Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 137
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38777625

RESUMO

BACKGROUND AND AIMS: Aortic stenosis (AS) is a progressive disease predominantly affecting elderly patients that carries significant morbidity and mortality without aortic valve replacement, the only proven treatment. Our objective was to determine the cost-effectiveness of AS screening using transthoracic echocardiography (TTE) in a geriatric population from the perspective of the publicly funded healthcare system in Canada. METHODS: Markov models estimating the cost-effectiveness ratio (ICER) for AS screening with a one-time TTE were developed. The model included diagnosed and undiagnosed AS health states, hospitalizations, TAVR and post-TAVR health states. Primary analysis included screening at 70 and 80 years of age with intervention at symptom onset, with scenario analysis included for early intervention at the time of severe asymptomatic AS diagnosis. Monte Carlo simulation of 5000 replications was completed with a lifetime horizon and 1.5% discount for costs and outcomes. RESULTS: Screening for AS at the age of 70 years was associated with an ICER of $156,722 and screening at 80 years of age was associated with an ICER of $28,005, suggesting that screening at 80 years of age is cost-effective when willingness-to-pay per QALY is $50,000. Scenario analysis with early intervention was not cost-effective with an ICER of $142,157 at 70 years, and $124,651 at 80 years. CONCLUSION: Screening for AS at 80 years of age with a one-time TTE, in a Canadian population, improves quality of life and is cost-effective in a publicly funded healthcare system providing TAVR is reserved for symptomatic patients.

2.
Eur J Heart Fail ; 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38606485

RESUMO

AIMS: Patients with heart failure and mildly reduced or preserved ejection fraction have limited therapeutic options. The ALT-FLOW Early Feasibility Study evaluated safety, haemodynamics and outcomes for the APTURE transcatheter shunt system, a novel left atrium to coronary sinus shunt in these patients. METHODS AND RESULTS: Safety and shunt implantation success was evaluated for all 116 enrolled patients. An analysis population of implanted patients with a left ventricular ejection fraction (LVEF) >40% (n = 95) was chosen to assess efficacy via paired comparison between baseline and follow-up haemodynamic (3 and 6 months), and echocardiographic, clinical and functional outcomes (6 months and 1 year). Health status and quality of life outcomes were assessed using the Kansas City Cardiomyopathy Questionnaire overall summary score (KCCQ-OSS). The primary safety endpoint, major adverse cardiac, cerebral, and renal events, and reintervention through 30 days, occurred in 3/116 patients (2.6%). All implanted shunts were patent at 1 year. In patients with LVEF >40%, the mean (95% confidence interval) reduction in exercise pulmonary capillary wedge pressure (PCWP) at 20 W was -5.7 (-8.6, -2.9) mmHg at 6 months (p < 0.001). At baseline, 8% had New York Heart Association class I-II status and improved to 68% at 1 year (p < 0.001). KCCQ-OSS at baseline was 39 (35, 43) and improved at 6 months and 1 year by 25 (20-30) and 27 (22-32) points, respectively (both p < 0.0001). No adverse changes in haemodynamic and echocardiographic indices of right heart function were observed at 1 year. Overall, the reduction in PCWP at 20 W and improvement in KCCQ-OSS in multiple subgroups were consistent with those observed for the entire population. CONCLUSIONS: In patients with heart failure and LVEF >40%, the APTURE shunt demonstrated an acceptable safety profile with significant sustained improvements in haemodynamic and patient-centred outcomes, underscoring the need for further evaluation of the APTURE shunt in a randomized trial.

3.
Heart Rhythm ; 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38365125

RESUMO

BACKGROUND: The hemodynamic effects of transcatheter left atrial appendage occlusion (LAAO) remain unclear. OBJECTIVE: We sought to assess the effect of LAAO on invasive hemodynamics and their correlation with clinical outcomes. METHODS: We recorded mean left atrial pressure (mLAP) before and after device deployment. We assessed the prevalence and predictors of mLAP increase after deployment, the association between significant mLAP increase after deployment and 45-day peridevice leak (PDL), and the association between mLAP increase and heart failure (HF) hospitalization. A significant mLAP increase was defined as one equal to or greater than the mean percentage increase in mLAP after deployment (≥28%). RESULTS: We included 302 patients (36.4% female; mean age, 75.8 ± 9.5 years). After deployment, mLAP increased in 48% of patients, 38% of whom experienced significant mLAP increase. Independent predictors of mLAP increase were baseline mLAP ≤14 mm Hg, nonparoxysmal atrial fibrillation, and age per 5 years (odds ratios: 3.66 [95% CI, 2.21-6.05], 1.81 [95% CI, 1.08-3.02], and 0.85 [95% CI, 0.73-0.99], respectively). Significant mLAP increase was an independent predictor of 45-day PDL (odds ratio, 2.55; 95% CI, 1.04-6.26). There was no association between mLAP increase and HF hospitalization. CONCLUSION: After deployment, mLAP acutely rises in 48% of patients, although this is not associated with increased HF hospitalizations. PDL is more likely to develop at 45 days in patients with significant increase in mLAP after deployment, although most leaks were small (<5 mm). These findings suggest that mLAP increase after deployment is not associated with major safety concerns. Additional studies are warranted to explore the long-term hemodynamic effects of LAAO.

4.
JACC Cardiovasc Interv ; 16(22): 2722-2732, 2023 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-38030358

RESUMO

BACKGROUND: Scarce data exist on the evolution of device-related thrombus (DRT) after left atrial appendage closure (LAAC). OBJECTIVES: This study sought to assess the incidence, predictors, and clinical impact of persistent and recurrent DRT in LAAC recipients. METHODS: Data were obtained from an international multicenter registry including 237 patients diagnosed with DRT after LAAC. Of these, 214 patients with a subsequent imaging examination after the initial diagnosis of DRT were included. Unfavorable evolution of DRT was defined as either persisting or recurrent DRT. RESULTS: DRT resolved in 153 (71.5%) cases and persisted in 61 (28.5%) cases. Larger DRT size (OR per 1-mm increase: 1.08; 95% CI: 1.02-1.15; P = 0.009) and female (OR: 2.44; 95% CI: 1.12-5.26; P = 0.02) were independently associated with persistent DRT. After DRT resolution, 82 (53.6%) of 153 patients had repeated device imaging, with 14 (17.1%) cases diagnosed with recurrent DRT. Overall, 75 (35.0%) patients had unfavorable evolution of DRT, and the sole predictor was average thrombus size at initial diagnosis (OR per 1-mm increase: 1.09; 95% CI: 1.03-1.16; P = 0.003), with an optimal cutoff size of 7 mm (OR: 2.51; 95% CI: 1.39-4.52; P = 0.002). Unfavorable evolution of DRT was associated with a higher rate of thromboembolic events compared with resolved DRT (26.7% vs 15.1%; HR: 2.13; 95% CI: 1.15-3.94; P = 0.02). CONCLUSIONS: About one-third of DRT events had an unfavorable evolution (either persisting or recurring), with a larger initial thrombus size (particularly >7 mm) portending an increased risk. Unfavorable evolution of DRT was associated with a 2-fold higher risk of thromboembolic events compared with resolved DRT.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Tromboembolia , Trombose , Humanos , Feminino , Incidência , Apêndice Atrial/diagnóstico por imagem , Resultado do Tratamento , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Fibrilação Atrial/complicações , Tromboembolia/diagnóstico por imagem , Tromboembolia/epidemiologia , Tromboembolia/etiologia , Trombose/diagnóstico por imagem , Trombose/epidemiologia , Trombose/etiologia , Acidente Vascular Cerebral/etiologia
5.
NPJ Digit Med ; 6(1): 201, 2023 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-37898711

RESUMO

Focused cardiac ultrasound (FoCUS) is becoming standard practice in a wide spectrum of clinical settings. There is limited data evaluating the real-world use of FoCUS with artificial intelligence (AI). Our objective was to determine the accuracy of FoCUS AI-assisted left ventricular ejection fraction (LVEF) assessment and compare its accuracy between novice and experienced users. In this prospective, multicentre study, participants requiring a transthoracic echocardiogram (TTE) were recruited to have a FoCUS done by a novice or experienced user. The AI-assisted device calculated LVEF at the bedside, which was subsequently compared to TTE. 449 participants were enrolled with 424 studies included in the final analysis. The overall intraclass coefficient was 0.904, and 0.921 in the novice (n = 208) and 0.845 in the experienced (n = 216) cohorts. There was a significant bias of 0.73% towards TTE (p = 0.005) with a level of agreement of 11.2%. Categorical grading of LVEF severity had excellent agreement to TTE (weighted kappa = 0.83). The area under the curve (AUC) was 0.98 for identifying an abnormal LVEF (<50%) with a sensitivity of 92.8%, specificity of 92.3%, negative predictive value (NPV) of 0.97 and a positive predictive value (PPV) of 0.83. In identifying severe dysfunction (<30%) the AUC was 0.99 with a sensitivity of 78.1%, specificity of 98.0%, NPV of 0.98 and PPV of 0.76. Here we report that FoCUS AI-assisted LVEF assessments provide highly reproducible LVEF estimations in comparison to formal TTE. This finding was consistent among senior and novice echocardiographers suggesting applicability in a variety of clinical settings.

6.
Front Cardiovasc Med ; 10: 1130304, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37745122

RESUMO

Introduction: Patients undergoing coronary stent implantation incur a 2% annual rate of adverse events, largely driven by in-stent restenosis (ISR) due to neointimal (NI) tissue proliferation, a process in which smooth muscle cell (SMC) biology may play a central role. Dipyridamole (DP) is an approved therapeutic agent with data supporting improved vascular patency rates. Pre-clinical data supports that DP may enact its vasculoprotective effects via adenosine receptor-A2B (ADOR-A2B). We sought to evaluate the efficacy of DP to mitigate ISR in a pre-clinical rabbit stent model. Methods & Results: 24 New Zealand White Rabbits were divided into two cohorts-non-atherosclerosis and atherosclerosis (n = 12/cohort, 6 male and 6 female). Following stent implantation, rabbits were randomized 1:1 to control or oral dipyridamole therapy for 6 weeks followed by optical coherence tomography (OCT) and histology assessment of NI burden and stent strut healing. Compared to control, DP demonstrated a 16.6% relative reduction in NI volume (14.7 ± 0.8% vs. 12.5 ± 0.4%, p = 0.03) and a 36.2% relative increase in optimally healed stent struts (37.8 ± 2.8% vs. 54.6 ± 2.5%, p < 0.0001). Atherosclerosis demonstrated attenuated effect with no difference in NI burden (15.2 ± 1.0% vs. 16.9 ± 0.8%, p = 0.22) and only a 14.2% relative increase in strut healing (68.3 ± 4.1% vs. 78.7 ± 2.5%, p = 0.02). DP treated rabbits had a 44.6% (p = 0.045) relative reduction in NI SMC content. In vitro assessment of DP and coronary artery SMCs yielded dose-dependent reduction in SMC migration and proliferation. Selective small molecule antagonism of ADOR-A2B abrogated the effects of DP on SMC proliferation. DP modulated SMC phenotypic switching with ADOR-A2B siRNA knockdown supporting its role in the observed effects. Conclusion: Dipyridamole reduces NI proliferation and improves stent healing in a preclinical model of stent implantation with conventional antiplatelets. Atherosclerosis attenuates the observed effect. Clinical trials of DP as an adjunctive agent may be warranted to evaluate for clinical efficacy in stent outcomes.

7.
Crit Care Explor ; 5(9): e0962, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37649849

RESUMO

OBJECTIVES: Inotropic support is commonly used in patients with cardiogenic shock (CS). High-quality data guiding the use of dobutamine or milrinone among this patient population is limited. We compared the efficacy and safety of these two inotropes among patients with low cardiac output states (LCOS) or CS. DATA SOURCES: MEDLINE, Embase, and Cochrane Central Register of Controlled Trials were searched up to February 1, 2023, using key terms and index headings related to LCOS or CS and inotropes. DATA EXTRACTION: Two independent reviewers included studies that compared dobutamine to milrinone on all-cause in-hospital mortality, length of ICU stay, length of hospital stay, and significant arrhythmias in hospitalized patients. DATA SYNTHESIS: A total of eleven studies with 21,084 patients were included in the meta-analysis. Only two randomized controlled trials were identified. The primary outcome, all-cause mortality, favored milrinone in observational studies only (odds ratio [OR] 1.19 (95% CI, 1.02-1.39; p = 0.02). In-hospital length of stay (LOS) was reduced with dobutamine in observational studies only (mean difference -1.85 d; 95% CI -3.62 to -0.09; p = 0.04). There was no difference in the prevalence of significant arrhythmias or in ICU LOS. CONCLUSIONS: Only limited data exists supporting the use of one inotropic agent over another exists. Dobutamine may be associated with a shorter hospital LOS; however, there is also a potential for increased all-cause mortality. Larger randomized studies sufficiently powered to detect a difference in these outcomes are required to confirm these findings.

9.
J Clin Med ; 12(15)2023 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-37568289

RESUMO

BACKGROUND: Transcatheter pulmonary valve implantation (TPVI) is an effective non-surgical treatment method for patients with right ventricle outflow tract dysfunction. The Medtronic Melody and the Edwards Sapien are the two valves approved for use in TPVI. Since TPVI patients are typically younger, even a modest annual incidence of infective endocarditis (IE) is significant. Several previous studies have shown a growing risk of IE after TPVI. There is uncertainty regarding the overall incidence of IE and differences in the risk of IE between the valves. METHODS: A systematic search was conducted in the MEDLINE, EMBASE, PubMed, and Cochrane databases from inception to 1 January 2023 using the search terms 'pulmonary valve implantation', 'TPVI', or 'PPVI'. The primary outcome was the pooled incidence of IE following TPVI in Melody and Sapien valves and the difference in incidence between Sapien and Melody valves. Fixed effect and random effect models were used depending on the valve. Meta-regression with random effects was conducted to test the difference in the incidence of IE between the two valves. RESULTS: A total of 22 studies (including 10 Melody valve studies, 8 Sapien valve studies, and 4 studies that included both valves (572 patients that used the Sapien valve and 1395 patients that used the Melody valve)) were used for the final analysis. Zero IE incidence following TPVI was reported by eight studies (66.7%) that utilized Sapien valves compared to two studies (14.3%) that utilized Melody valves. The pooled incidence of IE following TPVI with Sapien valves was 2.1% (95% CI: 0.9% to 5.13%) compared to 8.5% (95% CI: 4.8% to 15.2%) following TPVI with Melody valves. Results of meta-regression indicated that the Sapien valve had a 79.6% (95% CI: 24.2% to 94.4%, p = 0.019; R2 = 34.4) lower risk of IE incidence compared to the Melody valve. CONCLUSIONS: The risk of IE following TPVI differs significantly. A prudent valve choice in favor of Sapien valves to lower the risk of post-TPVI endocarditis may be beneficial.

11.
J Am Coll Cardiol ; 81(24): 2361-2373, 2023 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-37316116

RESUMO

Pulmonary vein stenosis (PVS) can arise from several etiologies, including congenital, acquired, and iatrogenic sources. PVS presents insidiously, leading to significant delays in diagnosis. A high index of suspicion and dedicated noninvasive evaluation are key to diagnosis. Once diagnosed, both noninvasive and invasive evaluation may afford further insights into the relative contribution of PVS to symptoms. Treatment of underlying reversible pathologies coupled with transcatheter balloon angioplasty and stenting for persistent severe stenoses are established approaches. Ongoing refinements in diagnostic modalities, interventional approaches, postintervention monitoring, and medical therapies hold promise to further improve patient outcomes.


Assuntos
Angioplastia com Balão , Estenose de Veia Pulmonar , Humanos , Estenose de Veia Pulmonar/diagnóstico , Estenose de Veia Pulmonar/etiologia , Estenose de Veia Pulmonar/terapia , Constrição Patológica/diagnóstico , Constrição Patológica/etiologia , Constrição Patológica/terapia , Stents
13.
BMJ Open ; 13(5): e070720, 2023 05 12.
Artigo em Inglês | MEDLINE | ID: mdl-37173116

RESUMO

INTRODUCTION: Transradial access (TRA) has rapidly emerged as the preferred vascular access site for coronary angiography and percutaneous coronary intervention. Radial artery occlusion (RAO) remains as an important complication of TRA as it precludes future ipsilateral transradial procedures. While intraprocedural anticoagulation has been studied extensively, the definitive role of postprocedural anticoagulation has not yet been established. METHODS AND ANALYSIS: The Rivaroxaban Post-Transradial Access for the Prevention of Radial Artery Occlusion trial is a multicentre, prospective, randomised, open-label, blinded-endpoint design study investigating the efficacy and safety of rivaroxaban to reduce the incidence of RAO. Eligible patients will undergo randomisation to receive either rivaroxaban 15 mg once daily for 7 days or to no additional postprocedural anticoagulation. Doppler ultrasound to assess radial artery patency will be performed at 30 days. ETHICS AND DISSEMINATION: The study protocol has been approved by the Ottawa Health Science Network Research Ethics Board (approval number 20180319-01H). The study results will be disseminated via conference presentations and peer-reviewed publications. TRIAL REGISTRATION NUMBER: NCT03630055.


Assuntos
Arteriopatias Oclusivas , Intervenção Coronária Percutânea , Humanos , Rivaroxabana/uso terapêutico , Artéria Radial , Estudos Prospectivos , Angiografia Coronária/métodos , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/prevenção & controle , Arteriopatias Oclusivas/epidemiologia , Intervenção Coronária Percutânea/efeitos adversos , Anticoagulantes/uso terapêutico , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento
14.
J Cardiovasc Transl Res ; 16(5): 1194-1204, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37227686

RESUMO

Percutaneous coronary intervention (PCI) is a management strategy for symptomatic obstructive coronary artery disease (CAD). Despite advancements, in-stent restenosis (ISR) still imparts a 1-2% annual rate of repeat revascularization-a focus of ongoing translational research. Optical coherence tomography (OCT) provides high resolution virtual histology of stents. Our study evaluates the use of OCT for virtual histological assessment of stent healing in a rabbit aorta model, enabling complete assessment of intraluminal healing throughout the stent. ISR varies based on intra-stent location, stent length, and stent type in a rabbit model-important considerations for translational experimental design. Atherosclerosis leads to more prominent ISR proliferation independent of stent-related factors. The rabbit stent model mirrors clinical observations, while OCT-based virtual histology demonstrates utility for pre-clinical stent assessment. Pre-clinical models should incorporate clinical and stent factors as feasible to maximize translation to clinical practice.


Assuntos
Doença da Artéria Coronariana , Reestenose Coronária , Intervenção Coronária Percutânea , Animais , Coelhos , Intervenção Coronária Percutânea/efeitos adversos , Tomografia de Coerência Óptica/métodos , Angiografia Coronária , Reestenose Coronária/patologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Vasos Coronários/patologia , Stents , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Neointima/patologia , Resultado do Tratamento
16.
Am Heart J ; 262: 83-89, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37094667

RESUMO

BACKGROUND: Cardiogenic shock (CS) is a state of end-organ hypoperfusion related to cardiac dysfunction. Current guidelines recommend consideration of inotrope therapy in patients with CS, however no robust data support their use. The purpose of the CAPITAL DOREMI2 trial is to examine the efficacy and safety of inotrope therapy against placebo in the initial resuscitation of patients with CS. METHODS AND DESIGN: This is a multi-center, double-blind, randomized, placebo-controlled trial comparing single-agent inotrope therapy to placebo in patients with CS. A total of 346 participants with Society for Cardiovascular Angiography and Interventions class C or D CS will be randomized in a 1:1 fashion to inotrope or placebo therapy, which will be administered over a 12-hour period. After this period, participants will continue open-label therapies at the discretion of the treating team. The primary outcome is a composite of all-cause in-hospital death, and, as measured during the 12-hour intervention period, any of: sustained hypotension or high dose vasopressor requirements, lactate greater than 3.5 mmol/L at 6 hours or thereafter, need for mechanical circulatory support, arrhythmia leading to emergent electrical cardioversion, and resuscitated cardiac arrest. All participants will be followed for the duration of their hospitalization, and secondary outcomes will be assessed at the time of discharge. IMPLICATION: This trial will be the first to establish the safety and efficacy of inotrope therapy against placebo in a population of patients with CS and has the potential to alter the standard care provided to this group of patients.


Assuntos
Parada Cardíaca , Choque Cardiogênico , Humanos , Choque Cardiogênico/terapia , Choque Cardiogênico/tratamento farmacológico , Mortalidade Hospitalar , Vasoconstritores/uso terapêutico , Método Duplo-Cego , Parada Cardíaca/complicações , Resultado do Tratamento
18.
JACC Cardiovasc Interv ; 16(11): 1369-1380, 2023 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-36989271

RESUMO

BACKGROUND: Heart failure (HF) is associated with both mortality and a significant decline in health status. Interatrial shunting is increasingly being investigated as a novel therapeutic option. OBJECTIVES: The ALT FLOW Early Feasibility Study was designed to evaluate the safety of the Edwards left atrial to coronary sinus APTURE Transcatheter Shunt System in patients with symptomatic HF. METHODS: A total of 18 centers enrolled patients with symptomatic HF with a pulmonary capillary wedge pressure >15 mm Hg at rest or 25 mm Hg during exercise. RESULTS: Between May 2018 and September 2022, 87 patients underwent attempted APTURE shunt implantation. Mean age was 71 years, and 53% were male. At baseline, mean left ventricular ejection fraction was 59% with 90% of the patients being in NYHA functional class III. Device success was achieved in 78 patients (90%), with no device occlusions or associated adverse events identified after implantation. The primary safety outcome occurred in only 2 patients (2.3%) at 30 days. At 6 months, health status improved: 67% of participants achieved NYHA functional class I to II status, with a 23-point improvement (P < 0.0001; 95% CI: 17-29 points) in the Kansas City Cardiomyopathy Questionnaire overall summary score. Also at 6 months, 20-W exercise pulmonary capillary wedge pressure was 7 mm Hg lower (P < 0.0001; 95% CI: -11 to -4 mm Hg) without change in right atrial pressure or other right heart function indices. CONCLUSIONS: In this single-arm experience, the APTURE Transcatheter Shunt System in patients with symptomatic HF was observed to be safe and resulted in reduction in pulmonary capillary wedge pressure and clinically meaningful improvements in HF symptoms and quality of life indices.


Assuntos
Fibrilação Atrial , Seio Coronário , Insuficiência Cardíaca , Humanos , Masculino , Idoso , Feminino , Volume Sistólico , Função Ventricular Esquerda , Seio Coronário/diagnóstico por imagem , Qualidade de Vida , Cateterismo Cardíaco , Resultado do Tratamento , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia
19.
Catheter Cardiovasc Interv ; 101(3): 605-609, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36718052

RESUMO

BACKGROUND: Elevated transmitral gradient post transcatheter mitral valve edge-to-edge repair (TEER) has been associated with worse outcomes. Whether an elevated baseline transmitral diastolic mean gradient (MG) ≥5 mmHg is associated with hemodynamic outcomes after TEER is unknown. METHODS: A total of 164 consecutive patients undergoing TEER at Mayo Clinic between June 2014 and May 2018 were analyzed in this retrospective study. Baseline demographics, as well as clinical, echocardiographic, and procedural data were obtained. Data on direct left atrial pressure (LAP) before and after TEER were recorded. Logistic regression models were constructed to evaluate the association between preprocedure transmitral diastolic mean gradient (pre-MG) and (1) improvement in LAP following TEER, (2) postprocedure transmitral diastolic mean gradient (post-MG). A decrease in LAP post TEER was considered an improvement in hemodynamic response. Pre-MG was categorized as: ≥5 and <5 mmHg. RESULTS: Median age of the cohort was 81.5 years (Q1: 76.3, Q3: 87) and 34% were female. At baseline, median transmitral diastolic MG was 4 mmHg (Q1: 3, Q3: 5) and median LAP was 19 mmHg (Q1:16, Q3: 23.5). In a multivariable model, adjusted for age and sex, patients with pre-MG ≥ 5 mmHg were less likely to see an improvement in LAP post TEER (adjusted odds ratio [aOR]: 0.22, 95% confidence interval [CI]: 0.09, 0.55; p = 0.001) and more likely to have elevated post-MG (aOR; 7.08, 95% CI: 2.93, 17.13; p < 0.001). CONCLUSION: Higher pre-MG (≥5 mmHg) was associated with a lower reduction in LAP and higher residual transmitral gradient following TEER suggesting other potential contributors to increased LAP besides mitral regurgitation as a cause of elevated baseline MG.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Feminino , Idoso de 80 Anos ou mais , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Pressão Atrial , Estudos Retrospectivos , Resultado do Tratamento , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia
20.
Can J Cardiol ; 39(4): 394-402, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36150583

RESUMO

BACKGROUND: Inotropic support is widely used in the management of cardiogenic shock (CS). Existing data on the incidence and significance of arrhythmic events in patients with CS on inotropic support is at high risk of bias. METHODS: The Dobutamine Compared to Milrinone (DOREMI) trial randomized patients to receive dobutamine or milrinone in a double-blind fashion. Patients with and without arrhythmic events (defined as arrhythmias requiring intervention or sustained ventricular arrhythmias) were compared to identify factors associated with their occurrence, and to examine their association with in-hospital mortality and secondary outcomes. RESULTS: Ninety-two patients (47.9%) had arrhythmic events, occurring equally with dobutamine and milrinone (P = 0.563). The need for vasopressor support at initiation of the inotrope and a history of atrial fibrillation were positively associated with arrhythmic events, whereas predominant right ventricular dysfunction, previous myocardial infarction, and increasing left ventricular ejection fraction were negatively associated with them. Supraventricular arrhythmic events were not associated with mortality (relative risk [RR], 0.97; 95% confidence interval [CI], 0.68-1.40; P = 0.879) but were positively associated with resuscitated cardiac arrests and hospital length of stay. Ventricular arrhythmic events were positively associated with mortality (RR, 1.66; 95% CI, 1.13-2.43; P = 0.026) and resuscitated cardiac arrests. Arrhythmic events were most often treated with amiodarone (97%) and electrical cardioversion (27%), which were not associated with mortality. CONCLUSIONS: Clinically relevant arrhythmic events occur in approximately one-half of patients with CS treated with dobutamine or milrinone and are associated with adverse clinical outcomes. Five factors may help to identify patients most at risk of arrhythmic events.


Assuntos
Dobutamina , Choque Cardiogênico , Humanos , Choque Cardiogênico/etiologia , Dobutamina/uso terapêutico , Milrinona/uso terapêutico , Volume Sistólico , Função Ventricular Esquerda , Arritmias Cardíacas/induzido quimicamente
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA