index (AHI) 51.9 ± 1.8/h, Epworth sleepiness score 13.4 ± 0.2) participating in a randomized trial of different CPAP modalities over 2 years were analyzed. Evaluations included sleep studies, Epworth sleepiness scale, and several utility instruments that measure subjective health preference on a scale ranging from 1 (most preferred and perfect health) to 0 (least preferred and very poor health). RESULTS: After 2 years of CPAP therapy, the mean ± SE AHI was 6.7 ± 1.5/h and Epworth score 7.9 ± 0.4, both p < 0.001 versus baseline. Baseline utilities and changes (95% confidence interval) after 2 years of CPAP therapy were EuroQol 5-dimensions 0.79 ± 0.01, 0.02 (0.00-0.05, p = 0.064); short-form 6-dimension medical outcome questionnaire 0.72 ± 0.01, 0.06 (0.04-0.08, p < 0.001); Euro-thermometer visual analog scale 0.70 ± 0.01, 0.09 (0.07-0.12, p < 0.001); time trade-off 0.82 ± 0.01, 0.03 (0.01-0.06, p = 0.002); and standard gamble 0.82 ± 0.01, -0.01 (-0.03 to 0.02, p = 0.712). CONCLUSION: The short-form 6-dimensions questionnaire, the Euro-thermometer, and the time trade-off instruments reflected the major clinical improvements in OSAS, while the EuroQoL 5-dimensions and standard gamble tests were not sensitive to CPAP effects. These results indicate that the evaluation of utility of a treatment for OSAS depends critically on the instrument used, which is important from an individual and societal perspective.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/métodos , Autoavaliação Diagnóstica , Qualidade de Vida , Apneia Obstrutiva do Sono , Análise Custo-Benefício , Feminino , Expectativa de Vida Saudável , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados da Assistência ao Paciente , Preferência do Paciente , Anos de Vida Ajustados por Qualidade de Vida , Apneia Obstrutiva do Sono/economia , Apneia Obstrutiva do Sono/psicologia , Apneia Obstrutiva do Sono/terapia , Resultado do Tratamento , Escala Visual Analógica
9.
Respiration ; : 1-36, 2020 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-33302274

RESUMO

Long-term mechanical ventilation is a well-established treatment for chronic hypercapnic respiratory failure (CHRF). It is aimed at improving CHRF-related symptoms, health-related quality of life, survival, and decreasing hospital admissions. In Switzerland, long-term mechanical ventilation has been increasingly used since the 1980s in hospital and home care settings. Over the years, its application has considerably expanded with accumulating evidence of beneficial effects in a broad range of conditions associated with CHRF. Most frequent indications for long-term mechanical ventilation are chronic obstructive pulmonary disease, obesity hypoventilation syndrome, neuromuscular and chest wall diseases. In the current consensus document, the Special Interest Group of the Swiss Society of Pulmonology reviews the most recent scientific literature on long-term mechanical ventilation and provides recommendations adapted to the particular setting of the Swiss healthcare system with a focus on the practice of non-invasive and invasive home ventilation in adults.

10.
Sensors (Basel) ; 20(1)2020 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-31947905

RESUMO

Sleep apnea (SA) is a prevalent disorder diagnosed by polysomnography (PSG) based on the number of apnea-hypopnea events per hour of sleep (apnea-hypopnea index, AHI). PSG is expensive and technically complex; therefore, its use is rather limited to the initial diagnostic phase and simpler devices are required for long-term follow-up. The validity of single-parameter wearable devices for the assessment of sleep apnea severity is still debated. In this context, a wearable electrocardiogram (ECG) acquisition system (ECG belt) was developed and its suitability for the classification of sleep apnea severity was investigated using heart rate variability analysis with or without data pre-filtering. Several classification algorithms were compared and support vector machine was preferred due to its simplicity and overall performance. Whole-night ECG signals from 241 patients with a suspicion of sleep apnea were recorded using both the ECG belt and patched ECG during PSG recordings. 65% of patients had an obstructive sleep apnea and the median AHI was 21 [IQR: 7-40] h - 1 . The classification accuracy obtained from the ECG belt (accuracy: 72%, sensitivity: 70%, specificity: 74%) was comparable to the patched ECG (accuracy: 74%, sensitivity: 88%, specificity: 61%). The highest classification accuracy was obtained for the discrimination between individuals with no or mild SA vs. moderate to severe SA. In conclusion, the ECG belt provided signals comparable to patched ECG and could be used for the assessment of sleep apnea severity, especially during follow-up.


Assuntos
Técnicas Biossensoriais , Eletrocardiografia , Monitorização Fisiológica/métodos , Síndromes da Apneia do Sono/fisiopatologia , Adulto , Algoritmos , Feminino , Frequência Cardíaca/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia/métodos , Índice de Gravidade de Doença , Síndromes da Apneia do Sono/classificação , Síndromes da Apneia do Sono/diagnóstico , Máquina de Vetores de Suporte , Dispositivos Eletrônicos Vestíveis
11.
Sensors (Basel) ; 19(15)2019 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-31370241

RESUMO

Sleep monitoring in an unattended home setting provides important information complementing and extending the clinical polysomnography findings. The validity of a wearable textile electrocardiography (ECG)-belt has been proven in a clinical setting. For evaluation in a home setting, ECG signals and features were acquired from 12 patients (10 males and 2 females, showing an interquartile range for age of 48-59 years and for body mass indexes (BMIs) of 28.0-35.5) over 28 nights. The signal quality was assessed by artefacts detection, signal-to-noise ratio, and Poincaré plots. To assess the validity, the data were compared to previously reported data from the clinical setting. It was found that the artefact percentage was slightly reduced for the ECG-belt from 9.7% ± 14.7% in the clinical setting, to 7.5% ± 10.8% in the home setting. The signal-to-noise ratio was improved in the home setting and reached similar values to the gel electrodes in the clinical setting. Finally, it was found that for artefact percentages above 3%, Poincaré plots are instrumental to evaluate the origin of artefacts. In conclusion, the application of the ECG-belt in a home setting did not result in a reduction in signal quality compared to the ECG-belt used in the clinical setting, and thus provides new opportunities for patient pre-screening or follow-up.


Assuntos
Eletrocardiografia/métodos , Monitorização Fisiológica , Polissonografia/métodos , Síndromes da Apneia do Sono/diagnóstico , Índice de Massa Corporal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Processamento de Sinais Assistido por Computador , Razão Sinal-Ruído , Sono/fisiologia , Síndromes da Apneia do Sono/fisiopatologia , Têxteis , Dispositivos Eletrônicos Vestíveis
12.
Ann Am Thorac Soc ; 16(12): 1550-1557, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31310575

RESUMO

Rationale: Continuous positive airway pressure (CPAP) is the standard treatment for the obstructive sleep apnea syndrome (OSAS), but long-term adherence remains a challenge. In a pilot study, we observed that telemedicine combined with telemetrically triggered interventions was associated with improved CPAP adherence in the first month of treatment.Objectives: In the current randomized, controlled phase III trial, we aimed to collect pivotal data for the use of telemedicine in CPAP treatment of patients with OSAS.Methods: Symptomatic patients with OSAS were randomized to a telemedicine or control arm and initiated CPAP treatment. Phone calls were triggered in the telemedicine group during the first month of treatment upon either poor use or excessive mask leakage. Patients were followed for 6 months. Measures of CPAP use at 6 months were the main study endpoints.Results: Among 240 patients enrolled, 71 (30%) discontinued CPAP treatment over the course of the study. The primary outcome measure, the proportion of nights with CPAP use greater than 1 hour, was not statistically different in the telemedicine group (92.0%) versus the control group (88.2%) (P = 0.565). The daily hours of CPAP use at 6 months also did not differ significantly between the telemedicine group (5.6 h) and the control group (4.8 h) (P = 0.663). However, in a post hoc analysis, telemedicine led to increased device use in a subgroup of patients with a mild form of disease (5.6 h vs. 3.4 h; P = 0.026). The telemedicine-based intervention had a positive impact on sleep-related quality of life as measured with the Quebec Sleep Questionnaire (5.55 vs. 5.49 at 1 mo [P = 0.020]; 5.61 vs. 5.46 at 6 mo [P = 0.013]).Conclusions: A telemetrically triggered intervention in the first month of treatment did not improve CPAP use in the study population overall, but it had positive effects in patients with a mild form of OSAS and led to an improvement in sleep-related quality of life.Clinical trial registered with www.clinicaltrials.gov (NCT01715194).


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Cooperação do Paciente/estatística & dados numéricos , Apneia Obstrutiva do Sono/terapia , Telemedicina , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Polissonografia , Estudos Prospectivos , Melhoria de Qualidade , Qualidade de Vida , Medição de Risco , Índice de Gravidade de Doença , Apneia Obstrutiva do Sono/diagnóstico , Suíça
13.
Sensors (Basel) ; 19(11)2019 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-31141955

RESUMO

Even for 1-lead electrocardiography (ECG), single-use gel conductive electrodes are employed in a clinical setting. However, gel electrodes show limited applicability for long-term monitoring due to skin irritation and detachment. In the present study, we investigated the validity of a textile ECG-belt suitable for long-term measurements in clinical use. In order to assess the signal quality and validity of the ECG-belt during sleep, 242 patients (186 males and 56 females, age 52 (interquartile range 42-60) years, body mass index 29 (interquartile range 26-33) kg·m-2) with suspected sleep apnoea underwent overnight polysomnography including standard 1-lead ECG recording. The single intervals between R-peaks (RR-intervals) were calculated from the ECG-signals. We found a mean difference for average RR-intervals of -2.9 ms, a standard error of estimate of 0.39%, as well as a Pearson r of 0.91. Furthermore, we found that the validity of the ECG-belt decreases when lying on the side, which was potentially due to the fitting of the belt. In conclusion, the validity of RR-interval measurements using the ECG-belt is high and it may be further improved for future applications by optimizing wear fitting.


Assuntos
Eletrocardiografia , Monitorização Fisiológica , Têxteis , Adulto , Artefatos , Eletrodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Postura , Razão Sinal-Ruído , Síndromes da Apneia do Sono/diagnóstico , Análise de Ondaletas
14.
Lancet Infect Dis ; 18(4): 431-440, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29326013

RESUMO

BACKGROUND: The risk of tuberculosis outbreaks among people fleeing hardship for refuge in Europe is heightened. We describe the cross-border European response to an outbreak of multidrug-resistant tuberculosis among patients from the Horn of Africa and Sudan. METHODS: On April 29 and May 30, 2016, the Swiss and German National Mycobacterial Reference Laboratories independently triggered an outbreak investigation after four patients were diagnosed with multidrug-resistant tuberculosis. In this molecular epidemiological study, we prospectively defined outbreak cases with 24-locus mycobacterial interspersed repetitive unit-variable number tandem repeat (MIRU-VNTR) profiles; phenotypic resistance to isoniazid, rifampicin, ethambutol, pyrazinamide, and capreomycin; and corresponding drug resistance mutations. We whole-genome sequenced all Mycobacterium tuberculosis isolates and clustered them using a threshold of five single nucleotide polymorphisms (SNPs). We collated epidemiological data from host countries from the European Centre for Disease Prevention and Control. FINDINGS: Between Feb 12, 2016, and April 19, 2017, 29 patients were diagnosed with multidrug-resistant tuberculosis in seven European countries. All originated from the Horn of Africa or Sudan, with all isolates two SNPs or fewer apart. 22 (76%) patients reported their travel routes, with clear spatiotemporal overlap between routes. We identified a further 29 MIRU-VNTR-linked cases from the Horn of Africa that predated the outbreak, but all were more than five SNPs from the outbreak. However all 58 isolates shared a capreomycin resistance-associated tlyA mutation. INTERPRETATION: Our data suggest that source cases are linked to an M tuberculosis clone circulating in northern Somalia or Djibouti and that transmission probably occurred en route before arrival in Europe. We hypothesise that the shared mutation of tlyA is a drug resistance mutation and phylogenetic marker, the first of its kind in M tuberculosis sensu stricto. FUNDING: The Swiss Federal Office of Public Health, the University of Zurich, the Wellcome Trust, National Institute for Health Research (NIHR) Oxford Biomedical Research Centre (BRC), the Medical Research Council, BELTA-TBnet, the European Union, the German Center for Infection Research, and Leibniz Science Campus Evolutionary Medicine of the Lung (EvoLUNG).


Assuntos
Emigrantes e Imigrantes , Mycobacterium tuberculosis/classificação , Mycobacterium tuberculosis/isolamento & purificação , Tuberculose Resistente a Múltiplos Medicamentos/epidemiologia , Adolescente , Adulto , África , Animais , Antituberculosos/farmacologia , Criança , Análise por Conglomerados , Transmissão de Doença Infecciosa , Europa (Continente)/epidemiologia , Feminino , Genoma Bacteriano , Humanos , Masculino , Testes de Sensibilidade Microbiana , Repetições Minissatélites , Epidemiologia Molecular , Tipagem Molecular , Mycobacterium tuberculosis/efeitos dos fármacos , Mycobacterium tuberculosis/genética , Polimorfismo de Nucleotídeo Único , Sequenciamento Completo do Genoma , Adulto Jovem
15.
Thorax ; 73(2): 174-184, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28982804

RESUMO

BACKGROUND: The obstructive sleep apnoea syndrome (OSAS) is conventionally treated by continuous positive airway pressure set at a fixed level (fCPAP). Automatic mask pressure adjustment (autoCPAP) is increasingly used during home therapy. We investigated whether autoCPAP is equivalent to fCPAP in improving sleepiness in patients with OSAS in the long-term. METHODS: In this multicentre equivalence trial, 208 patients with OSAS, with median Epworth sleepiness score (ESS) 13, apnoea/hypopnoea index 48.4/hour, were randomised to treatment with autoCPAP (5-15 mbar) or fCPAP (pressure set at the 90th percentile applied by autoCPAP during 2-4 weeks adaptation). Coprimary outcomes were changes in subjective and objective sleepiness from baseline to 2 years after treatment. Equivalence ranges were ±2 points in ESS and ±3 min sleep resistance time evaluated by recording responses to light signals. RESULTS: At 2 years, in the intention to treat analysis, the reduction in sleepiness versus pretreatment baseline was similar in patients using autoCPAP (n=113, mean ESS-change -6.3, 95% CI -7.1 to -5.5; sleep resistance time +8.3 min, +6.9 to +9.7) and fCPAP (n=95, mean ESS-change -6.2, 95% CI -7.0 to -5.3; sleep resistance time +6.3 min, +4.7 to +7.8). The 95% CI of difference in ESS-reduction between autoCPAP and fCPAP was -0.9 to +1.4 and the 95% CI of difference in increase in sleep resistance time was -2.6 to +1.0 min. Blood pressure reduction and OSAS-related costs were similar between groups. CONCLUSIONS: AutoCPAP and fCPAP are equivalent within prespecified ranges in improving subjective and objective sleepiness in patients with OSAS over the course of 2 years. Costs of these treatments are similar. TRIAL REGISTRATION NUMBER: ClinicalTrials.gov NCT00280800.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/métodos , Apneia Obstrutiva do Sono/terapia , Adolescente , Adulto , Idoso , Estudos de Coortes , Estudos de Equivalência como Asunto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
16.
Int J Tuberc Lung Dis ; 21(6): 601, 2017 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-28482952
17.
Swiss Med Wkly ; 147: w14395, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28102878

RESUMO

Pulmonary hypertension associated with left-sided heart disease (PH-LHD) is the most common type of pulmonary hypertension. In patients with left-sided heart disease, the presence of pulmonary hypertension is typically a marker of more advanced disease, more severe symptoms, and worse prognosis. In contrast to pulmonary arterial hypertension, PH-LHD is characterised by an elevated pulmonary artery wedge pressure (postcapillary pulmonary hypertension) without or with an additional precapillary component (isolated postcapillary versus combined postcapillary and precapillary pulmonary hypertension). Transthoracic echocardiography is the primary nonin-vasive imaging tool to estimate the probability of pulmonary hypertension and to establish a working diagnosis on the mechanism of pulmonary hyperten-sion. However, right heart catheterisation is always required if significant pulmonary hypertension is sus-pected and exact knowledge of the haemodynamic constellation is necessary. The haemodynamic con-stellation (mean pulmonary artery pressure, mean pulmonary artery wedge pressure, left ventricular end-diastolic pressure) in combination with clinical infor-mation and imaging findings (mainly echocardiog-raphy, coronary angiography and cardiac magnetic resonance imaging) will usually allow the exact mech-anism underlying PH-LHD to be defined, which is a prerequisite for appropriate treatment. The general principle for the management of PH-LHD is to treat the underlying left-sided heart disease in an optimal man-ner using drugs and/or interventional or surgical ther-apy. There is currently no established indication for pulmonary arterial hypertension-specific therapies in PH-LHD, and specific therapies may even cause harm in patients with PH-LHD.


Assuntos
Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/fisiopatologia , Disfunção Ventricular Esquerda/complicações , Cateterismo Cardíaco , Hemodinâmica , Humanos , Hipertensão Pulmonar/epidemiologia , Pressão Propulsora Pulmonar/fisiologia , Resistência Vascular/fisiologia , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/fisiopatologia
18.
Swiss Med Wkly ; 146: w14363, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27679963

RESUMO

In 2015, the international guidelines for diagnosis and treatment of pulmonary hypertension (PH) were updated. Group 3 of the current classification includes PH associated with chronic obstructive pulmonary disease (COPD), interstitial lung disease (ILD), other pulmonary diseases with restrictive and obstructive pattern, sleep-disordered breathing, alveolar hypoventilation disorders, chronic exposure to high altitude, and developmental lung diseases [1]. PH associated with COPD and ILD is common but difficult to manage, as no long-term randomised controlled trial (RCT) has been conducted with specific pulmonary arterial hypertension (PAH) drugs in PH associated with COPD, and the one recent RCT in PH associated with ILD had to be stopped early due to a possible increased risk of death and side effects in the treatment group. Specific treatment may thus be harmful and may worsen gas exchange as a result of possible recruitment of less oxygenised areas, i.e. by increasing ventilation-perfusion mismatch. Management of PH patients with chronic lung diseases requires careful evaluation and understanding of pathophysiological mechanisms. Interestingly, mediators in PAH and in fibrotic lung disease show some overlaps. Several drugs effective in PAH have been evaluated for anti-fibrotic treatment in ILD, but until today without consistent success. While new drugs with anti-fibrotic effects are now accessible, a specific evidence-based treatment for PH in ILD or COPD with or without emphysema is not yet available.

19.
Clin Chim Acta ; 460: 152-63, 2016 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-27380998

RESUMO

Obstructive sleep apnea (OSA) is a common sleep-related breathing disorder associated with "cardiovascular stress", i.e. cardiovascular risk factors, cardiovascular diseases, and an increased risk of heart failure, stroke, and death. Experimental and clinical studies have characterized potential underlying mechanisms including biventricular dysfunction, atherosclerosis, and arrhythmia. Assessment of these cardiovascular features of OSA requires a spectrum of clinical tools including ECG, echocardiography, exercise testing, and angiography. In contrast to many cardiovascular diseases, the role of blood biomarkers to characterize cardiovascular function and cardiovascular risk in OSA is poorly defined. In the present review we summarize the available data on biomarkers potentially providing information on cardiovascular features in OSA patients without overt cardiovascular disease. The vast majority of studies on biomarkers of cardiovascular stress in OSA evaluated B-type natriuretic peptide (BNP)/N-terminal-B-type natriuretic peptide (NT-proBNP), and cardiac troponins (cTn). Although some studies found significant associations between these cardiac biomarkers and the presence and severity of OSA, data remain conflicting. Also, the detailed pathophysiological mechanisms underlying the link between OSA and hemodynamic cardiac stress (BNP/NT-proBNP) and cardiomyocyte damage (cTn) are poorly understood. Major research efforts are required to establish the clinical role of cardiovascular biomarkers in patients with OSA.


Assuntos
Doenças Cardiovasculares/diagnóstico , Apneia Obstrutiva do Sono/complicações , Biomarcadores/sangue , Doenças Cardiovasculares/etiologia , Humanos , Fatores de Risco , Apneia Obstrutiva do Sono/fisiopatologia , Estresse Fisiológico
20.
Tuberculosis (Edinb) ; 98: 7-12, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27156612

RESUMO

INTRODUCTION: Interferon-γ (IFN-γ) inducible protein 10kD (IP-10) and IFN-γ release assays (IGRAs) are immunodiagnostic tests aiming to identify the presence of specific cellular immune responses, interpreted as markers for latent infection with Mycobacterium tuberculosis. Incubation at higher temperatures could affect IFN-γ and IP-10 responsiveness in order to improve the performance of IP-10 release assays and IGRAs. AIM: The aim of this study was to assess the robustness of whole blood based IP-10 release assay and IGRAs and the effect of hyper-thermic incubation (39 °C) on the diagnostic accuracy of IP-10 release assay and IGRAs. RESULTS: We included 65 patients with confirmed pulmonary tuberculosis and 160 healthy controls from 6 European centres collaborating in the TBnet. In patients, IP-10 responses increased 1.07 (IQR 0.90-1.36) fold and IFN-γ responses decreased 0.88 (IQR 0.57-1.02) fold, with 39 °C compared to 37 °C incubation temperature. At 37 °C IGRA sensitivity was 85% and IP-10 sensitivity was 82%, whereas specificity was 97% for both tests (p > 0.8). These minor changes observed as a result of hyper-thermic incubation were not sufficient to impact IGRA and IP-10 release assay test performance. CONCLUSION: The performance of IGRA and IP-10 release assays is robust despite variations in the incubation temperature between 37 °C and 39 °C.


Assuntos
Quimiocina CXCL10/sangue , Testes de Liberação de Interferon-gama , Interferon gama/sangue , Tuberculose Latente/diagnóstico , Mycobacterium tuberculosis/imunologia , Manejo de Espécimes/métodos , Temperatura , Tuberculose Pulmonar/diagnóstico , Adulto , Área Sob a Curva , Biomarcadores/sangue , Estudos de Casos e Controles , Europa (Continente) , Feminino , Interações Hospedeiro-Patógeno , Humanos , Tuberculose Latente/sangue , Tuberculose Latente/imunologia , Masculino , Pessoa de Meia-Idade , Mycobacterium tuberculosis/patogenicidade , Valor Preditivo dos Testes , Estudos Prospectivos , Estabilidade Proteica , Curva ROC , Reprodutibilidade dos Testes , Tuberculose Pulmonar/sangue , Tuberculose Pulmonar/imunologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA