Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
2.
J Dent Res ; 95(3): 327-33, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26608579

RESUMO

Measurement of interfacial fracture toughness (iFT) is considered a more valid method to assess bonding effectiveness as compared with conventional bond strength testing. Common fracture toughness tests are, however, laborious and require a relatively bulky specimen size. This study aimed to evaluate a new simplified and miniaturized iFT (mini-iFT) test. Four dentin adhesives, representing the main adhesive classes, and 1 glass ionomer cement were applied onto flat dentin. Mini-iFT (1.5 × 2.0 × 16 to 18 mm) and microtensile bond strength (µTBS; 1.5 × 1.5 × 16 to 18 mm) specimens were prepared from the same tooth. For the mini-iFT specimens, a single notch was cut at the adhesive-dentin interface with a 150-µm diamond blade under water cooling; the specimens were loaded until failure in a 4-point bending test setup. Finite element analysis was used to analyze stress distribution during mini-iFT testing. The correlation between the mean mini-iFT and µTBS was examined and found to be significant; a strong positive correlation was found (r(2) = 0.94, P = 0.004). Weibull data analysis suggested the mini-iFT to vary less than the µTBS. Both the mini-iFT and the µTBS revealed the same performance order, with the 3-step etch-and-rinse adhesive outperforming the 2-step self-etch and 2-step etch-and-rinse adhesive, followed by the 1-step SE adhesive and, finally, the glass ionomer cement. Scanning electron microscopy failure analysis revealed the adhesive-dentin interface to fail more at the actual interface with the mini-iFT test, while µTBS specimens failed more within dentin and composite. This finding was corroborated by finite element analysis showing stress to concentrate at the interface during mini-iFT loading and crack propagation. In conclusion, the new mini-iFT test appeared more discriminative and valid than the µTBS to assess bonding effectiveness; the latter test nevertheless remains more versatile. Specimen size and workload were alike, making the mini-iFT test a valid alternative for the popular µTBS test.


Assuntos
Colagem Dentária , Adesivos Dentinários/química , Adesividade , Resinas Compostas/química , Corrosão Dentária/métodos , Análise do Estresse Dentário/instrumentação , Dentina/ultraestrutura , Análise de Elementos Finitos , Cimentos de Ionômeros de Vidro/química , Humanos , Teste de Materiais/métodos , Microscopia Eletrônica de Varredura , Miniaturização , Maleabilidade , Reprodutibilidade dos Testes , Cimentos de Resina/química , Dióxido de Silício/química , Estresse Mecânico , Propriedades de Superfície , Resistência à Tração , Zircônio/química
3.
J Clin Pediatr Dent ; 39(3): 224-30, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26208066

RESUMO

AIM: The aim of this study was to evaluate the effects of a smear layer generated by a high-speed diamond or carbide bur on the durability of microtensile bond strength (µTBS) of a self-etching adhesive to primary dentin. STUDY DESIGN: Flat occlusal dentin surfaces of 105 human primary molars were exposed using 600 grit silicon carbide paper before being divided into 2 groups for further grinding with either a highspeed diamond or carbide bur. Ten prepared dentin surfaces treated by each bur were evaluated for the characteristics of the smear layer using a scanning electron microscope (SEM). Seventy-five specimens from each bur-prepared group were applied with a 2-step self-etching adhesive (Clearfil SE Bond(®)) then built up with a resin composite. Each bonded specimen was sectioned into a 1-mm thick slab and trimmed to a dumbbell shape with a cross-sectional area of approximately 1 mm(2). All slabs were divided into 3 groups (n=25) according to 3 storage times of 24 hrs, 3 months, and 6 months, in distilled water at 37°C. After storage, the µTBS was determined using a universal testing machine. All fracture specimens were prepared for observation of failure modes. Ten bonded specimens of each bur group were prepared for observation of the resin-dentin interface using an SEM. Smear-layer thickness, µTBS, and failure mode distributions were statistically analyzed. RESULTS: The high speed carbide bur created a significantly thinner smear layer than the diamond bur (p < 0.05). Dentin surfaces treated with a high-speed carbide bur generally obtained significantly higher µTBS than the diamond bur group (p < 0.05). The µTBS gradually decreased over time such that specimens stored for 6 months had significantly lower bond strength than those stored for 24 hrs (p < 0.05). Self-etching adhesive created a hybrid layer of the same thickness when prepared with either a carbide bur or diamond bur, but the carbide bur group had longer and more resin tags. CONCLUSION: Highspeed carbide bur groups had a higher µTBS than diamond bur groups for all storage times, and bond strengths decreased over time in both substrate groups. The use of a carbide bur produced a thinner smear layer and therefore is recommended when using this 2-step self-etching adhesive to bond the resin composite to primary dentin.


Assuntos
Colagem Dentária , Equipamentos Odontológicos de Alta Rotação , Adesivos Dentinários/química , Dentina/ultraestrutura , Camada de Esfregaço/ultraestrutura , Dente Decíduo/ultraestrutura , Compostos Inorgânicos de Carbono/química , Resinas Compostas/química , Materiais Dentários/química , Análise do Estresse Dentário/instrumentação , Diamante/química , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Dente Molar/ultraestrutura , Cimentos de Resina/química , Estresse Mecânico , Temperatura , Resistência à Tração , Fatores de Tempo , Água/química
4.
Arch Oral Biol ; 55(1): 34-9, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20005510

RESUMO

OBJECTIVE: Streptococcus mutans, known to be a major pathogen of dental caries, is also considered to cause infective endocarditis. Its 120-kDa Cnm protein binds to type I collagen, which may be a potential virulence factor. In this study, we characterized S. mutans clinical strains focusing on the cnm gene encoding Cnm. DESIGN: A total of 528 S. mutans strains isolated from Japanese, Finnish, and Thai subjects were investigated. Using molecular techniques, the distribution frequency of cnm-positive strains and location of the inserted cnm were analyzed. Furthermore, isogenic mutant strains were constructed by inactivation of the cnm gene, then their biological properties of collagen-binding and glucan-binding were evaluated. Southern hybridization of the genes encoding glucan-binding proteins was also performed. RESULTS: The distribution frequency of cnm-positive strains from Thai subjects was 12%, similar to that previously reported for Japanese and Finnish subjects. Furthermore, the location of insertion of cnm was the same in all cnm-positive clinical isolates. As for the cnm-inactivated mutant strains constructed from 28 clinical isolates, their collagen-binding activity was negligible. In addition, glucan-binding activity in the cnm-positive clinical isolates was significantly reduced and corresponded to a lack of gbpA encoding glucan-binding protein A. CONCLUSIONS: Our results indicate that strains with cnm genes, the most crucial factor for the collagen-binding property of S. mutans, are detectable at similar frequencies over several different geographic locations. In addition, the common properties of these strains are a high level of collagen-binding activity and tendency for a low level of glucan-binding activity.


Assuntos
Adesinas Bacterianas/genética , Proteínas de Transporte/genética , Colágeno/metabolismo , Streptococcus mutans/genética , Southern Blotting , Cárie Dentária/microbiologia , Finlândia , Regulação Bacteriana da Expressão Gênica/fisiologia , Glucanos/metabolismo , Humanos , Japão , Reação em Cadeia da Polimerase , Ligação Proteica/genética , Saliva/microbiologia , Streptococcus mutans/isolamento & purificação , Streptococcus mutans/patogenicidade , Tailândia
5.
Oral Microbiol Immunol ; 24(5): 431-3, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19702960

RESUMO

INTRODUCTION: Streptococcus mutans, known to be a pathogen of dental caries as well as bacteremia and infective endocarditis, is classified into four serotypes, c, e, f and k, based on the structures of serotype-specific polysaccharides. Serotype k was recently designated using blood isolates from Japanese subjects and such strains are considered to be virulent in the bloodstream. The purpose of the present study was to analyse the serotype distribution of strains isolated from Thai subjects and determine whether serotype k strains were present. METHODS: A total of 250 S. mutans strains were isolated from 50 Thai subjects, and serotypes of all strains were determined. Then, molecular and biological analyses were carried out for serotype k strains. RESULTS: Immunodiffusion and polymerase chain reaction analyses showed that serotype c was the most prevalent (70%), followed by serotypes e (22.8%), f (4.4%) and k (2.8%), which indicated that serotype k S. mutans strains occurred in Thai individuals at a similar rate to that previously reported for Japanese and Finnish populations. Molecular analyses of the seven serotype k strains showed extremely low expression of rgpE, which is related to glucose side-chain formation in serotype-specific rhamnose-glucose polymers, similar to previous reports for those other populations. In addition, analysis of the biological properties of the seven serotype k strains demonstrated low levels of sucrose-dependent adhesion, cellular hydrophobicity, dextran-binding activity and phagocytosis susceptibility by human polymorphonuclear leukocytes, which are characteristics similar to those of serotype k strains previously isolated in Japan. CONCLUSION: Our results indicate the possibility of a worldwide prevalence of serotype k strains with properties in common with those of previously reported strains.


Assuntos
Sorotipagem , Streptococcus mutans/classificação , Adolescente , Adulto , Aderência Bacteriana/fisiologia , Proteínas de Bactérias/análise , Dextranos/metabolismo , Feminino , Glucosiltransferases/análise , Humanos , Interações Hidrofóbicas e Hidrofílicas , Imunodifusão , Japão , Masculino , Pessoa de Meia-Idade , Neutrófilos/fisiologia , Fagocitose/fisiologia , Reação em Cadeia da Polimerase , Polissacarídeos Bacterianos/análise , Streptococcus mutans/patogenicidade , Sacarose/metabolismo , Tailândia , Virulência , Adulto Jovem
6.
Oper Dent ; 34(4): 415-22, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19678446

RESUMO

The current study evaluated the micro-shear bond strength of two resin cements to astringent-contaminated dentin. Twelve occlusal dentin discs were prepared from extracted caries-free human molars and divided into two groups subjected to two types of resin cements, Panavia F (PF) and Variolink II (VL). Each disc was ground with 600 grit SiC paper and sectioned into two semi-disks, one for the normal dentin surface and the other for the contaminated dentin surface. For contaminated dentin, an astringent containing aluminum chloride was applied for two minutes and rinsed before the bonding procedures. A micro tygon tube was placed on the dentin surface following the bonding application and then filled with a resin cement. After the resin was polymerized, the specimen was kept in water for 24 hours before the micro-shear bond strengths evaluation. The micro morphology of the treated surfaces and resin-dentin interfaces were observed under a scanning electron microscope (SEM). Aluminum content under different dentin conditions was also examined. No significant differences were found between the dentin bond strengths to normal dentin and contaminated dentin surfaces in both the PF and VL groups (p>0.05). PF showed similar bond strengths to VL on normal and contaminated dentin (p>0.05). SEM observations of the VL groups revealed no differences in the treated dentin surfaces and the resin-dentin interfaces between normal and contaminated dentin. However, for the PF group, an inconsistent etching pattern of the self-etching primer and gap formation at the interface of resin cement to contaminated dentin were observed.


Assuntos
Adstringentes/farmacologia , Colagem Dentária , Análise do Estresse Dentário , Cimentos de Resina , Dentina/efeitos dos fármacos , Adesivos Dentinários , Humanos , Técnicas In Vitro , Resistência ao Cisalhamento
7.
J Dent Res ; 86(3): 232-6, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17314254

RESUMO

Studies have reported the discoloration of dentin beneath amalgam restorations. The purpose of this study was to test the hypothesis that the bond strengths of adhesive resins to this discolored dentin are lower than those to normal dentin, and are related to the presence of metallic ions or corrosion products. Amalgam-filled extracted human teeth were used. After the removal of amalgam, the discolored dentin and surrounding normal dentin were bonded with Single Bond or Clearfil SE Bond and tested for microtensile bond strengths. The bond strengths of Single Bond and Clearfil SE Bond to normal dentin were greater than to discolored dentin. Clearfil SE Bond demonstrated higher bond strength to normal dentin than did Single Bond. However, no differences were found between the bond strengths to the discolored dentin of both adhesives. Elemental micro-analysis revealed various amounts of tin in all discolored dentin.


Assuntos
Amálgama Dentário/efeitos adversos , Colagem Dentária , Adesivos Dentinários , Cimentos de Resina , Descoloração de Dente/etiologia , Análise de Variância , Bis-Fenol A-Glicidil Metacrilato , Corrosão , Análise do Estresse Dentário , Dentina/patologia , Microanálise por Sonda Eletrônica , Dureza , Humanos , Íons , Estatísticas não Paramétricas , Resistência à Tração , Estanho/análise
8.
Oper Dent ; 29(2): 196-202, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15088732

RESUMO

PURPOSE: To evaluate the bond strength of a total-etching, self-priming system (Single Bond) and a self-etching system (Clearfil SE Bond) to deciduous and permanent human dentin. METHODS AND MATERIALS: Buccal dentin discs were prepared with a diamond disc from permanent first premolars, permanent third molars and deciduous second molars. The flat dentin surfaces were obtained by polishing with wet 600 grit silicon carbide papers. The specimens of each group were further divided into two groups for bonding to either Single Bond or Clearfil SE Bond. After 24 hours, the microshear bond strength testing was executed on a universal testing machine. Statistical analysis was performed at alpha = 0.05. RESULTS: No significant differences in bond strength were found between materials. However, deciduous dentin demonstrated significantly lower bond strengths than permanent premolar dentin when Single Bond was applied (p < 0.05). CONCLUSION: The difference in bonding substrate (permanent or deciduous dentin) had a significant effect on bond strength when the total-etching, self-priming system was applied.


Assuntos
Colagem Dentária , Adesivos Dentinários , Dentina , Cimentos de Resina , Condicionamento Ácido do Dente , Análise de Variância , Bis-Fenol A-Glicidil Metacrilato , Resinas Compostas , Análise do Estresse Dentário , Permeabilidade da Dentina , Dentição Permanente , Humanos , Microscopia Eletrônica de Varredura , Resistência ao Cisalhamento , Estatísticas não Paramétricas , Dente Decíduo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA