Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(6)2023 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-36992073

RESUMO

The Timepix3 is a hybrid pixellated radiation detector consisting of a 256 px × 256 px radiation-sensitive matrix. Research has shown that it is susceptible to energy spectrum distortion due to temperature variations. This can lead to a relative measurement error of up to 35% in the tested temperature range of 10 °C to 70 °C. To overcome this issue, this study proposes a complex compensation method to reduce the error to less than 1%. The compensation method was tested with different radiation sources, focusing on energy peaks up to 100 keV. The results of the study showed that a general model for temperature distortion compensation could be established, where the error in the X-ray fluorescence spectrum of Lead (74.97 keV) was reduced from 22% to less than 2% for 60 °C after the correction was applied. The validity of the model was also verified at temperatures below 0 °C, where the relative measurement error for the Tin peak (25.27 keV) was reduced from 11.4% to 2.1% at -40 °C. The results of this study demonstrate the effectiveness of the proposed compensation method and models in significantly improving the accuracy of energy measurements. This has implications for various fields of research and industry that require accurate radiation energy measurements and cannot afford to use power for cooling or temperature stabilisation of the detector.

2.
Sensors (Basel) ; 23(4)2023 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-36850799

RESUMO

The Timepix3 readout ASIC chip is a hybrid pixelated radiation detector, designed at CERN, which contains a 256 px × 256 px matrix. Each of the 65,536 radiation-sensitive pixels can record an incoming particle, its energy deposition or time of arrival and measure them simultaneously. Since the detector is suitable for a wide range of applications from particle physics, national security and medicine to space science, it can be used in a wide range of temperatures. Until now, it has to be calibrated every time to the operating point of the application. This paper studies the possibility of energy measurement with Timepix3 equipped with a 500 m thick silicon sensor and MiniPIX readout interface in the temperatures between 10 ∘C and 70 ∘C with only one calibration. The detector has been irradiated by X-ray fluorescence photons in the energy range from 8 keV to 57 keV, and 31 keV to 81 keV photons from the 133Ba radioactive source. A deviation of 5% in apparent energy value may occur for a 10 ∘C change in temperature from the reference point, but, with the next temperature change, it can reach up to -30%. Moreover, Barium photons with an energy of 81 keV appear as deposited energy of only 55 keV at a detector temperature of 70 ∘C. An original compensation method that reduces the relative measurement error from -30% to less than 1% is presented in this paper.

3.
Sci Rep ; 12(1): 2070, 2022 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-35136116

RESUMO

Outdoor breathing trials with simulated avalanche snow are fundamental for the research of the gas exchange under avalanche snow, which supports the development of the international resuscitation guidelines. However, these studies have to face numerous problems, including unstable weather and variable snow properties. This pilot study examines a mineral material perlite as a potential snow model for studies of ventilation and gas exchange parameters. Thirteen male subjects underwent three breathing phases-into snow, wet perlite and dry perlite. The resulting trends of gas exchange parameters in all tested materials were similar and when there was a significant difference observed, the trends in the parameters for high density snow used in the study lay in between the trends in dry and wet perlite. These findings, together with its stability and accessibility year-round, make perlite a potential avalanche snow model material. Perlite seems suitable especially for simulation and preparation of breathing trials assessing gas exchange under avalanche snow, and potentially for testing of new avalanche safety equipment before their validation in real snow.The study was registered in ClinicalTrials.gov on January 22, 2018; the registration number is NCT03413878.


Assuntos
Óxido de Alumínio , Avalanche , Troca Gasosa Pulmonar/fisiologia , Respiração , Dióxido de Silício , Neve , Adulto , Reanimação Cardiopulmonar/métodos , Estudos Cross-Over , República Tcheca , Método Duplo-Cego , Humanos , Masculino , Modelos Teóricos , Projetos Piloto , Estudos Prospectivos , Treinamento por Simulação , Adulto Jovem
4.
J Org Chem ; 85(1): 248-276, 2020 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-31808692

RESUMO

A series of carba- or oxa[5]-, [6]-, [7]-, and -[19]helicene (di)thiols was prepared. The Miyazaki-Newman-Kwart rearrangement of (dimethylcarbamothioyl)oxy (oxa)helicenes in a flow reactor or nucleophilic substitution of dichloro (oxa)helicenes with alkanethiolates were used in the sulfanylation step. Despite the high temperatures employed in this key step, no conformational scrambling was observed during the asymmetric synthesis of the diastereo- and enantiopure oxahelicenes. Single-molecule conductivity of the longest oxa[19]helicene dithiol derivative was studied by the scanning tunneling microscopy break-junction method.

5.
Angew Chem Int Ed Engl ; 56(21): 5839-5843, 2017 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-28417538

RESUMO

A series of oxahelicenes composed of ortho/meta-annulated benzene/pyridine and 2H-pyran rings were synthesized on the basis of the cobalt(I)-mediated (or rhodium(I)- or nickel(0)-mediated) double, triple, or quadruple [2+2+2] cycloisomerization of branched aromatic hexa-, nona-, or dodecaynes, thus allowing the construction of 6, 9, or 12 rings in a single operation. The use of a flow reactor was found to be beneficial for the multicyclization reactions. The stereogenic centers present in some of the oligoynes steered the helical folding in such a way that the final oxa[9]-, [13]-, [17]- and [19]helicenes were obtained in both enantiomerically and diastereomerically pure form. Specifically, the oxa[19]helicenes beat the current record in the length of a helicene backbone. Single-molecule conductivity was studied by the mechanically controllable break-junction method with a pyridooxa[9]helicene.

6.
PLoS One ; 10(12): e0144332, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26666523

RESUMO

Presence of an air pocket and its size play an important role in survival of victims buried in the avalanche snow. Even small air pockets facilitate breathing. We hypothesize that the size of the air pocket significantly affects the airflow resistance and work of breathing. The aims of the study are (1) to investigate the effect of the presence of an air pocket on gas exchange and work of breathing in subjects breathing into the simulated avalanche snow and (2) to test whether it is possible to breathe with no air pocket. The prospective interventional double-blinded study involved 12 male volunteers, from which 10 completed the whole protocol. Each volunteer underwent two phases of the experiment in a random order: phase "AP"--breathing into the snow with a one-liter air pocket, and phase "NP"--breathing into the snow with no air pocket. Physiological parameters, fractions of oxygen and carbon dioxide in the airways and work of breathing expressed as pressure-time product were recorded continuously. The main finding of the study is that it is possible to breath in the avalanche snow even with no air pocket (0 L volume), but breathing under this condition is associated with significantly increased work of breathing. The significant differences were initially observed for end-tidal values of the respiratory gases (EtO2 and EtCO2) and peripheral oxygen saturation (SpO2) between AP and NP phases, whereas significant differences in inspiratory fractions occurred much later (for FIO2) or never (for FICO2). The limiting factor in no air pocket conditions is excessive increase in work of breathing that induces increase in metabolism accompanied by higher oxygen consumption and carbon dioxide production. The presence of even a small air pocket reduces significantly the work of breathing.


Assuntos
Asfixia/fisiopatologia , Avalanche , Desastres , Hipercapnia/fisiopatologia , Hipóxia/fisiopatologia , Trabalho Respiratório/fisiologia , Adulto , Asfixia/prevenção & controle , Dióxido de Carbono/fisiologia , Estudos Cross-Over , Método Duplo-Cego , Voluntários Saudáveis , Humanos , Volume de Reserva Inspiratória/fisiologia , Masculino , Monitorização Fisiológica , Oxigênio/fisiologia , Neve , Volume de Ventilação Pulmonar/fisiologia
7.
Neuro Endocrinol Lett ; 33(2): 224-35, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22592206

RESUMO

BACKGROUND: Cortisol, along with other hormones of hypothalamo-pituitary-adrenal axis, belongs to one of the main factors influencing psychological and pathognomic factors, intelligence, and memory. METHODS: The aim of our study was to review a large battery of psychological, performance, IQ and memory tests as to their relation with cortisol, testosterone and estrogen levels in groups of 100 men and 93 women who attended the Central Military Hospital in Prague for regular entrance psychological examinations for military personnel. RESULTS: In men, we detected positive correlations between cortisol and emotional lability, and negative correlations with impulsivity, while in women hypochondria and psychopathology were negatively correlated, and aggression measured with the Meili selective memory test had a positive relation to cortisol level. Testosterone correlated positively with emotional liability and negatively with impulsivity in men, and negatively with hypochondria and psychasteny, indirect aggression, irritability and paranoia in women. Estradiol correlated positively with psychopathology in men, and negatively with phobia. It was positively correlated with negativism in women. No clear correlation was observed between the concentration of steroid hormones and psychomotor performance or intelligence. CONCLUSIONS: Concentrations of steroid hormones correlate with results of several psychological tests, the sign and magnitude of these correlations, however, very often differ in military men and women.


Assuntos
Estrogênios/fisiologia , Hidrocortisona/fisiologia , Inteligência/fisiologia , Memória/fisiologia , Transtornos Mentais/fisiopatologia , Militares/psicologia , Desempenho Psicomotor/fisiologia , Testosterona/fisiologia , Adulto , Estrogênios/sangue , Feminino , Humanos , Hidrocortisona/sangue , Testes de Inteligência/estatística & dados numéricos , Masculino , Transtornos Mentais/sangue , Militares/estatística & dados numéricos , Escalas de Graduação Psiquiátrica/estatística & dados numéricos , Testosterona/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA