Med Phys ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38748998

RESUMO

BACKGROUND: A dosimeter with high spatial and temporal resolution would be of significant interest for pencil beam scanning (PBS) proton beams' characterization, especially when facing small fields and beams with high temporal dynamics. Optical imaging of scintillators has potential in providing sub-millimeter spatial resolution with pulse-by-pulse basis temporal resolution when the imaging system is capable of operating in synchrony with the beam-producing accelerator. PURPOSE: We demonstrate the feasibility of imaging PBS proton beams as they pass through a plastic scintillator detector to simultaneously obtain multiple beam parameters, including proton range, pencil beam's widths at different depths, spot's size, and spot's position on a pulse-by-pulse basis with sub-millimeter resolution. MATERIALS AND METHODS: A PBS synchrocyclotron was used for proton irradiation. A BC-408 plastic scintillator block with 30 × 30 × 5 cm3 size, and another block with 30 × 30 × 0.5 cm3 size, positioned in an optically sealed housing, were used sequentially to measure the proton range, and spot size/location, respectively. A high-speed complementary metal-oxide-semiconductor (CMOS) camera system synchronized with the accelerator's pulses through a gating module was used for imaging. Scintillation images, captured with the camera directly facing the 5-cm-thick scintillator, were corrected for background (BG), and ionization quenching of the scintillator to obtain the proton range. Spots' position and size were obtained from scintillation images of the 0.5-cm-thick scintillator when a 45° mirror was used to reflect the scintillation light toward the camera. RESULTS: Scintillation images with 0.16 mm/pixel resolution corresponding to all proton pulses were captured. Pulse-by-pulse analysis showed that variations of the range, spots' position, and size were within ± 0.2% standard deviation of their average values. The absolute ranges were within ± 1 mm of their expected values. The average spot-positions were mostly within ± 0.8 mm and spots' sigma agreed within 0.2 mm of the expected values. CONCLUSION: Scintillation-imaging PBS beams with high-spatiotemporal resolution is feasible and may help in efficient and cost-effective acceptance testing and commissioning of existing and even emerging technologies such as FLASH, grid, mini-beams, and so forth.

2.
Med Phys ; 48(9): 5459-5471, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34318488

RESUMO

PURPOSE: Accurate two-dimensional (2D) profile measurements at submillimeter precision are necessary for proton beam commissioning and periodic quality assurance (QA) purposes and are currently performed at our institution with a commercial scintillation detector (Lynx PT) with limited means for independent checks. The purpose of this work was to create an independent dosimetry system consisting of an in-house optical scanner and a BaFBrI:Eu2+ storage phosphor dosimeter by: (a) determining the optimal settings for the optical scanner, (b) measuring 2D proton spot profiles with the storage phosphors, and (c) comparing them to similar measurements using a commercial scintillation detector. METHODS: An in-house 2D laboratory optical scanner was constructed and spatially calibrated for accurate 2D photostimulated luminescence (PSL) dosimetry. Square 5 × 5 cm2 BaFBrI:Eu2+ dosimeter samples were uniformly irradiated with line scans performed to determine the physical and electronic scanner settings resulting in the highest signal-to-noise ratios (SNR) at a sub-millimeter spatial resolution. The resultant spatial resolution of the scanner was then quantitatively assessed by measuring (a) line pairs on a standard X-ray lead bar phantom and (b) modulation transfer functions. Following this, 2D proton spot profiles from a Mevion S250i Hyperscan proton unit were obtained at 1, 10, 20, 30, 40, and 50 monitor unit (MU) settings at maximum energy (E0  = 227.1 MeV) and compared to baseline profiles from a commercial scintillation detector, where 1 MU is calibrated to deliver 1 Gy absolute proton dose-to-water under reference conditions, that is, 41 × 41 proton spots uniformly spaced by 0.25 cm within a 10 × 10 cm2 square field size at maximum energy (227.1 MeV) in water at depth of 5 cm at isocenter. The dosimetric system's sensitivities to (a) ±1 mm positional shifts and (b) ±0.3 mm beam lateral spread changes were quantitatively evaluated through a Gaussian fitting of the crossline and inline plots of the respective artificially shifted beam profiles. RESULTS: The physical scanner settings of (a) Δτ = 27 ms time interval between data samples, (b) vx  = 1.235 cm/s scanning speed, (c) 1% laser transmission (0.02 mW power) and (d) (Δx, Δy) = (0.33, 0.50 mm) pixel sizes with electronic settings of (a) 300 microseconds time constant, (b) normal dynamic reserve, (c) 24 dB/oct low pass filter slope, and (d) 160 Hz chopping frequency resulted in the highest SNR while maintaining sub-millimeter spatial resolution. The BaFBr0.85 I0.15 :Eu2+ storage phosphor dosimeters were linear from 1 to 50 MU and their profiles did not saturate up to 150 MU. The scanner was able to detect lateral displacements of ±1 mm in both the crossline and inline directions and ±0.3 mm beam spread changes that were artificially introduced by varying the incident proton energy. Specific to our proton unit, proton energy changes of ±1 MeV can also be detected indirectly via beam spread measurements. CONCLUSION: Our combined dosimetric system including an in-house laboratory optical scanner and reusable BaFBr0.85 I0.15 :Eu2+ storage phosphors demonstrated a sufficient spatial resolution and dosimetric accuracy to support its use as an independent proton spot measurement dosimeter system. Its wide dynamic range allows for other versatile applications such as proton halo measurements.


Assuntos
Terapia com Prótons , Prótons , Imagens de Fantasmas , Dosímetros de Radiação , Radiometria
3.
Med Phys ; 48(4): 1941-1955, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33525050

RESUMO

PURPOSE: To investigate the feasibility of using the high Zeff storage phosphor material BaFBrI:Eu2+ in conjunction with the low Zeff storage phosphor material KCl:Eu2+ for simultaneous proton dose and linear energy transfer (LET) measurements by (a) measuring the fundamental optical and dosimetric properties of BaFBrI:Eu2+ , (b) evaluating its compatibility in being readout simultaneously with KCl:Eu2+ dosimeters, and (c) modeling and validating its LET dependence under elevated proton LET irradiation. METHODS: A commercial BaFBrI:Eu2+ storage phosphor detector (Model ST-VI, Fujifilm) was characterized with energy dispersive x-ray spectroscopy (EDS) analysis to obtain its elemental composition. The dosimeters were irradiated using both a Mevion S250 proton therapy unit (at the center of a spread-out Bragg peak, SOBP) and a Varian Clinac iX linear accelerator with the latter being a low LET irradiation. The photostimulated luminescence (PSL) emission spectra, excitation spectra, and luminescent lifetimes of the detector were measured after proton and photon irradiations. Dosimetric properties including dose linearity, dose rate dependence, radiation hardness, temporal, and readout stabilities were studied using a laboratory optical reader after proton irradiations. In addition, its proton energy dependence was analytically modeled and experimentally validated by irradiating the detectors at various depths within the SOBP (Range: 15.0 g/cm2 , Modulation: 10.0 g/cm2 ). RESULTS: The active detector composition for the high Zeff storage phosphor detector was found to be BaFBr0.85 I0.15 :Eu2+ . The BaFBr0.85 I0.15 :Eu2+ material's excitation and emission spectra were in agreement under proton and photon irradiations, with peaks of 586 ± 1 nm and 400 ± 1 nm, respectively, with a full width at half maximum (FWHM) of 119 ± 3 nm and 30 ± 2 nm, respectively. As dosimeter response under photon irradiation is generally believed to be free from LET effect, these results suggest LET independence of charge storage center types resulted from ionizing radiations. There is sufficient spectral overlaps with KCl:Eu2+ dosimeters allowing both dosimeters to be readout under equivalent readout conditions, that is, 594 nm stimulation and 420 nm detection wavelengths. Its PSL characteristic lifetime was found to be less than 5 microseconds which would make it suitable for fast 2D readout post irradiation. Its 420 nm emission band intensity was found to be linear up to 10 Gy absolute proton dose under the same irradiation conditions, dose rate independent, stable in time and under multiple readouts, and with high radiation hardness under cumulative proton dose histories up to 200 Gy as tested in this study. BaFBr0.85 I0.15 :Eu2+ showed significant proton energy-dependent dose under-response in regions of high LET which could be modeled by stopping power ratio calculations with an accuracy of 3% in low LET regions and a distance-to-agreement (DTA) of 1 mm in high LET regions (>5 keV/µm). CONCLUSION: We have proven the feasibility of dual-storage phosphor proton dosimetry for simultaneous proton dose and LET measurements. BaFBr0.85 I0.15 :Eu2+ has shown equally excellent dosimetry performance as its low Zeff complement KCl:Eu2+ with distinctive LET dependence merely as a result of its higher Zeff . These promising results pave the way for future studies involving simultaneous proton dose and LET measurements using this novel approach.


Assuntos
Transferência Linear de Energia , Terapia com Prótons , Luminescência , Prótons , Radiometria
4.
Med Phys ; 47(10): 5287-5300, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32750155

RESUMO

PURPOSE: To (a) characterize the fundamental optical and dosimetric properties of the storage phosphor europium-doped potassium chloride for quantitative proton dosimetry, and (b) investigate if its dose radiation response can be described by an analytic radiation transport model. METHODS: Cylindrical KCl:Eu2+ dosimeters with dimensions of 6 mm diameter and 1 mm thickness were fabricated in-house. The dosimeters were irradiated using both a Mevion S250 passive scattering proton therapy system and a Varian Clinac iX linear accelerator. Photostimulated luminescence (PSL) emission spectra, excitation spectra, and luminescence lifetimes were measured for both proton and photon irradiations. Dosimetric properties including radiation hardness, dose linearity, signal stabilization, dose rate sensitivity, and energy dependence were studied using a laboratory optical reader after irradiations. The dosimeters were modeled using physical quantities including mass stopping powers in the storage phosphor and water for a given proton beam, and mass energy absorption coefficients and massing stopping powers in detector and water for a given photon beam. RESULTS: KCl:Eu2+ exhibited optical emission and stimulation peaks at 421 and 560 nm, respectively, for both proton and photon irradiations, enabling postirradiation readouts using a visible light source while detecting the PSL using a photomultiplier tube. KCl:Eu2+ showed a linear response from 0 to 8 Gy absorbed dose-to-water, a large dynamic range up to 60 Gy, dose-rate independence measured from 83 to 500 MU/min, and a PSL lifetime of <5 ms that is sufficiently short for supporting rapid scanning in a two-dimensional geometry. KCl:Eu2+ was highly reusable with only a slight signal decrease of ~3% at accumulated doses over 100 Gy, which could be managed by a periodic recalibration. The detected PSL signal strength of the dosimeter in the proton field had been calculated accurately to a maximum discrepancy of 2% using known physical quantities along with its prior signal strength as measured in a photon field at the same dose-to-water. This discrepancy might be attributed to an under-response due to linear energy transfer (LET) effect. However, comparisons of depth-dose measurements in a spread-out Bragg peak (SOBP) field with a parallel-plate ionization chamber showed no clear evidence of LET effects. Furthermore, range measurements agreed with ionization chamber measurements to within 1 mm. CONCLUSIONS: KCl:Eu2+ showed linear response over a large dynamic range for proton irradiations and reliably reproduced SOBP measurements as measured by ionization chambers. Its relatively low atomic number of 18 and near LET independence make it suited for quantitative proton dosimetry. In addition, its high radiation hardness means that it can be reused numerous times. Any potential measurement artifacts encountered in complex irradiation conditions should be able to be corrected for using known physical quantities.


Assuntos
Európio , Terapia com Prótons , Cloreto de Potássio , Prótons , Radiometria
5.
Phys Med ; 73: 8-12, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32279048

RESUMO

Magnetic Resonance Imaging (MRI) scanners are widely used for 3D gel dosimeters readout. However, limited access to MRI scanners is a challenge in MRI-based gel dosimetry. Recent clinical implementation of MRI-guided radiation therapy machines provides potential opportunities for onboard gel dosimetry using its MRI subsystem. The objective of this study was to investigate the feasibility of gel dosimetry using ViewRay's onboard 0.35 T MRI scanner. A BANG® polymer gel dosimeter was irradiated by three beams of 3 × 3 cm2 field size. The T2 relaxation rate (R2) of the irradiated gel was measured using a Philips 1.5 T Ingenia MRI and a ViewRay 0.35 T onboard MRI and spin-echo pulse sequences. The number of signal averages (NSA) was set to 16 for the ViewRay acquisitions and one for the Philips 1.5 T MRI to achieve similar signal-to-noise ratios. The in-plane spatial resolution was 1.5 × 1.5 mm2 and the slice thickness was 5 mm. The relative dose uncertainty was obtained using R2 versus dose curves to compare the performance of dosimetry using the two different MRIs and field strengths. The dose uncertainty decreased from 12% at 2 Gy to 3.5% at 7.5 Gy at 1.5 T. The dose uncertainty decreased from 13% at 2 Gy to 4% at 7.5 Gy with NSA = 16 and 3 × 3 mm2 pixel size, and from 10.5% at 2 Gy to 3.2% at 7.5 Gy with NSA = 16 and denoised R2 maps (1.5 × 1.5 mm2 pixel size) at 0.35 T. The mean of dose resolution was 0.4 Gy at 1.5 T while the mean of dose resolution was 0.8 Gy and 0.64 Gy at 0.35 T by downsampling and denoising the R2 map, respectively. Therefore, comparable dose uncertainty was achievable using the ViewRay's onboard 0.35 T and Philips 1.5 T MRI scanners. 3D gel dosimetry using onboard low-field MRI scanner provides ViewRay users a 3D high resolution dosimetry option besides film and ionization chamber.


Assuntos
Imageamento por Ressonância Magnética , Polímeros/química , Doses de Radiação , Radioterapia Guiada por Imagem/instrumentação , Estudos de Viabilidade , Géis , Humanos , Radiometria , Dosagem Radioterapêutica