Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Hypertens ; 40(3): 453-461, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34654792

RESUMO

AIMS: The objective of this study was to examine the validity of 1 h automated office blood pressure measurement for the diagnosis of hypertension. METHODS: We included patients requiring a hypertension diagnostic test. Participants underwent ambulatory blood pressure monitoring, 1 h automated office blood pressure measurement, office blood pressure measurement and home blood pressure monitoring. The prevalence of hypertension and subtypes were calculated. Mean values of ambulatory blood pressure monitoring were compared with 1 h automated office blood pressure measurement using the correlation coefficient and Bland-Altman graphs. The Kappa concordance index, sensitivity, specificity and diagnostic accuracy were calculated, and the area under the receiver operating characteristic curve was used to establish the diagnostic threshold of the 1-h measurement. RESULTS: Of 562 participants, 438 (87.6%) completed the four diagnostic methods. The 1-h method had a sensitivity of 76.6 [95% confidence interval (95% CI): 71.1-81.5], a specificity of 64.8% (95% CI: 57-72.1) and the best diagnostic accuracy (72.1%, 95% CI: 67.7-76.3) compared with the office and home measurements. Moderate-high correlations were observed between DBP (r = 0.73) and SBP (r = 0.58) readings. The 1-h method classified more patients as normotensive (24.4%) and fewer patients with white-coat hypertension (13.3%). A diagnostic threshold of at least 133/83 mmHg for the 1-h method could improve diagnostic accuracy by 2.3%. CONCLUSION: One-hour automated blood pressure measurement is a valid, reliable method for the diagnosis of hypertension in undiagnosed patients. The diagnostic accuracy permits detection of white-coat and masked hypertension. To diagnose hypertension, the 1-h method or conventional home blood pressure monitoring should be used rather than office measurements. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT03147573.


Assuntos
Monitorização Ambulatorial da Pressão Arterial , Hipertensão , Pressão Sanguínea , Determinação da Pressão Arterial/métodos , Monitorização Ambulatorial da Pressão Arterial/métodos , Humanos , Reprodutibilidade dos Testes
2.
Autoimmun Rev ; 20(9): 102887, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34237422

RESUMO

OBJECTIVE: Cardiovascular (CV) morbidity is a well-established problem in systemic lupus erythematosus (SLE). Antimalarial (AM) therapy has been seen as a potential atheroprotective agent. The aim was to assess the impact of AM therapy on traditional and novel atherosclerosis (AT) biomarkers in patients with SLE. METHODS: A search of MEDLINE, EMbase, and Cochrane library for studies evaluating the impact of AM on AT biomarkers in SLE was conducted. Data extraction included serum, functional and structural traditional and novel biomarkers. A narrative synthesis of the findings and a meta-analysis with random effects was conducted estimating mean differences (MD), OR, HR and 95% CIs. RESULTS: The search strategy produced 148 articles, of which 64 were extracted for analysis. The MD in VLDL-cholesterol (-10.29, 95% CI -15.35, 5.24), triglycerides (-15.68, 95% CI -27.51, -3.86), and diastolic BP (-3.42, 95% CI -5.62, -1.23) differed significantly in patients on AM therapy compared with those without AM therapy. Patients on AM had a lower prevalence and incidence of diabetes mellitus than patients not on AM (HR: 0.39, 95% CI 0.17, 0.88). HCQ use was associated with lower blood pressure (BP) variability. Structural markers like carotid intima-media thickness (IMT), carotid plaque (CP) and coronary artery calcification (CAC) were not influenced by AM. For functional markers like endothelial and arterial stiffness the benefit was unclear. The GRADE approach showed a very low-to-low quality of evidence (QoE) per outcome. CONCLUSIONS: There is some evidence on the associations between AM therapy and some AT markers. However, the data on which this conclusion was based was of low to very low evidence.


Assuntos
Antimaláricos , Aterosclerose , Lúpus Eritematoso Sistêmico , Antimaláricos/uso terapêutico , Aterosclerose/diagnóstico , Aterosclerose/epidemiologia , Biomarcadores , Espessura Intima-Media Carotídea , Humanos , Lúpus Eritematoso Sistêmico/complicações , Lúpus Eritematoso Sistêmico/diagnóstico , Lúpus Eritematoso Sistêmico/tratamento farmacológico , Fatores de Risco
3.
Autoimmun Rev ; 18(10): 102371, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31415907

RESUMO

Systemic lupus erythematosus (SLE) is associated with a high burden of cardiovascular disease (CVD), which is in part imputed to classical vascular risk factors such as hypertension. Hypertension is frequent among patients with SLE and studies show it is more prevalent in SLE patients than in people without SLE. Despite the high frequency of hypertension in SLE patients, the pathophysiological mechanisms underlying the development of hypertension remain poorly understood. 24-h ambulatory blood pressure monitoring has emerged as a valuable tool in determining blood pressure (BP) in SLE patients in whom hypertension has been associated with damage accrual, stroke and cognitive dysfunction. Although prevalent, current guidelines neglect the specific management of hypertension in SLE patients in their recommendations. This review discusses the mechanisms that may lead to hypertension and the literature evaluating hypertension screening and management in SLE patients.


Assuntos
Hipertensão/complicações , Lúpus Eritematoso Sistêmico/etiologia , Lúpus Eritematoso Sistêmico/patologia , Humanos , Prognóstico , Fatores de Risco
4.
BMJ Open ; 9(5): e029268, 2019 05 27.
Artigo em Inglês | MEDLINE | ID: mdl-31133597

RESUMO

INTRODUCTION: 24-hour ambulatory blood pressure monitoring (ABPM) is the gold standard diagnostic method for hypertension, but has some shortcomings in clinical practice while clinical settings often lack sufficient devices to accommodate all patients with suspected hypertension. Home blood pressure monitoring (HBPM) and office blood pressure monitoring (OBPM) also have shortcomings, such as the white coat effect or a lack of accuracy. This study aims to study the validity of a new method of diagnosing hypertension consisting of monitoring blood pressure (BP) for 1 hour and comparing it with OBPM and HBPM and examining the sensitivity and specificity of this method compared with 24-hour ABPM. The patient experience will be examined in each method. METHODS AND ANALYSIS: A minimum sample of 214 patients requiring a diagnostic test for hypertension from three urban primary healthcare centres will be included. Participants will undergo 24-hour ABPM, 1-hour BP measurement (1-BPM), OBPM for three consecutive weeks and HBPM. Patients will follow a random sequence to first receive 24-hour ABPM or 1-hour ABPM. Daytime 24-hour ABPM records will be compared with the other monitoring methods using the correlation coefficient and Bland Altman plots. The kappa concordance index and the sensitivity and specificity of the methods will be calculated. The patient's experience will be studied, with selected indicators of efficiency and satisfaction calculated using parametric tests. ETHICS AND DISSEMINATION: The protocol has been authorised by the research ethics committee of the Hospital Clinic of Barcelona (Ref. HCB/2014/0615): protocol details and amendments will be recorded and reported to ClinicalTrials.com. The results will be disseminated in peer-reviewed literature, and to policy makers and healthcare partners. TRIAL REGISTRATION: NCT03147573; Pre-results.


Assuntos
Monitorização Ambulatorial da Pressão Arterial/métodos , Hipertensão/diagnóstico , Projetos de Pesquisa , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Rev Esp Cardiol (Engl Ed) ; 67(9): 717-23, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25172067

RESUMO

INTRODUCTION AND OBJECTIVES: Blood pressure measurement methods and conditions are determinants of hypertension diagnosis. A recent British guideline recommends systematic 24-h ambulatory blood pressure monitoring. However, these devices are not available at all health centers and they can only be used by 1 patient per day. The aim of this study was to test a new blood pressure recording method to see if it gave the same diagnostic results as 24-h blood pressure monitoring. METHODS: One-hour blood pressure monitoring under routine clinical practice conditions was compared with standard method of day time recording by analyzing the coefficient of correlation and Bland-Altman plots. The Kappa index was used to calculate degree of agreement. Method sensitivity and specificity were also analyzed. RESULTS: Of the 102 participants, 89 (87.3%) obtained the same diagnosis regardless of method, with high between-method agreement (κ= 0.81; 95% confidence interval, 0.71-0.91). We observed robust correlations between diastolic (r=0.85) and systolic blood pressure (r=0.76) readings. Sensitivity and specificity for the new method for diagnosing white coat hypertension were 85.2% (95% confidence interval 67.5%-94.1%) and 92% (95% confidence interval, 83.6%-96.3%), respectively. CONCLUSIONS: One-hour blood pressure monitoring is a valid and reliable method for diagnosing hypertension and for classifying hypertension subpopulations, especially in white coat hypertension and refractory hypertension. This also leads to a more productive use of monitoring instruments.


Assuntos
Determinação da Pressão Arterial/métodos , Hipertensão/diagnóstico , Monitorização Ambulatorial da Pressão Arterial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA