Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 13(1): 15798, 2023 09 22.
Artigo em Inglês | MEDLINE | ID: mdl-37737248

RESUMO

Conventional chemotherapy methods have adverse off-target effects and low therapeutic efficiencies of drug release in target tumors. In this study, we proposed a combination therapy of doxorubicin (DOX)-loaded ultrasound (US)-sensitive liposomal nanocarriers (IMP301), microbubbles (MBs) under focused US exposure using convex acoustic lens-attached US (LENS) to tumor treatment. The therapeutic effects of each treatment in a murine melanoma model were evaluated using contrast-enhanced US (CEUS) and micro-computed tomography (micro-CT) imaging, bioluminescence and confocal microscopy imaging, and liquid chromatography-mass spectroscopy (LC/MS) analysis. Tumor-bearing mice were randomly assigned to one of the following groups: (1) G1: IMP301 only (n = 9); (2) G2: IMP301 + LENS (n = 9); (3) G3: IMP301 + MB + LENS (n = 9); (4) G4: DOXIL only (n = 9); and (5) G5: IMP301 without DOXIL group as a control group (n = 4). Ten days after tumor injection, tumor-bearing mice were treated according to each treatment strategy on 10th, 12th, and 14th days from the day of tumor injection. The CEUS images of the tumors in the murine melanoma model clearly showed increased echo signal intensity from MBs as resonant US scattering. The relative tumor volume of the G2 and G3 groups on the micro-CT imaging showed inhibited tumor growth than the reference baseline of the G5 group. DOX signals on bioluminescence and confocal microscopy imaging were mainly located at the tumor sites. LC/MS showed prominently higher intratumoral DOX concentration in the G3 group than in other treated groups. Therefore, this study effectively demonstrates the feasibility of the synergistic combination of IMP301, MBs, and LENS-application for tumor-targeted treatment. Thus, this study can enable efficient tumor-targeted treatment by combining therapy such as IMP301 + MBs + LENS-application.


Assuntos
Lipossomos , Melanoma , Animais , Camundongos , Estudos de Viabilidade , Microbolhas , Microtomografia por Raio-X , Melanoma/diagnóstico por imagem , Melanoma/tratamento farmacológico , Acústica
2.
Med Phys ; 50(6): 3816-3824, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36700450

RESUMO

BACKGROUND: The machine-specific reference (msr) correction factors ( k Q msr , Q 0 f msr , f ref $k_{{Q_{{\rm{msr}}}},\;{Q_0}}^{{f_{{\rm{msr}}}},{f_{{\rm{ref}}}}}$ ) were introduced in International Atomic Energy Agency (IAEA) Technical Report Series 483 (TRS-483) for reference dosimetry of small fields. Several correction factor sets exist for a Leksell Gamma Knife (GK) Perfexion or Icon. Nevertheless, experiments have not rigorously validated the correction factors from different studies. PURPOSE: This study aimed to assess the role and accuracy of k Q msr , Q 0 f msr , f ref $k_{{Q_{{\rm{msr}}}},\;{Q_0}}^{{f_{{\rm{msr}}}},{f_{{\rm{ref}}}}}$ values in determining the absorbed dose rates to water in the reference dosimetry of Gamma Knife. METHODS: The dose rates in the 16 mm collimator field of a GK were determined following the international code of practices with three ionization chambers: PTW T31010, PTW T31016 (PTW Freiberg GmbH, New York, NY), and Exradin A16 (Standard Imaging, Inc., Middleton, WI). A chamber was placed at the center of a solid water phantom (Elekta AB, Stockholm, Sweden) using a detector-specific insert. The reference point of the ionization chamber was confirmed using cone-beam CT images. Consistency checks were repeated five times at a GK site and performed once at seven GK sites. Correction factors from six simulations reported in previous studies were employed. Variations in the dose rates and relative dose rates before and after applying the k Q m s r , Q 0 f m s r , f r e f $k_{{Q_{msr}},\;{Q_0}}^{{f_{msr}},{f_{ref}}}$ were statistically compared. RESULTS: The standard deviation of the dose rates measured by the three chambers decreased significantly after any correction method was applied (p = 0.000). When the correction factors of all studies were averaged, the standard deviation was reduced significantly more than when any single correction method was applied (p ≤ 0.030), except for the IAEA TRS-483 correction factors (p = 0.148). Before any correction was applied, there were statistically significant differences among the relative dose rates measured by the three chambers (p = 0.000). None of the single correction methods could remove the differences among the ionization chambers (p ≤ 0.038). After TRS-483 correction, the dose rate of Exradin A16 differed from those of the other two chambers (p ≤ 0.025). After the averaged factors were applied, there were no statistically significant differences between any pairs of chambers according to Scheffe's post hoc analyses (p ≥ 0.051); however, PTW T31010 differed from PTW 31016 according to Tukey's HSD analyses (p = 0.040). CONCLUSION: The k Q msr , Q 0 f msr , f ref $k_{{Q_{{\rm{msr}}}},\;{Q_0}}^{{f_{{\rm{msr}}}},{f_{{\rm{ref}}}}}$ significantly reduced variations in the dose rates measured by the three ionization chambers. The mean correction factors of the six simulations produced the most consistent results, but this finding was not explicitly proven in the statistical analyses.


Assuntos
Radiocirurgia , Radiocirurgia/métodos , Radiometria/métodos , Imagens de Fantasmas , Água , Agências Internacionais
SELEÇÃO DE REFERÊNCIAS