Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Magn Reson Med ; 91(5): 1863-1875, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38192263

RESUMO

PURPOSE: To evaluate a vendor-agnostic multiparametric mapping scheme based on 3D quantification using an interleaved Look-Locker acquisition sequence with a T2 preparation pulse (3D-QALAS) for whole-brain T1, T2, and proton density (PD) mapping. METHODS: This prospective, multi-institutional study was conducted between September 2021 and February 2022 using five different 3T systems from four prominent MRI vendors. The accuracy of this technique was evaluated using a standardized MRI system phantom. Intra-scanner repeatability and inter-vendor reproducibility of T1, T2, and PD values were evaluated in 10 healthy volunteers (6 men; mean age ± SD, 28.0 ± 5.6 y) who underwent scan-rescan sessions on each scanner (total scans = 100). To evaluate the feasibility of 3D-QALAS, nine patients with multiple sclerosis (nine women; mean age ± SD, 48.2 ± 11.5 y) underwent imaging examination on two 3T MRI systems from different manufacturers. RESULTS: Quantitative maps obtained with 3D-QALAS showed high linearity (R2 = 0.998 and 0.998 for T1 and T2, respectively) with respect to reference measurements. The mean intra-scanner coefficients of variation for each scanner and structure ranged from 0.4% to 2.6%. The mean structure-wise test-retest repeatabilities were 1.6%, 1.1%, and 0.7% for T1, T2, and PD, respectively. Overall, high inter-vendor reproducibility was observed for all parameter maps and all structure measurements, including white matter lesions in patients with multiple sclerosis. CONCLUSION: The vendor-agnostic multiparametric mapping technique 3D-QALAS provided reproducible measurements of T1, T2, and PD for human tissues within a typical physiological range using 3T scanners from four different MRI manufacturers.


Assuntos
Encéfalo , Esclerose Múltipla , Masculino , Humanos , Feminino , Reprodutibilidade dos Testes , Estudos Prospectivos , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Esclerose Múltipla/diagnóstico por imagem , Mapeamento Encefálico
2.
AJNR Am J Neuroradiol ; 45(1): 66-71, 2023 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-38123957

RESUMO

BACKGROUND AND PURPOSE: Impaired glymphatic function has been suggested to be implicated in the pathophysiology of MS and aquaporin-4 immunoglobulin G-positive neuromyelitis optica spectrum disorder. This study aimed to investigate the interstitial fluid dynamics in the brain in patients with myelin oligodendrocyte glycoprotein antibody disorders (MOGAD), another demyelinating disorder, using a noninvasive imaging technique called the diffusivity along the perivascular space (ALPS) index. MATERIALS AND METHODS: A prospective study was conducted on 16 patients with MOGAD in remission and 22 age- and sex-matched healthy control subjects. MR imaging was performed using a 3T scanner, and the ALPS index was calculated using diffusion MR imaging data with a b-value of 1000 s/mm2. The ALPS index and gray matter volumes were compared between the 2 groups, and these parameters were correlated with the Expanded Disability Status Scale. RESULTS: The mean ALPS index of patients with MOGAD was significantly lower than that of healthy controls (Cohen d = 0.93, false discovery rate-corrected P = .02). The lower mean ALPS index was significantly associated with a worse Expanded Disability Status Scale score (Spearman ρ = -0.51; 95% CI, -0.85 to -0.02; P = .03). However, cortical volume and deep gray matter volume were not significantly different between the 2 groups, and they were not correlated with the Expanded Disability Status Scale. CONCLUSIONS: This study suggests that patients with MOGAD may have impaired glymphatic function, as measured by the ALPS index, which is associated with patient disability. Further study is warranted with a larger sample size.


Assuntos
Sistema Glinfático , Neuromielite Óptica , Humanos , Imunoglobulina G , Glicoproteína Mielina-Oligodendrócito , Estudos Prospectivos , Encéfalo , Autoanticorpos
3.
J Magn Reson Imaging ; 58(6): 1752-1759, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-36951614

RESUMO

BACKGROUND: Two-dimensional synthetic MRI of the breast has limited spatial coverage. Three-dimensional (3D) synthetic MRI could provide volumetric quantitative parameters that may reflect the immunohistochemical (IHC) status in invasive ductal carcinoma (IDC) of the breast. PURPOSE: To evaluate the feasibility of 3D synthetic MRI using an interleaved Look-Locker acquisition sequence with a T2 preparation pulse (QALAS) for discriminating the IHC status, including hormone receptor (HR), human epidermal growth factor receptor 2 (HER 2), and Ki-67 expression in IDC. STUDY TYPE: Prospective observational study. POPULATION: A total of 33 females with IDC of the breast (mean, 52.3 years). FIELD STRENGTH/SEQUENCE: A 3-T, 3D-QALAS gradient-echo and fat-suppressed T1-weighted 3D fast spoiled gradient-echo sequences. ASSESSMENT: Two radiologists semiautomatically delineated 3D regions of interest (ROIs) of the whole tumors on the dynamic MRI that was registered to the synthetic T1-weighted images acquired from 3D-QALAS. The mean T1 and T2 were measured for each IDC. STATISTICAL TESTS: Intraclass correlation coefficient for assessing interobserver agreement. Mann-Whitney U test to determine the relationship between the mean T1 or T2 and the IHC status. Multivariate logistic regression analysis followed by receiver operating characteristics (ROC) analysis for discriminating IHC status. A P value <0.05 was considered statistically significant. RESULTS: The interobserver agreement was good to excellent. There was a significant difference in the mean T1 between HR-positive and HR-negative lesions, while the mean T2 value differed between HR-positive and HR-negative lesions, between the triple-negative and HR-positive or HER2-positive lesions, and between the Ki-67 level > 14% and ≤ 14%. Multivariate analysis showed that the mean T2 was higher in HR-negative IDC than in HR-positive IDC. ROC analysis revealed that the mean T2 was predictive for discriminating HR status, triple-negative status, and Ki-67 level. DATA CONCLUSION: 3D synthetic MRI using QALAS may be useful for discriminating IHC status in IDC of the breast. EVIDENCE LEVEL: 1. TECHNICAL EFFICACY: Stage 2.


Assuntos
Neoplasias da Mama , Carcinoma Ductal de Mama , Carcinoma Ductal , Humanos , Feminino , Antígeno Ki-67 , Estudos de Viabilidade , Imageamento por Ressonância Magnética/métodos , Mama , Neoplasias da Mama/diagnóstico por imagem , Estudos Retrospectivos , Carcinoma Ductal de Mama/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA