Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Cureus ; 16(2): e55290, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38558607

RESUMO

As laparoscopy gained global popularity in oncologic surgery, the challenge of detecting lymph nodes spurred researchers to explore innovative techniques and approach the situation from a fresh perspective. While many proposed methods have faded into obscurity, the utilization of indocyanine green (ICG) in the surgical treatment of oncologic patients has continued to advance. The immense potential of this dye is widely acknowledged, yet its full extent and limitations in lymphatic mapping for colorectal cancer remain to be precisely determined. This article aims to assess the magnitude of its potential and explore the constraints based on insights from clinical studies published by pioneering researchers. A systematic review of the existing literature, comprising articles in English, was conducted using the Scopus, PubMed, and Springer Link databases. The search employed keywords such as "colorectal cancer" AND/OR "indocyanine green," "fluorescence" AND/OR "lymphatic mapping" AND/OR "lymph nodes." Initially identifying 129 articles, the application of selection criteria narrowed down the pool to 10 articles, which served as the primary sources of data for our review. Despite the absence of a standardized protocol for the application of ICG in colorectal cancer, particularly in the context of lymphatic mapping, the detection rates have exhibited considerable variation across studies. Nevertheless, all authors unanimously regarded this technique as beneficial and promising. Additionally, it is advocated as an adjunctive tool to enhance the accuracy of cancer staging. Near-infrared (NIR)-enhanced surgery holds the promise of transforming the landscape of oncologic surgery, emerging as a valuable tool for surgeons. However, the absence of a standardized technique and the subjective nature of result assessment impose limitations on the potential of this method. Consequently, it can be inferred that the establishment of a universally accepted protocol, encompassing parameters such as dose, concentration, technique, and site of administration of ICG, along with the optimal time needed for fluorescence visualization, would enhance the outcomes. Emphasizing the accurate selection of patients is crucial to prevent the occurrence of false-negative results.

2.
Nanomaterials (Basel) ; 13(9)2023 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-37177122

RESUMO

The aim of this research was to study the effect of MnxOy nanoparticles stabilized with L-methionine on the morphofunctional characteristics of the barley (Hordeum vulgare L.) crop. MnxOy nanoparticles stabilized with L-methionine were synthesized using potassium permanganate and L-methionine. We established that MnxOy nanoparticles have a diameter of 15 to 30 nm. According to quantum chemical modeling and IR spectroscopy, it is shown that the interaction of MnxOy nanoparticles with L-methionine occurs through the amino group. It is found that MnxOy nanoparticles stabilized with L-methionine have positive effects on the roots and seedling length, as well as the seed germination energy. The effect of MnxOy nanoparticles on Hordeum vulgare L. seeds is nonlinear. At a concentration of 0.05 mg/mL, there was a statistically significant increase in the length of seedlings by 68% compared to the control group. We found that the root lengths of samples treated with MnxOy nanoparticle sols with a concentration of 0.05 mg/mL were 62.8%, 32.7%, and 158.9% higher compared to samples treated with L-methionine, KMnO4, and the control sample, respectively. We have shown that at a concentration of 0.05 mg/mL, the germination energy of seeds increases by 50.0% compared to the control sample, by 10.0% compared to the samples treated with L-methionine, and by 13.8% compared to the samples treated with KMnO4.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA