Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Artery Res ; 30(Suppl 1): 1-7, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39086596

RESUMO

Objectives: In general, a terminology shared and agreed by different stakeholders is important to facilitate communication and cooperation. This holds true in the field of vascular ageing for the benefit of global cardiovascular health. The need to promote a common language and understanding across this area was recognised by VascAgeNet, a collaborative network with relevant and diverse expertise in the vascular ageing field, supported by the European Cooperation in Science and Technology. To contribute to the spread of unified terms in the vascular ageing field, a glossary was created by VascAgeNet and this paper describes the systematic process used for its development. Methods: An initial list of terms and preliminary definitions were collated from the network. A dedicated team was created to design the glossary development process, to facilitate its implementation and to maximise outreach and dissemination. The key steps of the process were to determine: (1) the target audience; (2) a list of priority terms; (3) a template structure for definitions; (4) methods for collecting feedback and (5) the dissemination plan. Results: An implementation strategy was provided for each key step and shared within the network; main decisions were agreed by all members of the glossary team. Small groups of definitions were released on a regular basis within a pilot phase including 19 terms (status: 05.09.2023) that were published openly at https://vascagenet.eu/official-glossary. Conclusions: The strategy for creating the first Vascular Ageing Glossary has been successfully designed and developed within VascAgeNet. A pilot phase covering the first publicly available terms was completed. The glossary is a living document, available to the scientific community, which aims to unify the vascular ageing language. Supplementary Information: The online version contains supplementary material available at 10.1007/s44200-023-00041-5.

2.
Sci Rep ; 14(1): 12717, 2024 06 03.
Artigo em Inglês | MEDLINE | ID: mdl-38830910

RESUMO

Chiari type 1 malformation is a neurological disorder characterized by an obstruction of the cerebrospinal fluid (CSF) circulation between the brain (intracranial) and spinal cord (spinal) compartments. Actions such as coughing might evoke spinal cord complications in patients with Chiari type 1 malformation, but the underlying mechanisms are not well understood. More insight into the impact of the obstruction on local and overall CSF dynamics can help reveal these mechanisms. Therefore, our previously developed computational fluid dynamics framework was used to establish a subject-specific model of the intracranial and upper spinal CSF space of a healthy control. In this model, we emulated a single cough and introduced porous zones to model a posterior (OBS-1), mild (OBS-2), and severe posterior-anterior (OBS-3) obstruction. OBS-1 and OBS-2 induced minor changes to the overall CSF pressures, while OBS-3 caused significantly larger changes with a decoupling between the intracranial and spinal compartment. Coughing led to a peak in overall CSF pressure. During this peak, pressure differences between the lateral ventricles and the spinal compartment were locally amplified for all degrees of obstruction. These results emphasize the effects of coughing and indicate that severe levels of obstruction lead to distinct changes in intracranial pressure.


Assuntos
Malformação de Arnold-Chiari , Líquido Cefalorraquidiano , Tosse , Hidrodinâmica , Malformação de Arnold-Chiari/líquido cefalorraquidiano , Malformação de Arnold-Chiari/fisiopatologia , Malformação de Arnold-Chiari/complicações , Tosse/fisiopatologia , Humanos , Simulação por Computador , Pressão do Líquido Cefalorraquidiano/fisiologia , Medula Espinal/fisiopatologia , Feminino
3.
Hypertension ; 81(9): 1986-1995, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38934112

RESUMO

BACKGROUND: Carotid-femoral pulse wave velocity (cfPWV) is the gold standard for noninvasive arterial stiffness assessment, an independent predictor of cardiovascular disease, and a potential parameter to guide therapy. However, cfPWV is not routinely measured in clinical practice due to the unavailability of a low-cost, operator-friendly, and independent device. The current study validated a novel laser Doppler vibrometry (LDV)-based measurement of cfPWV against the reference technique. METHODS: In 100 (50 men) hypertensive patients, cfPWV was measured using applanation tonometry (Sphygmocor) and the novel LDV device. This device has 2 handpieces with 6 laser beams each that simultaneously measure vibrations from the skin surface at carotid and femoral sites. Pulse wave velocity is calculated using ECG for the identification of cardiac cycles. An ECG-independent method was also devised. Cardiovascular risk score was calculated for patients between 40 and 75 years old using the WHO risk scoring chart. RESULTS: LDV-based cfPWV correlated significantly with tonometry (r=0.86, P<0.0001 ECG-dependent [cfPWVLDV_ECG] and r=0.80, P<0.001 ECG-independent [cfPWVLDV_w/oECG] methods). Bland-Altman analysis showed nonsignificant bias (0.65 m/s) and acceptable SD (1.27 m/s) between methods. Intraobserver coefficient of variance for LDV was 4.7% (95% CI, 3.0%-5.5%), and interobserver coefficient of variance was 5.87%. CfPWV correlated significantly with CVD risk (r=0.64, P<0.001; r=0.41, P=0.003; and r=0.37, P=0.006 for tonometry, LDV-with, and LDV-without ECG, respectively). CONCLUSIONS: The study demonstrates clinical validity of the LDV device. The LDV provides a simple, noninvasive, operator-independent method to measure cfPWV for assessing arterial stiffness, comparable to the standard existing techniques. REGISTRATION: URL: https://clinicaltrials.gov/study/NCT03446430; Unique identifier: NCT03446430.


Assuntos
Velocidade da Onda de Pulso Carótido-Femoral , Rigidez Vascular , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doenças Cardiovasculares/fisiopatologia , Doenças Cardiovasculares/diagnóstico , Artérias Carótidas/fisiopatologia , Velocidade da Onda de Pulso Carótido-Femoral/métodos , Artéria Femoral/fisiopatologia , Hipertensão/fisiopatologia , Hipertensão/diagnóstico , Manometria/métodos , Manometria/instrumentação , Análise de Onda de Pulso/métodos , Análise de Onda de Pulso/instrumentação , Reprodutibilidade dos Testes , Rigidez Vascular/fisiologia , Vibração
4.
Comput Biol Med ; 176: 108604, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38761502

RESUMO

OBJECTIVE: In young patients, aortic valve disease is often treated by placement of a pulmonary autograft (PA) which adapts to its new environment through growth and remodeling. To better understand the hemodynamic forces acting on the highly distensible PA in the acute phase after surgery, we developed a fluid-structure interaction (FSI) framework and comprehensively compared hemodynamics and wall shear-stress (WSS) metrics with a computational fluid dynamic (CFD) simulation. METHODS: The FSI framework couples a prestressed non-linear hyperelastic arterial tissue model with a fluid model using the in-house coupling code CoCoNuT. Geometry, material parameters and boundary conditions are based on in-vivo measurements. Hemodynamics, time-averaged WSS (TAWSS), oscillatory shear index (OSI) and topological shear variation index (TSVI) are evaluated qualitatively and quantitatively for 3 different sheeps. RESULTS: Despite systolic-to-diastolic volumetric changes of the PA in the order of 20 %, the point-by-point correlation of TAWSS and OSI obtained through CFD and FSI remains high (r > 0.9, p < 0.01) for TAWSS and (r > 0.8, p < 0.01) for OSI). Instantaneous WSS divergence patterns qualitatively preserve similarities, but large deformations of the PA leads to a decrease of the correlation between FSI and CFD resolved TSVI (r < 0.7, p < 0.01). Moderate co-localization between FSI and CFD is observed for low thresholds of TAWSS and high thresholds of OSI and TSVI. CONCLUSION: FSI might be warranted if we were to use the TSVI as a mechano-biological driver for growth and remodeling of PA due to varying intra-vascular flow structures and near wall hemodynamics because of the large expansion of the PA.


Assuntos
Hemodinâmica , Modelos Cardiovasculares , Artéria Pulmonar , Hemodinâmica/fisiologia , Artéria Pulmonar/fisiologia , Artéria Pulmonar/fisiopatologia , Hidrodinâmica , Animais , Humanos , Simulação por Computador , Valva Pulmonar/cirurgia , Valva Pulmonar/fisiologia , Autoenxertos , Estresse Mecânico
5.
J Sport Health Sci ; 13(6): 863-871, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38582138

RESUMO

BACKGROUND: Tendinopathy alters the compositional properties of the Achilles tendon by increasing fluid and glycosaminoglycan content. It has been speculated that these changes may affect intratendinous pressure, but the extent of this relationship remains unclear. Therefore, we aimed to investigate the impact of elevated fluid and glycosaminoglycan content on Achilles tendon intratendinous pressure and to determine whether hyaluronidase (HYAL) therapy can intervene in this potential relationship. METHODS: Twenty paired fresh-frozen cadaveric Achilles tendons were mounted in a tensile-testing machine and loaded up to 5% strain. Intratendinous resting (at 0% strain) and dynamic pressure (at 5% strain) were assessed using the microcapillary infusion technique. First, intratendinous pressure was measured under native conditions before and after infusion of 2 mL physiological saline. Next, 80 mg of glycosaminoglycans were administered bilaterally to the paired tendons. The right tendons were additionally treated with 1500 units of HYAL. Finally, both groups were retested, and the glycosaminoglycan content was analyzed. RESULTS: It was found that both elevated fluid and glycosaminoglycan content resulted in higher intratendinous resting and dynamic pressures (p < 0.001). HYAL treatment induced a 2.3-fold reduction in glycosaminoglycan content (p = 0.002) and restored intratendinous pressures. CONCLUSION: The results of this study demonstrated that elevated fluid and glycosaminoglycan content in Achilles tendinopathy contribute to increased intratendinous resting and dynamic pressures, which can be explained by the associated increased volume and reduced permeability of the tendon matrix, respectively. HYAL degrades glycosaminoglycans sufficiently to lower intratendinous pressures and may, therefore, serve as a promising treatment.


Assuntos
Tendão do Calcâneo , Glicosaminoglicanos , Hialuronoglucosaminidase , Pressão , Tendinopatia , Tendão do Calcâneo/metabolismo , Humanos , Tendinopatia/metabolismo , Glicosaminoglicanos/metabolismo , Glicosaminoglicanos/análise , Hialuronoglucosaminidase/metabolismo , Masculino , Pessoa de Meia-Idade , Feminino , Cadáver , Idoso , Adulto , Resistência à Tração
6.
JACC Cardiovasc Imaging ; 17(3): 314-329, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38448131

RESUMO

The advent of high-frame rate imaging in ultrasound allowed the development of shear wave elastography as a noninvasive alternative for myocardial stiffness assessment. It measures mechanical waves propagating along the cardiac wall with speeds that are related to stiffness. The use of cardiac shear wave elastography in clinical studies is increasing, but a proper understanding of the different factors that affect wave propagation is required to correctly interpret results because of the heart's thin-walled geometry and intricate material properties. The aims of this review are to give an overview of the general concepts in cardiac shear wave elastography and to discuss in depth the effects of age, hemodynamic loading, cardiac morphology, fiber architecture, contractility, viscoelasticity, and system-dependent factors on the measurements, with a focus on clinical application. It also describes how these factors should be considered during acquisition, analysis, and reporting to ensure an accurate, robust, and reproducible measurement of the shear wave.


Assuntos
Cardiologia , Técnicas de Imagem por Elasticidade , Humanos , Valor Preditivo dos Testes , Ultrassonografia , Miocárdio
7.
Sci Rep ; 14(1): 5913, 2024 03 11.
Artigo em Inglês | MEDLINE | ID: mdl-38467721

RESUMO

Central aortic diastolic pressure decay time constant ( τ ) is according to the two-element Windkessel model equal to the product of total peripheral resistance ( R ) times total arterial compliance ( C ). As such, it is related to arterial stiffness, which has considerable pathophysiological relevance in the assessment of vascular health. This study aimed to investigate the relationship of the constant τ with the product T MBP cPP , given by heart period ( T ) times the ratio of mean blood pressure (MBP) to central pulse pressure ( cPP ). The relationship was derived by performing linear fitting on an in silico population of n1 = 3818 virtual subjects, and was subsequently evaluated on in vivo data (n2 = 2263) from the large Asklepios study. The resulted expression was found to be τ = k ' T MBP cPP , with k ' = 0.7 (R2 = 0.9). The evaluation of the equation on the in vivo human data reported high agreement between the estimated and reference τ values, with a correlation coefficient equal to 0.94 and a normalized RMSE equal to 5.5%. Moreover, the analysis provided evidence that the coefficient k ' is age- and gender-independent. The proposed formula provides novel theoretical insights in the relationship between τ and central blood pressure features. In addition, it may allow for the evaluation of τ without the need for acquiring the entire central blood pressure wave, especially when an approximation of the cPP is feasible. This study adds to the current literature by contributing to the accessibility of an additional biomarker, such as the central diastolic pressure decay time constant, for the improved assessment of vascular ageing.


Assuntos
Artérias , Rigidez Vascular , Humanos , Pressão Sanguínea/fisiologia , Artérias/fisiologia , Aorta/fisiologia , Pressão Arterial , Resistência Vascular
8.
Phys Med Biol ; 69(7)2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38412537

RESUMO

Objective. An elevated interstitial fluid pressure (IFP) can lead to strain-induced stiffening of poroelastic biological tissues. As shear wave elastography (SWE) measures functional tissue stiffness based on the propagation speed of acoustically induced shear waves, the shear wave velocity (SWV) can be used as an indirect measurement of the IFP. The underlying biomechanical principle for this stiffening behavior with pressurization is however not well understood, and we therefore studied how IFP affects SWV through SWE experiments and numerical modeling.Approach. For model set-up and verification, SWE experiments were performed while dynamically modulating IFP in a chicken breast. To identify the confounding factors of the SWV-IFP relationship, we manipulated the material model (linear poroelastic versus porohyperelastic), deformation assumptions (geometric linearity versus nonlinearity), and boundary conditions (constrained versus unconstrained) in a finite element model mimicking the SWE experiments.Main results. The experiments demonstrated a statistically significant positive correlation between the SWV and IFP. The model was able to reproduce a similar SWV-IFP relationship by considering an unconstrained porohyperelastic tissue. Material nonlinearity was identified as the primary factor contributing to this relationship, whereas geometric nonlinearity played a smaller role. The experiments also highlighted the importance of the dynamic nature of the pressurization procedure, as indicated by a different observed SWV-IFP for pressure buildup and relaxation, but its clinical relevance needs to be further investigated.Significance. The developed model provides an adaptable framework for SWE of poroelastic tissues and paves the way towards non-invasive measurements of IFP.


Assuntos
Técnicas de Imagem por Elasticidade , Técnicas de Imagem por Elasticidade/métodos , Líquido Extracelular/diagnóstico por imagem
9.
J Mech Behav Biomed Mater ; 151: 106370, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38224645

RESUMO

Personalized treatment informed by computational models has the potential to markedly improve the outcome for patients with a type B aortic dissection. However, existing computational models of dissected walls significantly simplify the characteristic false lumen, tears and/or material behavior. Moreover, the patient-specific wall thickness and stiffness cannot be accurately captured non-invasively in clinical practice, which inevitably leads to assumptions in these wall models. It is important to evaluate the impact of the corresponding uncertainty on the predicted wall deformations and stress, which are both key outcome indicators for treatment optimization. Therefore, a physiology-inspired finite element framework was proposed to model the wall deformation and stress of a type B aortic dissection at diastolic and systolic pressure. Based on this framework, 300 finite element analyses, sampled with a Latin hypercube, were performed to assess the global uncertainty, introduced by 4 uncertain wall thickness and stiffness input parameters, on 4 displacement and stress output parameters. The specific impact of each input parameter was estimated using Gaussian process regression, as surrogate model of the finite element framework, and a δ moment-independent analysis. The global uncertainty analysis indicated minor differences between the uncertainty at diastolic and systolic pressure. For all output parameters, the 4th quartile contained the major fraction of the uncertainty. The parameter-specific uncertainty analysis elucidated that the material stiffness and relative thickness of the dissected membrane were the respective main determinants of the wall deformation and stress. The uncertainty analysis provides insight into the effect of uncertain wall thickness and stiffness parameters on the predicted deformation and stress. Moreover, it emphasizes the need for probabilistic rather than deterministic predictions for clinical decision making in aortic dissections.


Assuntos
Aorta , Dissecção Aórtica , Humanos , Incerteza , Pressão Sanguínea , Modelos Cardiovasculares , Estresse Mecânico
10.
Small Methods ; : e2301499, 2024 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-38200600

RESUMO

Vascular corrosion casting is a method used to visualize the three dimensional (3D) anatomy and branching pattern of blood vessels. A polymer resin is injected in the vascular system and, after curing, the surrounding tissue is removed. The latter often deforms or even fractures the fragile cast. Here, a method is proposed that does not require corrosion, and is based on in situ micro computed tomography (micro-CT) scans. To overcome the lack of CT contrast between the polymer cast and the animals' surrounding soft tissue, hafnium oxide nanocrystals (HfO2 NCs) are introduced as CT contrast agents into the resin. The NCs dramatically improve the overall CT contrast of the cast and allow for straightforward segmentation in the CT scans. Careful design of the NC surface chemistry ensures the colloidal stability of the NCs in the casting resin. Using only 5 m% of HfO2 NCs, high-quality cardiovascular casts of both zebrafish and mice can be automatically segmented using CT imaging software. This allows to differentiate even µ $\umu$ m-scale details without having to alter the current resin injection methods. This new method of virtual dissection by visualizing casts in situ using contrast-enhanced CT imaging greatly expands the application potential of the technique.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA