Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Synchrotron Radiat ; 30(Pt 2): 301-307, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36891843

RESUMO

An insertion device capable of switching the operation mode between helical and figure-8 undulators, and thus referred to as a helical-8 undulator, has been developed. It has the advantage that the on-axis heat load can be kept low regardless of the polarization state, even when a high K value is required to lower the fundamental photon energy. This is in contrast to conventional undulators in which the on-axis heat load tends to be significantly high to generate linearly polarized radiation with a high K value, and optical elements can be seriously damaged. The principle of operation, specification and light source performance of the developed helical-8 undulator are presented together with further options to enhance its capability.

2.
Rev Sci Instrum ; 88(7): 073302, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28764549

RESUMO

A lightweight-compact variable-gap undulator (LCVGU) having the force-cancellation system based on the multipole monolithic magnets (MMMs) has been developed. The LCVGU is free from the heavy mechanical frames, which is a fundamental element specific to conventional variable-gap undulators (VGUs) because of a strong attractive force, and thus the cost and time for construction and installation are expected to be significantly reduced; the MMMs counteract the strong attractive force in a cost-effective manner. Results of mechanical tests and magnetic-field measurements of two prototype LCVGUs equipped with the proposed force cancellation system have revealed the comparable performance with the conventional VGUs.

3.
Sci Rep ; 6: 37937, 2016 11 29.
Artigo em Inglês | MEDLINE | ID: mdl-27897218

RESUMO

We report an unexpectedly large flux loss observed in permanent magnets in one of the undulators operated in SACLA, the x-ray free electron laser facility in Japan. Characterizations of individual magnets extracted from the relevant undulator have revealed that the flux loss was caused by a homogeneous magnetization reversal extending over a wide area, but not by demagnetization of individual magnets damaged by radiation. We show that the estimated flux-loss rate is much higher than what is reported in previous papers, and its distribution is much more localized to the upstream side. Results of numerical and experimental studies carried out to validate the magnetization reversal and quantify the flux loss are presented, together with possible countermeasures against rapid degradation of the undulator performance.

4.
J Synchrotron Radiat ; 21(Pt 2): 352-65, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24562556

RESUMO

A new soft X-ray beamline, BL07LSU, has been constructed at SPring-8 to perform advanced soft X-ray spectroscopy for materials science. The beamline is designed to achieve high energy resolution (E/ΔE> 10000) and high photon flux [>10(12) photons s(-1) (0.01% bandwidth)(-1)] in the photon energy range 250-2000 eV with controllable polarization. To realise this state-of-the-art performance, a novel segmented cross undulator was developed and adopted as a light source. The details of the undulator light source and beamline monochromator design are described. The achieved performance of the beamline, such as the photon flux, energy resolution and the state of polarization, is reported.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA