Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Molecules ; 28(10)2023 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-37241899

RESUMO

Bleomycin, which is widely used as an antitumor agent, possesses serious adverse effects such as pulmonary toxicity. Local nanoaerosol deposition for lung cancer treatment is a promising alternative to drug delivery to lung lesions. The aim of this work is to test the hypothesis that bleomycin nanoaerosol can be effectively used to treat multiple lung metastases. To obtain bleomycin nanoaerosol, an aerosol generator based on electrospray of a solution of a nonvolatile substance with gas-phase neutralization of charged aerosol particles was used. Lung metastases in murine Lewis lung carcinoma and B16 melanoma animal models were counted. The effect of inhaled bleomycin nanoparticles on the number and volume of metastases, as well as pulmonary side effects, was investigated. Using a mouse exposure chamber, the dose-dependent effect of inhaled bleomycin on tumor volume was evaluated in comparison with intraperitoneal administration. Bleomycin nanoaerosol reduced the volume of metastases and produced a higher antitumor effect at much lower doses. It has been established that long-term exposure to nanoaerosol with a low dose of bleomycin is capable of suppressing cancer cell growth. The treatment was well tolerated. In the lungs, minor changes were found in the form of focal-diffuse infiltration of the lung parenchyma.


Assuntos
Carcinoma , Neoplasias Pulmonares , Animais , Camundongos , Bleomicina/toxicidade , Aerossóis e Gotículas Respiratórios , Pulmão , Neoplasias Pulmonares/tratamento farmacológico , Neoplasias Pulmonares/patologia , Carcinoma/patologia
2.
Biochemistry (Mosc) ; 87(11): 1268-1276, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36509724

RESUMO

It has recently been shown that combination of arrestin and recoverin can serve as an effective urinary biomarker for renal cell carcinoma with sensitivity and specificity of over 92%. In this work, we studied the possibility of detecting these antigens in the urine in other urological oncological diseases - bladder cancer (BC) and prostate cancer (PCa). Urine samples from 40 BC patients and 40 PCa patients were analyzed using an ultrasensitive microarray immunoassay with a detection limit of 0.1 pg/ml. It was shown that in BC the sensitivity of determining combination of arrestin with recoverin is 58% (AUC 0.76, 95% CI 0.66-0.86), while in PCa it is 60% (AUC 0.7, 95% CI 0.68-0.88). It has been established that in patients with bladder and prostate cancer who had a positive test, these antigens are not detected in 90% of cases after removal of the tumor. In the future, the obtained results could become the basis for developing new approaches for timely detection of relapses of such diseases and treatment control, as well as for the development of new diagnostic methods.


Assuntos
Neoplasias da Próstata , Neoplasias da Bexiga Urinária , Masculino , Humanos , Bexiga Urinária , Biomarcadores Tumorais , Neoplasias da Bexiga Urinária/diagnóstico , Neoplasias da Próstata/diagnóstico , Sensibilidade e Especificidade , Antígenos de Neoplasias
3.
Biochemistry (Mosc) ; 87(7): 658-666, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36154884

RESUMO

Renal cell carcinoma (RCC) is the most common urological malignancy with a high mortality and low detection rate. One of the approaches to improving its diagnostics may be the search for new non-invasive biomarkers in liquid biopsy and development of more sensitive methods for their detection. Cancer-retina antigens, which are known to be aberrantly expressed in malignant tumors, are present in liquid biopsy at extremely low concentrations. Using the developed multiplex immunoassay with a detection limit of 0.1 pg/ml, urine and serum samples of 89 patients with RCC and 50 non-cancer patients were examined for the presence of cancer-retina antigens (arrestin, recoverin, rhodopsin kinase, and transducin); the difference between the RCC and control groups was evaluated with the χ2 test. The results showed high diagnostic efficiency of a combination of arrestin and recoverin: at a threshold of 0.1 pg/ml, the sensitivity was 96%, specificity 92%, and AUC = 0.96 (95% confidence interval, 0.93-0.99). Seven days after nephrectomy, the concentration of the antigens returned to the level characteristic of the control group. Therefore, arrestin in a combination with recoverin can serve as a diagnostic non-invasive urinary biomarker of RCC.


Assuntos
Carcinoma de Células Renais , Neoplasias Renais , Arrestinas , Biomarcadores Tumorais , Carcinoma de Células Renais/diagnóstico , Carcinoma de Células Renais/patologia , Receptor Quinase 1 Acoplada a Proteína G , Humanos , Neoplasias Renais/diagnóstico , Neoplasias Renais/patologia , Recoverina , Retina , Transducina
4.
ACS Chem Neurosci ; 12(15): 2838-2850, 2021 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-34256565

RESUMO

3D models of brain organoids represent an innovative and promising tool in neuroscience studies. However, the process of neurosphere formation in vitro remains complicated and is not always very effective. This is largely due to the lack of growth factors, guidance cues, and scaffold structures commonly found in tissues. Here we present a new, simple, and efficient method for generating neurospheres using scaffolds composed of electrospun nylon fibers with a diameter of 40-180 nm, which makes them similar to the brain extracellular matrix (ECM) components. Several main advantages of the proposed method should be highlighted. The method is fast, and the biomaterial consumption is low. Also, the resulting neurospheres are attached to the scaffold nanofibers. This not only provides the experimental convenience but also suggests that the resulting organoid models can potentially demonstrate fundamentally new properties, being closer to the nervous tissue in vivo. We demonstrate the influence of the fibrous scaffold structure on the formation, morphology, and composition of neurospheres and confirm adequate functional activity of the cellular components of these spheroids. The proposed approach can be further used for drug screening, modeling of neurodevelopmental, neurodegenerative disorders, and, potentially, therapeutic tissue engineering.


Assuntos
Engenharia Tecidual , Alicerces Teciduais , Matriz Extracelular , Hipocampo , Neurônios
5.
Anal Chem ; 93(2): 1126-1134, 2021 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-33305941

RESUMO

Among the key issues that are commonly associated with the development of microarray-based assays are nonspecific binding and diffusion constraints. Here we present a novel strategy addressing both of these challenges simultaneously. The essence of the method consists in blocking the microarray surface with a blocking agent containing a perfluoroalkyl chain and a disulfide linker. The resulting surface is hydrophobic, and no immiscible liquid layer remains on it upon cyclically draining and replenishing the sample solution, ensuring an efficient mass transfer of an analyte onto a microarray. Prior to the signal detection procedure, disulfide bonds are chemically cleaved, and the perfluoroalkyl chains are removed from the microarray surface along with nonspecifically adsorbed proteins, resulting in extremely low background. Using conventional fluorescent detection, we show a 30-fold increase in signal/background ratio compared to a common epoxy-modified glass substrate. The combination of this technique with magnetic beads detection results in a simple and ultrasensitive cholera toxin (CT) immunoassay. The limit of detection (LOD) is 1 fM, which is achieved with an analyte binding time of 1 h. Efficient mass transfer provides highly sensitive detection of whole virus particles despite their low diffusion coefficient. The achieved LOD for vaccinia virus is 104 particles in 1 mL of sample. Finally, we have performed for the first time the simultaneous detection of whole virus and CT protein biomarker in a single assay. The developed technique can be used for multiplex detection of trace amounts of pathogens of various natures.


Assuntos
Toxina da Cólera/análise , Cistina/análogos & derivados , Imunofluorescência , Imunoensaio , Análise Serial de Proteínas , Toxina da Cólera/metabolismo , Cistina/síntese química , Cistina/química , Estrutura Molecular , Vaccinia virus/enzimologia , Vaccinia virus/isolamento & purificação
6.
Anal Chem ; 92(5): 4146-4153, 2020 03 03.
Artigo em Inglês | MEDLINE | ID: mdl-32023039

RESUMO

Immunoblotting is widely used for the detection of proteins using specific antibodies. We present here a new immunoblotting method, which is characterized by exceptional sensitivity, rapidness, and low consumption of antibodies. A thin conductive layer between touching hydrophilic cellulose membranes instead of polyacrylamide gel is used for the electrophoretic separation of proteins. Contrary to common Western blotting, the separation occurs in nondenaturing conditions. The membrane surface is smoothed by deposition of the cellulose layer and modified with azidophenyl groups, allowing for the photochemical in situ immobilization of proteins, which are carried out after the electrophoresis. Thus, the additional step of transferring the protein from the gel onto the membrane is eliminated. Specific protein bands are then visualized by decoration with magnetic beads. The limit of detection of interleukin IL-1ß reaches 0.3 fg or ∼104 molecules, whereas the total blotting time is about 5 min. The application of the technique is demonstrated by the detection of IL-1ß, total IgA, and IgA specific to Mycobacterium tuberculosis antigen in the exhaled breath samples, obtained from healthy subjects and tuberculosis patients.


Assuntos
Immunoblotting/métodos , Interleucina-1beta/análise , Magnetismo , Anticorpos/imunologia , Antígenos de Bactérias/imunologia , Biomarcadores/análise , Eletroforese em Gel de Poliacrilamida , Humanos , Interações Hidrofóbicas e Hidrofílicas , Imunoglobulina A/análise , Imunoglobulina A/imunologia , Interleucina-1beta/imunologia , Limite de Detecção , Mycobacterium tuberculosis/metabolismo , Tuberculose/diagnóstico
7.
Front Mol Biosci ; 7: 620687, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33659273

RESUMO

The search for new diagnostic tests for cancer or ways to improve existing tests is primarily driven by the desire to identify the disease as early as possible. In this report, we summarize the current knowledge of the most promising diagnostic protein bladder cancer (BC) markers reported over the last decade. Unfortunately, analysis of published data suggests that a reliable, highly sensitive biomarker test-system based on ELISA for detecting BC has not yet been developed. The use of more sensitive assays to detect ultra-low concentrations of biomarkers not available for ELISA, could be very beneficial. Based on the literature and pilot experimental data, we conclude that a highly sensitive immunoassay using microarrays and magnetic labels, could be an effective and cheap technique suitable for the detection of diagnostically relevant BC biomarkers.

8.
Anal Chem ; 91(17): 11209-11214, 2019 09 03.
Artigo em Inglês | MEDLINE | ID: mdl-31361475

RESUMO

We present a multiplex microarray-based assay of DNA fragments, which allows the detection of less than 10000 DNA fragments in a sample of 100 µL (corresponding to ∼0.1 fM analyte concentration) in less than 5 min. High speed and sensitivity are due to three main features of the assay. First, biotinylated adapter oligonucleotides are hybridized to the DNA fragment. Second, it is electrophoretically concentrated from the sample onto the microarray. Third, biotin labels are detected by scanning the microarray surface with streptavidin-coated magnetic beads. Prior to analysis, dsDNA fragments and genomic DNA samples were first denatured and then annealed in the presence of blocking oligonucleotides, generating ssDNA fragments capable of hybridizing with oligonucleotide probes on the microarray. The multiplexity of the assay system was demonstrated by the simultaneous detection of the genomic DNAs of three microorganisms: E. coli, B. cereus, and M. neoaurum.


Assuntos
DNA Bacteriano/genética , Análise de Sequência com Séries de Oligonucleotídeos , Bacillus cereus/genética , Escherichia coli/genética , Mycobacterium/genética
9.
J Breath Res ; 12(3): 036010, 2018 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-29504513

RESUMO

In this report we present a proof-of-principle study aimed at developing non-invasive diagnostics for pulmonary TB that are based on analyzing TB biomarkers in exhaled microdroplets of lung fluid (MLFs). Samples were collected on electrospun filters recently developed by the authors, and then tested for the presence of Mycobacterium tuberculosis (Mtb) cells, Mtb DNA, and protein biomarkers (secreted Mtb antigens and antigen-specific antibodies). The latter were detected using rapid ultra-sensitive immunochemistry methods developed in our laboratory. Neither Mtb cells (limit of detection, LOD = 1 cell) nor Mtb DNA (LOD âˆ¼ 10 CFU) were found in the MLF samples exhaled by TB patients. However, immunoglobulin A (IgA) was found in over 90% of samples from TB patients and healthy volunteers. Antigen-specific IgA were detected at higher rates in the patient samples as compared to those from nominally healthy volunteers resulting in a modest discrimination level of 72% sensitivity and 58% specificity. As such, this novel, non-invasive and fast breath diagnostic method shows promise for further development.


Assuntos
Testes Respiratórios/métodos , Expiração , Microesferas , Tuberculose Pulmonar/diagnóstico , Adulto , Anticorpos/metabolismo , Especificidade de Anticorpos , Antígenos de Bactérias/metabolismo , Biomarcadores , Líquidos Corporais/metabolismo , Estudos de Casos e Controles , Feminino , Humanos , Pulmão/metabolismo , Masculino , Pessoa de Meia-Idade , Mycobacterium tuberculosis/fisiologia , Tuberculose Pulmonar/patologia , Adulto Jovem
10.
Langmuir ; 33(32): 7829-7837, 2017 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-28727920

RESUMO

To be used as a drug, inhaled nanoaerosol particles (NAPs) must first penetrate the lipid layer on top of the lung fluid before they will be able to reach the lung epithelium. We investigated how the penetration of NAPs through a model lipid monolayer (LM) depends upon their charging level and size. It was shown that deposition of NAPs 20-200 nm in diameter and charged to the Rayleigh limit gradually increased the surface tension of a dipalmitoylphosphatidylcholine monolayer (DPPC), indicating a loss of lipid molecules from the monolayer. This phenomenon was reproduced with a variety of NAPs produced from glucose, proteins, and polymers. Transfer of the lipid material into the subphase was documented by direct visualization of lipid nanoparticles in the subphase with atomic force microscopy after deposition of glucose NAPs on a DPPC monolayer, followed by collection of the lipid nanoparticles on a mica surface. Partial restoration of tension upon storage indicates that some of the lipid may return to the monolayer. Experiments with the deposition of highly charged calibrated polystyrene nanoparticles showed that the amount of lipid removed from the surface was roughly proportional to the overall surface area of the deposited NAPs. When the number of charges on the NAPs was reduced from their Rayleigh level of 103-104 units to 1-10 units, no notable changes in monolayer surface tension were observed even with prolonged deposition of such NAPs. It was therefore concluded that only highly charged NAPs of a certain size acquire sufficient speed from their attraction by mirror charges to enable ballistic penetration through a lipid monolayer.

11.
Anal Chem ; 88(14): 7295-301, 2016 07 19.
Artigo em Inglês | MEDLINE | ID: mdl-27306261

RESUMO

Electrohydrodynamic spraying (or electrospaying, ES) of DNA solutions is an attractive technique for applications in mass spectrometry, in microarray fabrication, and in generation of DNA nanoaerosols. Here we report how ES affects DNA structure and evaluate possible ways to reduce DNA damage upon ES. It is shown that under any ES conditions, linear λ-phage DNA is subjected to intensive rupture producing a mixture of fragments. In addition to such fragmentation, notable reversible changes in the DNA structure were revealed by a slight increase in DNA electrophoretic mobility. The degree of fragmentation was shown to decrease with decreased DNA length and with increased flow rate through the ES capillary. Fragments shorter than 5 kbp did not show any notable damage upon ES. Both experimental data and theoretical estimations of the forces acting on DNA during ES indicate that DNA is damaged by mechanical forces, and the damage takes place in the vicinity of the Taylor cone tip, presumably due to the high shear stress or/and viscous drag forces operating there. Condensation of λ-DNA with hexamminecobalt(III) ions completely protected it from any damage upon ES.


Assuntos
Dano ao DNA , DNA/química , Bacteriófago lambda/genética , Cobalto/química , DNA/análise , Eletroforese em Gel de Ágar , Íons/química , Fenômenos Mecânicos , Microscopia de Força Atômica
12.
Anal Chem ; 86(3): 1511-7, 2014 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-24428752

RESUMO

It was demonstrated that electrospraying (ES) of solvents from a glass capillary proceeds without emission of light provided that the current is kept below a certain critical level (<100 nA at positive potential and <25 nA at negative potential for 96% ethanol; < 40 nA at positive potential for water). Though the onset of corona, as detected by the appearance of light, was always accompanied by a break in the current-voltage slope, such breaks also happened before the onset of corona, so they cannot be used as an adequate indicator of corona ignition. Of four ROS studied (hydrogen peroxide, ozone, hydroxyl radicals, and superoxide anions), only H2O2 and ozone were found to be generated at a current of 150-200 nA in detectable quantities: with a yield of 0.5-1 H2O2 molecules per electron at positive potential and 1.5-3 at negative potential. Despite the low yield of the ROS, jack bean urease was shown to be inactivated when the enzyme solution with a concentration below 20 µg/mL was electrosprayed at a current of 200 nA. Addition of 0.1 mM EDTA totally protected the activity of the electrosprayed urease.


Assuntos
Condutividade Elétrica , Espécies Reativas de Oxigênio/química , Animais , Etanol/química , Ozônio/química , Proteínas/química , Espécies Reativas de Oxigênio/análise , Água/química
13.
Anal Chem ; 86(4): 2082-9, 2014 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-24446727

RESUMO

Magnetic beads (MB) are widely used for quick and highly sensitive signal detection in microarray-based assays. However, this technique imposes stringent requirements for smoothness and adhesive properties of the surface, which most common substrates do not satisfy. We report here a new type of substrate for microarrays with a low adhesion to MB-thermally cross-linked carboxymethyl cellulose (CMC) film. This substrate can be readily fabricated on a conventional glass slide. A highly cross-linked CMC film (∼1 cross-link per monomer unit) possesses a surface smooth on a nanometer scale and a low adhesion to protein-coated MB, which partly originates from electrostatic repulsion of MB from negatively charged CMC surface. The efficiency of the CMC substrate is demonstrated hereby in fabrication of microarrays for the detection of three bacterial toxins: cholera toxin, staphylococcal enterotoxin A, and toxic shock syndrome toxin. The assay employing a primary antibodies arrayed on a CMC surface and detection of the bound bacterial toxins with a biotinylated secondary antibodies and streptavidin-coated MB resulted in a limits of detection as low as 0.1 ng/mL. The CMC-based microarrays demonstrated very high storage stability; their activity did not change after one year storage at room temperature.


Assuntos
Carboximetilcelulose Sódica/química , Nanopartículas de Magnetita/química , Análise Serial de Proteínas/métodos , Adesivos/química , Adesivos/metabolismo , Carboximetilcelulose Sódica/metabolismo , Especificidade por Substrato , Propriedades de Superfície
14.
Anal Chem ; 84(13): 5596-603, 2012 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-22724559

RESUMO

Rapid ultrasensitive detection of gastrointestinal pathogens presents a great interest for medical diagnostics and epidemiologic services. Though conventional immunochemical and polymerase chain reaction (PCR)-based methods are sensitive enough for many applications, they usually require several hours for assay, whereas as sensitive but more rapid methods are needed in many practical cases. Here, we report a new microarray-based analytical technique for simultaneous detection of five bacterial toxins: the cholera toxin, the E. coli heat-labile toxin, and three S. aureus toxins (the enterotoxins A and B and the toxic shock syndrome toxin). The assay involves three major steps: electrophoretic collection of toxins on an antibody microarray, labeling of captured antigens with secondary biotinylated antibodies, and detection of biotin labels by scanning the microarray surface with streptavidin-coated magnetic beads in a shear-flow. All the stages are performed in a single flow cell allowing application of electric and magnetic fields as well as optical detection of microarray-bound beads. Replacement of diffusion with a forced transport at all the recognition steps allows one to dramatically decrease both the limit of detection (LOD) and the assay time. We demonstrate here that application of this "active" assay technique to the detection of bacterial toxins in water samples from natural sources and in food samples (milk and meat extracts) allowed one to perform the assay in less than 10 min and to decrease the LOD to 0.1-1 pg/mL for water and to 1 pg/mL for food samples.


Assuntos
Toxinas Bacterianas/análise , Enterotoxinas/análise , Escherichia coli/isolamento & purificação , Análise Serial de Proteínas/instrumentação , Staphylococcus aureus/isolamento & purificação , Vibrio cholerae/isolamento & purificação , Animais , Anticorpos Imobilizados/imunologia , Toxinas Bacterianas/imunologia , Toxina da Cólera/análise , Toxina da Cólera/imunologia , Enterotoxinas/imunologia , Desenho de Equipamento , Escherichia coli/imunologia , Proteínas de Escherichia coli/análise , Proteínas de Escherichia coli/imunologia , Humanos , Imunoensaio/instrumentação , Limite de Detecção , Campos Magnéticos , Carne/microbiologia , Leite/microbiologia , Staphylococcus aureus/imunologia , Vibrio cholerae/imunologia , Microbiologia da Água
15.
Anal Chem ; 83(14): 5548-55, 2011 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-21630634

RESUMO

A simple, rapid, and highly effective technique for concentrating charged macromolecules is described which employs electrophoresis in a conic cell made of a dialysis membrane. The cell is partly submerged in electrolyte solution, and the level of solution slowly moves down during the process. The electric field within the cell is at its maximum in the area that is level with the surface of the external solution. This maximum value increases and its location moves downward following the decreasing level of external solution carrying downward and concentrating charged macromolecules. It has been demonstrated that proteins can be concentrated within 12-15 min by a factor of ∼100,000 with the total yield of 60-80%. Concentrated proteins can be harvested from the nanoliter-sized cul-de-sac of the conic concentrator using chemically activated magnetic beads. The presence of certain protein molecules linked to the bead's surface can be further revealed by specific reaction with a microarray of antibody molecules. Such "reversed magnetic array" format was applied to a cone-concentrated exhaled breath condensate (EBC) to reveal the presence of human immunoglobulin in the EBC and to estimate its concentration. The technique may be used for concentrating and detecting trace amounts of pathogens and toxins, in protein crystallization, and in many other applications.


Assuntos
Eletroforese/instrumentação , Proteínas/isolamento & purificação , Animais , Testes Respiratórios , Diálise/economia , Diálise/instrumentação , Eletroforese/economia , Desenho de Equipamento , Humanos , Imãs/química , Desnaturação Proteica , Reprodutibilidade dos Testes
16.
Anal Biochem ; 399(1): 125-31, 2010 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-20036208

RESUMO

The efficiency of hybridization analysis with oligonucleotide microarrays depends heavily on the method of detection. Conventional methods based on labeling nucleic acids with fluorescent, chemiluminescent, enzyme, or radioactive reporters suffer from a number of serious drawbacks which demand development of new detection techniques. Here, we report two new approaches for detection of hybridization with oligonucleotide microarrays employing magnetic beads as active labels. In the first method streptavidin-coated magnetic beads are used to discover biotin-labeled DNA molecules hybridized with arrayed oligonucleotide probes. In the second method biotin-labeled DNA molecules are bound first to the surface of magnetic beads and then hybridized with arrayed complementary strands on bead-array contacts. Using a simple low-power microscope with a dark-field illumination and a pair of complementary primers as a model hybridization system we evaluated sensitivity, speed, and cost of the new detection method and compared its performance with the detection techniques employing enzyme and fluorescent labels. It was shown that the detection of microarray-hybridized DNA with magnetic beads combines low cost with high speed and enhanced assay sensitivity, opening a new way to routine hybridization assays which do not require precise measurements of DNA concentration.


Assuntos
DNA de Plantas/química , Análise de Sequência com Séries de Oligonucleotídeos/métodos , Biotina/química , DNA de Plantas/análise , Magnetismo , Plantas Geneticamente Modificadas , Glycine max/genética , Estreptavidina/química
17.
Chem Phys Lipids ; 150(2): 217-28, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17915200

RESUMO

Chain-ordering/melting transition in a series of saturated diacylphosphatidylcholines (PCs) in aqueous dispersions have been studied experimentally (calorimetric and ultrasonic techniques) and theoretically (an Ising-like lattice model). The shape of the calorimetric curves was compared with the theoretical data and interpreted in terms of the lateral interactions and critical temperatures determined for each lipid studied. A critical chain length has been found (between 16 and 17 C-atoms per chain) which subdivides PCs into two classes with different phase behavior. In shorter lipids, the transition takes place above their critical temperatures meaning that this is an intrinsically continuous transition. In longer lipids, the transition occurs below the critical temperatures of the lipids, meaning that the transition is intrinsically discontinuous (first-order). This conclusion was supported independently by the ultrasonic relaxation sensitive to density fluctuations. Interestingly, it is this length that is the most abundant among the saturated chains in biological membranes.


Assuntos
Calorimetria/métodos , Lipídeos/química , Membranas/química , Fosfatidilcolinas/química , Ultrassonografia/métodos , Acústica , Carbono/química , Dimiristoilfosfatidilcolina/química , Interferometria/métodos , Lecitinas/química , Cristais Líquidos , Modelos Químicos , Modelos Teóricos , Método de Monte Carlo , Temperatura , Termodinâmica , Ultrassom
18.
J Membr Biol ; 215(1): 57-68, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17443385

RESUMO

A Ca(2+)-induced phase separation of palmitic acid (PA) in the membrane of azolectin unilamellar liposomes has been demonstrated with the fluorescent membrane probe nonyl acridine orange (NAO). It has been shown that NAO, whose fluorescence in liposomal membranes is quenched in a concentration-dependent way, can be used to monitor changes in the volume of lipid phase. The incorporation of PA into NAO-labeled liposomes increased fluorescence corresponding to the expansion of membrane. After subsequent addition of Ca(2+), fluorescence decreased, which indicated separation of PA/Ca(2+) complexes into distinct membrane domains. The Ca(2+)-induced phase separation of PA was further studied in relation to membrane permeabilization caused by Ca(2+) in the PA-containing liposomes. A supposition was made that the mechanism of PA/Ca(2+)-induced membrane permeabilization relates to the initial stage of Ca(2+)-induced phase separation of PA and can be considered as formation of fast-tightening lipid pores due to chemotropic phase transition in the lipid bilayer.


Assuntos
Cálcio/fisiologia , Permeabilidade da Membrana Celular/fisiologia , Membrana Celular/metabolismo , Palmitatos/metabolismo , Lipossomas Unilamelares/metabolismo , Laranja de Acridina , Fosfatidilcolinas/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA