Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Radiol Case Rep ; 19(3): 1211-1214, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38259702

RESUMO

A 60-year-old woman with a history of neurofibromatosis type 1, who was admitted with pulmonary hypertension, developed buttock pain and anemia, and contrast-enhanced computed tomography showed a large subcutaneous hematoma with minimal active extravasation. Angiography of the bilateral internal iliac arteries revealed diffuse, irregular blood vessels without extravasation. As the exact bleeding site could not be identified, the patient was managed conservatively. However, the patient's symptoms and anemia worsened the following day. Repeat angiography revealed two pseudoaneurysms in the right inferior gluteal artery, which were embolized using n-butyl-2-cyanoacrylate. Nonetheless, the patient's anemia further worsened the following day. Repeat contrast-enhanced CT revealed another site of extravasation in the enlarging hematoma, but no extravasation was observed on the subsequent angiography. Owing to the worsening anemia and enlarging hematoma, proximal embolization of the irregular bilateral inferior gluteal arteries was performed using gelatin sponge particles. The patient's anemia and symptoms improved. Vasculopathy associated with neurofibromatosis type 1 is rare, with an incidence of approximately 3%. In patients with neurofibromatosis type 1, the blood vessels become fragile because of tunica media thinning and elastic-lamina rupture. Histopathologically, neurofibromatosis type 1-associated vasculopathy is characterized by a mixture of normal and abnormal vessels. Abnormally fragile blood vessels may repeatedly rupture followed by physiological hemostasis, which may explain the diagnostic and therapeutic challenges during angiography in this case. In patients with neurofibromatosis type 1 with acute bleeding, irregular vessels without active extravasation on angiography may be indicated for embolization.

2.
Health Phys ; 125(6): 427-433, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37707434

RESUMO

ABSTRACT: Radiation exposure of a practitioner's fingers is a problem in interventional radiology, and radiation protection gloves (protective gloves) can help reduce such exposure. Several types of protective gloves are commercially available from various manufacturers. In the present study, we compared the protective effects and usability of four types of protective gloves. To investigate the radiation protection effect, we placed normal surgical gloves and the four types of protective gloves on phantom hands with thermoluminescent dosimeters (TLD) attached to the fingertips and the dorsum and palms of the hands. Next, they were irradiated with x rays, and the radiation dose was measured and compared using the TLDs. In terms of usability, 42 medical staff members completed a questionnaire that included seven items, such as finger movability, tactile sensation, grip, and overall satisfaction, which were scored on a 5-point scale. Consequently, the protective effects differed between the gloves, and radiation exposure was lower by 30% to 60% with these gloves compared with surgical gloves. In terms of usability, a difference of 2 to 4 points was noted between the gloves for each questionnaire item. These results suggest that radiation protective gloves can protect the surgeon's fingers from radiation exposure without reducing work efficiency by selecting gloves according to the surgical procedure.

3.
Jpn J Radiol ; 36(3): 209-214, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29224115

RESUMO

PURPOSE: To evaluate the usefulness of computed tomographic (CT) features for identifying acute torsion of uterine subserosal leiomyoma (USL). SUBJECTS AND METHODS: We analyzed contrast-enhanced CT examinations of 7 USLs with torsion and 44 USLs without torsion. Two radiologists evaluated the CT features, which consisted of poor contrast enhancement inside the USL, thin rim enhancement around the USL, calcification within the USL, a beak sign between the uterus and USL, fan-shaped poor contrast enhancement in the uterus area adjacent to the USL (dark fan sign), and ascites. We analyzed the frequencies of these CT features in the USLs with versus without torsion using Fisher's exact test. RESULTS: The respective frequencies of CT features in USLs with and without torsion were as follows: poor contrast enhancement, 86 and 5% (P = 0.001); thin rim enhancement, 71 and 9% (P = 0.001); calcification, 29 and 18% (P = 0.61); beak sign, 57 and 86% (P = 0.10); dark fan sign, 57 and 0% (P = 0.001); and ascites, 100 and 20% (P = 0.01). CONCLUSIONS: The CT features of poor contrast enhancement, thin rim enhancement, and dark fan sign are valuable for identifying acute torsion of USL.


Assuntos
Leiomioma/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Neoplasias Uterinas/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos
4.
Magn Reson Med Sci ; 15(2): 212-9, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26607809

RESUMO

PURPOSE: To evaluate morphological and signal intensity (SI) changes of placental insufficiency on magnetic resonance imaging (MRI) and to assess morphological changes and decreased flow voids (FVs) on T2-weighted rapid acquisition with relaxation enhancement (RARE) images for diagnosing placental insufficiency. METHODS: Fifty singleton fetuses underwent MRI using a 1.5-T MR scanner. Placental thickness, area, volume, SI, amniotic fluid SI, and size of FVs between the uterus and the placenta were measured on MR images. Two radiologists reviewed T2-weighted RARE images for globular appearance of the placenta and FVs between the uterus and the placenta. Data were analyzed using t-tests, McNemar's tests, and areas under the receiver operating characteristic curve (AUCs) at 5% level of significance. RESULTS: Twenty-five of the 50 pregnancies were categorized as having an insufficient placenta. Significant differences were observed between insufficient and normal placentas in mean placental thickness, area, volume, placenta to amniotic fluid SI ratio, and size of FVs (49.0 mm vs. 36.9 mm, 1.62 × 10(4) mm(2) vs. 2.67 × 10(4) mm(2), 5.13 × 10(5) mm(3) vs. 6.56 × 10(5) mm(3), 0.549 vs. 0.685, and 3.4 mm vs. 4.3 mm, respectively). The sensitivity and accuracy using globular appearance plus decreased FVs were greater than those using decreased FVs (P < 0.01). There was no significant difference among AUCs using globular appearance and decreased FVs, and globular appearance plus decreased FVs. CONCLUSIONS: Placental insufficiency was associated with placental thickness, area, volume, placenta to amniotic fluid SI ratio, and size of FVs. Evaluating FVs on T2-weighted RARE images can be useful for detecting placental insufficiency, particularly in placentas without globular appearance on MR images.


Assuntos
Feto/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Insuficiência Placentária/diagnóstico por imagem , Feminino , Humanos , Gravidez
5.
Clin Imaging ; 36(5): 526-31, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22920357

RESUMO

PURPOSE: To investigate the diagnostic accuracy of 3.0-T diffusion-weighted imaging (DWI) for detection of prostate cancer by using different b-values. METHODS: Seventy-three patients underwent magnetic resonance imaging (MRI) at 3.0 T. Three MRI sets were reviewed by two radiologists: MRI and DWI (b = 500 s/mm(2)) (protocol A), MRI and DWI (b = 1000 s/mm(2)) (protocol B), and MRI and DWI (b = 2000s/mm(2)) (protocol C). Areas under the receiver operating characteristic curve (AUCs) were calculated. RESULTS: The mean of the AUCs in protocol C was larger than those in protocol A and in protocol B (P<.05). CONCLUSION: DWI (b = 2000s/mm(2)) at 3.0 T can improve the diagnostic accuracy for detection of prostate cancer.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico , Idoso , Biópsia , Diagnóstico Diferencial , Humanos , Masculino , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/patologia , Curva ROC , Estudos Retrospectivos
6.
J Magn Reson Imaging ; 32(5): 1061-7, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21031509

RESUMO

PURPOSE: To evaluate motion artifacts, tissue contrasts, and lesion detectability in the neck with the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) (BLADE) technique. MATERIALS AND METHODS: A total of 46 patients referred for MRI of the neck were included in a comparison of T2-weighted BLADE (T2W-BLADE) sequence and T2W fast spin-echo (T2W-FSE) sequence. All examinations were performed at 3T using the same parameters. Two observers evaluated unlabelled images for motion artifacts, the preferred image quality, and lesion detectability. Region of interest (ROI)-based quantitative measurements were performed to assess tissue contrasts. The frequency of occurrence of the different assessed artifacts and the lesion detectability was tested using McNemar's test. Tissue contrasts were compared using the Wilcoxon paired test. Reader agreement was assessed using kappa test. RESULTS: T2W-BLADE showed less ghosting and pulsation artifacts than T2W-FSE (P < 0.01). T2W-BLADE images were rated as better than or equal to T2W-FSE images in majority cases (93.5%; kappa = 0.64). There was not significant difference in tissue contrasts between T2W-BLADE and T2W-FSE. A total of 32 lesions were present in 32 patients and equally well seen on T2W-BLADE and T2W-FSE. CONCLUSION: T2W-BLADE can reduce motion artifacts and provide tissue contrasts and lesion detectability equivalent to T2W-FSE.


Assuntos
Artefatos , Aumento da Imagem , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/métodos , Pescoço/patologia , Cistos/diagnóstico , Feminino , Neoplasias de Cabeça e Pescoço/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade
7.
Jpn J Radiol ; 28(7): 542-6, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20799021

RESUMO

We successfully created a percutaneous transhepatic portacaval shunt under ultrasonography (US) guidance in a 46-year-old man with refractory ascites. The shunt was created to salvage an attempt to create a transjugular intrahepatic portosystemic shunt (TIPS) that failed because of the elevated level of portal vein bifurcation due to alcoholic liver cirrhosis. Under US guidance, we simultaneously punctured the right branch of the portal vein and the inferior vena cava (IVC) using a two-step biliary drainage set. An Amplatz gooseneck snare was introduced transjugularly to retrieve the percutaneously inserted guidewire. The intrahepatic tract between the portal vein and the IVC was dilated using a balloon catheter, and a stent was placed in the tract. The patient showed complete resolution of ascites at discharge. We assume that our method is an alternative method for TIPS creation in patients with inadequate anatomical relations between the portal vein branches and the hepatic veins. This approach is thought to be feasible for patients with occluded or small hepatic veins.


Assuntos
Ascite/terapia , Derivação Portocava Cirúrgica/métodos , Ultrassonografia de Intervenção , Ascite/diagnóstico por imagem , Ascite/etiologia , Humanos , Cirrose Hepática Alcoólica/complicações , Masculino , Pessoa de Meia-Idade , Terapia de Salvação , Tomografia Computadorizada por Raios X
9.
Radiology ; 227(1): 124-7, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12601191

RESUMO

PURPOSE: To evaluate the effect of Joint Photographic Experts Group (JPEG) compression ratios of 10:1 and 20:1 on detection of acute cerebral infarction at computed tomography (CT). MATERIALS AND METHODS: CT images obtained in 25 patients with acute cerebral infarction and 25 patients with no lesions were compressed by means of a JPEG algorithm at ratios of 10:1 and 20:1. Normal and abnormal sections (on original and compressed images) were reviewed by using a color soft-copy computed monochrome cathode ray tube monitor. Five observers rated the presence or absence of a lesion with a 50-point scale (0, definitely absent; 25, equivocal; and 50, definitely present). Diagnostic accuracy was evaluated with receiver operating characteristic (ROC) curve analysis. Significant difference was defined as a P value less than.05 for the area tested with a two-tailed paired Student t test. RESULTS: At ROC analysis, no statistically significant difference was detected for all cases considered together (Az [area under the ROC curve] = 0.887 +/- 0.038 [mean +/- SD] on noncompressed images, Az = 0.897 +/- 0.038 on 10:1 compressed images, and Az = 0.842 +/- 0.073 on 20:1 compressed images; P >.05). CONCLUSION: JPEG compression at ratios of 10:1 and 20:1 was tolerated in the detection of acute cerebral infarction at CT.


Assuntos
Infarto Cerebral/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Tomografia Computadorizada por Raios X , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA