Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
J Bone Joint Surg Am ; 106(4): 288-303, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-37995211

RESUMO

BACKGROUND: Social determinants of health (SDOH) are important factors in the delivery of orthopaedic care. The purpose of this study was to investigate the relationship between outcomes following total knee arthroplasty (TKA) and both the Social Vulnerability Index (SVI) and the Area Deprivation Index (ADI). METHODS: The Michigan Arthroplasty Registry Collaborative Quality Initiative (MARCQI) database was utilized to identify TKA cases for inclusion. Demographic characteristics and medical history were documented. The SVI, its subthemes, and the ADI were analyzed. Outcome data included length of stay, discharge disposition, postoperative change in the Knee Injury and Osteoarthritis Outcome Score, Joint Replacement (KOOS, JR), 90-day incidences of emergency department (ED) visits, readmission, death, deep venous thrombosis (DVT) and/or pulmonary embolism (PE), periprosthetic fracture, implant failure, periprosthetic joint infection (PJI), and all-cause reoperation. Database cross-referencing was completed to document aseptic and septic revisions beyond 90 days postoperatively. Bivariate quartile-stratified and multivariable analyses were used to associate deprivation metrics with outcomes. RESULTS: A total of 19,321 TKA cases met inclusion criteria. Baseline patient characteristics varied among the SVI and/or ADI quartiles, with patients of non-White race and with a greater number of comorbidities noted in higher deprivation quartiles. Higher SVI and/or ADI quartiles were correlated with an increased rate of discharge to a skilled nursing facility (p < 0.05). A higher SVI and/or ADI quartile was associated with increased incidences of ED visits and readmissions postoperatively (p < 0.05). DVT and/or PE and long-term aseptic revision were the complications most strongly associated with higher deprivation metrics. Upon multivariable analysis, greater length of stay and greater incidences of ED visits, readmissions, DVT and/or PE, and aseptic revision remained significantly associated with greater deprivation based on multiple metrics. CONCLUSIONS: Greater deprivation based on multiple SVI subthemes, the composite SVI, and the ADI was significantly associated with increased length of stay, non-home discharge ED visits, and readmissions. The SVI and the ADI may be important considerations in the perioperative assessment of patients who undergo TKA. LEVEL OF EVIDENCE: Prognostic Level IV . See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Artroplastia do Joelho , Embolia Pulmonar , Humanos , Artroplastia do Joelho/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Determinantes Sociais da Saúde , Michigan , Comorbidade , Embolia Pulmonar/epidemiologia , Estudos Retrospectivos
2.
J Am Acad Orthop Surg ; 32(4): 169-177, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38100772

RESUMO

BACKGROUND: The purpose of this study was to investigate the effect of various social determinants of health on outcomes and dispositions after total knee arthroplasty (TKA). METHODS: A retrospective review was conducted on 14,462 consecutive TKA procedures between 2013 and 2021 at a multicenter hospital system. Data abstraction was done by inquiry to the Michigan Arthroplasty Registry Collaborative Quality Initiative. Data points requested included basic demographics, marital status, race, insurance status, socioeconomic status measured by the Area of Deprivation Index, perioperative course, and incidence of emergency department (ED) visits and readmissions within 3 months of surgery. Subsequent multivariate analyses were conducted. RESULTS: Unmarried patients required markedly greater lengths of hospital stay and had an increased rate of discharge to skilled nursing facilities and a higher likelihood of any purpose ED visit within 90 days of surgery compared with married patients, who had a significantly greater rate of same-day discharge ( P < 0.001). Race did not markedly correlate with outcomes. Medicare patients showed a greater rate of same-day discharge, nonhome discharge, and 90-day ED visits compared with privately insured patients ( P < 0.001). Medicaid patients were more likely than privately insured patients to have a 90-day ED visit ( P < 0.001). Socioeconomic status had a minimal clinical effect on all studied outcomes. CONCLUSION: Social factors are important considerations in understanding outcomes after TKA. Additional investigations are indicated in identifying at-risk patients and subsequent optimization of these patients.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Humanos , Idoso , Estados Unidos , Artroplastia do Joelho/efeitos adversos , Medicare , Alta do Paciente , Tempo de Internação , Estado Civil , Estudos Retrospectivos , Readmissão do Paciente , Fatores de Risco
3.
BMJ Case Rep ; 15(6)2022 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-35760505

RESUMO

A man in his late 30s developed non-ischaemic cardiomyopathy due to systemic cobalt toxicity associated with accelerated bearing surface wear from metal-on-metal hip resurfacing implanted in the previous 6 years. Following revision arthroplasty, the patient regained baseline cardiac function. Cobalt-induced cardiomyopathy is a grave condition that deserves early consideration due to potentially irreversible morbidity. We present this case to increase awareness, facilitate early detection and emphasise the need for research into the diagnosis and management of at-risk patients.


Assuntos
Artroplastia de Quadril , Cardiomiopatias , Prótese de Quadril , Próteses Articulares Metal-Metal , Artroplastia de Quadril/efeitos adversos , Cardiomiopatias/etiologia , Cobalto/efeitos adversos , Prótese de Quadril/efeitos adversos , Humanos , Masculino , Próteses Articulares Metal-Metal/efeitos adversos , Metais , Desenho de Prótese , Falha de Prótese
5.
J Am Acad Orthop Surg ; 29(2): e92-e97, 2021 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-32568995

RESUMO

BACKGROUND: The purpose of this study was to compare the incidence of pseudotumors in metal-on-metal (MoM) titanium modular neck hip arthroplasties to non-MoM modular neck hip arthroplasties. A secondary goal was to determine whether a correlation exists between elevated metal concentrations and pseudotumor incidence. METHODS: The data were collected and evaluated from 49 MoM joints and 26 non-MoM joints between the years 2012 and 2017. Hip ultrasonography was done after a minimum of 5 years postimplantation. Whole serum metal (titanium, cobalt, and chromium) concentrations were measured at the hip ultrasonography study. RESULTS: The average time elapsed between surgery and ultrasonography visit was 7.6 years. In the 49 patients with MoM joints, 22.4% (n = 11) had a pseudotumor. In the 26 patients with non-MoM joints, 9.1% of metal-on-polyethylene hips (n = 1) and 0% of ceramic-on-ceramic/polyethylene hips developed a pseudotumor. No significant statistical correlation was observed between serum metal concentrations and pseudotumor formation (P > 0.05). A significant correlation was observed of serum titanium concentration to pseudotumor size (P = 0.024). CONCLUSION: The incidence of pseudotumor formation in MoM total hip arthroplasties was more than five times the incidence associated with non-MoM bearings. The correlation between serum titanium concentration and pseudotumor size suggests that titanium levels may be a useful indicator for pseudotumor formation in patients with this particular titanium modular neck femoral implant. No notable correlation was observed between serum cobalt and chromium concentration and pseudotumor formation or size.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Humanos , Incidência , Próteses Articulares Metal-Metal/efeitos adversos , Desenho de Prótese
6.
J Arthroplasty ; 35(11): 3230-3236.e3, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32665157

RESUMO

BACKGROUND: The purpose of this study is to determine if there is a difference in echocardiographic results between patients with metal-on-metal (MoM) vs non-MoM total hip arthroplasty (THA) and to determine if a correlation exists between serum metal levels and echocardiographic outcomes. METHODS: Seventy-five patients with the same modular THA enrolled in this prospective cohort study, and 49 had MoM bearings. All patients had serum cobalt, chromium, and titanium levels drawn at 2 study visits with a transthoracic echocardiogram at the second visit. Serum metal concentrations and echocardiographic parameters were compared with 2-way t-tests. Multiple linear regression analyses identified any significant predictors of echocardiographic outcomes. RESULTS: Mean serum cobalt and chromium levels were significantly greater in the MoM group at both time-points (P < .001 and P < .05, respectively). Titanium levels were similar between groups (P > .05). MoM patients had significantly lower global longitudinal strain compared with the non-MoM group (18.4% vs 20.2%; P = .026). Serum cobalt concentration was found to be an independent predictor of tricuspid annular plane systolic excursion (P = .02). CONCLUSION: MoM THA bearings are associated with increased serum cobalt and chromium levels. Patients with MoM THAs had decreased global longitudinal strain, a measure of left ventricular function, but both groups remained within normal range. The clinical impact of the positive association between serum cobalt concentration and tricuspid annular plane systolic excursion, a marker of right ventricular function, deserves further study. These findings can reassure physicians and patients that metal-induced cardiomyopathy is not typical in the setting of MoM THA. LEVEL OF EVIDENCE: Level II, Prospective Cohort Study.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Artroplastia de Quadril/efeitos adversos , Cromo , Cobalto/efeitos adversos , Ecocardiografia , Prótese de Quadril/efeitos adversos , Humanos , Próteses Articulares Metal-Metal/efeitos adversos , Estudos Prospectivos , Desenho de Prótese
8.
J Am Acad Orthop Surg ; 28(10): e422-e426, 2020 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-31415300

RESUMO

INTRODUCTION: This study compares functional outcome scores and revision rates between metal-on-metal (MoM) and non-MoM total hip arthroplasty patients. METHODS: A cohort of 75 patients who underwent implantation of the same dual modular hip arthroplasty between the years of 2004 and 2010 was enrolled. Patients were subsequently evaluated in 2015 to 2017 for joint revision history and functionality, as measured by the Harris hip score (HHS). Patients requiring a revision arthroplasty were not included in the HHS analysis. RESULTS: A total of 49 patients had MoM implants (65.3%), and 26 patients had non-MoM implants (34.8%). At a mean follow-up of 7.6 years, 10.2% (5/49) of MoM prostheses required revision, whereas 3.8% (1/26) of non-MoM prostheses required revision (P = 0.334). The mean HHS in the MoM cohort was 89.8, compared with 88.1 in the non-MoM cohort (P = 0.69). CONCLUSION: HHSs were not notably different between cohorts. The MoM cohort had three times as many revisions as the non-MoM cohort, but given the numbers available, this difference did not reach significance. Given the clinical importance of these revision data, further study is warranted to determine survivorship of the MoM versus non-MoM total hip arthroplasty at long-term follow-up.


Assuntos
Artroplastia de Quadril/métodos , Prótese de Quadril , Metais , Recuperação de Função Fisiológica , Reoperação/estatística & dados numéricos , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Desenho de Prótese
9.
J Bone Joint Surg Am ; 101(1): 14-24, 2019 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-30601412

RESUMO

BACKGROUND: Periprosthetic joint infection (PJI) following total knee arthroplasty is a growing concern, as the demand for total knee arthroplasty (TKA) expands annually. Although 2-stage revision is considered the gold standard in management, there is substantial morbidity and mortality associated with this strategy. One-stage revision is associated with lower mortality rates and better quality of life, and there has been increased interest in utilizing the 1-stage strategy. However, surgeons are faced with a difficult decision regarding which strategy to use to treat these infections, considering uncertainty with respect to eradication of infection, quality of life, and societal costs with each strategy. The purpose of the current study was to use decision analysis to determine the optimal decision for the management of PJI following TKA. METHODS: An expected-value decision tree was constructed to estimate the quality-adjusted life-years (QALYs) and costs associated with 1-stage and 2-stage revision. Two decision trees were created: Decision Tree 1 was constructed for all pathogens, and Decision Tree 2 was constructed solely for difficult-to-treat infections, including methicillin-resistant infections. Values for parameters in the decision model, such as mortality rate, reinfection rate, and need for additional surgeries, were derived from the literature. Medical costs were derived from Medicare data. Sensitivity analysis determined which parameters in the decision model had the most influence on the optimal strategy. RESULTS: In both decision trees, the 1-stage strategy produced greater health utility while also being more cost-effective. In the Monte Carlo simulation for Decision Trees 1 and 2, 1-stage was the dominant strategy in about 85% and 69% of the trials, respectively. Sensitivity analysis showed that the reinfection and 1-year mortality rates were the most sensitive parameters influencing the optimal decision. CONCLUSIONS: Despite 2-stage revision being considered the current gold standard for infection eradication in patients with PJI following TKA, the optimal decision that produced the highest quality of life was 1-stage revision. These results should be considered in shared decision-making with patients who experience PJI following TKA. LEVEL OF EVIDENCE: Economic and Decision Analysis Level IV. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Artroplastia do Joelho/métodos , Tomada de Decisão Clínica/métodos , Técnicas de Apoio para a Decisão , Infecções por Bactérias Gram-Negativas/cirurgia , Infecções por Bactérias Gram-Positivas/cirurgia , Infecções Relacionadas à Prótese/cirurgia , Reoperação/métodos , Artroplastia do Joelho/economia , Artroplastia do Joelho/mortalidade , Árvores de Decisões , Infecções por Bactérias Gram-Negativas/economia , Infecções por Bactérias Gram-Negativas/mortalidade , Infecções por Bactérias Gram-Positivas/economia , Infecções por Bactérias Gram-Positivas/mortalidade , Custos de Cuidados de Saúde/estatística & dados numéricos , Humanos , Prótese do Joelho/efeitos adversos , Cadeias de Markov , Medicare , Método de Monte Carlo , Infecções Relacionadas à Prótese/economia , Infecções Relacionadas à Prótese/mortalidade , Anos de Vida Ajustados por Qualidade de Vida , Reoperação/economia , Reoperação/mortalidade , Estados Unidos
10.
Arthroplast Today ; 4(3): 370-375, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30186924

RESUMO

BACKGROUND: The etiology of wear particle generation and subsequent corrosion in modular total hip arthroplasty implants likely begins with mechanical fretting. The purpose of this study was to determine geometric features of the male and female taper surfaces that drive stability within the neck-stem junction. METHODS: Eighteen modular hip components received 3-dimensional surface scans to examine the neck-stem taper junction using an optical scanner. The normal distance between the surfaces of the neck taper as seated in the stem slot was measured and produced a color map of the contact proximity. Contour plots identified surface shape variation and contact. Angle measurements and neck seated depth were analyzed by regression. RESULTS: The typical features observed were (1) a vertical line of contact at one end of the transition from the flat surface to the radius surface; (2) a vertical line of contact in the radius surface just past the centerline; (3) a concavity along the flat surface between the neck and stem components; and (4) one of the neck flat surfaces was closer to its mating surface on the stem. The seated depth of the neck was dependent on the taper angles in the flat section of the neck (R2 = 0.5000, P = .0332). CONCLUSIONS: The shape of the neck and stem tapers deviate from ideal design dimensions, contributing to relative motions between the neck and stem. While these processes are not proven to directly cause implant failure, they may place the implants at higher risk for failure.

11.
Arthroplast Today ; 3(2): 131-136, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28695186

RESUMO

BACKGROUND: The purpose of this study was to determine the accuracy of used and new reamer systems for both hemispherical and minimally invasive (MIS) acetabular reamers. METHODS: New and used hemispherical and MIS acetabular reamers were tested on a computer numerical control machine to ream holes in special machinable wax blocks. Each reamer was tested 3 times in sizes 48 mm through 55 mm. RESULTS: The used reamers significantly underreamed by an average of 1.33 vs 0.28 mm compared to new reamers. Hemispherical reamers underreamed significantly more than MIS reamers, with a mean difference of 0.99 vs 0.63 mm, respectively. Used hemispherical reamers showed an average ream undersize of 1.61 vs 0.37 mm, compared to new hemispherical reamers. Used MIS reamers showed an average ream undersize of 1.06 vs 0.20 mm for the new MIS reamers. CONCLUSIONS: For a manufacturer-specified reamer size, both hemispherical and MIS reamers underream. Newer reamers cut truer to expected values than used ones. MIS reamers performed more accurately than hemispherical reamers. Used acetabular reamer systems may negatively affect the sizing of prepared acetabular beds; therefore, awareness of this potential inaccuracy should be considered when performing total hip arthroplasty.

12.
Arthroplast Today ; 3(2): 119-124, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28695184

RESUMO

BACKGROUND: The purpose of this study was to investigate the stability of dual-taper modular implants following impaction forces delivered at varying locations as measured by the distraction forces required to disassemble the components. METHODS: Distraction of the head-neck and neck-stem (NS) tapers of dual-taper modular implants with 0°, 8°, and 15° neck angles were measured utilizing a custom-made distraction fixture attached to a servohydraulic materials test machine. Distraction was measured after hand pressing the components as well as following a simulated firm hammer blow impaction. Impacts to the 0°, 8°, 15° necks were directed axially in line with the neck, 10° anterior, and 10° proximal to the axis of the neck, respectively. RESULTS: Impaction increased the range of NS component distraction forces when compared to hand pressed components (1125-1743 N vs 248-302 N, respectively). Off-axis impacts resulted in significantly reduced mean (±95% confidence interval) distraction forces (8° neck, 1125 ± 117 N; 15° neck, 1212 ± 73 N), which were up to 35% lower than the mean distraction force for axial impacts to the 0° neck (1743 ± 138 N). CONCLUSIONS: Direction of impaction influences stability of the modular interface. The greatest stability was achieved with impaction directed in line with the longitudinal axis of the taper junction. Off-axis impaction of the 8° and 15° neck led to significantly reduced stability at the NS. Improving stability of dual-taper modular hip prostheses with appropriately directed impaction may help to minimize micromotion, component settling, fretting corrosion, and subsequent failure.

13.
Skeletal Radiol ; 46(5): 641-649, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28204856

RESUMO

OBJECTIVE: The use of metal-on-metal and modular total hip arthroplasty is associated with potentially serious local and systemic complications. The primary aim of this study was to identify the prevalence of a pseudotumor in asymptomatic patients with a particular metal-on-metal hip prosthesis after a minimum follow-up of 5 years using ultrasound evaluation. A secondary purpose was to identify associations between the presence of pseudotumor and serum metal ion levels following implantation. METHODS: We prospectively evaluated data collected from 36 asymptomatic patients who underwent implantation of a Profemur Z metal-on-metal total hip arthroplasty from January 2004 to January 2010. Serum metal ion levels were collected in 2012 and 2015. Hip ultrasounds were performed in 2015. RESULTS: Pseudotumors were found in 7/36 patients (19.4%). The average pseudotumor size measured 38.2 cm3 (range 7.35 cm3-130.81 cm3). Elevated metal ion levels were found in all patients at all time points. No statistical correlation was found between the presence of pseudotumor and patient age, age of the implant, component design, and any of the serum metal ion levels or ratios. CONCLUSIONS: One in every five asymptomatic patients with metal-on-metal implants was found to have a periarticular pseudotumor. There was no dose-dependent relationship found between elevated serum metal ion levels and the development of a pseudotumor. Our findings suggest that in patients with known elevated metal ion levels, continued monitoring of ion levels may not be a reliable predictor of pseudotumor formation, and ultrasound surveillance can and should be routinely used to document the presence and progression of pseudotumor.


Assuntos
Artroplastia de Quadril/instrumentação , Granuloma de Células Plasmáticas/diagnóstico por imagem , Articulação do Quadril/diagnóstico por imagem , Próteses Articulares Metal-Metal/efeitos adversos , Metais/sangue , Ultrassonografia/métodos , Idoso , Feminino , Seguimentos , Granuloma de Células Plasmáticas/sangue , Articulação do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Prospectivos
14.
Orthopedics ; 40(1): 56-63, 2017 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-27783839

RESUMO

Total hip arthroplasty (THA) and total knee arthroplasty (TKA) are common and successful orthopedic procedures, and as their frequency continues to increase substantially, the focus on limiting perioperative complications heightens. Intraoperative normothermia is recommended to minimize additional complications, but limited evidence exists regarding the effect of hypothermia on orthopedic patients. The purpose of this retrospective study was to determine the incidence of perioperative hypothermia in the setting of TKA and THA, and to evaluate its impact on complications and outcomes. The clinical records of 2580 consecutive patients who underwent TKA or THA at a single institution between January 1, 2011, and December 31, 2013 were reviewed. After excluding patients with complex or revision procedures, a total of 2397 patients comprised the study population. Patient demographic data, surgery-specific data, postoperative complications, length of hospital stay, and 30-day readmission were recorded. Patients with a mean intraoperative temperature less than 36°C were identified as hypothermic. Statistical analysis evaluated associations with hypothermia and the effect on complications and outcomes. The incidence of mean intraoperative hypothermia was 37%, 43.9%, and 32.6% for arthroplasty, THA, and TKA, respectively. General anesthesia was significantly associated with hypothermia (P<.001). Women and THA patients were at higher risk for hypothermia. In the arthroplasty and THA cohorts, longer operating room time and re-warmer use were associated with hypothermia (P=.010). Overall, hypothermia was associated with increased estimated blood loss, but no increase in associated transfusion was demonstrated (P=.006). Hypothermia was not associated with postoperative complications. [Orthopedics. 2017; 40(1):56-63.].


Assuntos
Artroplastia de Quadril/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Hipotermia/epidemiologia , Idoso , Transfusão de Sangue , Feminino , Humanos , Hipotermia/etiologia , Incidência , Complicações Intraoperatórias/epidemiologia , Complicações Intraoperatórias/etiologia , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Fatores Sexuais
15.
J Arthroplasty ; 32(4): 1328-1334, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27884418

RESUMO

BACKGROUND: Heterotopic ossification (HO) is a known complication following total hip arthroplasty. Radiation is an effective prophylaxis, but an optimal protocol has yet to be determined. We performed a randomized, double-blinded clinical trial in high-risk patients to determine the efficacy of 400 vs 700 cGy doses of radiation. METHODS: One hundred forty-seven patients undergoing total hip arthroplasty and at high risk for HO at an urban medical center were randomized to receive either a single 400 or 700 cGy dose of radiation postoperatively. High risk was defined as a diagnosis of diffuse idiopathic skeletal hyperostosis, hypertrophic osteoarthritis, ankylosing spondylitis, or history of previous HO. Radiation was administered on the first or second postoperative day. A single blinded reviewer graded radiographs taken immediately postoperatively and at a minimum of 6 months postoperatively using the Brooker classification. Progression was defined as an increase in Brooker classification. Operative data including surgical approach, implant fixation, revision surgery, and postoperative range of motion data were also collected. RESULTS: A significantly greater portion of patients who received the 400 cGy dose demonstrated progression of HO than patients who received the 700 cGy dose. There were no wound complications. No preoperative factors were associated with a higher rate of progression. Patients who progressed had less flexion on physical examination than patients who did not progress, but this was not clinically significant. CONCLUSION: Seven hundred centigray was superior to 400 cGy in preventing HO formation following total hip arthroplasty in high-risk patients and may be the more effective treatment in this population. Further studies comparing 700 cGy to dosages between 400 and 700 cGy may help to clarify if a more optimal dose can be identified.


Assuntos
Artroplastia de Quadril/efeitos adversos , Ossificação Heterotópica/etiologia , Ossificação Heterotópica/prevenção & controle , Radioterapia , Adulto , Idoso , Artroplastia de Quadril/estatística & dados numéricos , Progressão da Doença , Método Duplo-Cego , Feminino , Articulação do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite/complicações , Exame Físico , Período Pós-Operatório , Radiografia , Dosagem Radioterapêutica , Amplitude de Movimento Articular , Reoperação/estatística & dados numéricos , Espondilite Anquilosante/complicações , Resultado do Tratamento
16.
Orthopedics ; 39(6): e1170-e1177, 2016 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-27536952

RESUMO

Hip fractures are common orthopedic injuries and are associated with significant morbidity/mortality. Intraoperative normothermia is recommended by national guidelines to minimize additional morbidity/mortality, but limited evidence exists regarding hypothermia's effect on orthopedic patients. The purpose of this study was to determine the incidence of intraoperative hypothermia in patients with operatively treated hip fractures and evaluate its effect on complications and outcomes. Retrospective chart review was performed on clinical records from 1541 consecutive patients who sustained a hip fracture and underwent operative fixation at the authors' institution between January 2005 and October 2013. A total of 1525 patients were included for analysis, excluding those with injuries requiring additional surgical intervention. Patient demographic data, surgery-specific data, postoperative complications, length of stay, and 30-day readmission were recorded. Patients with a mean intraoperative temperature less than 36°C were identified as hypothermic. Statistical analysis with univariate and multivariate logistic regression modeling evaluated associations with hypothermia and effect on complications/outcomes. The incidence of intraoperative hypothermia in operatively treated hip fractures was 17.0%. Hypothermia was associated with an increase in the rate of deep surgical-site infection (odds ratio, 3.30; 95% confidence interval, 1.19-9.14; P=.022). Lower body mass index and increasing age demonstrated increased association with hypothermia (P=.004 and P=.005, respectively). To the authors' knowledge, this is the first and largest study analyzing the effect of intraoperative hypothermia in orthopedic patients. In patients with hip fractures, the study's findings confirm evidence found in other surgical specialties that hypothermia may be associated with an increased risk of deep surgical-site infection and that lower body mass index and increasing age are risk factors for intraoperative hypothermia. [Orthopedics. 2016; 39(6):e1170-e1177.].


Assuntos
Fraturas do Quadril/cirurgia , Hipotermia/etiologia , Infecção da Ferida Cirúrgica/etiologia , Adulto , Idoso , Feminino , Humanos , Incidência , Complicações Intraoperatórias , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco
17.
Orthopedics ; 39(5): e844-9, 2016 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-27172370

RESUMO

Perioperative blood management remains a challenge during total hip arthroplasty (THA) and total knee arthroplasty (TKA). The purpose of this study was to systematically examine the relationship between body mass index (BMI) and perioperative blood transfusion during THA and TKA while attempting to resolve conflicting results in previously published studies. The authors retrospectively evaluated 2399 patients, 896 of whom underwent THA and 1503 of whom underwent TKA. Various outcome variables were assessed for their relationship to BMI, which was stratified using the World Health Organization classification scheme (normal, <25 kg/m(2); overweight, 25-30 kg/m(2); obese, >30 kg/m(2)). Among patients undergoing THA, transfusion rates were 34.8%, 27.6%, and 21.9% for normal, overweight, and obese patients, respectively (P=.002). Among patients undergoing TKA, transfusion rates were 17.3%, 11.4%, and 8.3% for normal, overweight, and obese patients, respectively (P=.002). Patients with an elevated BMI have decreased rates of blood transfusion following both THA and TKA. This same cohort also loses a significantly decreased percentage of estimated blood volume. No trends were identified for a relationship between BMI and deep venous thrombosis, pulmonary embolism, myocardial infarction, discharge location, length of stay, 30-day readmission rate, and preoperative hemoglobin level. Elevated BMI was significantly associated with increased estimated blood loss in patients undergoing THA and those undergoing TKA. There was a statistically significant trend toward increased deep surgical-site infection in patients undergoing THA (P=.043). Patients with increased BMI have lower rates of blood transfusion and lose a significantly smaller percentage of estimated blood volume following THA and TKA. [Orthopedics.2016; 39(5):e844-e849.].


Assuntos
Artroplastia de Quadril/estatística & dados numéricos , Artroplastia do Joelho/estatística & dados numéricos , Perda Sanguínea Cirúrgica/estatística & dados numéricos , Transfusão de Sangue/estatística & dados numéricos , Índice de Massa Corporal , Artroplastia de Quadril/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Humanos , Obesidade/epidemiologia , Sobrepeso/epidemiologia , Transfusão de Plaquetas , Embolia Pulmonar , Estudos Retrospectivos , Infecção da Ferida Cirúrgica , Trombose Venosa
18.
J Arthroplasty ; 31(9): 2053-7, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-26970905

RESUMO

BACKGROUND: The purpose of this study was to investigate the effect that off-axis impaction has on stability of dual-taper modular implants as measured by forces delivered to and transmitted through the head-neck and neck-stem tapers, respectively. METHODS: One hundred forty-four impact tests were performed using 6 different directions: one on-axis and five 10° off-axes. Four different simulations were performed measuring the head-neck only and 3 different neck angulations: 0°, 8°, and 15°. A drop tower impactor delivered both on- and off-axis impaction from a constant height. Load cells positioned in the drop mass and at the head-neck (HN) or neck-stem (NS) junction measured the impact and joint forces, respectively. RESULTS: Impact force of the hammer on the head ranged from 3800-4500 N. Greatest impact force delivered to the head was typically with axial impact. However, greatest force transmission to the neck-stem junction was not necessarily with axial impacts. There was limited variability in the force measured at the NS junction for all impaction directions seen in the 8° neck, whereas the 15° neck had greater forces transmitted to the NS junction with off-axes impactions directed in the proximal and posterior-proximal directions. CONCLUSION: The location of the impact significantly influences the force transmitted to the head-neck and neck-stem junctions in dual-taper modular hip implants. Although axial impacts proved superior to off-axis impacts for the straight 0° neck, greater force transmission with off-axis impacts for the angled necks suggests that off-axis impacts may potentially compromise the stability of dual-taper components.


Assuntos
Artroplastia de Quadril/métodos , Prótese de Quadril , Simulação por Computador , Humanos , Modelos Teóricos , Desenho de Prótese , Estresse Mecânico
20.
J Arthroplasty ; 31(5): 1022-6, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-26703193

RESUMO

BACKGROUND: Tranexamic acid (TXA) reduces perioperative blood loss in total hip arthroplasty (THA). METHODS: In our randomized control trial, 139 patients were enrolled and received 2 g of either topical or intravenous (IV) TXA. Preoperative and postoperative protocols were standardized. RESULTS: Calculated blood and Hgb loss were lower in the IV group (1195.0 ± 485.9 mL, 1442.7 ± 562.7 mL; P = .006), (160.3 [g] ± 63.8, 188.4 [g] ± 68.5; P = .014). There was a trend toward significance in transfusion reduction (11% [IV] vs 18% [topical]; P = .3). Both groups effectively reduced the transfusion rate. There was significant financial incentive for the use of TXA in THA with a savings of $314 per patient. CONCLUSIONS: IV and topical TXA are effective tools to reduce blood loss and transfusion costs in THA, and we recommend the IV form for ease of use.


Assuntos
Antifibrinolíticos/administração & dosagem , Artroplastia de Quadril , Perda Sanguínea Cirúrgica/prevenção & controle , Hemorragia Pós-Operatória/prevenção & controle , Ácido Tranexâmico/administração & dosagem , Administração Intravenosa , Administração Tópica , Idoso , Antifibrinolíticos/uso terapêutico , Transfusão de Sangue , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Hemorragia Pós-Operatória/etiologia , Estudos Prospectivos , Ácido Tranexâmico/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA