Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Traffic Inj Prev ; 18(7): 767-773, 2017 10 03.
Artigo em Inglês | MEDLINE | ID: mdl-28448753

RESUMO

OBJECTIVE: The aim of this study is to evaluate, through a systematic review of hospital-based studies, the proportion of road traffic injuries and fatalities in sub-Saharan Africa (SSA). METHODS: In accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) and Meta-analysis of Observational Studies in Epidemiology guidelines, we searched the following electronic databases: PubMed, Embase, Africa-Wide Information, Global Health, and Web of Science. Articles were eligible if they measured proportion of road traffic injuries (RTIs) in SSA by using hospital-based studies. In addition, a reference and citation analysis was conducted as well as a data quality assessment. RESULTS: Up to 2015, there were a total of 83 hospital-based epidemiologic studies, including 310,660 trauma patients and 99,751 RTI cases, in 13 SSA countries. The median proportion of RTIs among trauma patients was 32% (4 to 91%), of which the median proportion of death for the included articles was 5% (0.3 to 41%). CONCLUSION: The number of studies evaluating RTI proportions and fatalities in SSA countries is increasing but without the exponential rise expected from World Health Organization calls for research during the Decade of Action for Road Traffic Injuries. Further research infrastructure including standardization of taxonomy, definitions, and data reporting measures, as well as funding, would allow for improved cross-country comparisons.


Assuntos
Acidentes de Trânsito/estatística & dados numéricos , Ferimentos e Lesões/epidemiologia , África Subsaariana/epidemiologia , Humanos , Estudos Observacionais como Assunto , Ferimentos e Lesões/mortalidade
2.
Sleep Disord ; 2015: 279263, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26483979

RESUMO

Objectives. To study the relationship between nocturnal periodic breathing episodes and behavioral awakenings at high altitude. Methods. Observational study. It is 6-day ascent of 4 healthy subjects from Besisahar (760 meters) to Manang (3540 meters) in Nepal in March 2012. A recording pulse oximeter was worn by each subject to measure their oxygen saturation and the presence of periodic breathing continuously through the night. An actigraph was simultaneously worn in order to determine nocturnal behavioral awakenings. There were no interventions. Results. 187-hour sleep at high altitude was analyzed, and of this, 145 hours (78%) had at least one PB event. At high altitude, 10.5% (95% CI 6.5-14.6%) of total sleep time was spent in PB while 15 out of 50 awakenings (30%, 95% CI: 18-45%) occurring at high altitudes were associated with PB (P < 0.001). Conclusions. Our data reveals a higher than expected number of behavioral awakenings associated with PB compared to what would be expected by chance. This suggests that PB likely plays a role in behavioral awakenings at high altitude.

3.
Can J Cardiol ; 31(3): 348-56, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25746024

RESUMO

BACKGROUND: The long-term effects of continuous-flow left ventricular assist device (CF-LVAD) support on trends of inflammatory markers over time are unknown. We examined the hypothesis that the levels of inflammatory markers in CF-LVAD recipients are higher than in healthy controls and that these levels increase over time with long-term CF-LVAD support. METHODS: We examined the levels of inflammatory markers longitudinally at baseline before CF-LVAD implantation and at 3, 6, and 9 months after implantation. We then compared the levels of inflammatory markers to those in a healthy control group. RESULTS: Compared with baseline values before CF-LVAD implantation, left ventricular end-diastolic diameter (LVEDd) and left ventricular end-systolic diameter (LVESd) decreased significantly at 3, 6, and 9 months after CF-LVAD implantation. Brain natriuretic peptide (BNP) levels dropped significantly after CF-LVAD implantation but did not normalize. Improvements in ejection fraction at 3, 6, and 9 months after CF-LVAD implantation did not reach significance. Monocyte chemoattractant protein-1, interferon γ-induced protein, and C-reactive protein levels were higher in the CF-LVAD recipients at each of the time points (baseline before CF-LVAD implantation and 3, 6, and 9 months after implantation) compared with levels in healthy controls. In CF-LVAD recipients, serum interleukin-8, tumour necrosis factor-α, and macrophage inflammatory protein-ß increased significantly at 9 months, and macrophage-derived chemokine increased at 6 months after CF-LVAD implantation compared with baseline. CONCLUSIONS: Despite improvements in LV dimensions and BNP levels, markers of inflammation remained higher in CF-LVAD recipients. High levels of inflammation in CF-LVAD recipients may result from heart failure preconditioning or the long-term device support, or both. Because inflammation may be detrimental to CF-LVAD recipients, future studies should determine whether inflammatory pathways are reversible.


Assuntos
Biomarcadores/sangue , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/terapia , Coração Auxiliar , Inflamação/sangue , Função Ventricular Esquerda , Adulto , Idoso , Proteína C-Reativa/metabolismo , Estudos de Casos e Controles , Quimiocina CCL2/sangue , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Interleucina-18/sangue , Interleucina-8/sangue , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Natriuréticos/sangue , Peptídeo Natriurético Encefálico/sangue , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Fator de Necrose Tumoral alfa/sangue
4.
J Crit Care ; 30(1): 217.e1-5, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25262530

RESUMO

PURPOSE: We investigated the reproducibility of passive leg raise (PLR) and fluid bolus (BOLUS) using the Non-Invasive Cardiac Output Monitor (NICOM; Cheetah Medical, Tel Aviv, Israel) for assessment of fluid responsiveness (FR) in spontaneously breathing emergency department (ED) patients. METHODS: Prospective, observational study of a convenience sample of adult ED patients receiving intravenous fluid bolus. We assessed stroke volume (SV) using NICOM and obtained results from PLR, where the head of the bed was changed from semirecumbent to supine while the patients' legs raised to 45° for 3 minutes. Fluid bolus was defined as 5 mL/kg normal saline infusion. Maximal increase in SV was recorded. Fluid responsiveness was defined as an increase of SV greater than 10% from baseline. We obtained 4 consecutive responses for each patient; PLR1, PLR2, BOLUS1 separated each by 10 minutes, and BOLUS2 initiated immediately after the end of BOLUS1. We calculated κ statistics, correlation coefficients, and odds ratios with 95% confidence interval and Bland-Altman plots. RESULTS: We enrolled 109 patients enrolled in this study. The 2 PLRs were significantly correlated (r = 0.78, P < .001) with κ = 0.46 for FR (P < .001). The 2 BOLUSES less strongly correlated (r = 0.14, P = .001) and κ = 0.06 for FR (P < .001). Patients who were responsive to PLR1 had 9.5 (3.6-25) odds of being FR for PLR2, whereas those responsive to BOLUS1 had a 1.8 (0.76-4.3) increased odds of FR for BOLUS2. CONCLUSION: In conclusion, we have found PLR as measured by the NICOM to be a promising tool for the evaluation of SV responsiveness. It was feasible for use in the ED, and the data suggest that the PLR technique may be more reproducible than the fluid bolus technique for assessing volume responsiveness.


Assuntos
Débito Cardíaco/fisiologia , Hidratação/métodos , Perna (Membro) , Posicionamento do Paciente/métodos , Respiração , Adulto , Idoso , Intervalos de Confiança , Serviço Hospitalar de Emergência , Feminino , Humanos , Remoção , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Razão de Chances , Estudos Prospectivos , Reprodutibilidade dos Testes , Cloreto de Sódio/administração & dosagem , Volume Sistólico/fisiologia , Fatores de Tempo
5.
West J Emerg Med ; 15(7): 859-71, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25493136

RESUMO

INTRODUCTION: Acute appendicitis is the most common abdominal emergency requiring emergency surgery. However, the diagnosis is often challenging and the decision to operate, observe or further work-up a patient is often unclear. The utility of clinical scoring systems (namely the Alvarado score), laboratory markers, and the development of novel markers in the diagnosis of appendicitis remains controversial. This article presents an update on the diagnostic approach to appendicitis through an evidence-based review. METHODS: We performed a broad Medline search of radiological imaging, the Alvarado score, common laboratory markers, and novel markers in patients with suspected appendicitis. RESULTS: Computed tomography (CT) is the most accurate mode of imaging for suspected cases of appendicitis, but the associated increase in radiation exposure is problematic. The Alvarado score is a clinical scoring system that is used to predict the likelihood of appendicitis based on signs, symptoms and laboratory data. It can help risk stratify patients with suspected appendicitis and potentially decrease the use of CT imaging in patients with certain Alvarado scores. White blood cell (WBC), C-reactive protein (CRP), granulocyte count and proportion of polymorphonuclear (PMN) cells are frequently elevated in patients with appendicitis, but are insufficient on their own as a diagnostic modality. When multiple markers are used in combination their diagnostic utility is greatly increased. Several novel markers have been proposed to aid in the diagnosis of appendicitis; however, while promising, most are only in the preliminary stages of being studied. CONCLUSION: While CT is the most accurate mode of imaging in suspected appendicitis, the accompanying radiation is a concern. Ultrasound may help in the diagnosis while decreasing the need for CT in certain circumstances. The Alvarado Score has good diagnostic utility at specific cutoff points. Laboratory markers have very limited diagnostic utility on their own but show promise when used in combination. Further studies are warranted for laboratory markers in combination and to validate potential novel markers.


Assuntos
Apendicite/diagnóstico , Doença Aguda , Apendicectomia , Apendicite/sangue , Apendicite/cirurgia , Biomarcadores/sangue , Técnicas de Apoio para a Decisão , Diagnóstico Diferencial , Medicina Baseada em Evidências , Humanos , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X
6.
ASAIO J ; 60(6): 657-63, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25232767

RESUMO

Although the newer continuous-flow left ventricular assist devices (CF-LVADs) provide clinical advantages over the pulsatile pumps, the effects of low pulsatility on inflammation are incompletely understood. The objective of our study was to examine the levels of inflammatory mediators in CF-LVAD recipients compared with both healthy control subjects and heart failure patients who were candidates for CF-LVAD support. Plasma levels of chemokines, cytokines, and inflammatory markers were measured in 18 CF-LVAD recipients and compared with those of 14 healthy control subjects and 14 heart failure patients who were candidates for CF-LVADs. The levels of granulocyte macrophage-colony stimulating factor, macrophage inflammatory proteins-1ß, and macrophage-derived chemokine were significantly higher in the CF-LVAD group compared with both the heart failure and the healthy control groups, whereas no significant differences were observed between the healthy control subjects and the heart failure groups. Compared with the healthy controls, C-reactive protein, interferon gamma-induced protein-10, monocyte chemotactic protein-1, and interleukin-8 levels were significantly higher in both the CF-LVAD and heart failure groups, but no significant differences were observed between the CF-LVAD recipients and the heart failure patients. Inflammatory markers were elevated in CF-LVAD recipients compared with healthy control subjects and the heart failure patients. Further studies should investigate the clinical implications of elevated levels of inflammation in CF-LVAD recipients.


Assuntos
Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Mediadores da Inflamação/sangue , Biomarcadores/sangue , Proteína C-Reativa/metabolismo , Estudos de Casos e Controles , Quimiocinas/sangue , Citocinas/sangue , Insuficiência Cardíaca/fisiopatologia , Humanos , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/sangue , Prognóstico , Volume Sistólico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA