Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Transl Vis Sci Technol ; 9(5): 1, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32821473

RESUMO

Purpose: High-resolution imaging of the critical anatomic structures of the eye, especially of the anterior chamber, in vivo, remains a challenge, even with currently available state-of-the-art medical imaging techniques. This study aims for the noninvasive and noncontact sequential imaging of the iridocorneal angle, especially the trabecular meshwork (TM) and the cornea of the eye in high-resolution using a newly developed imaging platform. Methods: Bessel beam scanned light sheet fluorescence microscopy is used to attain high-resolution images of the TM. The ability of the Bessel beam to self-reconstruct around obstacles increases the image contrast at the TM region inside eye by reducing scattering and shadow artifacts. With minimal modifications, the excitation arm of the developed imaging system is adapted for noncontact, high-resolution corneal imaging. Results: High-resolution images of the TM structures and cellular-level corneal structures are obtained in ex vivo porcine eyes, and subsequently in New Zealand white rabbit, in vivo. The spatial resolution of the developed system is 2.19 µm and has a noncontact working distance of 20 mm. Conclusions: A high-resolution imaging platform for noncontact sequential imaging of the TM and the cornea of the eye is developed. This imaging system is expected to be of potential interest in the evaluation and diagnosis of glaucoma and corneal diseases. Translational Relevance: The developed prototype offers the plausibility of in vivo, noncontact, and high-resolution imaging of the iridocorneal angle and cornea of the eye that will aid clinicians in diagnosing open-angle glaucoma and corneal diseases better.


Assuntos
Córnea , Glaucoma , Animais , Câmara Anterior , Córnea/diagnóstico por imagem , Microscopia de Fluorescência , Coelhos , Suínos , Malha Trabecular
2.
Nanotechnology ; 31(27): 275403, 2020 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-32176870

RESUMO

Modified hybrid structures of TiO2 nanotubes (TONT), p-Al doped TONT/n-TONT with an additional overlayer of alumina, are constructed to achieve 99.57% photodegradation of the stable organic pollutant methylene blue (MB) within 180 min, a degradation rate 17 times higher than pure TONTs. The anodization at three different temperatures 2, 28 and 40 °C followed by impregnation of Al is used for their preparation. The analyses of structure, chemical composition and morphology are completed using x-ray diffraction, x-ray photoelectron spectroscopy (XPS) and high resolution transmission microscopy, respectively, Rutherford back scattering and field emission scanning electron microscopy confirm the formation of the hybrid structure. This structure exhibits the highest photodegradation rate with TONT based catalysts to date for MB blue, by enhancing the electron-hole separation, the absorption of visible photons and the adsorption sites for the pollutant. The optical data coupled with valence band XPS is used for elucidating the energy band structure of the p-n junctions and to gain insight into the effect of the junction mechanism on photoactivity. The rectification ratios of the impregnated p-n junctions, determined by current-voltage measurements, are found to vary from 102 to 106.

3.
Rev Sci Instrum ; 86(9): 093702, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26429443

RESUMO

Non-contact imaging techniques are preferred in ophthalmology. Corneal disease is one of the leading causes of blindness worldwide, and a possible way of detection is by analyzing the shape and optical quality of the cornea. Here, a simple and cost-effective, non-contact optical probe system is proposed and illustrated. The probe possesses high spatial resolutions and is non-dependent on coupling medium, which are significant for a clinician and patient friendly investigation. These parameters are crucial, when considering an imaging system for the objective diagnosis and management of corneal diseases. The imaging of the cornea is performed on ex vivo porcine samples and subsequently on small laboratory animals, in vivo. The clinical significance of the proposed study is validated by performing imaging of the New Zealand white rabbit's cornea infected with Pseudomonas.


Assuntos
Doenças da Córnea/diagnóstico , Tomografia de Coerência Óptica/instrumentação , Animais , Suínos
4.
Rev Sci Instrum ; 85(6): 066105, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24985869

RESUMO

Noninvasive medical imaging techniques have high potential in the field of ocular imaging research. Angle closure glaucoma is a major disease causing blindness and a possible way of detection is the examination of the anterior chamber angle in eyes. Here, a simple optical method for the evaluation of angle-closure glaucoma is proposed and illustrated. The light propagation from the region associated with the iridocorneal angle to the exterior of eye is considered analytically. The design of the gel assisted probe prototype is carried out and the imaging of iridocorneal angle is performed on an eye model.


Assuntos
Córnea/patologia , Glaucoma de Ângulo Fechado/diagnóstico , Glaucoma de Ângulo Fechado/patologia , Iris/patologia , Imagem Óptica , Humanos , Imagem Óptica/instrumentação , Imagem Óptica/métodos
5.
Appl Opt ; 53(6): 1083-8, 2014 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-24663305

RESUMO

Microlens-ended fibers could find great usefulness in future biomedical applications, particularly in endoscopic imaging applications. In this context, this paper focuses on microlens-attached specialty optical fibers such as imaging fiber that can be used for probe imaging applications. Stand-alone self-aligned polymer microlenses have been fabricated by microcompression molding. The fabrication parameters have been optimized for different materials, such as poly(methyl methacrylate) (PMMA), polycarbonate (PC Lexan 123R), Zeonor 1060R (ZNR), and Topas COC. A comparison study of the focusing and spatial resolution of the fabricated lenses is performed prior to employing them for fiber-optic fluorescence imaging applications.


Assuntos
Tecnologia de Fibra Óptica/instrumentação , Miniaturização/instrumentação , Modelos Teóricos , Fotografação/instrumentação , Plásticos/química , Simulação por Computador , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Temperatura Alta , Luz , Espalhamento de Radiação
6.
Opt Lett ; 37(10): 1607-9, 2012 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-22627511

RESUMO

We demonstrate a novel multifunctional optical system that is capable of trapping, imaging, position sensing, and fluorescence detection of micrometer-sized fluorescent test particles using hollow-core photonic crystal fiber (HC-PCF). This multifunctional optical system for trapping, position sensing, and fluorescent detection is designed such that a near-IR laser light is used to create an optical trap across a liquid-filled HC-PCF, and a 473 nm laser is employed as a source for fluorescence excitation. This proposed system and the obtained results are expected to significantly enable an efficient integrated trapping platform employing HC-PCF for diagnostic biomedical applications.


Assuntos
Corantes Fluorescentes/análise , Corantes Fluorescentes/química , Fibras Ópticas , Pinças Ópticas , Microesferas , Espectrometria de Fluorescência
7.
Rev Sci Instrum ; 82(4): 043110, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21528998

RESUMO

Microlens-ended fibers, which have found tremendous interest in the recent past, find potential biomedical applications, in particular, in endoscopic imaging. The work presented in this paper focuses on the stand-alone microlenses along with custom-fabricated specialty optical fiber, such as imaging fiber, for probe imaging applications. Stand-alone self-aligned microlenses have been fabricated employing microcompression molding and then attached at the end facet of imaging fiber. A detailed characterization of the fabricated microlens is carried and it demonstrates appropriate focusing ability, high fluorescence collection efficiency and imaging ability for biomedical applications. The surface roughness of the microlens is found to be 25 nm with a minimum spot size of 38 µm. The probe imaging system is found to be able to image the fluorescence microspheres of 10 µm size. The collection efficiency of the fiber probe with lens found to be enhanced by three times approximately.


Assuntos
Lentes , Microscopia de Fluorescência/instrumentação , Fibras Ópticas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA