Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
3.
JACC Cardiovasc Interv ; 17(11): 1340-1351, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38866457

RESUMO

BACKGROUND: The etiology of transcatheter aortic valve (TAV) degeneration is poorly understood, particularly noncalcific mechanisms. OBJECTIVES: The authors sought to investigate noncalcific and calcific mechanisms of TAV degeneration and evaluate their impact on leaflet function by bench testing, imaging, and histology. METHODS: TAV explants were obtained from the EXPLANT THV registry and clinical institutions. Hydrodynamic assessment was performed using a heart valve pulse duplicator system under physiological conditions. Micro-computed tomography, high-resolution photography, high speed video, and hematoxylin and eosin staining were used to evaluate the morphological appearance, leaflet kinematics, and calcium burden of TAVs. RESULTS: A total of 14 explants were evaluated: 10 self-expanding CoreValve/Evolut TAVs (Medtronic), 3 balloon-expandable SAPIEN 3 TAVs (Edwards Lifesciences), and 1 mechanically expandable Lotus TAV (Boston Scientific). The median patient age at explantation was 73.0 years (Q1-Q3: 64.5-80.0 years), with a time to explantation of 4 years 1 month (1 year 5 months to 4 years 11 months). Six TAV explants were found to have leaflet calcification (162.4 mm3; 58.8-603.0 mm3), and 8 had no calcification detectable by micro-computed tomography and histology. All samples had impaired leaflet kinematics. There was no significant difference in the hydrodynamic mean gradient between calcified (47.2 mm Hg; 26.6-74.1 mm Hg) and noncalcified (27.6 mm Hg; 15.2-36.7 mm Hg; P = 0.28) TAVs. Leaflet calcification had a weak but nonsignificant association with the hydrodynamic mean gradient (r = 0.42; P = 0.14). CONCLUSIONS: TAV function can be severely impacted by noncalcific and calcific mechanisms of tissue degeneration. Importantly, functional stenosis can occur in TAVs in the absence of obvious and significant calcification.


Assuntos
Valva Aórtica , Calcinose , Próteses Valvulares Cardíacas , Hidrodinâmica , Desenho de Prótese , Falha de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Microtomografia por Raio-X , Humanos , Idoso , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/patologia , Calcinose/fisiopatologia , Calcinose/diagnóstico por imagem , Calcinose/patologia , Calcinose/cirurgia , Feminino , Idoso de 80 Anos ou mais , Masculino , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Pessoa de Meia-Idade , Fatores de Tempo , Remoção de Dispositivo , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Hemodinâmica , Fenômenos Biomecânicos , Teste de Materiais , Gravação em Vídeo
4.
Int J Mol Sci ; 25(7)2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38612836

RESUMO

One of the most important medical interventions for individuals with heart valvular disease is heart valve replacement, which is not without substantial challenges, particularly for pediatric patients. Due to their biological properties and biocompatibility, natural tissue-originated scaffolds derived from human or animal sources are one type of scaffold that is widely used in tissue engineering. However, they are known for their high potential for immunogenicity. Being free of cells and genetic material, decellularized xenografts, consequently, have low immunogenicity and, thus, are expected to be tolerated by the recipient's immune system. The scaffold ultrastructure and ECM composition can be affected by cell removal agents. Therefore, applying an appropriate method that preserves intact the structure of the ECM plays a critical role in the final result. So far, there has not been an effective decellularization technique that preserves the integrity of the heart valve's ultrastructure while securing the least amount of genetic material left. This study demonstrates a new protocol with untraceable cells and residual DNA, thereby maximally reducing any chance of immunogenicity. The mechanical and biochemical properties of the ECM resemble those of native heart valves. Results from this study strongly indicate that different critical factors, such as ionic detergent omission, the substitution of Triton X-100 with Tergitol, and using a lower concentration of trypsin and a higher concentration of DNase and RNase, play a significant role in maintaining intact the ultrastructure and function of the ECM.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Animais , Suínos , Humanos , Criança , Xenoenxertos , Transplante Heterólogo , Engenharia Tecidual
5.
J Clin Med ; 13(5)2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38592316

RESUMO

Background. The significance of concomitant tricuspid regurgitation (TR) in the context of transcatheter aortic valve replacement (TAVR) remains unclear. This study aimed to analyze the severity of TR before and after TAVR with regard to short- and long-term survival and to analyze the influencing factors. Methods. In our retrospective analysis, TR before and after TAVR was examined and patients were classified into groups accordingly. Special attention was paid to patients with post-interventional changes in TR. Mortality after TAVR was considered the primary endpoint of the analysis and major complications according to the Valve Academic Research Consortium 3 (VARC3) were compared. Moreover, biomarkers and risk factors for worsening or improvement of TR through TAVR were analyzed. Results. Among 775 patients who underwent TAVR in our center between January 2009 and December 2019, 686 patients (89%) featured low- and 89 patients (11%) high-grade TR. High-grade pre-TAVR TR was associated with worse short- (30-day), mid- (2-year) and long-term survival up to 8 years. Even though in nearly half of the patients with high-grade TR the regurgitation improved within seven days after TAVR (n = 42/89), this did not result in a survival benefit for this subgroup. On the other hand, a worsening of low-grade TR was seen in more than 10% of the patients (n = 73/686), which was also associated with a worse prognosis. Predictors of worsening of TR after TAVR were adipositas, impaired right ventricular function and the presence of mild TR. Age, atrial fibrillation, COPD, impaired renal function and elevated cardiac biomarkers were risk factors for mortality after TAVR independent from the grade of TR. Conclusions. Not only pre-interventional, but also post-TAVR high-grade TR is associated with a worse prognosis after TAVR. TAVR can change concomitant tricuspid regurgitation, but improvement does not have any impact on short- and long-term survival. Worsening of TR after TAVR is possible and impairs the prognosis.

6.
EuroIntervention ; 20(6): e376-e388, 2024 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-38506739

RESUMO

BACKGROUND: There are limited data regarding treatment for failed balloon-expandable transcatheter heart valves (THVs) in redo-transcatheter aortic valve implantation (TAVI). AIMS: We aimed to assess THV performance, neoskirt height and expansion when performing redo-TAVI with the ACURATE platform inside a SAPIEN 3 (S3) compared to redo-TAVI with an S3 in an S3. METHODS: Redo-TAVI was performed on the bench using each available size of the S3, the ACURATE neo2 (ACn2) and the next-generation ACURATE Prime XL (AC XL) implanted at 2 different depths within 20 mm/23 mm/26 mm/29 mm S3s serving as the "failed" index THV. Hydrodynamic testing was performed to assess THV function. Multimodality assessment was performed using photography, X-ray, microcomputed tomography (micro-CT), and high-speed videos. RESULTS: The ACURATE in S3 combinations had favourable hydrodynamic performance compared to the S3 in S3 for all size combinations. In the 20 mm S3, redo-TAVI with the ACn2 had lower gradients compared to the S3 (mean gradient 16.3 mmHg for the ACn2 vs 24.7 mmHg for the 20 mm S3 in 20 mm S3). Pinwheeling was less marked for the ACURATE THVs than for the S3s. On micro-CT, the S3s used for redo-TAVI were underexpanded across all sizes. This was also observed for the ACURATE platform, but to a lesser extent. CONCLUSIONS: Redo-TAVI with an ACn2/AC XL within an S3 has favourable hydrodynamic performance and less pinwheeling compared to an S3 in S3. This comes at the price of a taller neoskirt.


Assuntos
Insuficiência Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Microtomografia por Raio-X , Catéteres , Valvas Cardíacas
7.
Radiol Cardiothorac Imaging ; 6(2): e220197, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38483246

RESUMO

Purpose To examine the relationship between smoking status and coronary volume-to-myocardial mass ratio (V/M) among individuals with coronary artery disease (CAD) undergoing CT fractional flow reserve (CT-FFR) analysis. Materials and Methods In this secondary analysis, participants from the ADVANCE registry evaluated for suspected CAD from July 15, 2015, to October 20, 2017, who were found to have coronary stenosis of 30% or greater at coronary CT angiography (CCTA) were included if they had known smoking status and underwent CT-FFR and V/M analysis. CCTA images were segmented to calculate coronary volume and myocardial mass. V/M was compared between smoking groups, and predictors of low V/M were determined. Results The sample for analysis included 503 current smokers, 1060 former smokers, and 1311 never-smokers (2874 participants; 1906 male participants). After adjustment for demographic and clinical factors, former smokers had greater coronary volume than never-smokers (former smokers, 3021.7 mm3 ± 934.0 [SD]; never-smokers, 2967.6 mm3 ± 978.0; P = .002), while current smokers had increased myocardial mass compared with never-smokers (current smokers, 127.8 g ± 32.9; never-smokers, 118.0 g ± 32.5; P = .02). However, both current and former smokers had lower V/M than never-smokers (current smokers, 24.1 mm3/g ± 7.9; former smokers, 24.9 mm3/g ± 7.1; never-smokers, 25.8 mm3/g ± 7.4; P < .001 [unadjusted] and P = .002 [unadjusted], respectively). Current smoking status (odds ratio [OR], 0.74 [95% CI: 0.59, 0.93]; P = .009), former smoking status (OR, 0.81 [95% CI: 0.68, 0.97]; P = .02), stenosis of 50% or greater (OR, 0.62 [95% CI: 0.52, 0.74]; P < .001), and diabetes (OR, 0.67 [95% CI: 0.56, 0.82]; P < .001) were independent predictors of low V/M. Conclusion Both current and former smoking status were independently associated with low V/M. Keywords: CT Angiography, Cardiac, Heart, Ischemia/Infarction Clinical trial registration no. NCT02499679 Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Feminino , Humanos , Masculino , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Coração , Miocárdio , Fumar/efeitos adversos
9.
Int J Mol Sci ; 24(24)2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-38139185

RESUMO

Transcatheter pulmonary valve replacement is a minimally-invasive alternative treatment for right ventricular outflow tract dysfunction and has been rapidly evolving over the past years. Heart valve prostheses currently available still have major limitations. Therefore, one of the significant challenges for the future is the roll out of transcatheter tissue engineered pulmonary valve replacement to more patients. In the present study, biodegradable poly-ε-caprolactone (PCL) nanofiber scaffolds in the form of a 3D leaflet matrix were successfully seeded with human endothelial colony-forming cells (ECFCs), human induced pluripotent stem cell-derived MSCs (hMSCs), and porcine MSCs (pMSCs) for three weeks for the generation of 3D tissue-engineered tri-leaflet valved stent grafts. The cell adhesion, proliferation, and distribution of these 3D heart leaflets was analyzed using fluorescence microscopy and scanning electron microscopy (SEM). All cell lineages were able to increase the overgrown leaflet area within the three-week timeframe. While hMSCs showed a consistent growth rate over the course of three weeks, ECFSs showed almost no increase between days 7 and 14 until a growth spurt appeared between days 14 and 21. More than 90% of heart valve leaflets were covered with cells after the full three-week culturing cycle in nearly all leaflet areas, regardless of which cell type was used. This study shows that seeded biodegradable PCL nanofiber scaffolds incorporated in nitinol or biodegradable stents will offer a new therapeutic option in the future.


Assuntos
Células-Tronco Pluripotentes Induzidas , Poliésteres , Humanos , Animais , Suínos , Poliésteres/farmacologia , Engenharia Tecidual , Alicerces Teciduais , Stents
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA