Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 130
Filtrar
1.
J Am Heart Assoc ; 13(10): e032620, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38761070

RESUMO

BACKGROUND: Immune checkpoint inhibitors (ICIs) have uncommon associations with cardiotoxicity, yet these cardiotoxic effects are associated with high mortality. An accurate assessment of risk for cardiotoxicity is essential for clinical decision-making, but data from randomized controlled trials often differ from real-world observational studies. METHODS AND RESULTS: A systematic search of PubMed, Embase, Cochrane Library, and Scopus was performed, including phase II and III randomized controlled trials (RCTs) and observational studies (OSs) reporting myocarditis or pericardial disease, myocardial infarction, or stroke with an immunotherapy. Odds ratios (ORs) were used to pool results between ICIs and other cancer therapy in RCTs and OSs. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses guideline was followed. In total, 54 RCTs (N=38 264) and 24 OSs (N=12 561 455) were included. In RCTs, ICI use resulted in higher risk of myocarditis (OR, 3.55 [95% CI, 2.10-5.98]), pericardial disease (OR, 2.73 [95% CI, 1.57-4.77]), and myocardial infarction (OR, 1.83 [95% CI, 1.03-3.25]), compared with non-ICI (placebo or chemotherapy). In OSs, ICI use was not associated with myocarditis, pericardial disease, or myocardial infarction compared with controls; however, combination ICIs demonstrated higher risk of myocarditis compared with single ICI use (OR, 3.07 [95% CI, 1.28-7.39]). Stroke risk was not increased with use of ICIs in RCTs. CONCLUSIONS: We demonstrated increased risk of ICI myocarditis, pericardial disease, and myocardial infarction in RCTs but not OSs. Results of this study suggest there are differences between ICI cardiotoxicity risk, possibly suggesting differences in diagnoses and management, in clinical trials versus the OSs.


Assuntos
Cardiotoxicidade , Inibidores de Checkpoint Imunológico , Neoplasias , Estudos Observacionais como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto , Humanos , Inibidores de Checkpoint Imunológico/efeitos adversos , Neoplasias/tratamento farmacológico , Medição de Risco/métodos , Fatores de Risco
2.
Artigo em Inglês | MEDLINE | ID: mdl-38643399

RESUMO

PURPOSE: While the coronal plane alignment of the knee (CPAK) classification serves as a useful guide in personalising total knee arthroplasty (TKA), the extent of its correlation with segmental coronal extra-articular knee deformities remains uncertain. This study aims to investigate the potential correlation between CPAK matrix groups and segmental coronal extra-articular deformities in prearthritic knees, shedding light on the relationship between these two factors that seems to be both essential to perform personalised TKA. MATERIALS AND METHODS: A radiological assessment of 1240 nonarthritic knees was performed by evaluating lower limb measurements following the protocol established by Paley et al. Subsequently, all knees were classified into their respective CPAK matrix groups. In our quest to discern any correlation between the CPAK matrix groups and the presence of segmental coronal extra-articular knee deformities, nine potential coronal extra-articular deformity phenotype (CEDP) groupswere identified based on medial proximal tibial angle (MPTA) and mechanical lateral distal femoral angle (mLDFA). Neutral values for MPTA and mLDFA were set at 90.0° ± 3.0° and then at 87.0° ± 2.0°. Each CPAK matrix group underwent detailed coronal morphology analysis and then, segmental coronal extra-articular deformities were assessed by comparing them with the CEDP groups. RESULTS: The study revealed a mean hip-knee-ankle angle (HKA) of 178.6° ± 4.4°, mLDFA of 86.9° ± 2.5°, MPTA of 85.4° ± 2.4°, arithmetic HKA of -1.4° ± 3.2° and joint line obliquity of 172.5° ± 3.7°. The varus CPAK groups (I/IV/VII) included 435 patients, the neutral groups (II/V/VIII) comprised 630 patients and the valgus groups (III/VI/IX) had 175 patients. Notably, CPAK matrix groups were not distinctly associated with specific coronal extra-articular deformity phenotype (CEDP) groups. Particularly among the most common CPAK matrix groups (I/II/III/IV/V), there was a significant variation in segmental coronal extra-articular deformity patterns. Moreover, when neutral MPTA/mLDFA values were set at 87.0° ± 2.0°, the CPAK matrix groups exhibited even greater variability in coronal extra-articular deformities. CONCLUSION: The CPAK matrix groups do not exhibit a direct correlation with a specific extra-articular deformity pattern (CEDP), thus rendering them unsuitable for determining segmental coronal extra-articular knee deformities. LEVEL OF EVIDENCE: Level III, retrospective diagnostic study.

3.
Glob Ment Health (Camb) ; 11: e23, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38572250

RESUMO

Background: Substance use is a complex condition with multidimensional determinants. The present study aims to find the prevalence and determinants of substance use among young people attending primary healthcare centers in India. Methods: A multicentric cross-sectional study was conducted across 15 states in India on 1,630 young people (10-24 years) attending primary health centers. The Alcohol, Smoking, and Substance Involvement Screening Test (ASSIST) was used to capture data on substance use. The degree of substance involvement was assessed and multivariate regression analysis was conducted to determine the risk factors of substance use. Results: The prevalence of substance use was 32.8%, with a median substance initiation age of 18 years. Among the substance users, 75.5% began before completing adolescence. Tobacco (26.4%), alcohol (26.1%) and cannabis (9.5%) were commonly consumed. Sociodemographic determinants included higher age, male gender, urban residence, positive family history, northeastern state residence and lower socioeconomic class. Over 80% of users had moderate or high involvement. Conclusions: High substance use prevalence among young people in Indian healthcare centers underscores the urgency of targeted intervention. Insights on determinants guide effective prevention strategies for this complex public health issue.

4.
J Robot Surg ; 18(1): 120, 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38492073

RESUMO

Robotic-assisted TKA (RATKA) is a rapidly emerging technique that has been shown to improve precision and accuracy in implant alignment in TKA. Robotic-assisted TKA (RATKA) uses computer software to create a three-dimensional model of the patient's knee. Different types of preoperative imaging, including radiographs and CT scans, are used to create these models, each with varying levels of radiation exposure. This study aims to determine the radiation dose associated with each type of imaging used in RATKA, to inform patients of the potential risks. A retrospective search of our clinical radiology and arthroplasty database was conducted to identify 140 knees. The patients were divided into three groups based on the type of preoperative imaging they received: (1) CT image-based MAKO Protocol, (2) Antero-posterior long leg alignment films (LLAF), (3) standard AP, lateral, and skyline knee radiographs. The dose of CT imaging technique for each knee was measured using the dose-length product (DLP) with units of mGycm2, whereas the measurement for XRAY images was with the dose area product (DAP) with units of Gycm2. The mean radiation dose for patients in the CT (MAKO protocol) image-based group was 1135 mGy.cm2. The mean radiation dose for patients in the LLAF group was 3081 Gycm2. The mean radiation dose for patients undergoing knee AP/lateral and skyline radiographs was the lowest of the groups, averaging 4.43 Gycm2. Through an ANOVA and post hoc analysis, the results between groups was statistically significant. In this study, we found a significant difference in radiation exposure between standard knee radiographs, LLAF and CT imaging. Nonetheless, the radiation dose for all groups is still within acceptable safety limits.


Assuntos
Artroplastia do Joelho , Exposição à Radiação , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Artroplastia do Joelho/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Estudos Retrospectivos , Exposição à Radiação/prevenção & controle
5.
Knee ; 48: 1-7, 2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38461736

RESUMO

INTRODUCTION: There is growing interest in the use of robotic TKA to improve accuracy of component positioning in Total Knee Arthroplasty (TKA). The aim of this study was to investigate the accuracy of implant component position using the ROSA® knee system with specific reference to Joint Line Height, Patella Height and Posterior Condylar Offset (PCO). METHODS: This was a retrospective review of a prospectively-maintained database of the initial 100 consecutive TKAs performed by a high volume surgeon using the ROSA® knee system. Both the image-based and imageless workflow were used and two prosthesis types were implanted. To determine the accuracy of component positioning, the immediate post-operative radiograph was reviewed and compared with the immediate pre-operative radiograph with regards to Joint Line Height, Patella Height and Posterior Condylar Offset. RESULTS: 100 consecutive patients undergoing TKA using the ROSA system were included; mean age 70 years (range 49-95 years). Mean change in joint line height was 0.2 mm, patella height (Insall-Salvati ratio) 0.01 and posterior condylar offset 0.02 mm; there was no statistically significant difference between the pre and post-operative values. No difference was demonstrated between image-based or imageless workflows, or between implant design (Persona versus Vanguard) regarding joint line height, patella height and PCO. CONCLUSION: This study validates the use of the ROSA® knee system in accurately restoring Joint Line Height, Patella Height and Posterior Condylar Offset in TKA surgery. No significant differences were found between imageless and image-based groups, or between implant designs (Persona versus Vanguard).

6.
Heliyon ; 10(4): e26525, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38404771

RESUMO

Bael is a medicinal cum fruit tree with multipurpose utility and propagated mostly through seeds. The present study aimed to assess and analyse the morpho-pomological and biochemical traits of eighty seedlings grown bael genotypes comparison with two commercial cultivars (NB-5 and NB-9) of bael. The significant differences were detected among the genotypes based on the measured morpho-pomological and biochemical traits. The morpho-pomological and biochemical traits of bael exhibited variation ranging from 6.17% to 133.65%. Trunk girth ranged from 29.50 to 63.40 cm and tree spread (N-S) varied 1.00-6.30 m. Fruit length ranged from 4.60 to 12.05 cm and fruit width ranged from 4.64 to 11.72 cm. Moreover, fruit weight ranged from 56.33 to 917.65 g and pulp percentage varied from 58.64 to 81.38%. Soluble Solid Content ranged from 25.90 to 36.77 0brix and ascorbic acid varied from 14.38 to 25.45 mg/100 g. Fruit length was positively correlated with fruit width, fruit weight, pulp percentage, seed length, seed diameter and number of seeds per fruit, while it was negatively correlated with fruit surface and total number of fruit per plant. Principal component analysis showed that 76.66% of the variability observed was explained by the 13 components. Ward cluster analysis using Euclidean distance classified the genotypes into two main clusters. These findings contribute to a better understanding of the diversity and relationships among the studied genotypes, aiding future breeding and selection programs for improved bael cultivation.

7.
J Robot Surg ; 18(1): 2, 2024 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-38175317

RESUMO

BACKGROUND: The rise of robotics in orthopaedic training, driven by the demand for better training outcomes and patient care, presents specific challenges for junior trainees due to its novelty and steep learning curve. This paper explores how orthopaedic trainees perceive and adopt robotic-assisted lower limb arthroplasty. METHODS: The study utilised the UTUAT model questionnaire as the primary data collection tool, employing targeted questions on a five-point Likert scale to efficiently gather responses from a large number of participants. Data analysis was conducted using partial least squares (PLS), a well-established method in previous technology acceptance research. RESULT: The findings indicate a favourable attitude amongst trainees towards adopting robotic technology in orthopaedic training. They acknowledge the potential advantages of improved surgical precision and patient outcomes through roboticassisted procedures. Social factors, including the views of peers and mentors, notably influence trainees' decision-making. However, the availability of resources and expert mentors did not appear to have a significant impact on trainees' intention to use robotic technology. CONCLUSION: The study contributes to the understanding of factors influencing trainees' interest in robotic surgery and emphasises the importance of creating a supportive environment for its adoption.


Assuntos
Ortopedia , Procedimentos Cirúrgicos Robóticos , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Artroplastia , Extremidade Inferior , Inquéritos e Questionários
8.
J Robot Surg ; 18(1): 33, 2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38231299

RESUMO

There is increasing adoption of robotic surgical technology in Total Knee Arthroplasty. The ROSA® knee system can be used in either image-based mode (using pre-operative calibrated radiographs) or imageless modes (using intra-operative bony registration). The Mako knee system is an image-based system (using a pre-operative CT scan). This study aimed to compare surgical accuracy between the ROSA and Mako systems with specific reference to joint line height, patella height, posterior condylar offset and tibial slope. This was a retrospective review of a prospectively collected data of the initial 50 consecutive ROSA TKAs and the initial 50 consecutive Mako TKAs performed by two high-volume surgeons. To determine the accuracy of component positioning, the immediate post-operative radiograph was reviewed and compared with the immediate pre-operative radiograph with regards to joint line height (JLH), patella height (PH), tibial slope (TS) and posterior condylar offset (PCO). Mean difference between pre- and post-operative radiographs using the ROSA knee system of joint line height was 0.47 mm (SD 0.95) posterior condylar offset 0.16 mm (SD 0.76), tibial slope 0.9 degrees (SD 1.6) and patella height 0.01 (SD 0.05). Mean difference using the MAKO knee system of joint line height was 0.26 (SD 1.08), posterior condylar offset -0.26 mm (SD 0.78), tibial slope 1.8 degrees and patella height 0.03. No significant difference was demonstrated between the accuracy of component positioning of the ROSA or MAKO knee systems. Our study is the first study to compare the accuracy of the ROSA and MAKO knee systems in total knee arthroplasty. Both systems are highly accurate in restoring native posterior condylar offset, joint line height, tibial slope and patella height in TKA with no significant difference demonstrated between the two groups.


Assuntos
Artroplastia do Joelho , Procedimentos Cirúrgicos Robóticos , Robótica , Rosa , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Tíbia
9.
Indian J Pediatr ; 2024 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-38214829

RESUMO

OBJECTIVES: To compare the performance of Modified Kramer's and Kramer's methods in terms of agreement with total serum bilirubin (TSB). METHODS: This cross-sectional study was done in Level-III neonatal unit in New Delhi. Visibly jaundiced neonates born at ≥35 wk of gestation were enrolled and examined by (i) conventional Kramer's, (ii) Modified Kramer's in artificial (MK-A) and (iii) natural daylight (MK-N), and finally sampled for estimation of TSB by point-of-care spectrophotometry. The primary outcomes were agreement of Kramer's and Modified Kramer's with TSB and accuracy in terms of proportion of bilirubin estimates lying within ±2 mg/dL of TSB; secondary outcome was agreement of MK-A and MK-N with TSB. RESULTS: A total of 144 neonates with median gestation of 37 wk and mean birth weight of 2788 g were enrolled. Bland Altman analysis between Kramer's and TSB yielded mean difference of 1.7 mg/dL, 95% limits of agreement (LOA) -3.1 to 6.6 mg/dL. For Modified Kramer's and TSB, mean difference was -0.02 mg/dL, 95% LOA -4.7 to 4.7 mg/dL under artificial light; 0.02 mg/dL, 95% LOA -4.2 to 4.2 mg/dL under natural daylight. MK-N had highest proportion of bilirubin estimates lying within ±2 mg/dL of TSB (68.7%) as compared to MK-A (59.7%) [OR, 1.77; 95% CI, 1.09 to 2.86] and Kramer's (45.8%) [OR, 1.65; 95% CI, 1.27 to 2.15]. CONCLUSIONS: Though all the three methods had poor agreement with TSB, Modified Kramer's method when performed in natural light had reasonable accuracy, however limited clinical utility, in evaluation of clinical jaundice.

10.
Kidney Med ; 5(12): 100705, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38046909

RESUMO

Heart failure with preserved ejection fraction (HFpEF) is a heterogenous syndrome with varying phenotypic expression. The phenotype chronic kidney disease (CKD) associated HFpEF is increasing in prevalence globally and is associated with increased morbidity and mortality compared to other HFpEF variants. These 2 conditions share common risk factors, including obesity, diabetes, and metabolic syndrome, as well as similar pathophysiology, including systemic inflammation, oxidative stress, elevated neurohormones, mineralocorticoid-receptor activation, and venous congestion. Given the coexistence of CKD and HFpEF, the diagnosis of HFpEF can be difficult. Moreover, treatment options for HFpEF have remained limited despite the success seen in its counterpart, heart failure with reduced ejection fraction. HFpEF encompasses complex multisystem pathophysiological perturbations beyond neurohormones, it is unlikely that a single agent can have significant benefit in this population. Recent data on sodium-glucose cotransporter 2 (SGLT2) inhibitors in HFpEF and CKD, and on glucagon-like peptide-1 (GLP-1) agonists and mineralocorticoid-receptor antagonists in metabolic syndrome, which target multiple pathways simultaneously, have led to promising therapeutics for HFpEF and CKD. In this perspective, our goal is to increase awareness of HFpEF as a multisystem disorder that shares the same disease processes seen in CKD and to emphasize that its management in individuals with CKD warrants a collective and multidisciplinary approach.

11.
Arthroplast Today ; 24: 101254, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38023654

RESUMO

Background: Operating room waste is disposed of in landfill sites, recycled, or undergoes costly, energy-intensive incineration processes. By assessing the quantity and recyclability of waste in primary hip (THA) and knee arthroplasty (TKA), we aim to identify strategies to improve sustainability. Methods: A prospective waste audit of 15 primary THA and 16 primary TKA cases was conducted at a tertiary orthopedic hospital between April and July 2022. Waste was categorized into nonhazardous, hazardous, recycling, sharps, and linens. Each category was weighed. Items disposed as nonhazardous waste were cataloged for a sample of 10 TKA and 10 THA cases. Recyclability of items was determined using packaging. Results: Average total waste generated for THA and TKA was 14.46 kg and 17.16 kg, respectively. TKA generated significantly greater waste (P < .05). Of all waste, 5.4% was recycled in TKA and just 2.9% in THA cases. The mean amount of recycled waste was significantly greater in TKA cases than that in THA cases, 0.93 kg and 0.42 kg, respectively.Hazardous waste made up the largest proportion for both TKA (69.2%) and THA (73.4%). Nonhazardous waste made up 15.1% and 11.3% of total waste for TKA and THA, respectively. In the nonhazardous waste, only 2 items (scrub-brush packaging and towel packaging) were recyclable. Conclusions: We estimate hip and knee arthroplasty generates over 2.7 million kg of waste in the United Kingdom annually. Currently, only a small percentage of waste is recycled in hip and knee arthroplasty, which could improve through increased use of recyclable plastics and clear labeling of items as recyclable by medical suppliers.

13.
Knee Surg Sports Traumatol Arthrosc ; 31(12): 5673-5680, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37884727

RESUMO

PURPOSE: Knees with unicompartmental varus osteoarthritis (OA) usually display a combination of tibiofemoral bony deformity and increased joint line convergence angle (JLCA). The JLCA is a product of intra-articular deformity and lateral soft tissue laxity. This study aims to define the correlation between the JLCA and progression of OA. METHODS: A retrospective radiological analysis of 501 patients, who underwent either high tibial osteotomy (HTO) or unicompartmental knee arthroplasty (UKA), was performed. The preoperative OA grade was reported based on the Ahlbäck and the Kellgren-Lawrence (KL). The hip-knee-ankle angle (HKA), the medial proximal tibial angle (MPTA), the mechanical lateral distal femoral angle (mLDFA) and the joint line convergence angle (JLCA) were recorded. The primary outcome was the relationship between the JLCA values and the OA grade. The secondary outcomes were comparing the JLCA and other alignment parameter values between HTO and UKA groups. RESULTS: A total of 501 (59.3% females n = 297) cases were included, comprising 293 cases of HTO and 208 cases of UKA. Patients had a mean age of 57.63 ± 8.97 years, a mean BMI of 28.37 ± 7.39 kg/m2. Patients with Ahlbäck grade 2 represented 49.3% of all patients (n = 247) and patients with KL grade 3 represented 54.7% of all patients (n = 274). A high JLCA was observed in both groups. The reported mean JLCA in the UKA group was 3.69 ± 2.1°, and in the HTO group was 2.93 ± 1.82. There was a significant association between the increase in the JLCA and the progression of OA based on both the Ahlbäck and KL grades (both p values < 0.001). The mean JLCA in patients with Ahlbäck grades 1 and 4 was 1.48 ± 1.32°, and 7 ± 0.93°, respectively. The mean JLCA in patients with KL grades 1 and 4 was 1.77 ± 1.42°, and 4.89 ± 1.73°, respectively. The mean recorded preoperative HKA angle in the UKA group was 175.06 ± 3.08°, and in the HTO group was 173.26 ± 3.02°, whereas the mean MPTA was 88.63 ± 1.72° for the UKA group and 89.31 ± 2.29° for the HTO group. CONCLUSION: The JLCA progressively increases with osteoarthritis progression in patients with unicompartmental varus knee osteoarthritis. The JLCA can potentially be used as a grading parameter for osteoarthritis progression akin to Ahlbäck and Kellgren-Lawrence grading systems.


Assuntos
Osteoartrite do Joelho , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Masculino , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Tíbia/cirurgia , Estudos Retrospectivos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Fêmur/cirurgia
14.
Indian J Radiol Imaging ; 33(4): 484-488, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37811190

RESUMO

Introduction Considerable attention is focused on preoperative templating of radiological images in patients undergoing total knee arthroplasty to obtain optimal alignment and outcome. Several radiological measurements have been described. Purpose In this study, we illustrate a new linear measurement: The linear coronal knee offset (LCKO) that can be used to analyze the coronal configuration on long leg alignment radiographs commonly undertaken during preoperative templating. Methods A retrospective search was performed of our Picture Archiving and Communication System and Radiology Information System to identify 100 lower limbs anteroposterior, weight bearing, long leg alignment view radiographs of patients referred to knee clinics over 1 year with knee pain. Demographic details, clinical indication, standard radiological measurement of the anatomical tibiofemoral angle, and the LCKO were measured and data were analyzed using Student's t -test. In addition, intraclass correlation coefficient was used to analyze for intraclass reliability. Results The average age of patients was 36.3 years (range: 12-80 years) with a male predominance. The LCKO was statistically significant between the three cohorts of patients. The mean LCKO in normal cohorts was 0.24 cm, varus was -0.6 cm, and valgus was 1.72cm. There was good inter and interobserver reliability (Kappa of 0.8 and 0.8, respectively). Conclusion The novel LCKO measurement provides a simpler method in assessing coronal lower limb malalignment and can easily identify a normal, varus, or valgus knee deformity.

15.
Radiol Case Rep ; 18(11): 3932-3935, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37663559

RESUMO

We present a unique case of neurosarcoidosis diagnosed based on thyroid biopsy and FDG PET (Fluorodeoxyglucose positron emission tomography) imaging. A patient presented for a second opinion after being placed in hospice for rapidly progressing dementia, presumed to be due to Creutzfeldt Jakob disease despite negative workup and was unable to perform activities of daily life or communicate with his wife. The patient underwent a workup including whole-body FDG PET, which showed hypermetabolic lymph nodes as well as a hypermetabolic nodule in the thyroid. Biopsy of the lymph nodes was nondiagnostic, but the thyroid biopsy tissue yielded a diagnosis of sarcoid. After ruling out other causes and reviewing the tissue pathology, the patient was diagnosed with systemic sarcoidosis with neurological involvement and started on infliximab with rapid improvement.

16.
Asian Pac J Cancer Prev ; 24(9): 3187-3193, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37774071

RESUMO

INTRODUCTION: With growing trends in tobacco consumption, it has been observed that the age of initiation is gradually decreasing. To combat the deep-rooted problem of the Society, we need to target the adolescents at the time of their first consumption of tobacco forms. Hence, this study was conducted to assess the pattern of smokeless tobacco use among school going adolescents in senior secondary schools with the assessment of the sociodemographic factors responsible for initiation of smokeless tobacco use by adolescents. METHODS: A cross-sectional survey of total sample of 714 students across 9-11 standards in 3 schools of Delhi was done using a self-administered questionnaire after obtaining approval from Institutional Ethics Committee and School Health Scheme, Delhi. RESULT: Consumption of tobacco was found to be 27.9% at a frequency of 6-9 days in a period of one month and a majority of 31 (39.2%) students initiated the use in the age group of 10-11 years. Among the different SLT products, pan masala combined with zarda with 56 (70.8%) users, was found to be the most commonly consumed SLT product. Grocery shops were preferred POS among the students as (67%) of students obtained the SLT product from this POS. 56 (70.8%) of the students wanted to quit the habit of SLT use whereas 49 (62%) students tried to quit the habit and 43 (54.4%) students sought help in order to quit the habit. DISCUSSION: Such alarming results in terms of low age of initiation in Delhi is an emerging health problem. Adequate cessation programmes and schemes must be developed and strict implementation of laws and policies to achieve a tobacco free youth is the need of hour.


Assuntos
Tabaco sem Fumaça , Adolescente , Humanos , Criança , Estudos Transversais , Uso de Tabaco/epidemiologia , Índia/epidemiologia , Instituições Acadêmicas
19.
Indian J Pediatr ; 2023 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-37523074

RESUMO

OBJECTIVES: To investigate the IgA levels and bacterial profile in umbilical cord blood (UCB) samples of mothers with risk factors compared to those without risk factors; and to understand the link between UCB culture positivity and neonatal outcomes [early-onset sepsis (EOS) or death within 7 d of life]. METHODS: This is a pilot prospective case-control study. Mothers with preterm deliveries (gestational age <34 wk) were enrolled in two groups- Cases: Those with antenatal risk factors (prolonged duration of rupture of membranes of ≥24 h or chorioamnionitis) and controls: Those without these two risk factors. Serum IgA levels was assayed and microbiological culture was tested in UCB samples. 16S sequencing to determine the UCB microbiome was performed in a subset of samples (n = 15). Neonates were followed-up for the occurrence of EOS or death until 7 d of life. RESULTS: Forty-nine mothers as cases and 50 mothers as controls were consecutively enrolled. No significant difference was observed in the IgA levels (60.5 vs. 58.1 mg/L; p = 0.71), neonatal blood culture positivity (4.1% vs. 8.0%; p = 0.41) and UCB culture positivity (30.6% vs. 26.0%; p = 0.61) in the two groups. No difference was observed between the groups in occurrence of EOS or death within 7 d of life. Proteobacteria, Firmicutes and Actinobacteria were the most abundant phyla. Serratia, Bifidobacterium, Collinsella, Meganomas and Blautia being the most common genera. CONCLUSIONS: Cord blood IgA concentration could not differentiate the neonates at-risk of infection due to its presence in both the groups.

20.
Cardiol Res ; 14(3): 237-239, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37304916

RESUMO

Background: Most studies have compared post-treatment electrocardiogram (ECG) abnormalities in cancer patients to the general population. To assess baseline cardiovascular (CV) risk, we compared pre-treatment ECG abnormalities in cancer patients with a non-cancer surgical population. Methods: We conducted a combined prospective (n = 30) and retrospective (n = 229) cohort study of patients aged 18 - 80 years with diagnosis of hematologic or solid malignancy, compared with 267 pre-surgical, non-cancer, age- and sex-matched controls. Computerized ECG interpretations were obtained, and one-third of the ECGs underwent blinded interpretation by a board-certified cardiologist (agreement r = 0.94). We performed contingency table analyses using likelihood ratio Chi-square statistics, with calculated odds ratios. Data were analyzed after propensity score matching. Results: The mean age of cases was 60.97 ± 13.86; and 59.44 ± 11.83 years for controls. Pre-treatment cancer patients had higher likelihood of abnormal ECG (odds ratio (OR): 1.55; 95% confidence interval (CI): 1.05 to 2.30), and more ECG abnormalities (χ2 = 4.0502; P = 0.04) compared with non-cancer patients. ECG abnormalities were higher in black compared to non-black patients (P = 0.001). In addition, baseline ECGs among cancer patients prior to cancer therapy demonstrated less QT prolongation and intra-ventricular conduction defect (P = 0.04); but showed more arrhythmias (P < 0.01) and atrial fibrillation (AF) (P = 0.01) compared with the general patient population. Conclusions: Based on these findings, we recommend that all cancer patients receive an ECG, a low-cost and widely available tool, as part of their CV baseline screening, prior to cancer treatment.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA