Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 93(8): 085005, 2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-36050076

RESUMO

The ultraviolet C rays (UVC, wavelength λ = 100-280 nm) light generated by a Hg lamp (λ = 254 nm) and UVC light-emitting diodes (LEDs, λ = 265 and 275 nm) was detected using a fluorescence-enhanced silicon photodiode (FE-PD). Ce-doped yttrium aluminum garnet (YAG:Ce), YAG:Pr, YAG:Eu, YAG:Tb, YAG:Cr, Al2O3:Ti, Al2O3:Cr, MgAl2O4:Ti, MgAl2O4:Cr, MgAl2O4:Mn, and commercial fluorescent acrylic resins were tested as phosphor sources to enhance the output signal intensity of the FE-PD irradiated with UVC light. The resulting output signal intensity increased linearly with the UVC light strength, which was adjusted by raising the input current of the UVC LEDs from 0 to 40 mA. The sensitivity of the fabricated UVC detectors, assessed based on the calibration curve slope, varied depending on the phosphor materials. The phosphors effectively enhanced the output signal intensity of the FE-PD, which was up to six times greater than that of the visible and near infrared Si-PD without phosphors; the stronger output signal intensity was achieved using YAG:Tb, YAG:Cr, and a red fluorescent acrylic resin. The visible light emitted by phosphors under UVC irradiation is useful for detecting UVC light by the eye when using FE-PD.

2.
Dent Mater J ; 40(6): 1338-1344, 2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-33828002

RESUMO

The purpose of this study was to evaluate the application of fiberglass reinforcement method in thermoplastic mouthguard materials to improve flexural properties and adhesive strength. Commonly used two types of commercial mouth guard materials (ethylene-vinyl acetate copolymer-based and polyolefin-based) were reinforced with glass fiber clothes by two-step hot press. Flexural strength and adhesive strength with each base material were examine via three-point bending test and delamination test, respectively. Ethylene-vinyl acetate copolymer-based fiberglass-reinforced material has significantly greater adhesive strength with base material and improvement of flexural properties compared with polyolefin-based material. These results suggest that flexural properties of both conventional commercial mouthguard materials were improved when the glass-fiber-reinforced method was applied to reinforce mouthguard materials, and more, ethylene-vinyl acetate copolymer was more desirable for the base material.


Assuntos
Resistência à Flexão , Protetores Bucais , Vidro , Teste de Materiais , Maleabilidade , Estresse Mecânico
3.
Dent Mater J ; 36(6): 731-739, 2017 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-28652553

RESUMO

The purpose was to describe a novel simple experimental model of injured teeth for developing dental trauma splints (DTS), and to test various splints by combining use of this model and the Periotest® device. Rubber O-rings and spring washers were used to simulate and modify injured tooth mobility. Splinting effects were assessed among three kinds of DTS, including a composite splint and two wire-composite splints (1: rectangular orthodontic wire 0.533×0.635 mm, 2: cobalt-chromium alloy wire Φ0.9 mm). The Periotest values were measured three times for each tooth before and after splint insertion. The splinting effect was defined as the change in tooth mobility. Splinting effects significantly increased in the order wire-composite splint 1

Assuntos
Planejamento de Prótese Dentária , Contenções Periodontais , Traumatismos Dentários/terapia , Ligas de Cromo , Análise do Estresse Dentário/instrumentação , Humanos , Modelos Dentários , Modelos Teóricos , Fios Ortodônticos , Maleabilidade , Reprodutibilidade dos Testes , Mobilidade Dentária/prevenção & controle
4.
J Dent Sci ; 12(3): 308-310, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30895067

RESUMO

The present study evaluated the flexural properties of a new temporary splint material, G-Fix, for use in dental trauma splints in comparison with other resin materials. Four types of resin materials were considered in the present study: MI Flow II, light-cured composite resin (MI); G-Fix, light-cured resin for splinting teeth (GF); Super-Bond C&B, adhesive resin cement (SB); and Unifast III, self-cured methyl-methacrylate resin (UF). The flexural properties of these four materials were tested according to ISO 4049. The flexural strength significantly increased in the order of UF (64.9 MPa) < SB (76.5 MPa) < GF (94.3 MPa) < MI (161.2 MPa). The elastic modulus significantly increased in the order of UF (2.11 GPa) ≒ SB (2.23 GPa) < GF (2.62 GPa) < MI (7.39 GPa). A splint made of GF may be more flexible than a composite splint, which is categorized as a rigid splint.

5.
Dent Mater J ; 35(6): 962, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27904091

RESUMO

The purposes of this study were to examine the shock absorption capability of addition-cured silicone denture relining materials and the bonding strength of addition-cured silicone denture relining materials and a commercial mouthguard material to determine its applicability to mouthguard adjustment. Two addition-cured silicone denture relining materials were selected as test materials. The impact test was applied by a free-falling steel ball. On the other hand, bonding strength was determined by a delamination test. After prepared surface treatments using acrylic resin on MG sheet surface, 2 types of addition-cured silicone denture relining materials were glued to MG surface. The peak intensity, the time to peak intensity from the onset of the transmitted force and bonding strength were statistically analyzed using ANOVA and Tukey's honest significant difference post hoc test (p<0.05). These results suggest that the silicone denture relining materials could be clinically applicable as a mouthguard adjustment material.


Assuntos
Reembasadores de Dentadura , Reembasamento de Dentadura , Resinas Acrílicas , Colagem Dentária , Bases de Dentadura , Teste de Materiais , Silicones , Propriedades de Superfície
6.
Dent Mater J ; 35(4): 635-43, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27477230

RESUMO

The purposes of this study were to examine the shock absorption capability of addition-cured silicone denture relining materials and the bonding strength of addition-cured silicone denture relining materials and a commercial mouthguard material to determine its applicability to mouthguard adjustment. Two addition-cured silicone denture relining materials and eleven commercial mouthguard materials were selected as test materials. The impact test was applied by a free-falling steel ball. On the other hand, bonding strength was determined by a delamination test. After prepared surface treatments using acrylic resin on MG sheet surface, 2 types of addition-cured silicone denture relining materials were glued to MG surface. The peak intensity, the time to peak intensity from the onset of the transmitted force and bonding strength were statistically analyzed using ANOVA and Tukey's honest significant difference post hoc test (p<0.05). These results suggest that the silicone denture relining materials could be clinically applicable as a mouthguard adjustment material.


Assuntos
Reembasadores de Dentadura , Reembasamento de Dentadura , Silicones , Resinas Acrílicas , Colagem Dentária , Bases de Dentadura , Humanos , Teste de Materiais , Propriedades de Superfície
7.
Dent Traumatol ; 32(6): 474-479, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27126657

RESUMO

PURPOSE: The purpose of this study was to investigate the shock absorption capability of commercial thermoforming mouthguard sheet materials. MATERIALS AND METHODS: Twelve commercial thermoforming mouthguard sheet materials were selected as test materials. The impact test was applied by a free-falling steel ball. When impact forces of approximately 660 N were applied on the commercial thermoforming mouthguard materials, the peak intensities were measured using the load cell sensor. The peak intensity and the time to peak intensity from the onset of the transmitted force were statistically analyzed using one-way anova and Tukey's honest significant difference post hoc test (P < 0.05). RESULTS: Statistical analysis for the peak intensity and the time to peak intensity from the onset of the transmitted force revealed significant differences among the thirteen groups including the control. The peak intensity of the polystyrene-polyolefin copolymer-based material was lower than the peak intensity of the EVA-, polyolefin-based material. Polyolefin-based materials had a tendency of a long duration to reach peak intensity from the onset of the transmitted force. CONCLUSION: These results suggest that all of the commercially available mouthguard sheet materials had high shock-absorbing capabilities.


Assuntos
Desenho de Equipamento , Protetores Bucais , Teste de Materiais , Polivinil , Aço
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA