1.
J Immunol Methods ; 478: 112713, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31783021

RESUMO

BACKGROUND: Polyclonal FLCs can be used as a biomarker of inflammation and immune activation in a range of diseases. This study evaluated the performance of new FLC ELISAs (Seralite FLC ELISA) for the quantitation of polyclonal κ and λ FLC, including comparisons to existing assays. METHODS: Technical performance was assessed for the ELISA and reference ranges were generated using healthy donor serum (N = 91). Patients with a range of conditions associated with polyclonal FLC dysregulation (N = 164) were measured across platforms. RESULTS: The ELISAs generated references ranges of: 8.72-23.0 mg/L κ FLC, and 8.52-25.24 mg/L for λ FLC. ELISAs demonstrated linearity across the calibration range and intra-assay (≤ 8.7%) and inter-assay (≤ 12.3%) imprecision was low. The limit of detection was 0.63 mg/L for κ and 0.57 mg/L for λ FLC. Minimal cross-reactivity was observed for interference agents, alternate FLC and whole immunoglobulin (median change ≤3.6 mg/L). Assays showed good batch-to-batch consistency. For patient samples, methods generated different κ and λ FLC concentrations and differences were seen between methods for the number of patients classified as below, with and above references ranges for κ and λ FLC. There was no significant difference in the FLC sum between the different techniques. CONCLUSIONS: The ELISAs displayed good analytical and technical performance. The quantification of individual κ and λ FLC appears inherently different between platforms. These differences are attenuated if using the FLC sum, which was similar between methods and provided agreement in relation to patients having normal or elevated FLCs.


Assuntos
Doenças do Sistema Imunitário/diagnóstico , Cadeias kappa de Imunoglobulina/isolamento & purificação , Cadeias lambda de Imunoglobulina/isolamento & purificação , Kit de Reagentes para Diagnóstico , Biomarcadores/sangue , Conjuntos de Dados como Assunto , Ensaio de Imunoadsorção Enzimática/instrumentação , Ensaio de Imunoadsorção Enzimática/métodos , Voluntários Saudáveis , Humanos , Doenças do Sistema Imunitário/sangue , Doenças do Sistema Imunitário/imunologia , Cadeias kappa de Imunoglobulina/sangue , Cadeias kappa de Imunoglobulina/imunologia , Cadeias lambda de Imunoglobulina/sangue , Cadeias lambda de Imunoglobulina/imunologia , Valores de Referência , Reprodutibilidade dos Testes , Estudos Retrospectivos
2.
BMC Nephrol ; 18(1): 247, 2017 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-28728609

RESUMO

BACKGROUND: Acute kidney injury (AKI) is common in patients with multiple myeloma (MM). Whether serum free light chain (sFLC) measurements can distinguish between myeloma and other causes of AKI requires confirmation to guide early treatment. A rapid and portable sFLC test (Seralite®) is newly available and could reduce delays in obtaining sFLC results and accelerate diagnosis in patients with unexplained AKI. This study evaluated the accuracy of Seralite® to identify MM as the cause of AKI. METHOD: sFLCs were retrospectively analysed in patients with AKI stage 3 as per KDIGO criteria (i.e. serum creatinine ≥354 µmol/L or those on dialysis treatment) (n = 99); 45/99 patients had a confirmed MM diagnosis. RESULTS: The Seralite® κ:λ FLC ratio accurately diagnosed all MM patients in the presence of AKI: a range of 0.14-2.02 returned 100% sensitivity and specificity for identifying all non-myeloma related AKI patients. The sFLC difference (dFLC) also demonstrated high sensitivity (91%) and specificity (100%): an optimal cut-off of 399 mg/L distinguished between myeloma and non-myeloma AKI patients. We propose a pathway of patient screening and stratification in unexplained AKI for use of Seralite® in clinical practice, with a κ:λ ratio range of 0.14-2.02 and dFLC 400 mg/L as decision points. CONCLUSIONS: Seralite® accurately differentiates between AKI due to MM and AKI due to other causes in patients considered at risk of myeloma. This rapid test can sensitively screen for MM in patients with AKI and help inform early treatment intervention.


Assuntos
Injúria Renal Aguda/sangue , Injúria Renal Aguda/diagnóstico , Cadeias Leves de Imunoglobulina/sangue , Mieloma Múltiplo/sangue , Mieloma Múltiplo/diagnóstico , Injúria Renal Aguda/epidemiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mieloma Múltiplo/epidemiologia , Estudos Retrospectivos , Fatores de Tempo , Adulto Jovem
3.
Br J Haematol ; 178(2): 220-230, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28573706

RESUMO

This study aims to guide the integration of serum free light chain (sFLC) tests into clinical practice, including a new rapid test (Seralite® ). Blood and urine analysis from 5573 newly diagnosed myeloma patients identified 576 light chain only (LCO) and 60 non-secretory (NS) cases. Serum was tested by Freelite® and Seralite® at diagnosis, maximum response and relapse. 20% of LCO patients had urine FLC levels below that recommended for measuring response but >97% of these had adequate sFLC levels (oligosecretory). The recommended Freelite® sFLC ≥100 mg/l for measuring response was confirmed and the equivalent Seralite® FLC difference (dFLC) >20 mg/l identified. By both methods, ≥38% of NS patients had measurable disease (oligosecretory). Higher sFLC levels were observed on Freelite® at all time points. However, good clinical concordance was observed at diagnosis and in response to therapy. Achieving at least a very good partial response according to either sFLC method was associated with better patient survival. Relapse was identified using a Freelite® sFLC increase >200 mg/l and found 100% concordance with a corresponding Seralite® dFLC increase >30 mg/l. Both Freelite® and Seralite® sensitively diagnose and monitor LCO/oligosecretory myeloma. Rapid testing by Seralite® could fast-track FLC screening and monitoring. Response by sFLC assessment was prognostic for survival and demonstrates the clinical value of routine sFLC testing.


Assuntos
Mieloma Múltiplo/diagnóstico , Assistência ao Convalescente , Intervalo Livre de Doença , Humanos , Imunoensaio/métodos , Cadeias Leves de Imunoglobulina/metabolismo , Imunoglobulinas/metabolismo , Mieloma Múltiplo/imunologia , Mieloma Múltiplo/mortalidade , Recidiva Local de Neoplasia/diagnóstico , Recidiva Local de Neoplasia/imunologia , Recidiva Local de Neoplasia/mortalidade , Sistemas Automatizados de Assistência Junto ao Leito , Estudos Retrospectivos , Sensibilidade e Especificidade
4.
Clin Chem Lab Med ; 55(3): 424-434, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-27505089

RESUMO

BACKGROUND: Serum free light chains (FLC) are sensitive biomarkers used for the diagnosis and management of plasma cell dyscrasias, such as multiple myeloma (MM), and are central to clinical screening algorithms and therapy response criteria. We have developed a portable, near-patient, lateral-flow test (Seralite®) that quantitates serum FLC in 10 min, and is designed to eliminate sample processing delays and accelerate decision-making in the clinic. METHODS: Assay interference, imprecision, lot-to-lot variability, linearity, and the utility of a competitive-inhibition design for the elimination of antigen-excess ('hook effect') were assessed. Reference ranges were calculated from 91 healthy donor sera. Preliminary clinical validation was conducted by retrospective analysis of sera from 329 patients. Quantitative and diagnostic results were compared to Freelite®. RESULTS: Seralite® gave a broad competitive-inhibition calibration curve from below 2.5 mg/L to above 200 mg/L, provided good assay linearity (between 1.6 and 208.7 mg/L for κ FLC and between 3.5 and 249.7 mg/L for λ FLC) and sensitivity (1.4 mg/L for κ FLC and 1.7 mg/L for λ FLC), and eliminated anomalous results from antigen-excess. Seralite® gave good diagnostic concordance with Freelite® (Roche Hitachi Cobas C501) identifying an abnormal FLC ratio and FLC difference in 209 patients with newly diagnosed MM and differentiating these patients from normal healthy donors with polyclonal FLC. CONCLUSIONS: Seralite® sensitively quantitates FLC and rapidly identifies clinical conditions where FLC are abnormal, including MM.


Assuntos
Biomarcadores Tumorais/sangue , Imunoensaio/métodos , Cadeias kappa de Imunoglobulina/sangue , Cadeias lambda de Imunoglobulina/sangue , Mieloma Múltiplo/sangue , Humanos , Cadeias Leves de Imunoglobulina/sangue , Limite de Detecção , Padrões de Referência , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA