Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Cardiol Cases ; 10(3): 91-93, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30546515

RESUMO

A 79-year-old male, with a history of percutaneous coronary intervention (PCI), was referred to our cardiovascular department for a detailed examination of blackout caused by sinus arrest only during meals. Ultrasound echocardiography showed normal cardiac contraction with no asynergy, irrespective of the remaining stenotic coronary lesion. An electrophysiological study revealed deteriorated atrioventricular nodal conduction at a Wenckebach point of 70 beats per minute. However, sinus node function was normal as demonstrated by a sinus node recovery time of 1369 ms. Coronary angiography showed triple-vessel disease including the remaining stenotic coronary lesion, and a PCI was performed on the right coronary artery. Nevertheless, sinus arrest during meals was unchanged. Swallow syncope was partially improved by dietary modification; however, pacemaker implantation (PMI) was performed eventually, and the patient became asymptomatic after PMI. .

2.
Heart Vessels ; 29(4): 560-2, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24005764

RESUMO

A 77-year-old man was referred to our cardiovascular department for detailed examination after abnormal electrocardiography findings were obtained during a preoperative cataract surgery workup. Ultrasound echocardiography (UCG) and computed tomography (CT) revealed evidence of previous myocardial infarction with anteroseptal akinesis and a left ventricular (LV) thrombus (14 × 12 mm). Dabigatran (220 mg/day) was prescribed as an outpatient treatment, and the disappearance of the LV thrombus was confirmed by UCG and CT 27 days after dabigatran initiation. No thromboembolism occurred between treatment initiation and thrombus resolution. Our results indicate that dabigatran has thrombolytic action on an acute pre-existing intracardiac thrombus.


Assuntos
Benzimidazóis/uso terapêutico , Fibrinolíticos/uso terapêutico , Cardiopatias/tratamento farmacológico , Ventrículos do Coração/efeitos dos fármacos , Terapia Trombolítica , Trombose/tratamento farmacológico , beta-Alanina/análogos & derivados , Idoso , Dabigatrana , Cardiopatias/diagnóstico , Ventrículos do Coração/diagnóstico por imagem , Humanos , Achados Incidentais , Masculino , Valor Preditivo dos Testes , Trombose/diagnóstico , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Ultrassonografia , beta-Alanina/uso terapêutico
3.
J Cardiol Cases ; 8(2): e81-e84, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30546749

RESUMO

An 80-year-old man, who had dilated cardiomyopathy with right ventricular (RV) dilatation, underwent implantable cardioverter defibrillator (ICD) implantation for advanced atrioventricular block and primary prevention of sudden cardiac death. Tined and screw-in leads were placed on the right atrial appendage and RV apex, respectively. Ventricular pacing inhibition was detected after surgery due to oversensing by diaphragmatic myopotential occurring only during deep inspiration. We performed re-surgery and switched the screw-in lead for a tined lead. The diaphragmatic myopotential decreased, thereby improving oversensing by diaphragmatic myopotential and ventricular pacing inhibition. It might be beneficial to use a tined lead when placing the ventricular lead at the RV apex for implantation of a pacemaker or ICD if oversensing of diaphragmatic myopotential is observed using a screw-in lead. .

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA