Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
JACC Clin Electrophysiol ; 10(7 Pt 2): 1689-1699, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39084743

RESUMO

BACKGROUND: Nonrandomized data suggest that longer diagnosis-to-ablation time (DAT) is associated with poorer outcomes; however, a recent randomized trial found no difference in recurrences when ablation was delayed by 12 months. OBJECTIVES: This study sought to assess the impact of DAT on atrial fibrillation (AF) recurrence in patients undergoing catheter ablation for persistent AF. METHODS: CAPLA (Effect of Catheter Ablation Using Pulmonary Vein Isolation With vs Without Posterior Left Atrial Wall Isolation on Atrial Arrhythmia Recurrence in Patients With Persistent Atrial Fibrillation: The CAPLA randomized clinical trial) was a multicenter trial that randomized patients with persistent AF to pulmonary vein isolation + posterior wall isolation or pulmonary vein isolation alone. Follow-up was 12 months. Outcomes were assessed after a 3-month blanking period. RESULTS: Median DAT in the 334 patients was 28 months (Q1-Q3: 12-66 months). Patients were divided into quartile groups: Q1 was DAT 0 to 12 months (n = 84, median DAT 7 months), Q2 was DAT 13 to 28 months (n = 85, median DAT 20 months), Q3 was DAT 29 to 66 months (n = 84, median DAT 41 months), and Q4 was DAT ≥67 months (n = 81, median DAT 119 months). AF recurrence rate was 36.9% for Q1, 44.7% for Q2, 47.6% for Q3, and 56.8% for Q4 (P = 0.082). On multivariable analysis, DAT Q4 was the only factor significantly associated with risk of recurrence (HR: 1.607; 95% CI: 1.005-2.570; P = 0.048). Median AF burden was 0% (Q1-Q3: 0%-0.47%) in Q1 and 0.33% (Q1-Q3: 0%-4.6%) in Q4 (P = 0.002). Quality of life (assessed by the Atrial Fibrillation Effect on Quality-of-Life questionnaire) improved markedly in all quartiles (Q1: Δ28.8 ± 24, Q2: Δ24.4 ± 23.4, Q3: Δ21.7 ± 26.6, Q4: Δ24.6 ± 21.4; P = 0.331). CONCLUSIONS: In a cohort of patients with persistent AF undergoing ablation in a prospective trial with standardized entry criteria and intensive electrocardiogram monitoring, those with shorter DAT had lower rates of AF recurrence. However, differences were modest, and all quartiles demonstrated very low AF burden and improvements in quality of life.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Recidiva , Humanos , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Veias Pulmonares/cirurgia , Resultado do Tratamento , Fatores de Tempo , Tempo para o Tratamento/estatística & dados numéricos
2.
Intern Med J ; 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38958050

RESUMO

BACKGROUND: Current guidelines highlight a paucity of evidence guiding optimal timing for non-ST-elevation myocardial infarction (NSTEMI) in high-risk and non-high-risk cases. AIM: We assessed long-term major adverse cardiovascular events (MACEs) in NSTEMI patients undergoing early (<24 h) versus delayed (>24 h) coronary angiography at 6 years. Secondary end-points included all-cause mortality and cumulative MACE outcomes. METHODS: Baseline characteristics and clinical outcomes were assessed among 355 patients presenting to a tertiary regional hospital between 2017 and 2018. Cox proportional hazard models were generated for MACE and all-cause mortality outcomes, adjusting for the Global Registry of Acute Coronary Events (GRACE) score, patient demographics, biomarkers and comorbidities. RESULTS: Two hundred and seventy patients were included; 147 (54.4%) and 123 (45.6%) underwent early and delayed coronary angiography respectively. Median time to coronary angiography was 13.3 and 45.4 h respectively. At 6 years, 103 patients (38.1%) experienced MACE; 41 in the early group and 62 in the delayed group (hazard ratio (HR) = 2.23; 95% confidence interval (CI) = 1.50-3.31). After multivariable adjustment, the delayed group had higher rates of MACE (HR = 1.79; 95% CI = 1.19-2.70), all-cause mortality (HR = 2.76; 95% CI = 1.36-5.63) and cumulative MACE (incidence rate ratio = 1.54; 95% CI = 1.12-2.11). Subgroup analysis of MACE outcomes in rural and weekend NSTEMI presentations was not significant between early and delayed coronary angiography (HR = 1.49; 95% CI = 0.83-2.62). CONCLUSION: Higher MACE rates in the delayed intervention group suggest further investigation is needed. Randomised control trials would be well suited to assess the role of early invasive intervention across all NSTEMI risk groups.

3.
JACC Clin Electrophysiol ; 10(7 Pt 2): 1620-1630, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38752960

RESUMO

BACKGROUND: Linear and complex electrogram ablation (LCEA) beyond pulmonary vein isolation (PVI) is associated with an increase in left atrial macro-re-entrant tachycardias (LAMTs). Posterior wall isolation (PWI) is increasingly performed to improve AF ablation outcomes. However, the impact of PWI on the incidence of LAMT is unknown. OBJECTIVES: The purpose of this study was to establish the incidence of LAMT following PVI alone vs PVI + PWI vs PVI + PWI + LCEA. METHODS: Consecutive patients undergoing catheter ablation for AF or LAMT post-AF ablation between 2008 and 2022 from 4 electrophysiology centers were reviewed with a minimum follow-up of 12 months. RESULTS: In total, 5,619 (4,419 index, 1,100 redo) AF ablation procedures were performed in 4,783 patients (mean age 60.9 ± 10.6 years, 70.7% men). Over a mean follow-up of 6.4 ± 3.8 years, 246 procedures for LAMT were performed in 214 patients at a mean of 2.6 ± 0.6 years post-AF ablation. Perimitral (52.8% of patients), roof-dependent (27.1%), PV gap-related (17.3%), and anterior circuits (8.9%) were most common, with 16.4% demonstrating multiple circuits. The incidence of LAMT was significantly higher following PVI + PWI (6.2%) vs PVI alone (3.0%; P < 0.0001) and following PVI + PWI + LCEA vs PVI + PWI (12.5%; P = 0.019). Conduction gaps in previous ablation lines were responsible for LAMT in 28.4% post-PVI alone, 35.3% post-PVI + PWI (P = 0.386), and 81.8% post-PVI + PWI + LCEA (P < 0.005). CONCLUSIONS: The incidence of LAMT following PVI + PWI is higher than with PVI alone but significantly lower than with more extensive atrial substrate modification. Given a low frequency of LAMT following PWI, empiric mitral isthmus ablation is not justified and may be proarrhythmic.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Humanos , Ablação por Cateter/métodos , Ablação por Cateter/efeitos adversos , Feminino , Masculino , Flutter Atrial/cirurgia , Flutter Atrial/epidemiologia , Pessoa de Meia-Idade , Fibrilação Atrial/cirurgia , Fibrilação Atrial/epidemiologia , Incidência , Idoso , Veias Pulmonares/cirurgia , Técnicas Eletrofisiológicas Cardíacas , Estudos Retrospectivos , Resultado do Tratamento
4.
Eur Heart J ; 45(29): 2604-2616, 2024 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-38759110

RESUMO

BACKGROUND AND AIMS: Patterns of atrial fibrillation (AF) recurrence post-catheter ablation for persistent AF (PsAF) are not well described. This study aimed to describe the pattern of AF recurrence seen following catheter ablation for PsAF and the implications for healthcare utilization and quality of life (QoL). METHODS: This was a post-hoc analysis of the CAPLA study, an international, multicentre study that randomized patients with symptomatic PsAF to pulmonary vein isolation plus posterior wall isolation or pulmonary vein isolation alone. Patients underwent twice daily single lead ECG, implantable device monitoring or three monthly Holter monitoring. RESULTS: 154 of 333 (46.2%) patients (median age 67.3 years, 28% female) experienced AF recurrence at 12-month follow-up. Recurrence was paroxysmal in 97 (63%) patients and persistent in 57 (37%). Recurrence type did not differ between randomization groups (P = .508). Median AF burden was 27.4% in PsAF recurrence and .9% in paroxysmal AF (PAF) recurrence (P < .001). Patients with PsAF recurrence had lower baseline left ventricular ejection fraction (PsAF 50% vs. PAF 60%, P < .001) and larger left atrial volume (PsAF 54.2 ± 19.3 mL/m² vs. PAF 44.8 ± 11.6 mL/m², P = .008). Healthcare utilization was significantly higher in PsAF (45 patients [78.9%]) vs. PAF recurrence (45 patients [46.4%], P < .001) and lowest in those without recurrence (17 patients [9.5%], P < .001). Patients without AF recurrence had greater improvements in QoL as assessed by the Atrial Fibrillation Effect on Quality-of-Life (AFEQT) questionnaire (Δ33.3 ± 25.2 points) compared to those with PAF (Δ24.0 ± 25.0 points, P = .012) or PsAF (Δ13.4 ± 22.9 points, P < .001) recurrence. CONCLUSIONS: AF recurrence is more often paroxysmal after catheter ablation for PsAF irrespective of ablation strategy. Recurrent PsAF was associated with higher AF burden, increased healthcare utilization and antiarrhythmic drug use. The type of AF recurrence and AF burden may be considered important endpoints in clinical trials investigating ablation of PsAF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Qualidade de Vida , Recidiva , Humanos , Fibrilação Atrial/cirurgia , Feminino , Masculino , Ablação por Cateter/métodos , Idoso , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Eletrocardiografia Ambulatorial , Aceitação pelo Paciente de Cuidados de Saúde/estatística & dados numéricos , Resultado do Tratamento
6.
Heart Rhythm ; 21(6): 762-770, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38336190

RESUMO

BACKGROUND: Sex-specific outcomes after catheter ablation (CA) for atrial fibrillation (AF) have reported conflicting findings. OBJECTIVE: We examined the impact of female sex on outcomes in patients with persistent AF (PsAF) from the Catheter Ablation for Persistent Atrial Fibrillation: A Multicentre Randomized Trial of Pulmonary Vein Isolation vs PVI with Posterior Left Atrial Wall Isolation (CAPLA) randomized trial. METHODS: A total of 338 patients with PsAF were randomized to pulmonary vein isolation (PVI) or PVI with posterior wall isolation (PWI). The primary outcome was arrhythmia recurrence at 12 months. Clinical and electroanatomical characteristics, arrhythmia recurrence, and quality of life were compared between women and men. RESULTS: Seventy-nine women (23.4%; PVI 37; PVI + PWI 42) and 259 men (76.6%; PVI 131; PVI + PWI 128) underwent AF ablation. Women were older {median age 70.4 (interquartile range [IQR] 64.8-74.6) years vs 64.0 (IQR 56.7-69.7) years; P < .001} and had more advanced left atrial electroanatomical remodeling. At 12 months, arrhythmia-free survival was lower in women (44.3% vs 56.8% in men; hazard ratio 1.44; 95% confidence interval 1.02-2.04; log-rank, P = .036). PWI did not improve arrhythmia-free survival at 12 months (hazard ratio 1.02; 95% confidence interval 0.74-1.40; log-rank, P = .711). The median AF burden was 0% in both groups (women: IQR 0.0%-2.2% vs men: IQR 0.0%-2.8%; P = .804). Health care utilization was comparable between women (36.7%) and men (30.1%) (P = .241); however, women were more likely to undergo a repeat procedure (17.7% vs 6.9%; P = .007). Women reported more severe baseline anxiety (average Hospital Anxiety and Depression Scale [HADS] anxiety score 7.5 ± 4.9 vs 6.3 ± 4.3 in men; P = .035) and AF-related symptoms (baseline Atrial Fibrillation Effect on Quality-of-Life Questionnaire [AFEQT] score 46.7 ± 20.7 vs 55.9 ± 23.0 in men; P = .002), with comparable improvements in psychological symptoms (change in HADS anxiety score -3.8 ± 4.6 vs -3.0 ± 4.5; P = .152 (change in HADS depression score -2.9 ± 5.0 vs -2.6 ± 4.0; P = .542) and greater improvement in AFEQT score compared with men at 12 months (change in AFEQT score +45.9 ± 23.1 vs +39.2 ± 24.8; P = .048). CONCLUSION: Women undergoing CA for PsAF report more significant symptoms and poorer quality of life at baseline than men. Despite higher arrhythmia recurrence and repeat procedures in women, the AF burden was comparably low, resulting in significant improvements in quality of life and psychological well-being after CA in both sexes.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Qualidade de Vida , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Fatores Sexuais , Veias Pulmonares/cirurgia , Resultado do Tratamento , Recidiva , Átrios do Coração/fisiopatologia , Seguimentos
7.
JACC Clin Electrophysiol ; 10(3): 527-536, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38180432

RESUMO

BACKGROUND: Non-pulmonary vein (PV) triggers are increasingly targeted during atrial fibrillation (AF) ablation. P-wave morphology (PWM) can be useful because point mapping of AF triggers is challenging. The impact of prior ablation on PWM is yet to be determined. OBJECTIVES: This study sought to report PWM before and after left atrial (LA) ablation and construct a P-wave algorithm of common non-PV trigger locations. METHODS: This multicenter, prospective, observational study analyzed the paced PWM of 30 patients with persistent AF undergoing pulmonary vein isolation (PVI) and posterior wall isolation (PWI). Pace mapping was performed at the SVC, crista terminalis, inferior tricuspid annulus, coronary sinus ostium, left septum, left atrial appendage, Ligament of Marshall, and inferoposterior LA. The PWM was reported before PVI, then blinded comparisons were made post-PVI and post-PVI + PWI. A P-wave algorithm was constructed. RESULTS: A total of 8,352 paced P waves were prospectively recorded. No significant changes in the PWM were seen post-PVI alone in 2,775 of 2,784 (99.7%) and post-PWI in 2,715 of 2,784 (97.5%). Changes in PWM were predominantly at the IPLA (53 P waves) with a positive P-wave in leads V2 to V6 before biphasic post-PWI, LA appendage (9 P waves), coronary sinus ostium (6 P waves), and ligament of Marshall (3 P waves). A PWM algorithm was created before PVI and accurately predicted the location in 93% post-PVI + PWI. CONCLUSIONS: Minimal change was observed in PWM post-PV and PWI aside from the IPLA location. A P-wave algorithm created before and applied after PVI + PWI provided an accuracy of 93%. PWM provides a reliable tool to guide the localization of common non-PV trigger sites even after PV and PWI.


Assuntos
Fibrilação Atrial , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Fibrilação Atrial/cirurgia , Átrios do Coração
9.
JACC Clin Electrophysiol ; 10(2): 206-218, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38099880

RESUMO

BACKGROUND: Accurate annotation of electrogram local activation time (LAT) is critical to the functional assessment of ventricular tachycardia (VT) substrate. Contemporary methods of annotation include: 1) earliest bipolar electrogram (LATearliest); 2) peak bipolar electrogram (LATpeak); 3) latest bipolar electrogram (LATlatest); and 4) steepest unipolar -dV/dt (LAT-dV/dt). However, no direct comparison of these methods has been performed in a large dataset, and it is unclear which provides the optimal functional analysis of the VT substrate. OBJECTIVES: This study sought to investigate the optimal method of LAT annotation during VT substrate mapping. METHODS: Patients with high-density VT substrate maps and a defined critical site for VT re-entry were included. All electrograms were annotated using 5 different methods: LATearliest, LATpeak, LATlatest, LAT-dV/dt, and the novel steepest unipolar -dV/dt using a dynamic window of interest (LATDWOI). Electrograms were also tagged as either late potentials and/or fractionated signals. Maps, utilizing each annotation method, were then compared in their ability to identify critical sites using deceleration zones. RESULTS: Fifty cases were identified with 1,.813 ± 811 points per map. Using LATlatest, a deceleration zone was present at the critical site in 100% of cases. There was no significant difference with LATearliest (100%) or LATpeak (100%). However, this number decreased to 54% using LAT-dV/dt and 76% for LATDWOI. Using LAT-dV/dt, only 33% of late potentials were correctly annotated, with the larger far field signals often annotated preferentially. CONCLUSIONS: Annotation with LAT-dV/dt and LATDWOI are suboptimal in VT substrate mapping. We propose that LATlatest should be the gold standard annotation method, as this allows identification of critical sites and is most suited to automation.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Ablação por Cateter/métodos , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas , Eletrocardiografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA