Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 31(7): 11805, 2023 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-37155807

RESUMO

An error on the part of the authors in drafting resulted in Eq. (3) being incorrect in the published paper [Opt. Express25, 20612 (2017)10.1364/OE.25.020612]. We present a corrected version of the equation. It should be noted that this does not affect the presented results or conclusions of the paper.

2.
Acta Biomater ; 164: 332-345, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37059408

RESUMO

The hierarchical design of bio-based nanostructured materials such as bone enables them to combine unique structure-mechanical properties. As one of its main components, water plays an important role in bone's material multiscale mechanical interplay. However, its influence has not been quantified at the length-scale of a mineralised collagen fibre. Here, we couple in situ micropillar compression, and simultaneous synchrotron small angle X-ray scattering (SAXS) and X-ray diffraction (XRD) with a statistical constitutive model. Since the synchrotron data contain statistical information on the nanostructure, we establish a direct connection between experiment and model to identify the rehydrated elasto-plastic micro- and nanomechanical fibre behaviour. Rehydration led to a decrease of 65%-75% in fibre yield stress and compressive strength, and 70% in stiffness with a 3x higher effect on stresses than strains. While in agreement with bone extracellular matrix, the decrease is 1.5-3x higher compared to micro-indentation and macro-compression. Hydration influences mineral more than fibril strain with the highest difference to the macroscale when comparing mineral and tissue levels. The effect of hydration seems to be strongly mediated by ultrastructural interfaces while results provide insights towards mechanical consequences of reported water-mediated structuring of bone apatite. The missing reinforcing capacity of surrounding tissue for an excised fibril array is more pronounced in wet than dry conditions, mainly related to fibril swelling. Differences leading to higher compressive strength between mineralised tissues seem not to depend on rehydration while the lack of kink bands supports the role of water as an elastic embedding influencing energy-absorption mechanisms. STATEMENT OF SIGNIFICANCE: Characterising structure-property-function relationships in hierarchical biological materials helps us to elucidate mechanisms that enable their unique properties. Experimental and computational methods can advance our understanding of their complex behaviour with the potential to inform bio-inspired material development. In this study, we close a gap for bone's fundamental mechanical building block at micro- and nanometre length scales. We establish a direct connection between experiments and simulations by coupling in situ synchrotron tests with a statistical model and quantify the behaviour of rehydrated single mineralised collagen fibres. Results suggest a high influence of hydration on structural interfaces, and the role of water as an elastic embedding by outlining important differences between wet and dry elasto-plastic properties of mineral nanocrystals, fibrils and fibres.


Assuntos
Colágeno , Minerais , Espalhamento a Baixo Ângulo , Estresse Mecânico , Difração de Raios X
3.
Sci Rep ; 12(1): 8052, 2022 05 16.
Artigo em Inglês | MEDLINE | ID: mdl-35577824

RESUMO

Ocean acidification is a threat to deep-sea corals and could lead to dramatic and rapid loss of the reef framework habitat they build. Weakening of structurally critical parts of the coral reef framework can lead to physical habitat collapse on an ecosystem scale, reducing the potential for biodiversity support. The mechanism underpinning crumbling and collapse of corals can be described via a combination of laboratory-scale experiments and mathematical and computational models. We synthesise data from electron back-scatter diffraction, micro-computed tomography, and micromechanical experiments, supplemented by molecular dynamics and continuum micromechanics simulations to predict failure of coral structures under increasing porosity and dissolution. Results reveal remarkable mechanical properties of the building material of cold-water coral skeletons of 462 MPa compressive strength and 45-67 GPa stiffness. This is 10 times stronger than concrete, twice as strong as ultrahigh performance fibre reinforced concrete, or nacre. Contrary to what would be expected, CWCs retain the strength of their skeletal building material despite a loss of its stiffness even when synthesised under future oceanic conditions. As this is on the material length-scale, it is independent of increasing porosity from exposure to corrosive water or bioerosion. Our models then illustrate how small increases in porosity lead to significantly increased risk of crumbling coral habitat. This new understanding, combined with projections of how seawater chemistry will change over the coming decades, will help support future conservation and management efforts of these vulnerable marine ecosystems by identifying which ecosystems are at risk and when they will be at risk, allowing assessment of the impact upon associated biodiversity.


Assuntos
Antozoários , Animais , Antozoários/química , Recifes de Corais , Ecossistema , Concentração de Íons de Hidrogênio , Oceanos e Mares , Água do Mar/química , Água , Microtomografia por Raio-X
4.
Sci Rep ; 11(1): 11007, 2021 05 26.
Artigo em Inglês | MEDLINE | ID: mdl-34040009

RESUMO

The underlying constraint of ultrashort pulsed laser ablation in both the clinical and micromachining setting is the uncertainty regarding the impact on the composition of material surrounding the ablated region. A heat model representing the laser-tissue interaction was implemented into a finite element suite to assess the cumulative temperature response of bone during ultrashort pulsed laser ablation. As an example, we focus on the extraction of mineralised collagen fibre micropillars. Laser induced heating can cause denaturation of the collagen, resulting in ultrastructural loss which could affect mechanical testing results. Laser parameters were taken from a used micropillar extraction protocol. The laser scanning pattern consisted of 4085 pulses, with a final radial pass being 22 [Formula: see text] away from the micropillar. The micropillar temperature was elevated to 70.58 [Formula: see text], remaining 79.42 [Formula: see text] lower than that of which we interpret as an onset for denaturation. We verified the results by means of Raman microscopy and Energy Dispersive X-ray Microanalysis and found the laser-material interaction had no effect on the collagen molecules or mineral nanocrystals that constitute the micropillars. We, thus, show that ultrashort pulsed laser ablation is a safe and viable tool to fabricate bone specimens for mechanical testing at the micro- and nanoscale and we provide a computational model to efficiently assess this.

5.
Opt Express ; 28(17): 25491-25501, 2020 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-32907069

RESUMO

Hollow core negative curvature fibres (NCFs) are a relatively new class of microstructured optical fibre with potential applications in areas such as the delivery of high power laser light and gas sensing. For sensing, it is necessary for the measurand to interact with the guided mode. To facilitate this, a novel femtosecond laser-based machining protocol has been developed that allows the precision sculpting of access slots into the NCF core along the length of the fibre. The process is a direct-write process using a digitally defined scanning strategy with no need for physical masks or additional processing such as wet etchants and/or focussed ion beam machining. Due to the inherent flexibility of the machining strategy and the high level of control over the depth of material removal, it is likely that this new technique will be transferable to a wide range of microstructured fibres.

6.
Appl Opt ; 59(16): 4988-4996, 2020 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-32543496

RESUMO

We investigate the impact of input pulse duration and peak power of a femtosecond laser on pulse broadening and propagation losses in selected hollow-core antiresonant fiber (HC-ARF). The mixed effects of strong self-phase modulation and relatively weak Raman scattering broaden the spectral width, which in turn causes a portion of the output spectrum to exceed the transmission band of the fiber, resulting in transmission losses. By designing and setting up a gas flow control system and a vacuum system, the nonlinear behavior of the fiber filled with different pressurized gases is investigated. The experimental results show that replacing the air molecules in the fiber core with argon can weaken pulse broadening and increase the transmittable peak power by 14 MW for a given 122 MW input, while a vacuum system can reduce the nonlinearity to a larger extent, therefore enhancing the transmission of HC-ARF by at least 26 MW.

7.
Micromachines (Basel) ; 11(2)2020 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-32053957

RESUMO

Optical biopsy describes a range of medical procedures in which light is used to investigate disease in the body, often in hard-to-reach regions via optical fibres. Optical biopsies can reveal a multitude of diagnostic information to aid therapeutic diagnosis and treatment with higher specificity and shorter delay than traditional surgical techniques. One specific type of optical biopsy relies on Raman spectroscopy to differentiate tissue types at the molecular level and has been used successfully to stage cancer. However, complex micro-optical systems are usually needed at the distal end to optimise the signal-to-noise properties of the Raman signal collected. Manufacturing these devices, particularly in a way suitable for large scale adoption, remains a critical challenge. In this paper, we describe a novel fibre-fed micro-optic system designed for efficient signal delivery and collection during a Raman spectroscopy-based optical biopsy. Crucially, we fabricate the device using a direct-laser-writing technique known as ultrafast laser-assisted etching which is scalable and allows components to be aligned passively. The Raman probe has a sub-millimetre diameter and offers confocal signal collection with 71.3% ± 1.5% collection efficiency over a 0.8 numerical aperture. Proof of concept spectral measurements were performed on mouse intestinal tissue and compared with results obtained using a commercial Raman microscope.

8.
J Biophotonics ; 12(11): e201900055, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31240824

RESUMO

Ultrashort pulse lasers offer great promise for tissue resection with exceptional precision and minimal thermal damage. Surgery in the bowel requires high precision and minimal necrotic tissue to avoid severe complications such as perforation. The deployment of ultrashort lasers in minimally invasive or endoscopic procedures has been hindered by the lack of suitable optical fibres for high peak powers. However, recent developments of hollow core microstructured fibres provide potential for delivery of such pulses throughout the body. In this study, analysis of laser ablation via a scanning galvanometer on a porcine colon tissue model is presented. A thermally damaged region (<85 µm) and fine depth control of ablation using the pulse energies 46 and 33 µJ are demonstrated. It is further demonstrated that such pulses suitable for precision porcine colon resection can be flexibly delivered via a hollow core negative curvature fibre (HC-NCF) and again ablation depth can be controlled with a thermally damaged region <85 µm. Ablation volumes are comparable to that of early stage lesions in the inner lining of the colon. This study concludes that the combination of ultrashort pulses and flexible fibre delivery via HC-NCF present a viable route to new minimally invasive surgical procedures.


Assuntos
Técnicas de Ablação/instrumentação , Colo/cirurgia , Lasers , Animais , Colo/citologia , Suínos
9.
Acta Biomater ; 89: 313-329, 2019 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-30858052

RESUMO

The increasing incidence of osteoporotic bone fractures makes fracture risk prediction an important clinical challenge. Computational models can be utilised to facilitate such analyses. However, they critically depend on bone's underlying hierarchical material description. To understand bone's irreversible behaviour at the micro- and nanoscale, we developed an in situ testing protocol that allows us to directly relate the experimental data to the mechanical behaviour of individual mineralised collagen fibres and its main constitutive phases, the mineralised collagen fibrils and the mineral nanocrystals, by combining micropillar compression of single fibres with small angle X-ray scattering (SAXS) and X-ray diffraction (XRD). Failure modes were assessed by SEM. Strain ratios in the elastic region at fibre, fibril and mineral levels were found to be approximately 22:5:2 with strain ratios at the point of compressive strength of 0.23 ±â€¯0.11 for fibril-to-fibre and 0.07 ±â€¯0.01 for mineral-to-fibre levels. Mineral-to-fibre levels showed highest strain ratios around the apparent yield point, fibril-to-fibre around apparent strength. The mineralised collagen fibrils showed a delayed mechanical response, contrary to the mineral phase, which points towards preceding deformations of mineral nanocrystals in the extrafibrillar matrix. No damage was measured at the level of the mineralised collagen fibre which indicates an incomplete separation of the mineral and collagen, and an extrafibrillar interface failure. The formation of kink bands and the gradual recruitment of fibrils upon compressive loading presumably led to localised strains. Our results from a well-controlled fibrillar architecture provide valuable input for micromechanical models and computational non-linear bone strength analyses that may provide further insights for personalised diagnosis and treatment as well as bio-inspired implants for patients with bone diseases. STATEMENT OF SIGNIFICANCE: Musculoskeletal diseases such as osteoporosis, osteoarthritis or bone cancer significantly challenge health care systems and make fracture risk prediction and treatment optimisation important clinical goals. Computational methods such as finite element models have the potential to optimise analyses but highly depend on underlying material descriptions. We developed an in situ testing set-up to directly relate experimental data to the mechanical behaviour of bone's fundamental building block, the individual mineralised collagen fibre and its main constituents. Low multilevel strain ratios suggest high deformations in the extrafibrillar matrix and energy dissipation at the interfaces, the absence of damage indicates both an incomplete separation between mineral and collagen and an extrafibrillar interface failure. The formation of kink bands in the fibril-reinforced composite presumably led to localised strains. The deformation behaviour of a well-controlled fibrillar architecture provides valuable input for non-linear bone strength analyses.


Assuntos
Colágeno/química , Força Compressiva , Matriz Extracelular/química , Estresse Mecânico , Espalhamento a Baixo Ângulo , Turquia , Difração de Raios X
10.
Opt Express ; 25(17): 20612-20621, 2017 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-29041739

RESUMO

We present the results of measurements of resonant spectral bend loss using a novel apparatus in a series of hollow core anti-resonant optical fibers, important for their applications in the delivery of industrial power ultra-short laser pulses. The measured bend losses exhibit clear wavelength-bend diameter resonances. We demonstrate, in good agreement with theoretical analysis, that the sensitivity to bend diameter (in terms of minimum bend radii) is dependent on the ratio between cladding and core structure size. By decreasing the cladding capillary diameter: core diameter ratio from 0.70 to 0.43 the minimum bend diameter is decreased from >160 mm to ~15 mm at a wavelength of 800 nm. Furthermore it is demonstrated that the exact position of the loss bands is highly dependent on the orientation of the fiber structure with the bend plane.

11.
Opt Express ; 23(7): 8498-506, 2015 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-25968688

RESUMO

In this paper we present an anti-resonant guiding, low-loss Negative Curvature Fiber (NCF) for the efficient delivery of high energy short (ns) and ultrashort (ps) pulsed laser light in the green spectral region. The fabricated NCF has an attenuation of 0.15 dB/m and 0.18 dB/m at 532 nm and 515 nm respectively, and provided robust transmission of nanosecond and picosecond pulses with energies of 0.57 mJ (10.4 kW peak power) and 30 µJ (5 MW peak power) respectively. It provides single-mode, stable (low bend-sensitivity) output and maintains spectral and temporal properties of the source laser beam. The practical application of fiber-delivered pulses has been demonstrated in precision micro-machining and marking of metals and glass.

12.
Appl Opt ; 53(19): 4233-8, 2014 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-25089985

RESUMO

We report picosecond laser welding of similar and dissimilar materials based on plasma formation induced by a tightly focused beam from a 1030 nm, 10 ps, 400 kHz laser system. Specifically, we demonstrate the welding of fused silica, borosilicate, and sapphire to a range of materials including borosilicate, fused silica, silicon, copper, aluminum, and stainless steel. Dissimilar material welding of glass to aluminum and stainless steel has not been previously reported. Analysis of the borosilicate-to-borosilicate weld strength compares well to those obtained using similar welding systems based on femtosecond lasers. There is, however, a strong requirement to prepare surfaces to a high (10-60 nm Ra) flatness to ensure a successful weld.

13.
Opt Express ; 21(19): 22742-53, 2013 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-24104161

RESUMO

We present high average power picosecond and nanosecond pulse delivery at 1030 nm and 1064 nm wavelengths respectively through a novel hollow-core Negative Curvature Fiber (NCF) for high-precision micro-machining applications. Picosecond pulses with an average power above 36 W and energies of 92 µJ, corresponding to a peak power density of 1.5 TWcm⁻² have been transmitted through the fiber without introducing any damage to the input and output fiber end-faces. High-energy nanosecond pulses (>1 mJ), which are ideal for micro-machining have been successfully delivered through the NCF with a coupling efficiency of 92%. Picosecond and nanosecond pulse delivery have been demonstrated in fiber-based laser micro-machining of fused silica, aluminum and titanium.

14.
Appl Opt ; 50(18): 2899-905, 2011 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-21691353

RESUMO

We demonstrate the adverse influence of temporal fluctuations of the phase modulation of a spatial light modulator (SLM) display device on nanosecond laser micromachining. We show that active cooling of the display reduces the amplitude of these fluctuations, and we demonstrate a process synchronization technique developed to compensate for these fluctuations when applying the SLM to laser materials processing. For alternative SLM devices developed specifically for laser wavefront control (which do not exhibit such flickering problems), we show that our process synchronization approach is also beneficial to avoid machining glitches when switching quickly between different phase profiles (and hence beam patterns).

15.
Appl Opt ; 50(12): 1779-85, 2011 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-21509071

RESUMO

Laser marking is demonstrated using a nanosecond (ns) pulse duration laser in combination with a liquid crystal spatial light modulator to generate two-dimensional patterns directly onto thin films and bulk metal surfaces. Previous demonstrations of laser marking with such devices have been limited to low average power lasers. Application in the ns regime enables more complex, larger scale marks to be generated with more widely available and industrially proven laser systems. The dynamic nature of the device is utilized to improve mark quality by reducing the impact of the inherently speckled intensity distribution across the generated image and reduce thermal effects in the marked surface.

16.
Opt Express ; 18(16): 17059-65, 2010 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-20721094

RESUMO

The application of a commercially available spatial light modulator (SLM) to control the spatial intensity distribution of a nanosecond pulsed laser for micromachining is described for the first time. Heat sinking is introduced to increase the average power handling capabilities of the SLM beyond recommended limits by the manufacturer. Complex intensity patterns are generated, using the Inverse Fourier Transform Algorithm, and example laser machining is demonstrated. The SLM enables both complex beam shaping and also beam steering.


Assuntos
Algoritmos , Análise de Fourier , Lasers , Luz , Microtecnologia/instrumentação , Desenho de Equipamento
17.
Appl Opt ; 46(17): 3432-8, 2007 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-17514301

RESUMO

Fiber delivery of 64.7 mJ laser pulses (approximately 6 ns duration) from a Q-switched Nd:YAG laser operating at 532 nm is demonstrated. A custom diffractive optical element was used to shape the laser beam and facilitate coupling into a linear fiber array. This launch arrangement achieves an improvement in launch efficiency compared with a circular fiber bundle evaluated in previous work and the delivery of higher pulse energies is demonstrated. The bundle is capable of delivering light of sufficient pulse energy and, importantly, with suitable focusability, to generate a thin light sheet for the fluid flow measurement technique of particle image velocimetry (PIV). Fiber delivery offers an advantage, in terms of optical access, for the application of PIV to enclosed measurement volumes, such as the cylinder of a combustion engine.

18.
Appl Opt ; 45(18): 4209-18, 2006 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-16778928

RESUMO

Due to their capability for supporting high-peak powers, large-core hollow optical fibers may be used to deliver high-peak-power nanosecond pulses for the fluid flow measurement technique of particle image velocimetry [Meas. Sci. Technol. 16, 1119 (2005)]. One drawback of using such fibers for fluid flow measurements is that the output suffers from a speckled interference pattern due to the fiber's multimode nature, which can lead to a loss of spatial information and reduced data quality. Presented here is a technique to reduce the speckle contrast from these fibers when delivering nanosecond pulses. Significant smoothing of the output intensity distribution is demonstrated, giving an improved source of illumination for fluid flow measurements and other imaging techniques requiring pulsed laser illumination.

19.
Appl Opt ; 44(21): 4582-8, 2005 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-16047910

RESUMO

We report the delivery of high-energy nanosecond pulses (approximately 65 ns pulse width) from a high-repetition-rate (up to 100 kHz) Q-switched Nd:YAG laser through the fundamental mode of a hollow-core photonic crystal fiber (HC-PCF) at 1064 nm. The guided mode in the HC-PCF has a low overlap with the glass, allowing delivery of pulses with energies above those attainable with other fibers. Energies greater than 0.5 mJ were delivered in a single spatial mode through the hollow-core fiber, providing the pulse energy and high beam quality required for micromachining of metals. Practical micromachining of a metal sheet by fiber delivery has been demonstrated.


Assuntos
Tecnologia de Fibra Óptica/instrumentação , Lasers , Manufaturas , Metalurgia/métodos , Cristalização , Transferência de Energia , Desenho de Equipamento , Análise de Falha de Equipamento , Miniaturização/instrumentação , Miniaturização/métodos , Fótons
20.
Appl Opt ; 43(26): 5037-46, 2004 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-15468705

RESUMO

Fluctuations in beam quality (M2) have been observed on a pulse-to-pulse basis from an industrial Nd:YAG laser. This was achieved with a compact multiplane imaging method incorporating quadratically distorted diffraction gratings, which enabled simultaneous imaging of nine planes on a single CCD array. With this system, we measured across a range of beam qualities with an associated error (in M2 variation) of the order of 0.7%. Application of the system to fiber-optic beam delivery and laser drilling is demonstrated.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA