Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
J Prosthodont ; 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38858223

RESUMO

PURPOSE: Denture fabrication has shifted from traditional heat-processed and auto-polymerizing materials to computer-aided design and computer-aided manufacturing (CAD-CAM) milled and printed materials. The monomer in traditional materials can induce an allergic reaction in some patients. With the rise in the edentulous population and increasing demand for the fabrication of dentures, these newer materials should be studied for monomer leaching. The purpose of this study was to evaluate the ratio of residual monomer in materials being used for denture bases: CAD-milled polymethylmethacrylate (PMMA), printed denture base resin, heat-processed PMMA, and auto-polymerizing PMMA comparatively. MATERIALS AND METHODS: Milled, printed, heat-activated, and auto-polymerizing denture base specimens (n = 3 for each group, each test run three times) were fabricated according to manufacturer recommendations. Specimens were first immersed in deuterated chloroform (CDCl3), a deuterated organic solvent, to evaluate monomer leaching and to observe physical properties of the materials. NMR spectroscopy was used to evaluate the dissolution of materials and residual monomer to crosslinked polymer ratios at 1, 4, and 9 days. A second group of specimens was then immersed in deuterium oxide (D2O) to evaluate if the residual monomers would leach out of the system. The solution was then analyzed using nuclear magnetic resonance (NMR) spectroscopy for 1 month. The deuterated forms of chloroform (CDCl3) and water (D2O) were used to enable sample characterization by NMR. RESULTS: While the heat-processed, auto-polymerizing, and milled specimens possessed residual monomers, no significant monomer leaching was noted in the printed specimen, while immersed in CDCl3. Similarly, the printed specimen was most resistant to dissolution, as compared to the rest; dissolution of the specimen is indicative of little to no cross-linking. No detectable dissolution of monomer was seen when all specimens were immersed in D2O for up to 1 month. CONCLUSIONS: Residual monomers were not found in the printed denture material in this study in either CDCl3 or D2O, whereas CAD-milled and traditionally processed denture bases still have residual monomers within their respective systems when immersed in organic solvent. None of the specimens tested leached monomers into D2O.

2.
J Esthet Restor Dent ; 36(3): 503-510, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37994681

RESUMO

OBJECTIVE: Measure and compare the mechanical properties, translucency, and fluoride-releasing capabilities of EQUIA Forte HT against Fuji IX GP and ChemFil Rock. MATERIALS AND METHODS: Ten specimens of each material were fabricated for compressive strength (CS), flexural strength (FS), and surface hardness analysis at 24 h and 7 days. The L*a*b* values were measured against a black-and-white background using a spectrophotometer to analyze the translucency parameter (TP). Fluoride release was recorded after 2 months of immersion in distilled water. The mean data was analyzed by 1- and 2-way ANOVA (α = 0.5). RESULTS: EQUIA Forte HT showed higher CS, surface hardness, and FS values (p < 0.05) compared with Fuji IX GIC, while no significant difference was found in FS values between EQUIA Forte HT and Chemfil Rock (p > 0.05). The EQUIA Forte HT exhibited significantly higher translucency in comparison to both ChemFil Rock (p < 0.001) and Fuji IX GICs (p < 0.05). An increase (p > 0.05) of fluoride release was observed for EQUIA Forte HT. CONCLUSION: The EQUIA Forte HT Glass-ionomer cements (GIC) offers enhanced translucency, improved strength, and enhanced fluoride-releasing properties compared to the traditionally used Fuji IX GIC and ChemFil Rock GICs. This material might have a wide range of clinical applications due to its improved strength and optical properties. CLINICAL SIGNIFICANCE: Glass-ionomer dental restorative materials possess unique advantageous characteristics. However, its poor mechanical and optical properties have typically limited its clinical applications. Efforts to improve these properties have resulted in enhanced GICs. EQUIA Forte HT GIC offers enhanced mechanical and optical properties with potential applications in posterior and anterior restorative procedures.


Assuntos
Silicatos de Alumínio , Materiais Dentários , Fluoretos , Cimentos de Ionômeros de Vidro , Força Compressiva , Dureza , Teste de Materiais
3.
J Prosthodont ; 32(S1): 29-37, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35674217

RESUMO

PURPOSE: As the fabrication of computer-aided design (CAD) milled and 3D printed denture base resins with bonded denture teeth increase in popularity, there is a need for research comparing the shear bond stress of milled and printed denture base resins with bonded denture teeth to that of a conventional heat processed denture base. MATERIALS AND METHODS: Denture base resin specimens (n = 9) were fabricated according to manufacturers' instructions using a novel test design. Two milled (Ivobase CAD PMMA, Ivoclar Vivadent and Polident PMMA, Polident Dental) and two 3D printed (Denture Base LP Resin, Formlabs and Lucitone Digital Print, Dentsply Sirona) materials were used. Conventional heat processed polymethylmethacrylate was used as the control (Lucitone 199, Dentsply Sirona). Denture teeth (VITA Vitapan XL T44, #8, VITA Zahnfabrik) were bonded to their respective bases using denture tooth bonding agent (Ivobase CAD bonding system, Ivoclar). Specimens were aged in water for 600 hours at 37°C and loaded until failure in a Universal testing machine. Shear bond stress was calculated. All specimens were evaluated for mode of failure and select specimens under scanning electron microscope and vertical scanning interferometry. Data were analyzed with one-way ANOVA followed by Tukey test (IBM SPSS) and fracture analysis performed. RESULTS: Shear stress was highest for the heat processed control (mean = 180 N ±26.76) and Polident test groups (mean = 180 N ± 34.90). Milled specimens were not significantly different from the control (p = 0.076 for IvoBase CAD and 1.00 for Polident), while the printed groups were significantly different from the control (p = 0.012 for Formlabs Denture Base Resin and p = 0.00 for Carbon Lucitone Digital Print). Milled denture base resins performed similarly to heat processed denture base resin and better than 3D printed denture bases. CONCLUSION: For complete denture wearers, all resin materials used in this study may be clinically acceptable, as the sheer stress for all groups was higher than the reported maximum biting force of complete denture patients. However, for implant retained prostheses, the incorporation of additional retentive features should be considered when bonding denture teeth to printed bases. More research is needed to evaluate methods to increase the bond strength of denture teeth to printed denture base resins.


Assuntos
Colagem Dentária , Polimetil Metacrilato , Humanos , Idoso , Polimetil Metacrilato/química , Bases de Dentadura , Desenho Assistido por Computador , Teste de Materiais , Propriedades de Superfície
4.
Int J Oral Maxillofac Implants ; 36(5): 966-976, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34698723

RESUMO

PURPOSE: To evaluate the clinical, radiographic, and prosthetic outcomes of a single custom CAD/CAM abutment system on implants from four manufacturers, with a mean clinical service of 4 years in a retrospective, multicenter case series study. MATERIALS AND METHODS: Adult subjects (n = 142) previously restored with titanium or gold-shaded titanium nitride custom CAD/CAM abutments (Atlantis, Dentsply Sirona; n = 259) connected to implants from four different manufacturers (Dentsply Sirona Implants [AT], Biomet 3i [BM], Nobel Biocare [NB], Straumann [ST]), irrespective of implant-abutment interface, and replacing one or more teeth in any position were recalled for a single-visit examination by calibrated investigators at six university clinics. The primary outcomes evaluated included abutment success and survival; secondary outcomes included assessment of papillae fill, probing pocket depth (PD), bleeding on probing (BOP), marginal bone levels (MBLs), and patient-reported outcome measures (PROMs). RESULTS: Two-hundred fifty-five (98.5%) abutments supported cement-retained restorations, and four (1.5%) abutments supported screw-retained restorations. Forty-two patients had 64 AT implants (25%), 31 patients had 61 BM implants (24%), 26 patients had 50 NB implants (19%), and 43 patients had 84 ST implants (32%). The overall implant-CAD/CAM abutment success rate was 92.66% (95% CI: 88.78%, 95.53%) for all implants examined, and the survival rate was 98.84% (95% CI: 96.65%, 99.76%) for all implants evaluated. The Jemt papillae index demonstrated a minimum of at least 50% to complete fill of the interproximal papillae in 65.0% of sites. PDs had a median value of 3.0 mm, and BOP was present on 19% of abutment surfaces. Mean MBL changes from the time of placement to exam were -0.24 ± 0.99 mm (-4.9 to 2.3; P = .058) for mesial sites and -0.32 ± 0.96 mm (-4.9 to 2.1; P = .000) for distal sites. PROMs expressed 93% of patients reporting good to very good masticatory function, 97% of patients reporting being satisfied or very satisfied with their esthetic outcomes, and 94% of patients indicating that they were satisfied or very satisfied with their overall implant-restorative outcomes. CONCLUSION: This retrospective, multicenter clinical study of FDA 510k-approved titanium CAD/CAM abutments of a single manufacturer on multiple implant systems demonstrated high levels of success and survival as well as stable peri-implant tissue outcomes, reflected by overwhelmingly positive PROMs.


Assuntos
Projeto do Implante Dentário-Pivô , Implantes Dentários , Adulto , Estudos Transversais , Dente Suporte , Estética Dentária , Seguimentos , Humanos , Estudos Retrospectivos , Titânio , Zircônio
5.
J Prosthet Dent ; 126(4): 464-470, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32972712

RESUMO

Artifacts from metal restorations can make it challenging or impossible to accurately orient a digital dental cast to cone beam computed tomography (CBCT) scan data for virtual implant planning. A dual scan technique is described that uses an alginate impression with fiducial markers in a stock tray to create a digital dental cast that is precisely oriented to the scan in the same patient coordinate system for surgical guide design.


Assuntos
Implantes Dentários , Artefatos , Desenho Assistido por Computador , Tomografia Computadorizada de Feixe Cônico , Marcadores Fiduciais , Humanos , Imageamento Tridimensional
6.
J Prosthet Dent ; 125(3): 544.e1-544.e8, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33243474

RESUMO

STATEMENT OF PROBLEM: Information on the bond strength of milled polymethyl methacrylate interim restorations when relined with chairside reline materials is lacking. PURPOSE: The purpose of this in vitro study was to measure the shear bond strength of various combinations of 3 different chairside reline materials bonded to milled polymethyl methacrylate blocks with 3 different types of surface treatments. MATERIALS AND METHODS: Uniform blocks (10×10×22 mm) were milled from tooth-colored polymethyl methacrylate disks (Vivid PMMA; Pearson Dental Supply Co). The surface treatments tested were airborne-particle abrasion with 50-µm particle size aluminosilicate, application of acrylic resin monomer (Jet Liquid; Lang Dental Manufacturing Co) for 180 seconds, and airborne-particle abrasion with monomer application. The control groups were blocks with no surface treatment. The chairside reline materials tested were Jet acrylic resin (Jet Powder; Lang Dental Manufacturing Co), bis-acryl resin (Integrity; Dentsply Sirona), and flowable composite resin (Reveal; Bisco). All materials were applied through a Ø1.5×3-mm bonding ring. Ten specimens for each of the 12 groups were tested in a universal testing machine. Load was applied at a crosshead speed of 1 mm/min. Fracture surfaces were then analyzed for cohesive versus adhesive or mixed failure. Data were analyzed using 2-way ANOVA and Tukey-Kramer post hoc analysis (α=.05). RESULTS: The mean shear bond strength values ranged from 1.77 ±0.79 MPa to 28.49 ±5.75 MPa. ANOVA revealed that reline material (P<.05), surface treatment (P<.05), and their interactions (P<.05) significantly affected the shear bond strength among the experimental groups. The strongest combination was Jet acrylic resin applied on specimens treated with airborne-particle abrasion and monomer. All 3 failure modalities (adhesive, cohesive, and mixed modes) were observed. CONCLUSIONS: Of the materials tested, the most reliable material to bond to milled polymethyl methacrylate was Jet acrylic resin, and the bond strength values were increased substantially when the milled polymethyl methacrylate surface was airborne-particle abraded and monomer was applied.


Assuntos
Colagem Dentária , Polimetil Metacrilato , Óxido de Alumínio , Coroas , Análise do Estresse Dentário , Teste de Materiais , Cimentos de Resina , Resistência ao Cisalhamento , Propriedades de Superfície
7.
J Prosthet Dent ; 123(1): 45-49, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31079888

RESUMO

With the transition to digital workflows, moving from a digital platform to an articulator for laboratory procedures such as adding porcelain or luting titanium abutments is sometimes required. This report describes a technique to facilitate the transfer of jaw-relation records to a digital mounting template. Once digitally mounted, the casts can be printed with mounting plates attached to the temporomandibular joints in the appropriate orientation. They can then be placed in an articulator and used for layering porcelain or luting titanium abutments for screw-retained restorations.


Assuntos
Prótese Dentária Fixada por Implante , Fluxo de Trabalho , Desenho Assistido por Computador , Porcelana Dentária , Registro da Relação Maxilomandibular
8.
J Prosthet Dent ; 123(2): 257-263, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31227233

RESUMO

STATEMENT OF PROBLEM: Screw- and cement-based retention mechanisms are used to attach prostheses to dental implants; however, each approach can lead to clinical complications such as crown fracturing or peri-implantitis. A novel abutment and prosthesis retention system has been engineered to achieve the esthetics and retention force of cement-based fixation while maintaining the retrievability of screw-retained restorations. PURPOSE: The purpose of this pilot clinical study was to evaluate the effectiveness of this innovative retention system on posterior tooth restorations. MATERIAL AND METHODS: This clinical study, with up to 6 months of follow-up, included 8 participants with posterior osseointegrated implants who met the eligibility criteria to receive the abutment and shape memory sleeve. Radiographs were used to evaluate crown seating. Crown stability was measured using the Periotest, and occlusal analysis was performed using the Tekscan system and shimstock. Peri-implant health was evaluated by probing, and the plaque and gingival indices were recorded. In addition, patient-reported outcomes were recorded. RESULTS: Minimal differences were observed between baseline and endpoint assessment of the plaque and gingival indices, probing depth, and proximal and occlusal contacts. There were no patient-reported problems or complaints about discomfort. The overall peri-implant health remained unchanged from the baseline evaluations for all participants. Proximal contact around the restoration was present at the baseline and at the conclusion of the study for 7 of the participants. Occlusal contact was observed to be either light (5 participants) or holding (3 participants). In addition, visual inspection of retrieved crowns revealed clean surfaces free of macroparticle ingress, and bacterial accumulation at the coping-abutment interface was not detected. CONCLUSIONS: The safety and efficacy findings of this pilot clinical study suggest that this new shape memory alloy-based retention system may provide a suitable alternative for implant prosthodontics. The retention system allowed for easy prosthesis seating and retrieval.


Assuntos
Implantes Dentários para Um Único Dente , Implantes Dentários , Coroas , Dente Suporte , Retenção em Prótese Dentária , Prótese Dentária Fixada por Implante , Estética Dentária , Humanos
9.
J Prosthet Dent ; 124(2): 189-194, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31780105

RESUMO

STATEMENT OF PROBLEM: A nitinol sleeve that uses shape memory to rapidly unlock dental restorations from implant abutments has been developed to allow prosthesis removal for assessment and maintenance, and clinical treatment has been promising. However, objective studies that evaluate the wear and retention performance after short-term clinical use are lacking. PURPOSE: The purpose of this clinical study was to evaluate the wear and retention performance of a shape-memory abutment system after 6 months of clinical use. MATERIAL AND METHODS: Shape-memory alloy sleeves on posterior osseointegrated implants were retrieved after 6 months of clinical use. Scanning electron microscopy (SEM) was used to evaluate the surfaces of the retention sleeve's arms for wear. Uniaxial tensile testing was performed to measure the change in retention force after clinical use. Average retention values of the shape-memory abutment system were compared with previously reported in vitro retention values for definitive and interim cements used in titanium abutment and coping assemblies by using the Welch t test. RESULTS: No evidence of wear, fracture, or chipping was observed during SEM analysis on the shape-memory alloy sleeves. Additionally, no statistically significant difference was found in the median retention force for new (484.5 N) and clinically retrieved (476 N) nitinol sleeve specimens. Compared with a commercially available resin cement, the mean retention force for the control sleeves (480 ±37 N) was higher than that for the freshly cemented specimens (336.3 ±188 N). After 5000 cycles of compressive loads, the mean retention force for cement specimens decreased (209.4 ±83 N), while the clinical sleeves (476 ±50 N) remained unchanged. CONCLUSIONS: According to the results of this study, after 6 months of clinical use, the engaging surfaces of the shape-memory alloy sleeve did not show signs of wear, and the retention force was unchanged.


Assuntos
Implantes Dentários , Retenção em Prótese Dentária , Coroas , Dente Suporte , Cimentos Dentários , Análise do Estresse Dentário , Teste de Materiais , Cimentos de Resina , Ligas de Memória da Forma , Titânio
10.
J Prosthet Dent ; 122(2): 154-159, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31326149

RESUMO

STATEMENT OF PROBLEM: While glass ionomer cements have many unique properties and advantages, they still lack favorable mechanical properties. EQUIA Forte Fil is a newly developed glass ionomer cement (GIC) with improved mechanical strength. However, research and data on the physical properties of EQUIA Forte Fil are lacking. PURPOSE: The purpose of this in vitro study was to evaluate and compare the compressive, diametral tensile, and flexural strengths of EQUIA Forte Fil with Fuji IX GP and ChemFil Rock, restorative GICs commonly used in dentistry. Moreover, fluoride-releasing properties and surface hardness of the GICs were also assessed. MATERIAL AND METHODS: Ten disk-shaped specimens of each GIC (EQUIA Forte Fil, Fuji IX GP, and ChemFil Rock) were fabricated for mechanical and surface hardness tests by using polydimethylsiloxane (PDMS) molds. The specimens were tested after 24 hours and 7 days of immersion in distilled water at 37 °C. By using a mechanical testing machine, the compressive, diametral tensile, and flexural strengths of each GIC were measured. Fluoride-releasing properties were also evaluated (10 specimens per group). A microhardness tester was used to measure the surface hardness. The mean data were analyzed by using 1- and 2-way ANOVA (α=.05). RESULTS: EQUIA Forte Fil glass ionomer cements exhibited significantly greater (P<.05) flexural strength and surface hardness than Fuji IX GIC specimens. However, no significant difference (P>.05) was observed between the compressive and diametral tensile strength of EQUIA Forte Fil and Fuji IX GIC specimens. ChemFil Rock exhibited higher flexural strength than EQUIA Forte Fil (P>.05) but significantly lower compressive strength and microhardness (P<.05). Tested GICs matured after 1 week of immersion in distilled water, demonstrating a significant improvement in their mechanical properties. All the examined glass ionomers exhibited comparable initial fluoride-releasing properties, whereas EQUIA Forte Fil exhibited significantly higher (P<.05) amounts of fluoride release from the bulk of the material after 4 weeks. CONCLUSIONS: EQUIA Forte Fil is a promising restorative material with superior flexural strength and surface hardness compared with its predecessor, Fuji IX GP, or other commercially available glass ionomers.


Assuntos
Resinas Acrílicas , Cimentos de Ionômeros de Vidro , Força Compressiva , Teste de Materiais , Dióxido de Silício
11.
J Prosthet Dent ; 122(4): 348-350, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31307804

RESUMO

A digital method for capturing the acquired emergence profile from contoured implant interim restorations is described. Three separate digital scans were made by using an intraoral scanner and aligned by using a design software program capable of merging and alignment. The Boolean Difference function was then performed by using a free software program to obtain the emergence profile. This technique may be less time-consuming than analog methods and may be more accurate than existing digital methods.


Assuntos
Desenho Assistido por Computador , Técnica de Moldagem Odontológica , Software
12.
Oral Maxillofac Surg Clin North Am ; 31(3): 427-435, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31088711

RESUMO

A case report of a complete arch interim prosthesis executed using digital work flows and with guided implant surgery is presented. The novel shape-memory retained system used to retain the complete dental prosthesis is easily indexed onto the remaining dentition, thereby being both efficient and cost-effective in the short and long term.


Assuntos
Ligas , Dente Suporte , Ligas Dentárias , Implantes Dentários , Prótese Dentária Fixada por Implante , Humanos
13.
J Prosthet Dent ; 120(3): 447-453, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29703674

RESUMO

STATEMENT OF PROBLEM: Conventional approaches to adhesive bonding are not applicable to zirconia restorations. Recently, an etching solution, Zeta Etching Solution (ZES), has been introduced for etching the surface of zirconia. The effects of this etching solution on the bond strength and mechanical properties of zirconia are unknown. PURPOSE: The purpose of this in vitro study was to examine the effects of ZES on the bond strength and surface hardness of zirconia. MATERIAL AND METHODS: Two different types of partially stabilized tetragonal polycrystalline zirconia (TZP), Prettau zirconia (group P) and anterior Prettau (group AP), were evaluated with and without ZES etching. Each group was bonded to a zirconia substrate by using an adhesive resin cement. After 24 hours of storage in distilled water, the bond strength of the zirconia was analyzed. Vickers hardness was determined by using a microhardness tester. Scanning electron microscopy was used to analyze the surface microstructure and determine the mode of failure for each specimen. Results were analyzed and compared using 1-way ANOVA and Student t tests (α=.05). RESULTS: Scanning electron microscopy analysis showed that etching the surface of zirconia with ZES etching solution for 60 minutes changed the morphological characteristics and microstructure of zirconia, making the surface more irregular. The changes were more pronounced for AP specimens. Etching with ZES significantly increased the shear bond strength of zirconia (P<.05) in AP specimens. The bond strength of Prettau (P group) specimens after ZES etching did not increase significantly (P>.05). An adhesive failure mode was observed for P zirconia specimens, whereas zirconia specimens exhibited a cohesive mode of failure. No significant decrease (P>.05) was observed in the mean Vickers hardness numbers. CONCLUSIONS: Within the limitations of this in vitro study, it was concluded that etching in ZES for 30 minutes significantly enhanced the shear bond strength of highly translucent anterior Prettau (AP) zirconia restorations. Moreover, etching with ZES did not adversely affect the surface hardness of the zirconia specimens tested.


Assuntos
Cerâmica/uso terapêutico , Cimentos Dentários/uso terapêutico , Corrosão Dentária/métodos , Zircônio/uso terapêutico , Colagem Dentária , Restauração Dentária Permanente/métodos , Análise do Estresse Dentário , Dureza , Humanos , Microscopia Eletrônica de Varredura
14.
J Prosthet Dent ; 117(1): 8-12, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27622784

RESUMO

An innovative abutment system has recently been developed to address the well-known limitations of screw- and cement-retained implant restorations. This abutment system offers retrievability by replacing the cement layer with a precision-engineered nickel-titanium sleeve that switches between shapes that lock and unlock the prosthesis. The avoidance of cement precludes cement-related periimplant complications, while the elimination of occlusal screw access holes may enable predictable control over occlusion and improve the structural integrity of the prosthesis. By eliminating the need for cement clean up, occlusal access closure, and occlusal adjustments after insertion, the dentist is afforded more time to attend to the patient's general needs. This paper describes the design rationale for and clinical treatment using this novel abutment system.


Assuntos
Dente Suporte , Projeto do Implante Dentário-Pivô/métodos , Técnica de Moldagem Odontológica , Prótese Dentária Fixada por Implante/métodos , Humanos , Titânio
15.
J Calif Dent Assoc ; 36(11): 827-34, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19090070

RESUMO

This article reviews relevant clinical and radiographic information necessary to formulate an appropriate treatment plan for a patient requiring a single-tooth implant restoration. A step-by-step approach to collecting and analyzing this information a the pretreatment evaluation is presented. General considerations affecting implant treatment planning are discussed as are the parameters dictating ideal implant position and angulation.


Assuntos
Implantes Dentários para Um Único Dente , Planejamento de Assistência ao Paciente , Seleção de Pacientes , Implantação Dentária Endóssea , Oclusão Dentária , Gengiva/anatomia & histologia , Humanos , Arcada Parcialmente Edêntula/diagnóstico por imagem , Modelos Anatômicos , Modelos Dentários , Fotografia Dentária , Radiografia , Inquéritos e Questionários
16.
J Calif Dent Assoc ; 36(11): 837-48, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19090071

RESUMO

The purpose of this article is to delineate the sequential thought process involved in a multidisciplinary approach to treatment planning the single-implant restoration. The pertinent issues involving orthodontic, surgical and restorative processes will be discussed comprehensively, with an emphasis on how communication and coordination among specialists influence the manner in which treatment is rendered.


Assuntos
Implantação Dentária Endóssea/métodos , Implantes Dentários para Um Único Dente , Planejamento de Assistência ao Paciente , Equipe de Assistência ao Paciente , Aumento do Rebordo Alveolar , Comunicação , Procedimentos Clínicos , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante , Restauração Dentária Temporária , Relações Dentista-Paciente , Humanos , Ortodontia Corretiva , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA