Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Cureus ; 16(4): e58356, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38756279

RESUMO

We experienced a case of bilateral corneal thinning during the oral taking of S-1, a combination anti-cancer drug of tegafur, gimeracil, and oteracil-potassium. A 69-year-old man was prescribed oral S-1 for the treatment of duodenal papilla adenocarcinoma and intraductal papillary mucinous neoplasm. However, he developed a decrease in visual acuity in both eyes after three cycles of S-1 oral taking, and ophthalmic examination revealed corneal thinning exceeding 100 µm and an increase in high-order irregularity of cornea in both eyes. After one month after discontinuation of S-1, his visual acuity and corneal thickness returned to its previous levels. Besides corneal ulcers and perforations, corneal thinning can be recognized as a potential corneal side effect necessitating monitoring during S-1 treatment.

2.
Am J Ophthalmol Case Rep ; 33: 102008, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38374947

RESUMO

Purpose: This study aims to present two different types of giant bleb formation following Ahmed Glaucoma Valve (AGV) implantation: an anterior enlarged giant bleb and a posterior enlarged giant bleb. Observations: In Case 1, a 70-year-old Japanese male underwent AGV implantation for neovascular glaucoma in his right eye (OD). Preoperatively, the patient's intraocular pressure (IOP) and best corrected visual acuity (BCVA) were 23 mmHg and 0.6, respectively, OD, while using 3 antiglaucoma topical medications. Two months post-surgery, the patient began experiencing double vision. Slit lamp evaluation revealed no abnormalities, IOP and BCVA were 24.0 mmHg and 0.8, respectively, OD. A posteriorly enlarged bleb in the superotemporal quadrant OD was found to be causing displacement on T2-weighted orbital MRI. The patient underwent surgical excision of the anterior bleb wall. By three weeks post-surgery, the double vision resolved; IOP and BCVA were 17 mmHg and 0.7, respectively, and a normal bleb in the slit lamp evaluation was identified OD. In Case 2, a 10-year-old Japanese female underwent AGV implantation for childhood glaucoma associated with congenital cataract OD. Preoperatively, IOP and BCVA were 30 mmHg and 0.5, respectively, OD, while using 3 antiglaucoma topical medications. She underwent pars plana vitrectomy (PPV) in addition to AGV implantation. Seven months post-surgery, slip lamp evaluation revealed an anteriorly enlarged giant bleb that only cause her a cosmetic concern. Conclusions and Importance: There are two types of giant bleb formation following AGV implantation based on the direction of the enlargement: an anterior enlarged giant bleb and a posterior enlarged giant bleb. The introduction of this classification contribute to better understanding and management of this unusual surgical complication.

3.
J Clin Med ; 12(23)2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38068513

RESUMO

This study compared the effectiveness and safety of 120-degree (nasal) and 240-degree (bilateral) incisions in Tanito Microhook Trabeculotomy (TMH) combined with cataract surgery in patients with open-angle glaucoma. From a pool of 185 eyes, 67 eyes from 67 subjects were selected for each incision group using propensity score matching to align age, sex, glaucoma type, and preoperative intraocular pressure (IOP). The study found that preoperative IOP, initially 18.6 mmHg in both groups, decreased to 13.2 mmHg in the nasal group and 12.8 mmHg in the bilateral group 12 months postoperatively, representing reductions of 29% and 31%, respectively. Similarly, medication scores decreased from 3.4 to 2.7 in the nasal group and from 3.1 to 2.5 in the bilateral group. Notably, the bilateral incision group exhibited a significantly higher hyphema red blood cell score compared to the nasal group (p < 0.0001). Across the study period, other parameters such as IOP, medication score, visual acuity, anterior chamber flare, corneal endothelial cell density, visual field mean deviation, and the frequency of surgical complications other than hyphema were similar between the groups. The study concluded that TMH combined with cataract surgery is equally effective and safe regardless of incision width, although narrower incisions resulted in reduced early postoperative hyphema.

4.
J Clin Med ; 12(22)2023 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-38002619

RESUMO

This study aims to compare the surgical efficacy and safety of the Tanito microhook trabeculotomy (TMH-CE) and iStent inject W (Inject-CE) when performed in combination with cataract surgery on the eyes of glaucoma patients. A total of 78 glaucomatous eyes from 39 participants were retrospectively analyzed. Intraocular pressure (IOP), the number of antiglaucoma medications, best-corrected visual acuity (BCVA), anterior chamber flare (ACF), and corneal endothelial cell density (CECD) were all evaluated preoperatively and at multiple postoperative time points. The preoperative IOP was significantly higher in the TMH-CE (19.6 ± 6.7 mmHg) than in the Inject-CE (15.7 ± 3.8 mmHg) (p < 0.0001). At the 12-month follow-up, reductions in IOP and the number of medications were more pronounced in the TMH-CE (6.6 mmHg, 27.6% and -1.1, respectively) group than Inject-CE (2.7 mmHg, 12.4% and -0.7, respectively) (p < 0.0001 and p = 0.0034), while the IOP and medication-number levels were identical between TMH-CE (13.0 ± 3.3 mmHg and 1.3 ± 0.9, respectively) and Inject-CE (12.9 ± 2.6 mmHg and 1.9 ± 0.9, respectively) (p = 0.88 and p > 0.99, respectively). The TMH-CE group exhibited a higher ACF, a higher frequency of layered hyphema, and a greater anterior chamber floating red blood cells score in the early postoperative periods. Despite these differences, the changes in BCVA, ACF, and CECD were equivalent between the two groups in later follow-up periods. TMH-CE provides a more significant IOP reduction and medication-number reduction compared to Inject-CE, while Inject-CE shows quicker BCVA recovery. This study provides valuable insights for ophthalmologists choosing the most suitable surgical approach for glaucoma and cataract patients.

5.
Cureus ; 15(10): e47356, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38022219

RESUMO

We report a case of PreserFlo MicroShunt (PFM) dislocation following a postsurgical needling procedure. A 58-year-old woman underwent PFM implantation for exfoliation glaucoma in her left eye (OS). There were no intraoperative complications. Preoperatively, her best-corrected visual acuity (BCVA) was 0.6, and her intraocular pressure (IOP) was 25 mmHg with three antiglaucoma medications in the OS. On postoperative day 21, the IOP was 21 mmHg OS, and the filtration bleb had shrunk. A needling procedure was performed using a sharp 26-gauge needle to lower the IOP. On postoperative day 29, the BCVA was 0.02, and the IOP was 60 mmHg OS. Gonioscopy revealed no device tip in the anterior chamber, and peripheral anterior synechia was observed at the site of PFM insertion. Anterior segment optical coherence tomography showed a dislocated device in the subconjunctival space. On postoperative day 35, the dislocated PFM was removed, and a new device was inserted. Following the reoperation, no further complications were observed, and bleb formation was obtained. In conclusion, like other glaucoma filtering surgeries, PFM may require postsurgical needling procedures. Needling procedures may cause PFM dislocation and IOP rise, resulting in the requirement for further IOP-reducing procedures.

6.
BMC Ophthalmol ; 23(1): 206, 2023 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-37165322

RESUMO

BACKGROUND: We report a case with two connected stents ejected simultaneously during an iStent inject W surgery, a modified second-generation iStent Trabecular Micro-Bypass System. CASE PRESENTATION: A 57-year-old woman with primary open-angle glaucoma underwent a combined cataract and iStent inject W surgery in her left eye. After the trabecular meshwork/Schlemm's canal was pierced by the trocar of injector, the delivery button was pressed a first time, but the stent was not ejected. After the button was pressed a second time, connected two stents were ejected. After removing the dislocated stents from the anterior chamber, two stents were implanted into the desired places using another injector. Except for mild hyphema, no postoperative complication occurred. Stereomicroscopic observation showed that the two stents were connected by a broken trocar shaft. An X-ray showed that the trocar shaft was broken at the part referred to as the "sprayed trocar". Scanning electron microscopy showed that the surface features of the broken trocar and trocar tip represented tensile failure. CONCLUSIONS: Although rare, considering that the damage was seen at the structurally weak part (i.e., sprayed trocar), the same phenomenon can happen. For patient safety, surgeons are recommended to inspect the device when the deployment of either the first or second stent is unsuccessful during the iStent inject surgery.


Assuntos
Extração de Catarata , Catarata , Glaucoma de Ângulo Aberto , Humanos , Feminino , Pessoa de Meia-Idade , Glaucoma de Ângulo Aberto/cirurgia , Glaucoma de Ângulo Aberto/complicações , Malha Trabecular , Catarata/complicações , Stents , Pressão Intraocular
7.
Am J Ophthalmol Case Rep ; 30: 101841, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37077294

RESUMO

Purpose: The Zepto nano-pulse precision capsulotomy is a novel device for capsulorhexis formation during cataract surgery. Few complications or challenges have been reported while using this device. The purpose of this paper is to highlight two intra-operative challenges that were encountered while using the Zepto device. Observations: CASE 1 - A 65-year-old with advanced primary open angle glaucoma (POAG) and an in situ Ahmed Glaucoma Valve located in the anterior chamber. During a planned phacoemulsification procedure, the tube became trapped between the suction cup of the Zepto device and the lens, resulting in a sudden complete collapse of the anterior chamber. The procedure was completed after appropriate interventions. On post-operative day 1 Descemet folds were visible, and corneal endothelial cell density was reduced from 2101 cells/cm2 preoperatively to 1355 cells/cm2 at 19 months postoperatively. CASE 2 - A 66-year-old female with secondary cataract from chronic inflammation post trabeculectomy for advanced POAG. During a planned phacoemulsification procedure, despite synechialysis for the 360° posterior synechiae, the iris tissue was sucked into the suction cup of the Zepto device and became incarcerated over the lens. The procedure was completed after a successful intervention. Conclusions and importance: Although not previously reported and possibly rare, intra-operative complications may be encountered while using the Zepto device, particularly in complex cataract cases. For the patient's safety and satisfactory post-operative and refractive outcomes, caution must be applied.

8.
Am J Ophthalmol Case Rep ; 27: 101595, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35651595

RESUMO

Purpose: Hallermann-Streiff syndrome (HSS) is a rare congenital disorder characterized by dyscephaly, hypotrichosis, microphthalmia, dental anomalies, and cutaneous atrophy. Because of the presence of a characteristic facial appearance, severe visual disturbance, and/or upper airway obstruction, most patients with HSS are diagnosed as having a congenital anomaly as a newborn or early in life. We report a case of HSS that was first recognized when the patient was in her seventh decade of life. Observations: A 68-year-old woman presented to our department for decreased vision in both eyes (OU). Her ocular medical history included "ocular injections" in her left eye (OS); laser iridotomies OU, cataract surgery OS, and removal of corneal opacity OU; she did not have a remarkable systemic medical history. At the initial visit to our department, her best-corrected visual acuity was 0.5 in her right eye (OD) and 0.1 OS with +4.0-diopter hyperopic correction OU, corneal opacity due to calcification OU, a shallow anterior chamber and iridotrabecular contact OD were observed. During the surgical intervention OD, the surgeon recognized a "blue sclera," and the physicians initially suspected an underlying systemic malformation. Although mild, she presented with a thin beak-like nose and receding chin. In combination with the ocular features, the proportionate short stature, and a characteristic facial appearance, she was diagnosed with HSS. Conclusions and importance: Patients with HSS who had no clinically significant cosmetic, visual, and respiratory problems early in life may not be recognized as having HSS. The presence of corneal opacity, short axial length, and a blue sclera recognized by ophthalmologists can lead to the correct diagnosis of this congenital disorder.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA