Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Artif Organs ; 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38546373

RESUMO

BACKGROUND: Ex vivo normothermic machine perfusion (NMP) is a promising tool for assessing an isolated kidney prior to transplantation. However, there is no consensus on the perfusate's optimal oxygen-carrying capacity to support renal function. To investigate the association of hemoglobin levels with renal function parameters, a retrospective analysis of isolated, normothermically, perfused porcine kidneys was performed. METHODS: Between 2015 and 2021, a total of 228 kidneys underwent 4 h of NMP with perfusates that varied in hemoglobin levels. A generalized linear model was used to determine the association of hemoglobin levels with time-weighted means of renal function markers, such as fractional sodium excretion (FENa) and creatinine clearance (CrCl). Stratified by baseline hemoglobin level (<4.5, 4.5-6, or >6 mmol/L), these markers were modeled over time using a generalized linear mixed-effects model. All models were adjusted for potential confounders. RESULTS: Until a hemoglobin level of around 5 mmol/L was reached, increasing hemoglobin levels were associated with superior FENa and CrCl. Thereafter, this association plateaued. When hemoglobin levels were categorized, hemoglobin <4.5 mmol/L was associated with worse renal function. Hemoglobin levels were neither significantly associated with proteinuria during NMP nor with ATP levels at the end of NMP. Hemoglobin levels >6 mmol/L showed no additional benefits in renal function. CONCLUSION: In conclusion, we found an association between baseline hemoglobin levels and superior renal function parameters, but not injury, during NMP of porcine kidneys. Furthermore, we show that performing a retrospective cohort study of preclinical data is feasible and able to answer additional questions, reducing the potential use of laboratory animals.

2.
Kidney Int Rep ; 8(10): 2008-2016, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37850026

RESUMO

Introduction: Transplant clinicians may disagree on whether or not to accept a deceased donor kidney offer. We investigated the interobserver variability between transplant nephrologists regarding organ acceptance and whether the use of a prediction model impacted their decisions. Methods: We developed an observational online survey with 6 real-life cases of deceased donor kidneys offered to a waitlisted recipient. Per case, nephrologists were asked to estimate the risk of adverse outcome and whether they would accept the offer for this patient, or for a patient of their own choice, and how certain they felt. These questions were repeated after revealing the risk of adverse outcome, calculated by a validated prediction model. Results: Sixty Dutch nephrologists completed the survey. The intraclass correlation coefficient of their estimated risk of adverse outcome was poor (0.20, 95% confidence interval [CI] 0.08-0.62). Interobserver agreement of the decision on whether or not to accept the kidney offer was also poor (Fleiss kappa 0.13, 95% CI 0.129-0.130). The acceptance rate before and after providing the outcome of the prediction model was significantly influenced in 2 of 6 cases. Acceptance rates varied considerably among transplant centers. Conclusion: In this study, the estimated risk of adverse outcome and subsequent decision to accept a suboptimal donor kidney varied greatly among transplant nephrologists. The use of a prediction model could influence this decision and may enhance nephrologists' certainty about their decision.

3.
Nephrol Dial Transplant ; 38(3): 787-796, 2023 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-36318454

RESUMO

BACKGROUND: To ensure optimal utilization of deceased donor kidneys, it is important to understand the precise reasons why kidneys are discarded. In this study we aimed to obtain a comprehensive overview of kidney utilization and discard during the entire donation process in the Netherlands. METHODS: In this retrospective cohort study we analysed kidney utilization of 3856 kidneys in the Netherlands between 1 January 2015 and 31 December 2020. For every kidney that was not transplanted, we determined the moment of and reason for discard through a unique case-by-case assessment. RESULTS: Kidney discard according to the traditional definition (procured but not transplanted) was 7.8%. However, when kidneys that seemed medically suitable at the beginning of the donation process were also included, many more potential donor kidneys were lost and the total non-utilization was 24.4%. Subjectively presumed impaired organ quality was responsible for 34.2% of all discarded kidneys. Two-thirds of kidneys discarded due to acute kidney injury (AKI) had only AKI stage 1 or 2. CONCLUSION: The classical definition of organ discard underestimates the non-utilization of deceased donor kidneys. Strategies to improve kidney utilization could be a revision of the maximum allowed agonal time in donation after circulatory death, careful consideration in reporting and accepting kidneys from donors with AKI and a prospectively filled registry of detailed organ discard reasons, including the 'silent' non-utilization before procurement.


Assuntos
Injúria Renal Aguda , Transplante de Rim , Obtenção de Tecidos e Órgãos , Humanos , Estudos Retrospectivos , Países Baixos , Seleção do Doador , Sobrevivência de Enxerto , Rim , Doadores de Tecidos
4.
Artif Organs ; 47(1): 105-116, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35996889

RESUMO

BACKGROUND: The shortage of donor organs for transplantation remains a worldwide problem. The utilization of suboptimal deceased donors enlarges the pool of potential organs, yet consequently, clinicians face the difficult decision of whether these sub-optimal organs are of sufficient quality for transplantation. Novel technologies could play a pivotal role in making pre-transplant organ assessment more objective and reliable. METHODS: Ex vivo normothermic machine perfusion (NMP) at temperatures around 35-37°C allows organ quality assessment in a near-physiological environment. Advanced magnetic resonance imaging (MRI) techniques convey unique information about an organ's structural and functional integrity. The concept of applying magnetic resonance imaging during renal normothermic machine perfusion is novel in both renal and radiological research and we have developed the first MRI-compatible NMP setup for human-sized kidneys. RESULTS: We were able to obtain a detailed and real-time view of ongoing processes inside renal grafts during ex vivo perfusion. This new technique can visualize structural abnormalities, quantify regional flow distribution, renal metabolism, and local oxygen availability, and track the distribution of ex vivo administered cellular therapy. CONCLUSION: This platform allows for advanced pre-transplant organ assessment, provides a new realistic tool for studies into renal physiology and metabolism, and may facilitate therapeutic tracing of pharmacological and cellular interventions to an isolated kidney.


Assuntos
Transplante de Rim , Preservação de Órgãos , Humanos , Perfusão/métodos , Preservação de Órgãos/métodos , Rim/diagnóstico por imagem , Transplante de Rim/métodos , Imageamento por Ressonância Magnética
5.
Transpl Int ; 34(9): 1643-1655, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34448269

RESUMO

Acceptance criteria of deceased donor organs have gradually been extended toward suboptimal quality, posing an urgent need for more objective pre-transplant organ assessment. Ex vivo normothermic machine perfusion (NMP) combined with magnetic resonance imaging (MRI) could assist clinicians in deciding whether a donor kidney is suitable for transplantation. Aim of this study was to characterize the regional distribution of perfusate flow during NMP, to better understand how ex vivo kidney assessment protocols should eventually be designed. Nine porcine and 4 human discarded kidneys underwent 3 h of NMP in an MRI-compatible perfusion setup. Arterial spin labeling scans were performed every 15 min, resulting in perfusion-weighted images that visualize intrarenal flow distribution. At the start of NMP, all kidneys were mainly centrally perfused and it took time for the outer cortex to reach its physiological dominant perfusion state. Calculated corticomedullary ratios based on the perfusion maps reached a physiological range comparable to in vivo observations, but only after 1 to 2 h after the start of NMP. Before that, the functionally important renal cortex appeared severely underperfused. Our findings suggest that early functional NMP quality assessment markers may not reflect actual physiology and should therefore be interpreted with caution.


Assuntos
Rim , Preservação de Órgãos , Animais , Circulação Extracorpórea , Humanos , Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética , Perfusão , Suínos
6.
MAGMA ; 33(1): 49-61, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31879853

RESUMO

Kidney transplantation has developed into a widespread procedure to treat end stage renal failure, with transplantation results improving over the years. Postoperative complications have decreased over the past decades, but are still an important cause of morbidity and mortality. Early accurate diagnosis and treatment is the key to prevent renal allograft impairment or even graft loss. Ideally, a diagnostic tool should be able to detect post-transplant renal dysfunction, differentiate between the different causes and monitor renal function during and after therapeutic interventions. Non-invasive imaging modalities for diagnostic purposes show promising results. Magnetic resonance imaging (MRI) techniques have a number of advantages, such as the lack of ionizing radiation and the possibility to obtain relevant tissue information without contrast, reducing the risk of contrast-induced nephrotoxicity. However, most techniques still lack the specificity to distinguish different types of parenchymal diseases. Despite some promising outcomes, MRI is still barely used in the post-transplantation diagnostic process. The aim of this review is to survey the current literature on the relevance and clinical applicability of diagnostic MRI modalities for the detection of various types of complications after kidney transplantation.


Assuntos
Falência Renal Crônica/complicações , Falência Renal Crônica/diagnóstico por imagem , Transplante de Rim/efeitos adversos , Imageamento por Ressonância Magnética/tendências , Complicações Pós-Operatórias/diagnóstico por imagem , Animais , Biomarcadores/metabolismo , Meios de Contraste , Rejeição de Enxerto , Sobrevivência de Enxerto , Humanos , Hidronefrose , Incidência , Inflamação , Falência Renal Crônica/cirurgia , Túbulos Renais/diagnóstico por imagem , Necrose/diagnóstico por imagem , Oxigênio/metabolismo , Perfusão , Radiação Ionizante , Infecções Urinárias/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA