Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 381
Filtrar
3.
J Am Coll Cardiol ; 38(6): 1748-56, 2001 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-11704391

RESUMO

OBJECTIVES: We hypothesized that wall motion velocity during pre-ejection is proportional to the regional content of viable myocardium after reperfusion for acute myocardial infarction (AMI). BACKGROUND: Pre-ejection wall motion consists of short and fast inward and outward movement towards and away from the center of the left ventricle (LV) and is altered during regional ischemia. This short-lived event can be accurately quantified by Doppler myocardial imaging (DMI). METHODS: Fourteen open-chest pigs underwent 60 to 120 min of left anterior descending coronary artery occlusion followed by 30 min of reperfusion. The DMI data were collected using a phased-array intracardiac catheter (LV cavity) from ischemic and nonischemic myocardium encompassed within a plane passing through two epicardial bead markers. Peak tissue velocities during isovolumic contraction (IVC) (peak positive and peak negative), ejection (S) and early filling (E) were measured. The cardiac specimen was sliced through the epicardial markers in a plane approximating the ultrasound imaging plane. The transmural extent of necrosis (TEN) (%) was measured by triphenyltetrazolium chloride staining. RESULTS: During ischemia, positive IVC velocity was zero in ischemic walls with TEN >20%. At reperfusion, positive IVC velocity correlated better with TEN (r = -0.94, p < 0.0001) than it did S (r = -0.70, p < 0.01) and E (r = -0.81, p < 0.01). Differential IVC (the difference between peak positive and peak negative velocity) highly correlated with TEN, during ischemia (r = -0.78, p < 0.001) and during reperfusion (r = -0.93, p < 0.0001). CONCLUSIONS: Pre-ejection tissue velocity, as measured by intracardiac ultrasound, allows rapid estimation of the transmural extent of viable myocardium after reperfusion for AMI.


Assuntos
Infarto do Miocárdio/fisiopatologia , Animais , Circulação Coronária/fisiologia , Ecocardiografia Doppler , Contração Miocárdica/fisiologia , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/patologia , Isquemia Miocárdica/fisiopatologia , Reperfusão Miocárdica , Miocárdio/patologia , Necrose , Fluxo Sanguíneo Regional/fisiologia , Análise de Regressão , Volume Sistólico , Suínos
4.
Am J Med ; 111(6): 433-8, 2001 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-11690567

RESUMO

PURPOSE: To determine the incidence of thromboembolic complications after cardioversion in patients with atrial flutter. SUBJECTS AND METHODS: We reviewed 615 electrical cardioversions performed electively in 493 patients with atrial flutter. Embolic complications were evaluated during the 30 days after cardioversion. Follow-up data were obtained by follow-up visits and by contacting the treating physician. RESULTS: Anticoagulants had been administered in 415 cardioversions (67%). Cardioversion was successful in 570 procedures (93%). Three embolic events (in 3 patients) occurred in the 30 days after 550 successful cardioversions with completed follow-up (0.6% of successful procedures; 95% confidence interval, 0.1% to 1.6%). Two of the 3 patients had not been anticoagulated, whereas the third patient had subtherapeutic oral anticoagulation. No embolic event occurred in procedures performed with adequate anticoagulation. The incidence of embolism in patients regardless of subtherapeutic anticoagulation was 1% (3 of 303 successful cardioversions). CONCLUSIONS: We observed a low (0.6%) incidence of postcardioversion thromboembolic complications in patients with atrial flutter. Embolic events did not occur in patients with adequate anticoagulation.


Assuntos
Flutter Atrial/terapia , Cardioversão Elétrica/efeitos adversos , Tromboembolia/etiologia , Tromboembolia/fisiopatologia , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/administração & dosagem , Anticoagulantes/uso terapêutico , Flutter Atrial/diagnóstico por imagem , Flutter Atrial/fisiopatologia , Feminino , Seguimentos , Heparina/uso terapêutico , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Retrospectivos , Fatores de Risco , Tromboembolia/diagnóstico por imagem , Ultrassonografia
5.
J Am Soc Echocardiogr ; 14(10): 978-86, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11593202

RESUMO

Systolic and especially diastolic Doppler time intervals may be early markers of myocardial ischemia inducible by dobutamine-atropine stress echocardiography (DASE). We postulated that the Doppler myocardial performance index (MPI) may help differentiate ischemic from nonischemic responses. Hemodynamic and Doppler echocardiography variables were measured prospectively at every stress level of DASE in 32 patients (mean age 67 +/- 13 years). Adequate recordings were obtained in 27 patients; 13 had an ischemic response (group I) and 14 a nonischemic response (group II). Heart rate differed between groups at baseline. At equivalent peak stress, left ventricular wall motion score index was significantly greater and ejection fraction lower in group I patients. Of the Doppler variables, only the MPI consistently differed between groups, irrespective of the number of stress levels compared. The Doppler MPI may be a useful adjunct to wall motion analysis in the detection of myocardial ischemia during DASE.


Assuntos
Pressão Sanguínea , Ecocardiografia Doppler , Teste de Esforço/métodos , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/fisiopatologia , Agonistas Adrenérgicos beta , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Antiarrítmicos , Atropina , Diástole , Dobutamina , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Projetos de Pesquisa , Sístole
6.
J Am Soc Echocardiogr ; 14(8): 757-63, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11490323

RESUMO

To assess the association between color M-mode flow propagation velocity and the early diastolic mitral annular velocity (E(m)) obtained with tissue Doppler echocardiography and to assess the prognostic implications of the indexes, echocardiography was performed on days 1 and 5, and 1 and 3 months after a first myocardial infarction in 67 consecutive patients. Flow propagation velocity correlated well with E(m) (r = 0.72, P <.0001). The ratio of peak E-wave velocity (E) to flow propagation velocity also correlated well with E/E(m) (r = 0.87, P <.0001). The positive predictive value of E/FPV > or =1.5 to identify patients with Killip class > or =II was 90%, and the negative predictive value 92%. The corresponding values for E/E(m) > or =10 were 70% and 90%. Cox proportional hazards analysis identified E/flow propagation velocity > or =1.5 (relative risk, 12.4 [95% confidence interval, 4.1-37.3]), E/E(m) > or =10 (relative risk, 11.5 [95% confidence interval, 3.8-34.7]), and Killip class > or =II (relative risk, 7.8 [95% confidence interval, 1.6-40.4]) to be predictors of the composite end point of cardiac death and readmission because of heart failure. Thus flow propagation velocity and E(m) are closely related after myocardial infarction and appear to have similar prognostic information.


Assuntos
Ecocardiografia Doppler em Cores , Ecocardiografia Doppler de Pulso , Insuficiência Cardíaca/diagnóstico por imagem , Infarto do Miocárdio/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Feminino , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/mortalidade , Readmissão do Paciente , Valor Preditivo dos Testes , Prognóstico
7.
J Am Soc Echocardiogr ; 14(8): 789-97, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11490327

RESUMO

Conventional gray-scale myocardial contrast echocardiography cannot distinguish perfused but attenuated from nonperfused myocardium because both may appear similar at low image intensity. We hypothesized that with radiofrequency spectral analysis of attenuated ultrasound signals, the harmonic-to-fundamental frequency ratio of the peak power spectrum (HFR(P)) could determine the presence of contrast microbubbles. We measured frequency responses of Optison microbubbles at defined degrees of ultrasound signal attenuation with different formulations of silicone (55D, 80A, and 3M); gray-scale intensities of Optison plus water compared with degassed water were analyzed at different attenuation settings (-25, -32, and -44 dB, respectively). HFR(P) values of Optison plus water were significantly higher than reference values of degassed water at each attenuation setting (55D, -14 +/- 2 dB versus -30 +/- 2 dB, P <.001; 80A, -19 +/- 2 dB versus -30 +/- 3 dB, P <.01; 3M, -22 +/- 2 dB versus -30 +/- 3 dB, P <.05), even though conventional videodensitometric analysis could not distinguish them. HFR(P) analysis objectively detects microbubbles in clinically relevant conditions of attenuation.


Assuntos
Meios de Contraste , Ultrassom , Ecocardiografia , Processamento de Imagem Assistida por Computador , Técnicas In Vitro , Microesferas , Silicones , Análise Espectral
8.
Am J Med ; 111(2): 96-102, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11498061

RESUMO

PURPOSE: We sought to determine the importance of a third heart sound (S(3)) and its relation to hemodynamic and valvular dysfunction. SUBJECTS AND METHODS: We prospectively enrolled 580 patients who had isolated valvular regurgitation (mitral, n = 299; aortic, n = 121) or primary left ventricular dysfunction with or without functional mitral regurgitation (n = 160). We analyzed the associations between the clinical finding of an audible S(3) (as noted in routine clinical practice by internal medicine physicians) and hemodynamic alterations measured by comprehensive quantitative Doppler echocardiography. RESULTS: S(3) was more prevalent in patients with primary left ventricular dysfunction (46%, n = 73) than in organic mitral (16%, n = 47) or aortic (12%, n = 14) regurgitation (P <0.001). Patients with an S(3) were more likely to have class III-IV symptoms (55% [74 of 137] vs. 18% [80 of 443] of those without an S(3), P <0.001) and had a higher mean [+/- SD] pulmonary pressure (55 +/- 15 vs. 41 +/- 11 mm Hg, P <0.001). An S(3) was also related to a higher early filling velocity due to a greater filling volume, restrictive filling, or both. An S(3) was a marker of severe regurgitation (regurgitant fraction > or =40%) in patients with primary left ventricular dysfunction (odds ratio [OR] = 2.4; 95% confidence interval [CI]: 1.1 to 5.5), mitral regurgitation (OR = 17; 95% CI: 5.8 to 52), and aortic regurgitation (OR = 7.1; 95% CI: 1.8-28). An S(3) was also associated with restrictive filling in primary left ventricular dysfunction (OR = 3.0; 95% CI, 1.6 to 5.9), marked dilatation in mitral regurgitation (OR = 20; 95% CI: 6.8 to 58), and an ejection fraction (<50%) in aortic regurgitation (OR = 19; 95% CI: 6.0 to 62). CONCLUSION: An audible S(3) is an important clinical finding, indicating severe hemodynamic alterations, and should lead to a comprehensive assessment and consideration of vigorous medical or surgical treatment.


Assuntos
Insuficiência da Valva Aórtica/fisiopatologia , Ecocardiografia Doppler , Sopros Cardíacos/fisiopatologia , Insuficiência da Valva Mitral/fisiopatologia , Disfunção Ventricular Esquerda/fisiopatologia , Idoso , Insuficiência da Valva Aórtica/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Diagnóstico Diferencial , Diástole , Feminino , Sopros Cardíacos/diagnóstico por imagem , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/diagnóstico por imagem , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Pressão Propulsora Pulmonar , Volume Sistólico , Sístole , Disfunção Ventricular Esquerda/diagnóstico por imagem
9.
Circulation ; 104(9): 976-8, 2001 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-11524387

RESUMO

BACKGROUND: The early diastolic velocity of the mitral annulus (E') is reduced in patients with diastolic dysfunction and increased filling pressures. Because transmitral inflow early velocity (E) increases progressively with higher filling pressures, E/E' has been shown to have a strong positive relationship with pulmonary capillary wedge pressure (PCWP) and left ventricular end-diastolic pressure. However, previous studies have primarily involved patients without a pericardial abnormality. In constrictive pericarditis (CP), E' is not reduced, despite increased filling pressures. This study evaluated the relationship between E/E' and PCWP in patients with CP. METHODS AND RESULTS: We studied 10 patients (8 men; mean age, 64+/-7 years) with surgically confirmed CP. Doppler echocardiography was performed to measure early and late diastolic transmitral flow velocities. Tissue Doppler echocardiography was performed to measure E'. PCWP was measured with right heart catheterization. All patients were in sinus rhythm. Mean E and E' were 91+/-15 cm/s and 11+/-4 cm/s, respectively. Mean PCWP was 25+/-6 mm Hg. E' was positively correlated with PCWP (r=0.69, P=0.027). There was a significant inverse correlation between E/E' and PCWP (r=-0.74, P=0.014). Despite high left ventricular filling pressures, E/E' (mean, 9+/-4) was <15 in all but 1 patient. CONCLUSIONS: Paradoxical to the positive correlation between E/E' and PCWP in patients with myocardial disease, an inverse relationship was found in patients with CP.


Assuntos
Valva Mitral/fisiopatologia , Pericardite Constritiva/fisiopatologia , Pressão Propulsora Pulmonar , Idoso , Velocidade do Fluxo Sanguíneo , Ecocardiografia Doppler , Feminino , Ventrículos do Coração/fisiopatologia , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Pericardite Constritiva/patologia
10.
J Am Coll Cardiol ; 38(3): 827-34, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11527641

RESUMO

OBJECTIVES: The aim of this study was to examine the association between atherosclerosis risk factors, aortic atherosclerosis and aortic valve abnormalities in the general population. BACKGROUND: Clinical and experimental studies suggest that aortic valve sclerosis (AVS) is a manifestation of the atherosclerotic process. METHODS: Three hundred eighty-one subjects, a sample of the Olmsted County (Minnesota) population, were examined by transthoracic and transesophageal echocardiography. The presence of AVS (thickened valve leaflets), elevated transaortic flow velocities and aortic regurgitation (AR) was determined. The associations between atherosclerosis risk factors, aortic atherosclerosis (imaged by transesophageal echocardiography) and aortic valve abnormalities were examined. RESULTS: Age, male gender, body mass index (odds ratio [OR]: 1.07 per kg/m(2); 95% confidence interval [CI]: 1.02 to 1.12), antihypertensive treatment (OR: 1.93; CI: 1.12 to 3.32) and plasma homocysteine levels (OR: 1.89 per twofold increase; CI: 0.99 to 3.61) were independently associated with an increased risk of AVS. Age, body mass index and pulse pressure (OR: 1.21 per 10 mm Hg; CI: 1.00 to 1.46) were associated with elevated (upper quintile) transaortic velocities, whereas only age was independently associated with AR. Sinotubular junction sclerosis (p = 0.001) and atherosclerosis of the ascending aorta (p = 0.03) were independently associated with AVS and elevated transaortic velocities, respectively. CONCLUSIONS: Atherosclerosis risk factors and proximal aortic atherosclerosis are independently associated with aortic valve abnormalities in the general population. These observations suggest that AVS is an atherosclerosis-like process involving the aortic valve.


Assuntos
Doenças da Aorta/patologia , Valva Aórtica/patologia , Arteriosclerose/patologia , Cardiomiopatias/patologia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Doenças da Aorta/epidemiologia , Arteriosclerose/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco
11.
J Ultrasound Med ; 20(7): 767-74, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11444736

RESUMO

OBJECTIVE: To assess the accuracy of left ventricular cavity shape reproduction from 8 spatially related, apical two-dimensional ultrasonographic images. METHODS: We scanned 6 dog heart specimens. Left ventricular cavity casts were reconstructed from 48-tomogram (high-density), 8-tomogram (octaplane), and 2-tomogram (low-density biplane) apical data sets. The 48-plane left ventricular cast served as the reference. Spatial shape resolution of 3 mm in radial distance from the rotational axis to the interpolated endocardium was used as the criterion of shape accuracy. RESULTS: The adjusted limits of agreement for the octaplane and biplane left ventricular casts were +/-2.31 and +/-6.84 mm, respectively. CONCLUSIONS: The three-dimensional left ventricular cavity shape can be accurately reproduced by using a low-data density apical octaplane echocardiographic examination.


Assuntos
Ecocardiografia , Ventrículos do Coração/anatomia & histologia , Imageamento Tridimensional , Função Ventricular Esquerda/fisiologia , Animais , Cães , Ecocardiografia Tridimensional , Ventrículos do Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador
13.
Circulation ; 103(24): 2882-4, 2001 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-11413074

RESUMO

BACKGROUND: Clinical applicability of conventional ultrasonographic systems using mechanical adapters for 3D echocardiographic imaging has been limited by long acquisition and processing times. We developed a rapid (6-s) acquisition technique that collects apical tomograms using a continuously internally rotating transthoracic transducer. This study was performed to examine the clinical feasibility of rapid-acquisition 3D echocardiography to estimate left ventricular end-diastolic and end-systolic volumes using electron-beam computed tomography as the reference standard. Methods and Results-We collected a series of 6 to 11 apical echocardiographic tomograms, depending on heart rate, in 11 patients. There was good correlation, low variability, and low bias between rapid 3D echocardiography and electron-beam computed tomography for measuring left ventricular end-diastolic volume (r=0.96; standard error of the estimate, 21.34 mL; bias, -4.93 mL) and left ventricular end-systolic volume (r=0.96; standard error of the estimate, 14.78 mL; bias, -6.97 mL). CONCLUSIONS: The rapid-acquisition 3D echocardiography extends the use of a multiplane, internally rotating handheld transducer so that it becomes a precise and clinically feasible tool for assessing left ventricular volumes and function. A rapid-image acquisition time of 6 s would allow repeated image collection during the course of a clinical echocardiographic examination. Additional work must address rapid and automated data processing.


Assuntos
Ecocardiografia Tridimensional/métodos , Cardiopatias/diagnóstico , Ventrículos do Coração/diagnóstico por imagem , Volume Sistólico , Adulto , Idoso , Ecocardiografia Tridimensional/instrumentação , Estudos de Viabilidade , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Fatores de Tempo , Tomografia , Tomografia Computadorizada por Raios X
14.
Mayo Clin Proc ; 76(5): 467-75, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11357793

RESUMO

OBJECTIVE: To evaluate the contribution of left atrial (LA) volume in predicting atrial fibrillation (AF). PATIENTS AND METHODS: In this retrospective cohort study, a random sample of 2200 adults was identified from all Olmsted County, Minnesota, residents who had undergone transthoracic echocardiographic assessment between 1990 and 1998 and were 65 years of age or older at the time of examination, were in sinus rhythm, and had no history of AF or other atrial arrhythmias, stroke, pacemaker, congenital heart disease, or valve surgery. The LA volume was measured off-line by using a biplane area-length method. Clinical characteristics and the outcome event of incident AF were determined by retrospective review of medical records. Echocardiographic data were retrieved from the laboratory database. From this cohort, 1655 patients in whom LA size data were available were followed from baseline echocardiogram until development of AF or death. The clinical and echocardiographic associations of AF, especially with respect to the role of LA volume in predicting AF, were determined. RESULTS: A total of 666 men and 989 women, mean +/- SD age of 75.2 +/- 7.3 years (range, 65-105 years), were followed for a mean +/- SD of 3.97 +/- 2.75 years (range, < 1.00-10.78 years); 189 (11.4%) developed AF. Cox model 5-year cumulative risks of AF by quartiles of LA volume were 3%, 12%, 15%, and 26%, respectively. With Cox proportional hazards multivariate models, logarithmic LA volume was an independent predictor of AF, incremental to clinical risk factors. After adjusting for age, sex, valvular heart disease, and hypertension, a 30% larger LA volume was associated with a 43% greater risk of AF, incremental to history of congestive heart failure (hazard ratio [HR], 1.887; 95% confidence interval [CI], 1.230-2.895; P = .004), myocardial infarction (HR, 1.751; 95% CI, 1.189-2.577; P = .004), and diabetes (HR, 1.734; 95% CI, 1.066-2.819; P = .03). Left atrial volume remained incremental to combined clinical risk factors and M-mode LA dimension for prediction of AF (P < .001). CONCLUSION: This study showed that a larger LA volume was associated with a higher risk of AF in older patients. The predictive value of LA volume was incremental to that of clinical risk profile and conventional M-mode LA dimension.


Assuntos
Fibrilação Atrial/etiologia , Volume Cardíaco , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico por imagem , Distribuição de Qui-Quadrado , Comorbidade , Ecocardiografia , Eletrocardiografia , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Risco
16.
J Am Soc Echocardiogr ; 14(5): 360-9, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11337681

RESUMO

Postsystolic compression (PSC) is a sensitive indicator of regional left ventricular ischemic diastolic dysfunction. Quantitative assessment of compression patterns by strain rate imaging could determine the presence and spatial extent of PSC for the detection and analysis of acute ischemic diastolic dysfunction. With the use of a segmental left ventricular model, we evaluated time to compression/expansion crossover (T-CEC) in standard apical views. Data at baseline and after acute left anterior descending coronary artery occlusion were collected from 18 open-chest pigs. We found significant mean prolongation of T-CEC, ranging from 43.9 +/- 48.6 ms to 110.8 +/- 73.8 ms, in all apical segments and in 2 midventricular (anterior and anteroseptal) segments. Analysis of variance demonstrated that the prolonged T-CEC is spatially consistent with perfusion defect. The temporal and spatial analysis of T-CEC with the use of strain rate imaging is a new noninvasive technique for identification and topographic quantitation of ischemic diastolic dysfunction expressed by PSC.


Assuntos
Ecocardiografia/métodos , Isquemia Miocárdica/fisiopatologia , Animais , Modelos Animais de Doenças , Variações Dependentes do Observador , Suínos , Disfunção Ventricular Esquerda/fisiopatologia
17.
Am J Cardiol ; 87(9): 1069-73, 2001 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-11348604

RESUMO

To assess the prognostic value of exercise echocardiography in patients with prior coronary artery bypass surgery, follow-up was obtained in 718 patients (591 men [82%] and 127 women [18%], aged 67 +/- 9 years) who underwent clinically indicated exercise echocardiography 5.7 +/- 4.7 years after coronary bypass surgery. Resting wall motion abnormalities were present in 479 patients (67%). New or worsening wall motion abnormalities developed with exercise in 366 patients (51%). During a median follow-up of 2.9 years, cardiac events included cardiac death in 36 patients and nonfatal myocardial infarction in 40 patients. The addition of the exercise echocardiographic variables, abnormal left ventricular end-systolic volume response and exercise ejection fraction to the clinical, resting echocardiographic and exercise electrocardiographic model provided incremental information in predicting cardiac events (chi-square 37 to chi-square 42, p = 0.02) and cardiac death (chi-square 38 to chi-square 43, p <0.02). Exercise echocardiography provides prognostic information in patients after coronary artery bypass surgery, incremental to clinical, rest echocardiographic, and exercise electrocardiographic variables.


Assuntos
Ponte de Artéria Coronária , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/fisiopatologia , Ecocardiografia , Teste de Esforço , Idoso , Distribuição de Qui-Quadrado , Doença das Coronárias/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Prognóstico , Modelos de Riscos Proporcionais , Fatores de Risco , Análise de Sobrevida
18.
Mayo Clin Proc ; 76(4): 364-8, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11322351

RESUMO

OBJECTIVE: To assess thromboembolic complications in cardioversions in patients with atrial fibrillation or flutter and a previous embolic event. PATIENTS AND METHODS: The study population consisted of 104 patients with previous embolic events who underwent 128 electrical cardioversions for termination of atrial fibrillation or flutter. The primary outcome measure was successful cardioversion. RESULTS: Anticoagulants were administered in 118 procedures (92%). Cardioversion was successful in 108 (84%) of the 128 procedures. Only 1 embolic event occurred within 30 days after cardioversion (incidence, 0.9% of successful procedures; 95 % confidence interval, 0.02%-5.3%). The single embolic event was a transient neurologic deficit occurring 22 days after cardioversion in a patient with previous atrial fibrillation. This patient had a sub-therapeutic level of anticoagulation. Transesophageal echocardiography revealed no spontaneous echo contrast or thrombi before the procedure. No thromboembolism was noted in patients who had therapeutic anticoagulation or in those with failed cardioversion. CONCLUSION: Patients with previous embolism are not at additional risk of thromboembolic complications after cardioversion if anticoagulation is adequate.


Assuntos
Fibrilação Atrial/terapia , Flutter Atrial/terapia , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/métodos , Tromboembolia/diagnóstico , Idoso , Anticoagulantes/administração & dosagem , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/mortalidade , Flutter Atrial/complicações , Flutter Atrial/diagnóstico por imagem , Flutter Atrial/mortalidade , Intervalos de Confiança , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Recidiva , Medição de Risco , Sensibilidade e Especificidade , Taxa de Sobrevida , Tromboembolia/complicações , Tromboembolia/epidemiologia , Resultado do Tratamento
19.
J Am Coll Cardiol ; 37(4): 1141-8, 2001 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-11263621

RESUMO

OBJECTIVES: We propose a new method to easily quantify asynchronous wall motion due to postsystolic shortening (PSS). We also studied the relationship of the spatial and temporal extent of PSS to the extent of myocardium at ischemic risk after variable duration of ischemia. BACKGROUND: Postsystolic shortening is a sensitive marker of asynchrony during ischemia. Current techniques for detection of asynchrony are either subjective, or invasive and time-consuming. Strain rate imaging (SRI) can noninvasively depict PSS as prolonged compression/expansion crossover. METHODS: Nineteen open-chest pigs were scanned from apical views, before and after left anterior descending coronary artery occlusion. Strain rates were derived offline from tissue Doppler velocity cineloops. The time from electrocardiographic R-wave to the occurrence of compression/expansion crossover (TCEC) was calculated. Prolonged TCEC during ischemia was identified using a standardized analysis and both spatial (% of left ventricle) and temporal extent were quantified. The extent of myocardium at risk was measured in seven animals from dye-stained specimens. RESULTS: Prolonged TCEC was found in all ischemic segments. There was a good correlation (r = 0.91; p < 0.001) and good agreement between the spatial distributions of prolonged TCEC and myocardium at risk. The extent of myocardium at risk was better approximated by TCEC measurement (36 +/- 7% vs. 39 +/- 8%, respectively; p = NS) than by wall motion analysis (47 +/- 17%, p < 0.05). The duration of occlusion did not prolong TCEC. CONCLUSIONS: Prolonged TCEC consistently occurs in ischemic myocardium and is apparently not affected by the duration of ischemia. Standardized analysis of TCEC in SRI closely quantifies the extent of ischemic myocardium. This new method may be a useful tool in other cardiac conditions associated with regional diastolic asynchrony.


Assuntos
Contração Miocárdica , Isquemia Miocárdica/diagnóstico por imagem , Animais , Eletrocardiografia , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Isquemia Miocárdica/fisiopatologia , Suínos , Fatores de Tempo , Ultrassonografia
20.
Gastrointest Endosc ; 53(4): 496-9, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11275895

RESUMO

BACKGROUND: EUS requires a significant capital outlay. The ability to perform high-resolution phased array scanning and Doppler interrogation by using a catheter that interfaces with a standard US console could increase the accessibility of EUS. Recently, an electronic phased-array US catheter was developed for intracardiac use. To date, this technology has not been applied to the GI tract. The aim of this study is to determine the feasibility and imaging characteristics of a new phased array scanning US catheter in the GI tract. METHODS: Swine were placed under general anesthesia. This study used a 100 cm, 10F, torquable catheter with 4-way tip deflection to greater than 90 degrees. The catheter tip houses a phased vector array transducer with variable frequency (5.5-10 MHz) and variable focal distance. It has pulsed/color and power Doppler capability. The probe was passed through a therapeutic flexible sigmoidoscope into the upper GI tract. Acoustic coupling was achieved via a condom filled with water or by gastric water infusion. Needle visualization experiments were performed with a second endoscope (also passed per oral) with a standard EUS-guided fine needle aspiration needle. RESULTS: Acoustic coupling was easily achieved. Resolution of the GI wall into characteristic layers (esophagus 5, stomach 7) was demonstrated. At 5.5 MHz, tissue resolution and Doppler imaging were excellent to greater than 10 cm from the transducer. A 22-gauge EUS-guided fine needle aspiration needle was easily visualized at depth greater than 4 cm. Flow in gastric, hepatic, and pancreatic parenchymal vessels approximately 1 mm diameter was visualized by using power and color Doppler. CONCLUSIONS: This 10F array US catheter is capable of high-resolution two-dimensional imaging of the gut wall as well as high-quality Doppler imaging. The Doppler capabilities of this equipment may have new GI applications.


Assuntos
Cateterismo/métodos , Endoscopia Gastrointestinal/métodos , Ultrassonografia Doppler em Cores/métodos , Animais , Biópsia por Agulha/métodos , Esôfago/diagnóstico por imagem , Estudos de Viabilidade , Fígado/irrigação sanguínea , Fígado/diagnóstico por imagem , Circulação Hepática , Sensibilidade e Especificidade , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA