Clin Chem Lab Med ; 2024 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-39389923

RESUMO

European Union (EU) regulations on in vitro diagnostics (IVD) and on serious cross-border threats to health provide for the establishment of European Reference Laboratories (EURLs) and their harmonization and cooperation with National Reference Laboratories (NRLs). While the EURLs under the IVD Regulation will be operational by 1 October 2024, the EURLs under the Regulation on serious cross-border threats to health will be operational by January 2025. Although NRLs may have been operating for a long time on the basis of national legislation, they should now cooperate with each other and with EURLs in a network of centers of excellence for the authorization and post-market surveillance of IVDs and for the epidemiological surveillance and control of communicable diseases. The term "reference laboratory" has long been used colloquially to refer to many kinds of laboratories, regardless of their tasks, competencies, responsibilities and designation. A literature search and analysis confirmed this by showing that a considerable proportion of scientific publications in 2024 use the term "reference laboratory" inappropriately. In order to clarify the roles and functioning of EURLs and NRLs, we have evaluated the relevant current EU provisions and compared the findings with those of reference laboratories designated by other organizations, calibration (reference) laboratories and referral laboratories, which are simply referred to as "reference laboratories". With the forthcoming implementation of the EU regulations, at least the goals of providing safe and high-quality IVDs and adequate public health surveillance for communicable diseases appear to be achievable.

2.
J Clin Virol ; 165: 105521, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37302248

RESUMO

BACKGROUND: European legislation defines as "near-patient testing" (NPT) what is popularly and in other legislations specified as "point-of-care testing" (POCT). Systems intended for NPT/POCT use must be characterized by independence from operator activities during the analytic procedure. However, tools for evaluating this are lacking. We hypothesized that the variability of measurement results obtained from identical samples with a larger number of identical devices by different operators, expressed as the method-specific reproducibility of measurement results reported in External Quality Assessment (EQA) schemes, is an indicator for this characteristic. MATERIALS AND METHODS: Legal frameworks in the EU, the USA and Australia were evaluated about their requirements for NPT/POCT. EQA reproducibility of seven SARS-CoV-2-NAAT systems, all but one designated as "POCT", was calculated from variabilities in Ct values obtained from the respective device types in three different EQA schemes for virus genome detection. RESULTS: A matrix for characterizing test systems based on their technical complexity and the required operator competence was derived from requirements of the European In Vitro Diagnostic Regulation (IVDR) 2017/746. Good EQA reproducibility of the measurement results of the test systems investigated implies that different users in different locations have no recognizable influence on their measurement results. CONCLUSION: The fundamental suitability of test systems for NPT/POCT use according to IVDR can be easily verified using the evaluation matrix presented. EQA reproducibility is a specific characteristic indicating independence from operator activities of NPT/POCT assays. EQA reproducibility of other systems than those investigated here remains to be determined.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , Reprodutibilidade dos Testes , COVID-19/diagnóstico , Sistemas Automatizados de Assistência Junto ao Leito , Técnicas de Amplificação de Ácido Nucleico
3.
Clin Chem Lab Med ; 56(12): 2039-2046, 2018 11 27.
Artigo em Inglês | MEDLINE | ID: mdl-30016273

RESUMO

Background ISO 9001 and ISO 15189 have been established as continuative models for quality systems beyond national laws, mandatory standards and guidelines of expert associations regarding analytical and organisational performance of medical laboratories and transfusion services. Although widely used, their impact on laboratory performance has not been investigated. Methods We retrospectively analysed the results of 167 laboratories in 59 distributions of the Austrian red cell immunohaematology external quality assessment (EQA) scheme in the years 1999-2017. The performance for each parameter and trends of individual participants were compared with respect to certification or accreditation status of participants' quality systems and to laboratory type. Results Considering more than 52,000 EQA results, the absence or presence of a laboratory quality management system showed different error rates. Laboratories with ISO 9001 or ISO 15189 certification/accreditation had 0.7% incorrect results, while this rate was doubled without such quality systems (1.4%, p=0.0002). Statistically significant error reductions were seen upon ISO 9001/ISO 15189 implementation (1.3% before vs. 0.7% after; p=0.0468). Transfusion services had fewer errors (0.9%) compared to hospital and independent laboratories (both 1.2%). Conclusions Implementation and maintenance of quality systems according to ISO 9001 or ISO 15189 as well as laboratory specialisation result in better analytical performance as can be seen in immunohaematology EQA results. The conclusion is that these results apply to other laboratory tests and perhaps to other areas of health care.


Assuntos
Alergia e Imunologia/normas , Hematologia/normas , Laboratórios/normas , Garantia da Qualidade dos Cuidados de Saúde/normas , Áustria , Humanos , Controle de Qualidade , Estudos Retrospectivos
4.
Int J Cardiol ; 168(2): 871-80, 2013 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-23164592

RESUMO

BACKGROUND: Originally reported to occur predominantly in younger women, idiopathic pulmonary arterial hypertension (IPAH) is increasingly diagnosed in elderly patients. We aimed to describe the characteristics of such patients and their survival under clinical practice conditions. METHODS: Prospective registry in 28 centers in 6 European countries. Demographics, clinical characteristics, hemodynamics, treatment patterns and outcomes of younger (18-65 years) and elderly (>65 years) patients with newly diagnosed IPAH (incident cases only) were compared. RESULTS: A total of 587 patients were eligible for analysis. The median (interquartile, [IQR]) age at diagnosis was 71 (16) years. Younger patients (n=209; median age, 54 [16] years) showed a female-to-male ratio of 2.3:1 whereas the gender ratio in elderly patients (n=378; median age, 75 [8] years) was almost even (1.2:1). Combinations of PAH drugs were widely used in both populations, albeit less frequently in older patients. Elderly patients were less likely to reach current treatment targets (6 min walking distance>400 m, functional class I or II). The survival rates 1, 2, and 3 years after the diagnosis of IPAH were lower in elderly patients, even when adjusted for age- and gender-matched survival tables of the general population (p=0.006 by log-rank analysis). CONCLUSIONS: In countries with an aging population, IPAH is now frequently diagnosed in elderly patients. Compared to younger patients, elderly patients present with a balanced gender ratio and different clinical features, respond less well to medical therapy and have a higher age-adjusted mortality. Further characterization of these patients is required. CLINICAL TRIALS REGISTRATION: NCT01347216.


Assuntos
Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/mortalidade , Sistema de Registros , Adulto , Idoso , Idoso de 80 Anos ou mais , Hipertensão Pulmonar Primária Familiar , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Taxa de Sobrevida/tendências