Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Phys Eng Sci Med ; 46(4): 1779-1790, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37770779

RESUMO

The fetal heart rate (FHR) signal is used to assess the well-being of a fetus during labor. Manual interpretation of the FHR is subject to high inter- and intra-observer variability, leading to inconsistent clinical decision-making. The baseline of the FHR signal is crucial for its interpretation. An automated method for baseline determination may reduce interpretation variability. Based on this claim, we present the Auto-Regressed Double-Sided Improved Asymmetric Least Squares (ARDSIAsLS) method as a baseline calculation algorithm designed to imitate expert obstetrician baseline determination. As the FHR signal is prone to a high rate of missing data, a step of gap interpolation in a physiological manner was implemented in the algorithm. The baseline of the interpolated signal was determined using a weighted algorithm of two improved asymmetric least squares smoothing models and an improved symmetric least squares smoothing model. The algorithm was validated against a ground truth determined from annotations of six expert obstetricians. FHR baseline calculation performance of the ARDSIAsLS method yielded a mean absolute error of 2.54 bpm, a max absolute error of 5.22 bpm, and a root mean square error of 2.89 bpm. In a comparison between the algorithm and 11 previously published methods, the algorithm outperformed them all. Notably, the algorithm was non-inferior to expert annotations. Automating the baseline FHR determination process may help reduce practitioner discordance and aid decision-making in the delivery room.


Assuntos
Frequência Cardíaca Fetal , Trabalho de Parto , Gravidez , Feminino , Humanos , Frequência Cardíaca Fetal/fisiologia , Trabalho de Parto/fisiologia , Algoritmos , Feto/diagnóstico por imagem , Variações Dependentes do Observador
2.
Geroscience ; 45(4): 2589-2600, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37084120

RESUMO

Sinoatrial node (SAN) beating interval variability (BIV) and the average beating interval (BI) are regulated by a coupled-clock system, driven by Ca2+-calmodulin activated adenylyl cyclase, cAMP, and downstream PKA signaling. Reduced responsiveness of the BI and BIV to submaximal, [X]50, ß-adrenergic receptor (ß-AR) stimulation, and phosphodiesterase inhibition (PDEI) have been documented in aged SAN tissue, whereas the maximal responses, [X]max, do not differ by age. To determine whether age-associated dysfunction in cAMP signaling leads to altered responsiveness of BI and BIV, we measured cAMP levels and BI in adult (2-4 months n = 27) and aged (22-26 months n = 25) C57/BL6 mouse SAN tissue in control and in response to ß-AR or PDEI at X50 and [X]max. Both cAMP and average BI in adult SAN were reduced at X50, whereas cAMP and BI at Xmax did not differ by age. cAMP levels and average BI were correlated both within and between adult and aged SAN. BIV parameters in long- and short-range terms were correlated with cAMP levels for adult SAN. However, due to reduced cAMP within aged tissues at [X]50, these correlations were diminished in advanced age. Thus, cAMP level generated by the coupled clock mechanisms is tightly linked to average BI. Reduced cAMP level at X50 in aged SAN explains the reduced responsiveness of the BI and BIV to ß-AR stimulation and PDEI.


Assuntos
Marca-Passo Artificial , Transdução de Sinais , Animais , Camundongos , Nó Sinoatrial/fisiologia
3.
Geroscience ; 45(1): 209-219, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35790659

RESUMO

The prevalence of atria-related diseases increases exponentially with age and is associated with ATP supply-to-demand imbalances. Because evidence suggests that cAMP regulates ATP supply-to-demand, we explored aged-associated alterations in atrial ATP supply-to-demand balance and its correlation with cAMP levels. Right atrial tissues driven by spontaneous sinoatrial node impulses were isolated from aged (22-26 months) and adult (3-4 months) C57/BL6 mice. ATP demand increased by addition of isoproterenol or 3-Isobutyl-1-methylxanthine (IBMX) and decreased by application of carbachol. Each drug was administrated at the dose that led to a maximal change in beating rate (Xmax) and to 50% of that maximal change in adult tissue (X50). cAMP, NADH, NAD + NADH, and ATP levels were measured in the same tissue. The tight correlation between cAMP levels and the beating rate (i.e., the ATP demand) demonstrated in adult atria was altered in aged atria. cAMP levels were lower in aged compared to adult atrial tissue exposed to X50 of ISO or IBMX, but this difference narrowed at Xmax. Neither ATP nor NADH levels correlated with ATP demand in either adult or aged atria. Baseline NADH levels were lower in aged as compared to adult atria, but were restored by drug perturbations that increased cAMP levels. Reduction in Ca2+-activated adenylyl cyclase-induced decreased cAMP and prolongation of the spontaneous beat interval of adult atrial tissue to their baseline levels in aged tissue, brought energetics indices to baseline levels in aged tissue. Thus, cAMP regulates right atrial ATP supply-to-demand matching and can restore age-associated ATP supply-to-demand imbalance.


Assuntos
Fibrilação Atrial , Animais , Camundongos , 1-Metil-3-Isobutilxantina/farmacologia , Regulação para Baixo , NAD , AMP Cíclico , Trifosfato de Adenosina/farmacologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA