1.
J Appl Toxicol ; 35(11): 1333-47, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25824844

RESUMO

The skin sensitization potential of chemicals has been determined with the use of the murine local lymph node assay (LLNA). However, in recent years public concern about animal welfare has led to a requirement for non-animal risk assessment systems for the prediction of skin sensitization potential, to replace LLNA. Selection of an appropriate in vitro test or in silico model descriptors is critical to obtain good predictive performance. Here, we investigated the utility of artificial neural network (ANN) prediction models using various combinations of descriptors from several in vitro sensitization tests. The dataset, collected from published data and from experiments carried out in collaboration with the Japan Cosmetic Industry Association (JCIA), consisted of values from the human cell line activation test (h-CLAT), direct peptide reactivity assay (DPRA), SH test and antioxidant response element (ARE) assay for chemicals whose LLNA thresholds have been reported. After confirming the relationship between individual in vitro test descriptors and the LLNA threshold (e.g. EC3 value), we used the subsets of chemicals for which the requisite test values were available to evaluate the predictive performance of ANN models using combinations of h-CLAT/DPRA (N = 139 chemicals), the DPRA/ARE assay (N = 69), the SH test/ARE assay (N = 73), the h-CLAT/DPRA/ARE assay (N = 69) and the h-CLAT/SH test/ARE assay (N = 73). The h-CLAT/DPRA, h-CLAT/DPRA/ARE assay and h-CLAT/SH test/ARE assay combinations showed a better predictive performance than the DPRA/ARE assay and the SH test/ARE assay. Our data indicates that the descriptors evaluated in this study were all useful for predicting human skin sensitization potential, although combinations containing h-CLAT (reflecting dendritic cell-activating ability) were most effective for ANN-based prediction.


Assuntos
Alternativas aos Testes com Animais/métodos , Redes Neurais de Computação , Testes Cutâneos/métodos , Pele/metabolismo , Linhagem Celular , Células Dendríticas/metabolismo , Humanos , Ensaio Local de Linfonodo , Medição de Risco , Sensibilidade e Especificidade
2.
J Appl Toxicol ; 35(11): 1318-32, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25820183

RESUMO

To develop a testing strategy incorporating the human cell line activation test (h-CLAT), direct peptide reactivity assay (DPRA) and DEREK, we created an expanded data set of 139 chemicals (102 sensitizers and 37 non-sensitizers) by combining the existing data set of 101 chemicals through the collaborative projects of Japan Cosmetic Industry Association. Of the additional 38 chemicals, 15 chemicals with relatively low water solubility (log Kow > 3.5) were selected to clarify the limitation of testing strategies regarding the lipophilic chemicals. Predictivities of the h-CLAT, DPRA and DEREK, and the combinations thereof were evaluated by comparison to results of the local lymph node assay. When evaluating 139 chemicals using combinations of three methods based on integrated testing strategy (ITS) concept (ITS-based test battery) and a sequential testing strategy (STS) weighing the predictive performance of the h-CLAT and DPRA, overall similar predictivities were found as before on the 101 chemical data set. An analysis of false negative chemicals suggested a major limitation of our strategies was the testing of low water-soluble chemicals. When excluded the negative results for chemicals with log Kow > 3.5, the sensitivity and accuracy of ITS improved to 97% (91 of 94 chemicals) and 89% (114 of 128). Likewise, the sensitivity and accuracy of STS to 98% (92 of 94) and 85% (111 of 129). Moreover, the ITS and STS also showed good correlation with local lymph node assay on three potency classifications, yielding accuracies of 74% (ITS) and 73% (STS). Thus, the inclusion of log Kow in analysis could give both strategies a higher predictive performance.


Assuntos
Alternativas aos Testes com Animais/métodos , Cosméticos/toxicidade , Pele/efeitos dos fármacos , Linhagem Celular , Cosméticos/química , Determinação de Ponto Final , Humanos , Ensaio Local de Linfonodo , Peptídeos/química , Valor Preditivo dos Testes , Medição de Risco , Sensibilidade e Especificidade , Testes Cutâneos , Solubilidade , Testes de Toxicidade , Água/química