1.
Phys Med Biol ; 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38862000

RESUMO

OBJECTIVE: In proton pencil beam scanning (PBS) continuous delivery, the beam is continuously delivered without interruptions between spots. For synchrotron-based systems, the extracted beam current exhibits a spill structure, and recent publications on beam current measurements have demonstrated significant fluctuations around the nominal values. These fluctuations potentially lead to dose deviations from those calculated assuming a stable beam current. This study investigated the dosimetric implications of such beam current fluctuations during proton PBS continuous scanning. Approach: Using representative clinical proton PBS plans, we performed simulations to mimic a worst-case clinical delivery environment with beam current varies from 50% to 250% of the nominal values. The simulations used the beam delivery parameters optimized for the best beam delivery efficiency of the upcoming particle therapy system at Mayo Clinic Florida. We reconstructed the simulated delivered dose distributions and evaluated the dosimetric impact of beam current fluctuations. Main results: Despite significant beam current fluctuations resulting in deviations at each spot level, the overall dose distributions were nearly identical to those assuming a stable beam current. The 1mm/1% Gamma passing rate was 100% for all plans. Less than 0.2% root mean square error (RMSE) was observed in the PTV DVH. Minimal differences were observed in all dosimetric evaluation metrics. Significance: Our findings demonstrate that with our beam delivery system and clinical planning practice, while significant beam current fluctuations may result in large local move MU deviations at each spot level, the overall impact on the dose distribution is minimal. .

2.
Int J Part Ther ; 11: 100020, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38757080

RESUMO

Purpose: To report the current practice pattern of the proton stereotactic body radiation therapy (SBRT) for prostate treatments. Materials and Methods: A survey was designed to inquire about the practice of proton SBRT treatment for prostate cancer. The survey was distributed to all 30 proton therapy centers in the United States that participate in the National Clinical Trial Network in February, 2023. The survey focused on usage, patient selection criteria, prescriptions, target contours, dose constraints, treatment plan optimization and evaluation methods, patient-specific QA, and image-guided radiation therapy (IGRT) methods. Results: We received responses from 25 centers (83% participation). Only 8 respondent proton centers (32%) reported performing SBRT of the prostate. The remaining 17 centers cited 3 primary reasons for not offering this treatment: no clinical need, lack of volumetric imaging, and/or lack of clinical evidence. Only 1 center cited the reduction in overall reimbursement as a concern for not offering prostate SBRT. Several common practices among the 8 centers offering SBRT for the prostate were noted, such as using Hydrogel spacers, fiducial markers, and magnetic resonance imaging (MRI) for target delineation. Most proton centers (87.5%) utilized pencil beam scanning (PBS) delivery and completed Imaging and Radiation Oncology Core (IROC) phantom credentialing. Treatment planning typically used parallel opposed lateral beams, and consistent parameters for setup and range uncertainties were used for plan optimization and robustness evaluation. Measurements-based patient-specific QA, beam delivery every other day, fiducial contours for IGRT, and total doses of 35 to 40 GyRBE were consistent across all centers. However, there was no consensus on the risk levels for patient selection. Conclusion: Prostate SBRT is used in about 1/3 of proton centers in the US. There was a significant consistency in practices among proton centers treating with proton SBRT. It is possible that the adoption of proton SBRT may become more common if proton SBRT is more commonly offered in clinical trials.

3.
J Appl Clin Med Phys ; : e14342, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38590112

RESUMO

BACKGROUND: Rescanning is a common technique used in proton pencil beam scanning to mitigate the interplay effect. Advances in machine operating parameters across different generations of particle therapy systems have led to improvements in beam delivery time (BDT). However, the potential impact of these improvements on the effectiveness of rescanning remains an underexplored area in the existing research. METHODS: We systematically investigated the impact of proton machine operating parameters on the effectiveness of layer rescanning in mitigating interplay effect during lung SBRT treatment, using the CIRS phantom. Focused on the Hitachi synchrotron particle therapy system, we explored machine operating parameters from our institution's current (2015) and upcoming systems (2025A and 2025B). Accumulated dynamic 4D dose were reconstructed to assess the interplay effect and layer rescanning effectiveness. RESULTS: Achieving target coverage and dose homogeneity within 2% deviation required 6, 6, and 20 times layer rescanning for the 2015, 2025A, and 2025B machine parameters, respectively. Beyond this point, further increasing the number of layer rescanning did not further improve the dose distribution. BDTs without rescanning were 50.4, 24.4, and 11.4 s for 2015, 2025A, and 2025B, respectively. However, after incorporating proper number of layer rescanning (six for 2015 and 2025A, 20 for 2025B), BDTs increased to 67.0, 39.6, and 42.3 s for 2015, 2025A, and 2025B machine parameters. Our data also demonstrated the potential problem of false negative and false positive if the randomness of the respiratory phase at which the beam is initiated is not considered in the evaluation of interplay effect. CONCLUSION: The effectiveness of layer rescanning for mitigating interplay effect is affected by machine operating parameters. Therefore, past clinical experiences may not be applicable to modern machines.

4.
ArXiv ; 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38463503

RESUMO

A survey was designed to inquire about the practice of proton SBRT treatment for prostate cancer. The survey was distributed to all 30 proton therapy centers in the United States that participate in the National Clinical Trial Network in Feb. 2023. The survey focused on usage, patient selection criteria, prescriptions, target contours, dose constraints, treatment plan optimization and evaluation methods, patient-specific QA, and IGRT methods. Results: We received responses from 25 centers (83% participation). Only 8 respondent proton centers (32%) reported performing SBRT of the prostate. The remaining 17 centers cited three primary reasons for not offering this treatment: no clinical need, lack of volumetric imaging, and/or lack of clinical evidence. Only 1 center cited the reduction in overall reimbursement as a concern for not offering prostate SBRT. Several common practices among the 8 centers offering SBRT for the prostate were noted, such as using Hydrogel spacers, fiducial markers, and MRI for target delineation. Most proton centers (87.5%) utilized pencil beam scanning (PBS) delivery and completed Imaging and Radiation Oncology Core (IROC) phantom credentialing. Treatment planning typically used parallel opposed lateral beams, and consistent parameters for setup and range uncertainties were used for plan optimization and robustness evaluation. Measurements-based patient-specific QA, beam delivery every other day, fiducial contours for IGRT, and total doses of 35-40 GyRBE were consistent across all centers. However, there was no consensus on the risk levels for patient selection. Conclusion: Prostate SBRT is used in about 1/3 of proton centers in the US. There was a significant consistency in practices among proton centers treating with proton SBRT. It is possible that the adoption of proton SBRT may become more common if proton SBRT is more commonly offered in clinical trials.

5.
ArXiv ; 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38351927

RESUMO

Stereotactic body radiation therapy (SBRT) and hypofractionation using pencil-beam scanning (PBS) proton therapy (PBSPT) is an attractive option for thoracic malignancies. Combining the advantages of target coverage conformity and critical organ sparing from both PBSPT and SBRT, this new delivery technique has great potential to improve the therapeutic ratio, particularly for tumors near critical organs. Safe and effective implementation of PBSPT SBRT/hypofractionation to treat thoracic malignancies is more challenging than the conventionally-fractionated PBSPT due to concerns of amplified uncertainties at the larger dose per fraction. NRG Oncology and Particle Therapy Cooperative Group (PTCOG) Thoracic Subcommittee surveyed US proton centers to identify practice patterns of thoracic PBSPT SBRT/hypofractionation. From these patterns, we present recommendations for future technical development of proton SBRT/hypofractionation for thoracic treatment. Amongst other points, the recommendations highlight the need for volumetric image guidance and multiple CT-based robust optimization and robustness tools to minimize further the impact of uncertainties associated with respiratory motion. Advances in direct motion analysis techniques are urgently needed to supplement current motion management techniques.

6.
Artigo em Inglês | MEDLINE | ID: mdl-38395086

RESUMO

Stereotactic body radiation therapy (SBRT) and hypofractionation using pencil-beam scanning (PBS) proton therapy (PBSPT) is an attractive option for thoracic malignancies. Combining the advantages of target coverage conformity and critical organ sparing from both PBSPT and SBRT, this new delivery technique has great potential to improve the therapeutic ratio, particularly for tumors near critical organs. Safe and effective implementation of PBSPT SBRT/hypofractionation to treat thoracic malignancies is more challenging than the conventionally fractionated PBSPT because of concerns of amplified uncertainties at the larger dose per fraction. The NRG Oncology and Particle Therapy Cooperative Group Thoracic Subcommittee surveyed proton centers in the United States to identify practice patterns of thoracic PBSPT SBRT/hypofractionation. From these patterns, we present recommendations for future technical development of proton SBRT/hypofractionation for thoracic treatment. Among other points, the recommendations highlight the need for volumetric image guidance and multiple computed tomography-based robust optimization and robustness tools to minimize further the effect of uncertainties associated with respiratory motion. Advances in direct motion analysis techniques are urgently needed to supplement current motion management techniques.

7.
Int J Radiat Oncol Biol Phys ; 118(2): 325-329, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37689369

RESUMO

PURPOSE: The American Association of Physicists in Medicine Radiation Oncology Medical Physics Education Subcommittee (ROMPES) has updated the radiation oncology physics core curriculum for medical residents in the radiation oncology specialty. METHODS AND MATERIALS: Thirteen physicists from the United States and Canada involved in radiation oncology resident education were recruited to ROMPES. The group included doctorates and master's of physicists with a range of clinical or academic roles. Radiation oncology physician and resident representatives were also consulted in the development of this curriculum. In addition to modernizing the material to include new technology, the updated curriculum is consistent with the format of the American Board of Radiology Physics Study Guide Working Group to promote concordance between current resident educational guidelines and examination preparation guidelines. RESULTS: The revised core curriculum recommends 56 hours of didactic education like the 2015 curriculum but was restructured to provide resident education that facilitates best clinical practice and scientific advancement in radiation oncology. The reference list, glossary, and practical modules were reviewed and updated to include recent literature and clinical practice examples. CONCLUSIONS: ROMPES has updated the core physics curriculum for radiation oncology residents. In addition to providing a comprehensive curriculum to promote best practice for radiation oncology practitioners, the updated curriculum aligns with recommendations from the American Board of Radiology Physics Study Guide Working Group. New technology has been integrated into the curriculum. The updated curriculum provides a framework to appropriately cover the educational topics for radiation oncology residents in preparation for their subsequent career development.


Assuntos
Educação Médica , Internato e Residência , Radioterapia (Especialidade) , Humanos , Estados Unidos , Radioterapia (Especialidade)/educação , Física Médica/educação , Currículo
8.
Phys Med Biol ; 69(3)2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-37944480

RESUMO

Purpose. To enhance an in-house graphic-processing-unit accelerated virtual particle (VP)-based Monte Carlo (MC) proton dose engine (VPMC) to model aperture blocks in both dose calculation and optimization for pencil beam scanning proton therapy (PBSPT)-based stereotactic radiosurgery (SRS).Methods and materials. A module to simulate VPs passing through patient-specific aperture blocks was developed and integrated in VPMC based on simulation results of realistic particles (primary protons and their secondaries). To validate the aperture block module, VPMC was first validated by an opensource MC code, MCsquare, in eight water phantom simulations with 3 cm thick brass apertures: four were with aperture openings of 1, 2, 3, and 4 cm without a range shifter, while the other four were with same aperture opening configurations with a range shifter of 45 mm water equivalent thickness. Then, VPMC was benchmarked with MCsquare and RayStation MC for 10 patients with small targets (average volume 8.4 c.c. with range of 0.4-43.3 c.c.). Finally, 3 typical patients were selected for robust optimization with aperture blocks using VPMC.Results. In the water phantoms, 3D gamma passing rate (2%/2 mm/10%) between VPMC and MCsquare was 99.71 ± 0.23%. In the patient geometries, 3D gamma passing rates (3%/2 mm/10%) between VPMC/MCsquare and RayStation MC were 97.79 ± 2.21%/97.78 ± 1.97%, respectively. Meanwhile, the calculation time was drastically decreased from 112.45 ± 114.08 s (MCsquare) to 8.20 ± 6.42 s (VPMC) with the same statistical uncertainties of ~0.5%. The robustly optimized plans met all the dose-volume-constraints (DVCs) for the targets and OARs per our institutional protocols. The mean calculation time for 13 influence matrices in robust optimization by VPMC was 41.6 s and the subsequent on-the-fly 'trial-and-error' optimization procedure took only 71.4 s on average for the selected three patients.Conclusion. VPMC has been successfully enhanced to model aperture blocks in dose calculation and optimization for the PBSPT-based SRS.


Assuntos
Terapia com Prótons , Humanos , Terapia com Prótons/métodos , Dosagem Radioterapêutica , Algoritmos , Planejamento da Radioterapia Assistida por Computador/métodos , Prótons , Método de Monte Carlo , Imagens de Fantasmas , Água
9.
Med Phys ; 51(2): 1484-1498, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37748037

RESUMO

BACKGROUND: Accurate and efficient dose calculation is essential for on-line adaptive planning in proton therapy. Deep learning (DL) has shown promising dose prediction results in photon therapy. However, there is a scarcity of DL-based dose prediction methods specifically designed for proton therapy. Successful dose prediction method for proton therapy should account for more challenging dose prediction problems in pencil beam scanning proton therapy (PBSPT) due to its sensitivity to heterogeneities. PURPOSE: To develop a DL-based PBSPT dose prediction workflow with high accuracy and balanced complexity to support on-line adaptive proton therapy clinical decision and subsequent replanning. METHODS: PBSPT plans of 103 prostate cancer patients (93 for training and the other 10 for independent testing) and 83 lung cancer patients (73 for training and the other 10 for independent testing) previously treated at our institution were included in the study, each with computed tomography scans (CTs), structure sets, and plan doses calculated by the in-house developed Monte-Carlo dose engine (considered as the ground truth in the model training and testing). For the ablation study, we designed three experiments corresponding to the following three methods: (1) Experiment 1, the conventional region of interest (ROI) (composed of targets and organs-at-risk [OARs]) method. (2) Experiment 2, the beam mask (generated by raytracing of proton beams) method to improve proton dose prediction. (3) Experiment 3, the sliding window method for the model to focus on local details to further improve proton dose prediction. A fully connected 3D-Unet was adopted as the backbone. Dose volume histogram (DVH) indices, 3D Gamma passing rates with a criterion of 3%/3 mm/10%, and dice coefficients for the structures enclosed by the iso-dose lines between the predicted and the ground truth doses were used as the evaluation metrics. The calculation time for each proton dose prediction was recorded to evaluate the method's efficiency. RESULTS: Compared to the conventional ROI method, the beam mask method improved the agreement of DVH indices for both targets and OARs and the sliding window method further improved the agreement of the DVH indices (for lung cancer, CTV D98 absolute deviation: 0.74 ± 0.18 vs. 0.57 ± 0.21 vs. 0.54 ± 0.15 Gy[RBE], ROI vs. beam mask vs. sliding window methods, respectively). For the 3D Gamma passing rates in the target, OARs, and BODY (outside target and OARs), the beam mask method improved the passing rates in these regions and the sliding window method further improved them (for prostate cancer, targets: 96.93% ± 0.53% vs. 98.88% ± 0.49% vs. 99.97% ± 0.07%, BODY: 86.88% ± 0.74% vs. 93.21% ± 0.56% vs. 95.17% ± 0.59%). A similar trend was also observed for the dice coefficients. This trend was especially remarkable for relatively low prescription isodose lines (for lung cancer, 10% isodose line dice: 0.871 ± 0.027 vs. 0.911 ± 0.023 vs. 0.927 ± 0.017). The dose predictions for all the testing cases were completed within 0.25 s. CONCLUSIONS: An accurate and efficient deep learning-augmented proton dose prediction framework has been developed for PBSPT, which can predict accurate dose distributions not only inside but also outside ROI efficiently. The framework can potentially further reduce the initial planning and adaptive replanning workload in PBSPT.


Assuntos
Aprendizado Profundo , Neoplasias Pulmonares , Neoplasias da Próstata , Terapia com Prótons , Radioterapia de Intensidade Modulada , Masculino , Humanos , Dosagem Radioterapêutica , Prótons , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirurgia , Neoplasias da Próstata/radioterapia
10.
ArXiv ; 2023 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-37961731

RESUMO

Purpose: To study the effect of proton linear energy transfer (LET) on rib fracture in breast cancer patients treated with pencil-beam scanning proton therapy (PBS) using a novel tool of dose-LET volume histogram (DLVH). Methods: From a prospective registry of patients treated with post-mastectomy proton therapy to the chest wall and regional lymph nodes for breast cancer between 2015 and 2020, we retrospectively identified rib fracture cases detected after completing treatment. Contemporaneously treated control patients that did not develop rib fracture were matched to patients 2:1 considering prescription dose, boost location, reconstruction status, laterality, chest wall thickness, and treatment year.The DLVH index, V(d, l), defined as volume(V) of the structure with at least dose(d) and LET(l), was calculated. DLVH plots between the fracture and control group were compared. Conditional logistic regression (CLR) model was used to establish the relation of V(d, l) and the observed fracture at each combination of d and l. The p-value derived from CLR model shows the statistical difference between fracture patients and the matched control group. Using the 2D p-value map derived from CLR model, the DLVH features associated with the patient outcomes were extracted. Results: Seven rib fracture patients were identified, and fourteen matched patients were selected for the control group. The median time from the completion of proton therapy to rib fracture diagnosis was 12 months (range 5 to 14 months). Two patients had grade 2 symptomatic rib fracture while the remaining 5 were grade 1 incidentally detected on imaging. The derived p-value map demonstrated larger V(0-36Gy[RBE], 4.0-5.0 keV/µm) in patients experiencing fracture (p<0.1). For example, the p value for V(30 Gy[RBE], 4.0 keV/um) was 0.069. Conclusions: In breast cancer patients receiving PBS, a larger volume of chest wall receiving moderate dose and high LET may result in increased risk of rib fracture.

11.
Phys Med Biol ; 68(19)2023 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-37703907

RESUMO

Objective. To investigate the impact of scan path optimization on the dose accuracy and beam delivery time (BDT) of proton pencil beam scanning in the dose-driven continuous scanning (DDCS).Approach. A diverse set of six clinical plans, representing various spot patterns and treatment sites, was used to evaluate the effectiveness of scan time optimization and scan length optimization. The DDCS dose discrepancy and BDT with optimized scan paths was compared to the default serpentine scan path.Main results. Both scan time optimization and scan path optimization were able to reduce the DDCS dose discrepancy compared to the default serpentine scan path. All plans, except for the layer repainting lung plan, achieved a 2%/2 mm gamma pass rate of over 99% and less than 1% PTV DVH root mean square error (RMSE) through scan path optimization. In the case of the layer repainting lung plan, when compared to the default serpentine scan path, the 2%/2 mm gamma pass rate showed improvements from 91.3% to 93.1% and 95.8%, while the PTV DVH RMSE decreased from 2.1% to 1.7% and 1.1% for scan time optimization and scan length optimization, respectively. Although scan time optimization resulted in shorter total scan times for all plans compared to the default scan path and scan length optimization tended to have longer total scan times. However, due to the short total scan times and their minimal contribution to the total BDT, the impact of scan path optimization on the total BDT was practically negligible.Significance. Both scan time optimization and scan length optimization proved to be effective in minimizing DDCS dose discrepancy. No definitive winner can be determined between these two optimization approaches. Both scan time and scan length optimization had minimal effect on the total BDT.

12.
Front Oncol ; 13: 1219326, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37529688

RESUMO

Purpose: We present the first study to investigate Large Language Models (LLMs) in answering radiation oncology physics questions. Because popular exams like AP Physics, LSAT, and GRE have large test-taker populations and ample test preparation resources in circulation, they may not allow for accurately assessing the true potential of LLMs. This paper proposes evaluating LLMs on a highly-specialized topic, radiation oncology physics, which may be more pertinent to scientific and medical communities in addition to being a valuable benchmark of LLMs. Methods: We developed an exam consisting of 100 radiation oncology physics questions based on our expertise. Four LLMs, ChatGPT (GPT-3.5), ChatGPT (GPT-4), Bard (LaMDA), and BLOOMZ, were evaluated against medical physicists and non-experts. The performance of ChatGPT (GPT-4) was further explored by being asked to explain first, then answer. The deductive reasoning capability of ChatGPT (GPT-4) was evaluated using a novel approach (substituting the correct answer with "None of the above choices is the correct answer."). A majority vote analysis was used to approximate how well each group could score when working together. Results: ChatGPT GPT-4 outperformed all other LLMs and medical physicists, on average, with improved accuracy when prompted to explain before answering. ChatGPT (GPT-3.5 and GPT-4) showed a high level of consistency in its answer choices across a number of trials, whether correct or incorrect, a characteristic that was not observed in the human test groups or Bard (LaMDA). In evaluating deductive reasoning ability, ChatGPT (GPT-4) demonstrated surprising accuracy, suggesting the potential presence of an emergent ability. Finally, although ChatGPT (GPT-4) performed well overall, its intrinsic properties did not allow for further improvement when scoring based on a majority vote across trials. In contrast, a team of medical physicists were able to greatly outperform ChatGPT (GPT-4) using a majority vote. Conclusion: This study suggests a great potential for LLMs to work alongside radiation oncology experts as highly knowledgeable assistants.

13.
ArXiv ; 2023 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-37396612

RESUMO

PURPOSE: To develop a DL-based PBSPT dose prediction workflow with high accuracy and balanced complexity to support on-line adaptive proton therapy clinical decision and subsequent replanning. METHODS: PBSPT plans of 103 prostate cancer patients and 83 lung cancer patients previously treated at our institution were included in the study, each with CTs, structure sets, and plan doses calculated by the in-house developed Monte-Carlo dose engine. For the ablation study, we designed three experiments corresponding to the following three methods: 1) Experiment 1, the conventional region of interest (ROI) method. 2) Experiment 2, the beam mask (generated by raytracing of proton beams) method to improve proton dose prediction. 3) Experiment 3, the sliding window method for the model to focus on local details to further improve proton dose prediction. A fully connected 3D-Unet was adopted as the backbone. Dose volume histogram (DVH) indices, 3D Gamma passing rates, and dice coefficients for the structures enclosed by the iso-dose lines between the predicted and the ground truth doses were used as the evaluation metrics. The calculation time for each proton dose prediction was recorded to evaluate the method's efficiency. RESULTS: Compared to the conventional ROI method, the beam mask method improved the agreement of DVH indices for both targets and OARs and the sliding window method further improved the agreement of the DVH indices. For the 3D Gamma passing rates in the target, OARs, and BODY (outside target and OARs), the beam mask method can improve the passing rates in these regions and the sliding window method further improved them. A similar trend was also observed for the dice coefficients. In fact, this trend was especially remarkable for relatively low prescription isodose lines. The dose predictions for all the testing cases were completed within 0.25s.

14.
ArXiv ; 2023 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-37461414

RESUMO

Purpose: To enhance an in-house graphic-processing-unit (GPU) accelerated virtual particle (VP)-based Monte Carlo (MC) proton dose engine (VPMC) to model aperture blocks in both dose calculation and optimization for pencil beam scanning proton therapy (PBSPT)-based stereotactic radiosurgery (SRS). Methods and Materials: A module to simulate VPs passing through patient-specific aperture blocks was developed and integrated in VPMC based on simulation results of realistic particles (primary protons and their secondaries). To validate the aperture block module, VPMC was first validated by an opensource MC code, MCsquare, in eight water phantom simulations with 3cm thick brass apertures: four were with aperture openings of 1, 2, 3, and 4cm without a range shifter, while the other four were with same aperture opening configurations with a range shifter of 45mm water equivalent thickness. Then, VPMC was benchmarked with MCsquare and RayStation MC for 10 patients with small targets (average volume 8.4 cc with range of 0.4 - 43.3 cc). Finally, 3 typical patients were selected for robust optimization with aperture blocks using VPMC. Results: In the water phantoms, 3D gamma passing rate (2%/2mm/10%) between VPMC and MCsquare was 99.71±0.23%. In the patient geometries, 3D gamma passing rates (3%/2mm/10%) between VPMC/MCsquare and RayStation MC were 97.79±2.21%/97.78±1.97%, respectively. Meanwhile, the calculation time was drastically decreased from 112.45±114.08 seconds (MCsquare) to 8.20±6.42 seconds (VPMC) with the same statistical uncertainties of ~0.5%. The robustly optimized plans met all the dose-volume-constraints (DVCs) for the targets and OARs per our institutional protocols. The mean calculation time for 13 influence matrices in robust optimization by VPMC was 41.6 seconds and the subsequent on-the-fly "trial-and-error" optimization procedure took only 71.4 seconds on average for the selected three patients. Conclusion: VPMC has been successfully enhanced to model aperture blocks in dose calculation and optimization for the PBSPT-based SRS.

15.
Med Phys ; 50(8): 5252-5261, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37115647

RESUMO

BACKGROUND: Discrete spot scanning (DSS) is the commonly used method for proton pencil beam scanning (PBS). There is lack of data on the dose-driven continuous scanning (DDCS). PURPOSE: To investigate delivery benefits and dosimetric implications of DDCS versus DSS for PBS systems. METHODS: The irradiation duty factor, beam delivery time (BDT), and dose deviation were simulated for eight treatment plans in prostate, head and neck, liver, and lung, with both conventional fractionation and hypofractionation schemes. DDCS results were compared with those of DSS. RESULTS: The DDCS irradiation duty factor (range, 11%-41%) was appreciably improved compared to DSS delivery (range, 4%-14%), within which, hypofractionation schemes had greater improvement than conventional fractionation. With decreasing stop ratio constraints, the DDCS BDT reduction was greater, but dose deviation also increased. With stop ratio constraints of 2, 1, 0.5, and 0, DDCS BDT reduction reached to 6%, 10%, 12%, and 15%, respectively, and dose deviation reached to 0.6%, 1.7%, 3.0%, and 5.2% root mean square error in PTV DVH, respectively. The 3%/2-mm gamma passing rate was greater than 99% with stop ratio constraints of 2 and 1, and greater than 95% with a stop ratio of 0.5. When the stop ratio constraint was removed, five of the eight treatment plans had a 3%/2-mm gamma passing rate greater than 95%, and the other three plans had a 3%/2-mm gamma passing rate between 90% and 95%. CONCLUSIONS: The irradiation duty factor was considerably improved with DDCS. Smaller stop ratio constraints led to shorter BDTs, but with the cost of larger dose deviations. Our finding suggested that a stop ratio of 1 constraint seems to yield acceptable DDCS dose deviation.


Assuntos
Terapia com Prótons , Prótons , Masculino , Humanos , Síncrotrons , Radiometria , Cintilografia
16.
Med Phys ; 50(6): 3359-3367, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36959772

RESUMO

BACKGROUND: Mechanical accuracy should be verified before implementing a proton stereotactic radiosurgery (SRS) program. Linear accelerator (Linac)-based SRS systems often use electronic portal imaging devices (EPIDs) to verify beam isocentricity. Because proton therapy systems do not have EPID, beam isocentricity tests of proton SRS may still rely on films, which are not efficient. PURPOSE: To validate that our proton SRS system meets mechanical precision requirements and to present an efficient method to evaluate the couch and gantry's rotational isocentricity for our proton SRS system. METHODS: A dedicated applicator to hold brass aperture for proton SRS system was designed. The mechanical precision of the system was tested using a metal ball and film for 11 combinations of gantry and couch angles. A more efficient quality assurance (QA) procedure was developed, which used a scintillator device to replace the film. The couch rotational isocentricity tests were performed using orthogonal kV x-rays with the couch rotated isocentrically to five positions (0°, 315°, 270°, 225°, and 180°). At each couch position, the distance between the metal ball in kV images and the imaging isocenter was measured. The gantry isocentricity tests were performed using a cone-shaped scintillator and proton beams at five gantry angles (0°, 45°, 90°, 135°, and 180°), and the isocenter position and the distance of each beam path to the isocenter were obtained. Daily QA procedure was performed for 1 month to test the robustness and reproducibility of the procedure. RESULTS: The gantry and couch rotational isocentricity exhibited sub-mm precision, with most measurements within ±0.5 mm. The 1-month QA results showed that the procedure was robust and highly reproducible to within ±0.2 mm. The gantry isocentricity test using the cone-shaped scintillator was accurate and sensitive to variations of ±0.2 mm. The QA procedure was efficient enough to be completed within 30 min. The 1-month isocentricity position variations were within 0.5 mm, which demonstrating that the overall proton SRS system was stable and precise. CONCLUSION: The proton SRS Winston-Lutz QA procedure using a cone-shaped scintillator was efficient and robust. We were able to verify radiation delivery could be performed with sub-mm mechanical precision.


Assuntos
Radiocirurgia , Prótons , Rotação , Reprodutibilidade dos Testes , Diagnóstico por Imagem , Aceleradores de Partículas , Imagens de Fantasmas
17.
Front Oncol ; 12: 1031340, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36439436

RESUMO

The purpose of this work is to investigate collimating individual proton beamlets from a dosimetric perspective and to introduce a new device concept, the spot scanning aperture (SSA). The SSA consists of a thin aperture with a small cylindrical opening attached to a robotics system, which allows the aperture to follow and align with individual beamlets during spot delivery. Additionally, a range shifter is incorporated (source-side) for treating shallow depths. Since the SSA trims beamlets spot by spot, the patient-facing portion of the device only needs to be large enough to trim a single proton beamlet. The SSA has been modelled in an open-source Monte-Carlo-based dose engine (MCsquare) to characterize its dosimetric properties in water at depths between 0 and 10 cm while varying the following parameters: the aperture material, thickness, distance to the water phantom, distance between the aperture and attached range shifter, and the aperture opening radius. Overall, the SSA greatly reduced spot sizes for all the aperture opening radii that were tested (1 - 4 mm), especially in comparison with the extended range shifter (ranger shifter placed at 30 cm from patient); greater than 50% when placed less than 10 cm away from the patient at depths in water less than 50 mm. The peak to entrance dose ratio and linear energy transfer was found to depend on the thickness of the aperture and therefore the aperture material. Neutron production rates were also investigated and discussed.

18.
Front Oncol ; 12: 1036139, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36439480

RESUMO

Purpose: To investigate the beam delivery time (BDT) reduction due to the improvement of machine parameters for Hitachi synchrotron-based proton PBS system. Methods: BDTs for representative treatment plans were calculated to quantitatively estimate the BDT improvement from our 2015 system at Mayo Clinic in Arizona to our system to be implemented in 2025 at Mayo Clinic in Florida, and to a hypothetical future system. To specifically assess how each incremental improvement in the operating parameters reduced the total BDT, for each plan, we simulated the BDT 10,368 times with various settings of the nine different operating parameters. The effect of each operating parameter on BDT reduction and its correlation with treatment plan characteristics were analyzed. The optimal number of multiple energy extraction (MEE) layers per spill for different systems was also investigated. Results: The median (range) decrease in BDT was 60% (56%-70%) from the 2015 to the 2025 system. The following incremental improvement in parameters of the 2015 system for the 2025 system played an important role in this decreased BDT: beam intensity (8 to 20 MU/s), recapture efficiency (50% to 80%), number of MEE layers per spill (4 to 8), scanning magnet preparation and verification time (1.9 to 0.95 msec), and MEE layer switch time (200 to 100 msec). Reducing the total spill change time and scanning magnet preparation and verification time from those of the 2025 system further reduced BDT in the hypothetical future system. 8 MEE layers per spill is optimal for a system with 50% recapture efficiency; 16 MEE layers per spill is optimal for a system with 80% recapture efficiency; and more than 16 MEE layers per spill is beneficial only for a system close to 100% recapture efficiency. Conclusions: We systematically studied the effect of each machine operating parameter on the reduction in total BDT and its correlation with treatment plan characteristics. Our findings will aid new and existing synchrotron-based proton beam therapy centers to make balanced decisions on BDT benefits vs. costs when considering machine upgrade or new system selection.

19.
Med Phys ; 49(12): 7428-7437, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36208196

RESUMO

BACKGROUND: Parallel-opposed lateral beams are the conventional beam arrangements in proton therapy for prostate cancer. However, when considering linear energy transfer (LET) and RBE effects, alternative beam arrangements should be investigated. PURPOSE: To investigate the dose and dose averaged LET (LETd ) impact of using new beam arrangements rotating beams 5°-15° posteriorly to the laterals in prostate cancer treated with pencil-beam-scanning (PBS) proton therapy. METHODS: Twenty patients with localized prostate cancer were included in this study. Four proton treatment plans for each patient were generated utilizing 0°, 5°, 10°, and 15° posterior oblique beam pairs relative to parallel-opposed lateral beams. Dose-volume histograms (DVHs) from posterior oblique beams were analyzed. Dose-LETd -volume histogram (DLVH) was employed to study the difference in dose and LETd with each beam arrangement. DLVH indices, V ( d , l ) $V( {d,l} )$ , defined as the cumulative absolute volume that has a dose of at least d (Gy[RBE]) and a LETd of at least l (keV/µm), were calculated for both the rectum and bladder to the whole group of patients and two-sub groups with and without hydrogel spacer. These metrics were tested using Wilcoxon signed-rank test. RESULTS: Rotating beam angles from laterals to slightly posterior by 5°-15° reduced high LETd volumes while it increased the dose volume in the rectum and increased LETd in bladders. Beam angles rotated five degrees posteriorly from laterals (i.e., gantry in 95° and 265°) are proposed since they achieved the optimal balance of better LETd sparing and minimal dose increase in the rectum. A reduction of V(50 Gy[RBE], 2.6 keV/µm) from 7.41 to 3.96 cc (p < 0.01), and a slight increase of V(50 Gy[RBE], 0 keV/µm) from 20.1 to 21.6 cc (p < 0.01) were observed for the group without hydrogel spacer. The LETd sparing was less effective for the group with hydrogel spacer, which achieved the reduction of V(50 Gy[RBE], 2.6 keV/µm) from 4.28 to 2.10 cc (p < 0.01). CONCLUSIONS: Posterior oblique angle plans improved LETd sparing of the rectum while sacrificing LETd sparing in the bladder in the treatment of prostate cancer with PBS. Beam angle modification from laterals to slightly posterior may be a strategy to redistribute LETd and perhaps reduce rectal toxicity risks in prostate cancer patients treated with PBS. However, the effect is reduced for patients with hydrogel spacer.


Assuntos
Neoplasias da Próstata , Terapia com Prótons , Masculino , Humanos , Reto , Bexiga Urinária , Transferência Linear de Energia , Terapia com Prótons/efeitos adversos , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Hidrogéis , Planejamento da Radioterapia Assistida por Computador
20.
Phys Med Biol ; 67(17)2022 08 17.
Artigo em Inglês | MEDLINE | ID: mdl-35878611

RESUMO

Objective.To investigate synchrotron-based proton pencil beam scanning (PBS) beam delivery time (BDT) using novel continuous scanning mode.Approach.A BDT calculation model was developed for the Hitachi particle therapy system. The model was validated against the measured BDT of 36 representative clinical proton PBS plans with discrete spot scanning (DSS) in the current Hitachi proton therapy system. BDTs were calculated with the next generation using Mayo Clinic Florida system operating parameters for conventional DSS, and novel dose driven continuous scanning (DDCS). BDTs of DDCS with and without Break Spots were investigated.Main results.For DDCS without Break Spots, the use of Stop Ratio to control the transit dose largely reduced the beam intensity and consequently, severely prolonged the BDT. DDCS with Break Spots was able to maintain a sufficiently high beam intensity while controlling transit dose. In DDCS with Break Spots, tradeoffs were made between beam intensity and number of Break Spots. Therefore, BDT decreased with increased beam intensity but reached a plateau for beam intensity larger than 10 MU s-1. Averaging over all clinical plans, BDT was reduced by 10% for DDCS with Break Spots compared to DSS.Significance.DDCS with Break Spots reduced BDT. DDCS has the potential to further reduce BDT under the ideal scenario which requests both stable beam intensity extraction and accurately modelling the transit dose. Further investigation is warranted.


Assuntos
Terapia com Prótons , Terapia com Prótons/métodos , Prótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Síncrotrons