Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
BMJ Open Ophthalmol ; 7(1)2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36799023

RESUMO

OBJECTIVE: To evaluate the intraocular pressure (IOP)-lowering effect based on the number of ingredients and survival rate due to adverse reactions of brinzolamide (1%)/brimonidine (0.1%) fixed combination (BBFC). METHODS AND ANALYSIS: Among 424 patients newly administered BBFC from June 2020 to May 2021, 406 were retrospectively evaluated for adverse reactions and 299 were evaluated for the IOP-lowering effect of BBFC. Among those evaluated for IOP, group A (n=86) included patients whose treatment was changed to BBFC from other two ingredients, Group B (n=90) included patients who added one ingredient by switching to BBFC, and group C (n=123) included patients who added BBFC in addition to other drugs. RESULTS: The mean IOP (mm Hg) at BBFC initiation and at 3, 6 and 12 months after BBFC initiation was 14.1, 14.0, 14.3 and 13.8 in group A, 15.9, 14.4, 13.8 and 14.5 in group B and 17.2, 14.0, 14.1 and 14.9 in group C, respectively. Group A showed no significant difference in mean IOP from baseline to any time point after BBFC initiation, whereas groups B and C showed significant IOP reductions at all time points. Seventy-three (18%) patients discontinued treatment due to adverse reactions. The survival rate was 72% at 12 months after the start of BBFC when discontinuation due to adverse reactions was defined as failure. CONCLUSION: Using BBFC, sustained IOP or decreasing IOP were observed depending on the number of ingredients. Drop-outs due to the adverse reactions should also be given attention.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Hipertensão Ocular , Humanos , Tartarato de Brimonidina/efeitos adversos , Estudos Retrospectivos , Glaucoma de Ângulo Aberto/tratamento farmacológico , Hipertensão Ocular/tratamento farmacológico , Anti-Hipertensivos/efeitos adversos , Combinação de Medicamentos , Glaucoma/tratamento farmacológico
2.
Eye Vis (Lond) ; 8(1): 25, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34193284

RESUMO

BACKGROUND: This study investigated the agreement between a new rebound tonometer, IC200, and IcarePRO and Goldmann applanation tonometry (GAT). METHODS: This was a prospective cross-sectional study. We measured the intraocular pressure (IOP) in 145 eyes of 145 glaucoma patients in the sitting position using GAT, IcarePRO, and IC200. IcarePRO and IC200 measurements were also obtained in the supine position. IC200 measurement was performed using two modes: single six (IC200-single) and automatic (IC200-continuous) six-measurements mode. RESULTS: All tonometers provided high reproducibility in both positions (all intraclass correlation coefficients > 0.90), although it was highest with GAT, followed by IC200-continuous and IC200-single and then IcarePRO. In the sitting position, the mean (± SD) IOPs of GAT, IcarePRO, IC200-single, and IC200-continuous were 14.5 ± 2.9 mmHg, 13.3 ± 3.2 mmHg, 11.6 ± 3.2 mmHg, and 11.5 ± 3.2 mmHg, respectively. IOPs measured with IcarePRO or IC200 were significantly lower than those with GAT, particularly in patients with low IOP. IOPs measured with all tonometers were significantly elevated in the supine position as compared with the sitting position, but this difference was significantly greater with IC200-single and IC200-continuous compared with IcarePRO. IOP elevation was significant in eyes without bleb versus those with bleb, but this finding was not observed when IOP was measured with IcarePRO. The IOPs of the single and continuous modes of IC200 were interchangeable in both positions. CONCLUSIONS: GAT, IcarePRO, and IC200 had sufficiently high reproducibility, but measurements with IcarePRO may not be accurate in the supine position. Elevation of IOP in the supine position, especially in eyes with bleb, was more sensitively captured with IC200 than with IcarePRO. TRIAL REGISTRATION: Japan Clinical Trials Register, No. UMIN000039982 .

3.
BMJ Open Ophthalmol ; 5(1): e000538, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32818152

RESUMO

OBJECTIVE: We investigated the detailed time course of conjunctival hyperemia induced by omidenepag isopropyl ophthalmic solution 0.002% (omidenepag), a selective prostaglandin E2 receptor 2 agonist. METHODS AND ANALYSIS: We recruited 34 healthy subjects and administered omidenepag in the right eye and ripasudil 0.4% in the left eye. We evaluated conjunctival hyperemia using slit-lamp photography at baseline and after 15, 30, 60, 120, 180 and 360 min. The conjunctival hyperemia score was graded by three independent observers using a scale from 0 (none) to 3 (severe). We also evaluated conjunctival hyperemia by the pixel coverage of conjunctival blood vessels (per cent coverage) determined using a conjunctival hyperemia-analysing software. RESULTS: In omidenepag, the conjunctival hyperemia score and per cent coverage peaked at both 30 min (mean score±SD: 1.57±0.67 and 11.90%±3.66%, respectively) and then gradually decreased at 60 min (10.79%±3.32%) and 120 min (1.10±0.52) when they reached a level that was not significantly different from the baseline values. For ripasudil 0.4%, the peak time of the conjunctival hyperemia score and per cent coverage were both at 15 min (score: 2.42±0.54 and 15.26%±3.38%). The degree of conjunctival hyperemia was significantly higher for ripasudil 0.4% than that for omidenepag from 15 to 30 min in both the conjunctival hyperemia score and per cent coverage (p<0.007 by Bonferroni correction). CONCLUSION: Conjunctival hyperemia induced by omidenepag gradually peaks to moderate severity, though weaker compared with that induced by ripasudil 0.4%, and subsides relatively quickly.

4.
Optom Vis Sci ; 97(2): 128-133, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-32011586

RESUMO

SIGNIFICANCE: This study is the first to show that the manual upper eyelid elevation (manual UEE) that is commonly used to prevent disruption of the IOP measurement due to blinking or upper eyelid contact with the tip of the tonometer does not affect the IOP values. PURPOSE: We investigated whether manual UEE affects the IOP readings using three rebound tonometers (Icare TA01i, Icare PRO, and Icare ic100) and Goldmann applanation tonometry (GAT). METHODS: One eye was measured for 101 patients (56 eyes of primary open-angle glaucoma patients and 45 healthy subjects). The IOPs were measured without and with manual UEE. Each IOP was measured twice; the measurement order using the tonometers was randomly selected. In addition, palpebral fissure height (distance between the upper and lower eyelids) was measured. RESULTS: The IOPs without manual UEE were 12.1 ± 2.9, 13.3 ± 2.7, 11.7 ± 2.9, and 16.0 ± 3.2 mmHg (Icare TA01i, Icare PRO, Icare ic100, and GAT), and those with manual UEE were 12.3 ± 3.0, 13.3 ± 2.8, 11.7 ± 2.9, and 16.0 ± 3.3, respectively. No significant difference was found between the IOP without and with manual UEE (IOP difference; all, P > .50; paired t test). Multiple linear regression analyses revealed that palpebral fissure height did not affect IOP difference for any of the tonometers. CONCLUSIONS: Simple manual UEE when measuring the IOP has little effect on the IOP obtained using all current rebound tonometers and GAT.


Assuntos
Pálpebras/fisiopatologia , Glaucoma de Ângulo Aberto/fisiopatologia , Pressão Intraocular/fisiologia , Tonometria Ocular/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA