Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-39422931

RESUMO

BACKGROUND: Monitoring liver changes is crucial in the management of liver fibrosis. Current diagnostic methods include liver function tests such as the Liver Maximum Capacity (LiMAx) test and measurements of liver stiffness. While the LiMAx test quantifies liver function through 13C-methacetin metabolism, ultrasound (US) elastography noninvasively assesses liver stiffness. The relationship between the findings of these methods in patients with liver fibrosis is not fullyunderstood. OBJECTIVE: This study evaluated the correlation between LiMAx measurements of liver function and US elastography-based liver stiffness measurements to better understand the interplay between functional and structural liver parameters in fibrotic liver disease. Additionally, the relationship between body mass index (BMI) and these parameters isevaluated. METHODS: This retrospective study analysed data from 97 patients who underwent both LiMAx testing and real-time elastography, resulting in a total data set of 108 examinations. The correlations between the results of the LiMAx test and elastography and their relationships with body mass index (BMI) were analysed. RESULTS: There was a significant negative correlation (r = -0.25, p < 0.05) between LiMAx test values and liver stiffness measurements. BMI was significantly negatively correlated with LiMAx values (r = -0.29, p < 0.001) but not significantly correlated with liver stiffness values. CONCLUSIONS: This retrospective study confirms the results of previous studies showing a notable but weak association between liver function and liver stiffness. Our results highlight the potential value of both tests as complementary tools for the evaluation of liver health, reinforcing the necessity for a multimodal approach to liver assessment.

2.
Tomography ; 10(2): 243-254, 2024 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-38393287

RESUMO

PURPOSE: To evaluate magnetic resonance image (MRI) findings in children and adolescents suffering from knee pain without traumatic or physical overload history and to identify potential anatomic risk factors. MATERIAL AND METHODS: A total of 507 MRIs of 6- to 20-year-old patients (251 males; 256 females) were evaluated with regard to detectable pathologies of the knee. The results were compared to a control group without pain (n = 73; 34 males; 39 females). A binary logistic regression model and t-tests for paired and unpaired samples were used to identify possible risk factors and significant anatomic differences of the study population. RESULTS: In 348 patients (68.6%), at least one pathology was detected. The most commonly detected finding was chondromalacia of the patellofemoral (PF) joint (n = 205; 40.4%). Chondral lesions of the PF joint occurred significantly more often in knee pain patients than in the control group (40% vs. 11.0%; p = 0.001), especially in cases of a patella tilt angle > 5° (p ≤ 0.001), a bony sulcus angle > 150° (p = 0.002), a cartilaginous sulcus angle > 150° (p = 0.012), a lateral trochlear inclination < 11° (p ≤ 0.001), a lateralised patella (p = 0.023) and a Wiberg type II or III patella shape (p = 0.019). Moreover, a larger patella tilt angle (p = 0.021), a greater bony sulcus angle (p = 0.042), a larger cartilaginous sulcus angle (p = 0.038) and a lower value of the lateral trochlear inclination (p = 0.014) were detected in knee pain patients compared to the reference group. CONCLUSION: Chondromalacia of the PF joint is frequently observed in children and adolescents suffering from non-overload atraumatic knee pain, whereby a patella tilt angle > 5°, a bony sulcus angle > 150°, a cartilaginous sulcus angle > 150°, a lateral trochlear inclination < 11°, a lateralised patella and a Wiberg type II or III patella shape seem to represent anatomic risk factors.


Assuntos
Doenças das Cartilagens , Articulação Patelofemoral , Masculino , Criança , Feminino , Humanos , Adolescente , Adulto Jovem , Adulto , Articulação Patelofemoral/diagnóstico por imagem , Articulação Patelofemoral/patologia , Imageamento por Ressonância Magnética , Doenças das Cartilagens/patologia , Dor/diagnóstico por imagem , Dor/patologia , Fatores de Risco
3.
Clin Hemorheol Microcirc ; 86(1-2): 213-224, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37638427

RESUMO

BACKGROUND: Local ablation is an important treatment for liver cancer in cases of cirrhosis. Liver failure may occur after ablation, especially in advanced liver diseases. Currently, there is no standardization for peri-interventional risk assessment. The liver maximum capacity test (LiMAx) is used to assess functional liver capacity, but there is a lack of exploration of its use in this context. OBJECTIVE: The aim of this study was to retrospectively evaluate the usefulness of peri-interventional LiMAx measurements in patients with primary or secondary liver cancer who underwent ablation treatment. METHODS: A LiMAx test was performed at 24 hours pre- and postablation in 49 patients. Blood parameters were collected to determine liver function using MELD and ALBI scores. The results of the LiMAx test were related with these scores and to critical postintervention LiMAx values. RESULTS: LiMAx values correlated strongly with MELD and ALBI scores before the intervention and reflected the change in liver function, as shown by an increase in scores after the intervention. Notably, LiMAx values decreased during the intervention. AUC analysis for patients at risk of reaching a critical liver level after the intervention showed a cutoff value of 186µg/kg/h. CONCLUSIONS: The LiMAx test may be a valuable tool in liver ablation for both peri-interventional monitoring of liver function and preintervention risk assessment.


Assuntos
Neoplasias Hepáticas , Humanos , Estudos Retrospectivos , Estudos de Viabilidade , Testes de Função Hepática , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/cirurgia
4.
Sci Rep ; 13(1): 13121, 2023 08 12.
Artigo em Inglês | MEDLINE | ID: mdl-37573451

RESUMO

Monitoring disease progression is particularly important for determining the optimal treatment strategy in patients with liver disease. Especially for patients with diseases that have a reversible course, there is a lack of suitable tools for monitoring liver function. The development and establishment of such tools is very important, especially in view of the expected increase in such diseases in the future. Image-based liver function parameters, such as the T1 relaxometry-based MELIF score, are ideally suited for this purpose. The determination of this new liver function score is fully automated by software developed with AI technology. In this study, the MELIF score is compared with the widely used ALBI score. The ALBI score was used as a benchmark, as it has been shown to better capture the progression of less severe liver disease than the MELD and Child‒Pugh scores. In this study, we retrospectively determined the ALBI and MELIF scores for 150 patients, compared these scores with the corresponding MELD and Child‒Pugh scores (Pearson correlation), and examined the ability of these scores to discriminate between good and impaired liver function (AUC: MELIF 0.8; ALBI 0.77) and to distinguish between patients with and without cirrhosis (AUC: MELIF 0.83, ALBI 0.79). The MELIF score performed more favourably than the ALBI score and may also be suitable for monitoring mild disease progression. Thus, the MELIF score is promising for closing the gap in the available early-stage liver disease monitoring tools (i.e., identification of liver disease at a potentially reversible stage before chronic liver disease develops).


Assuntos
Meios de Contraste , Hepatopatias , Humanos , Estudos Retrospectivos , Hepatopatias/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Progressão da Doença
5.
Diagnostics (Basel) ; 12(7)2022 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-35885653

RESUMO

In the management of patients with chronic liver disease, the assessment of liver function is essential for treatment planning. Gd-EOB-DTPA-enhanced MRI allows for both the acquisition of anatomical information and regional liver function quantification. The objective of this study was to demonstrate and evaluate the diagnostic performance of two fully automatically generated imaging-based liver function scores that take the whole liver into account. T1 images from the native and hepatobiliary phases and the corresponding T1 maps from 195 patients were analyzed. A novel artificial-intelligence-based software prototype performed image segmentation and registration, calculated the reduction rate of the T1 relaxation time for the whole liver (rrT1liver) and used it to calculate a personalized liver function score, then generated a unified score-the MELIF score-by combining the liver function score with a patient-specific factor that included weight, height and liver volume. Both scores correlated strongly with the MELD score, which is used as a reference for global liver function. However, MELIF showed a stronger correlation than the rrT1liver score. This study demonstrated that the fully automated determination of total liver function, regionally resolved, using MR liver imaging is feasible, providing the opportunity to use the MELIF score as a diagnostic marker in future prospective studies.

6.
Front Med (Lausanne) ; 9: 839919, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35463008

RESUMO

Liver disease and hepatocellular carcinoma (HCC) have become a global health burden. For this reason, the determination of liver function plays a central role in the monitoring of patients with chronic liver disease or HCC. Furthermore, assessment of liver function is important, e.g., before surgery to prevent liver failure after hepatectomy or to monitor the course of treatment. Liver function and disease severity are usually assessed clinically based on clinical symptoms, biopsy, and blood parameters. These are rather static tests that reflect the current state of the liver without considering changes in liver function. With the development of liver-specific contrast agents for MRI, noninvasive dynamic determination of liver function based on signal intensity or using T1 relaxometry has become possible. The advantage of this imaging modality is that it provides additional information about the vascular structure, anatomy, and heterogeneous distribution of liver function. In this review, we summarized and discussed the results published in recent years on this technique. Indeed, recent data show that the T1 reduction rate seems to be the most appropriate value for determining liver function by MRI. Furthermore, attention has been paid to the development of automated tools for image analysis in order to uncover the steps necessary to obtain a complete process flow from image segmentation to image registration to image analysis. In conclusion, the published data show that liver function values obtained from contrast-enhanced MRI images correlate significantly with the global liver function parameters, making it possible to obtain both functional and anatomic information with a single modality.

7.
Clin Hemorheol Microcirc ; 79(1): 73-80, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34487035

RESUMO

BACKGROUND AND OBJECTIVE: Liver function is one of the most important parameters for the outcome of transarterial chemoembolization (TACE). The liver maximum capacity (LiMAx) test is a bedside test that provides a real-time option for liver function testing. The objective of this pilot study was to investigate the suitability of the LiMAX test for predicting the TACE outcome. METHODS: 20 patients with intermediate-stage hepatocellular carcinoma (HCC) received a LiMAx test 24 h pre and post TACE. In addition, laboratory values were collected to determine liver function and model for endstage liver disease (MELD) scores. The success of TACE was assessed 6 weeks post intervention by morphological imaging tests using modified response evaluation criteria in solid tumors (mRECIST). RESULTS: Patients with an objective response (OR = CR + PR) according to mRECIST post TACE had significantly higher values in the pre-interventional LiMAx test than patients with a non-OR (PD or SD) post TACE (r(14) = 0.62, p = 0.01). Higher pre-interventional LiMAx values therefore indicate OR. Patients with a disease control (DC = CR + PR + SD) according to mRECIST post TACE had significantly higher values in the pre-interventional LiMAx test than patients with a non-DC (PD) post TACE (r(14) = 0.65, p = 0.01). Higher pre-interventional LiMAx values therefore indicate DC. The point biserial correlations of LiMAx values pre and post TACE with the outcome OR or DC were descriptively stronger than those of MELD with OR or DC. This suggests that the LiMAx test correlates better with the treatment response than the MELD score. CONCLUSIONS: For the first time, we were able to show in our study that patients who are scheduled for TACE could benefit from a LiMAx test to be able to estimate the benefit of TACE. The higher the pre-interventional LiMAx values, the higher the benefit of TACE. On the other hand, laboratory parameters summarized in the form of the MELD score had significantly less descriptive correlation with the TACE outcome.


Assuntos
Carcinoma Hepatocelular , Quimioembolização Terapêutica , Neoplasias Hepáticas , Acetamidas , Testes Respiratórios , Isótopos de Carbono , Carcinoma Hepatocelular/terapia , Humanos , Neoplasias Hepáticas/terapia , Projetos Piloto , Estudos Retrospectivos , Resultado do Tratamento
8.
PLoS One ; 15(11): e0242093, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33201902

RESUMO

PURPOSE: To evaluate the appearance and size of ablation zones in gadoxetic-acid-enhanced magnetic resonance imaging (MRI) during the first year after irreversible electroporation (IRE) of primary or secondary hepatic malignancies and to investigate potential correlations to clinical features. MATERIAL AND METHODS: The MRI-appearance of the ablation area was assessed 1-3 days, 6 weeks, 3 months, 6 months, 9 months and 1 year after IRE. The size of the ablation zone and signal intensities of each follow-up control were compared. Moreover, relationships between clinical features and the MRI-appearance of the ablation area 1-3 days after IRE were analyzed. RESULTS: The ablation zone size decreased from 5.6 ± 1.4 cm (1-3 days) to 3.7±1.2 cm (1 year). A significant decrease of central hypointensities was observed in T2-blade- (3 months), T2 haste- (6 weeks; 3 months; 6 months; 1 year), T1 arterial phase- (3 months; 1 year), and diffusion-sequences (6 weeks; 3 months; 6 months; 9 months; 1 year). The unenhanced T1-sequences showed significantly increasing central hypointensities (6 weeks; 3 months; 6 months; 9 months; 1 year). Significantly increasing peripheral hypointensities were detected in T1 arterial phase- (3 months; 6 months; 9 months; 1 year) and in T1 portal venous phase-sequences (6 weeks; 3 months; 6 months; 9 months; 1 year). Peripheral hypointensities of unenhanced T1-sequences decreased significantly 1 year after IRE. 1-3 days after IRE central T1 portal venous hypo- or isointensities were detected significantly more often than hyperintensities, if more than 3 IRE electrodes were used. CONCLUSION: Hepatic IRE results in continuous reduction of ablation zone size during the first postinterventional year. In addition to centrally decreasing T1-signal and almost steadily increasing signal in the enhanced T2 haste-, diffusion- and T1 arterial phase-sequences, there is a trend toward long-term decreasing T1 arterial- and portal venous MRI-signal intensity of the peripheral ablation area, probably representing a region of reversible electroporation.


Assuntos
Eletroquimioterapia , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Gadolínio DTPA , Artéria Hepática/diagnóstico por imagem , Humanos , Neoplasias Hepáticas/tratamento farmacológico , Masculino , Pessoa de Meia-Idade , Veia Porta/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA