Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 22(24)2022 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-36559977

RESUMO

Scanning microwave microscopy (SMM) is a novel metrological tool that advances the quantitative, nanometric, high-frequency, electrical characterization of a broad range of materials of technological importance. In this work, we report an inverted near-field scanning microwave microscopy (iSMM) investigation of a graphene oxide-based epoxy nanocomposite material at a nanoscopic level. The high-resolution spatial mapping of local conductance provides a quantitative analysis of the sample's electrical properties. In particular, the electrical conductivity in the order of ∼10-1 S/m as well as the mapping of the dielectric constant with a value of ∼4.7 ± 0.2 are reported and validated by the full-wave electromagnetic modeling of the tip-sample interaction.

2.
Acta Biomed ; 92(6): e2021221, 2022 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-35075078

RESUMO

BACKGROUND AND AIM: Three-dimensional (3D) printing is prevailing in surgical planning of complex cases. The aim of this study is to describe the use of 3D printed models during the surgical planning for the treatment of four pediatric hip deformity cases. Moreover, pediatric pelvic deformities analyzed by 3D printed models have been object of a concise review. METHODS: All treated patients were females, with an average age of 5 years old. Patients' dysplastic pelvises were 3D-printed in real scale using processed files from Computed Tomography (CT) or Magnetic Resonance Imaging (MRI). Data about 3D printing, surgery time, blood loss and fluoroscopy have been recorded. RESULTS: The Zanoli-Pemberton or Ganz-Paley osteotomies were performed on the four 3D printed models, then the real surgery was performed in the operating room. Time and costs to produce 3D printed models were respectively on average 17:26 h and 34.66 €. The surgical duration took about 87.5 min while the blood loss average was 1.9 ml/dl. Fluoroscopy time was 21 sec. MRI model resulted inaccurate and more difficult to produce. 10 papers have been selected for the concise literature review. CONCLUSIONS: 3D printed models have proved themselves useful in the reduction of surgery time, blood loss and ionizing radiation, as well as they have improved surgical outcomes. 3D printed model is a valid tool to deepen the complex anatomy and orientate surgical choices by allowing surgeons to carefully plan the surgery.


Assuntos
Procedimentos de Cirurgia Plástica , Impressão Tridimensional , Criança , Pré-Escolar , Feminino , Humanos , Imageamento por Ressonância Magnética , Osteotomia , Tomografia Computadorizada por Raios X
3.
Radiol Technol ; 93(3): 246-254, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-35017268

RESUMO

PURPOSE: To evaluate the accuracy of 3-D printed models of the femoral head based on preoperative computed tomography (CT) images. Other goals were to compare the cartilage thickness of bony specimen to the printed models and calculate the standard deviation between 3-D printed models based on CT images and laser scan models. METHODS: This retrospective study analyzed 10 patients who underwent preoperative CT imaging and hip replacement. Preoperative femoral head 3-D printed models were produced from CT images. Bony specimens were collected from surgical operations and scanned using CT and 3-D laser scanning, and cartilage thickness subsequently was measured by histological analysis. Comparisons of printed models based on CT images and printed models based on 3-D laser scanning were performed by overlapping their external surfaces using dedicated software and the standard deviation was calculated. RESULTS: The average standard deviation between the bony specimen 3-D models and preoperative 3-D printed CT femoral head models was 0.651 mm. The cartilage was approximately 1.487 mm thick. DISCUSSION: The comparison between preoperative CT image-based 3-D models and the postoperative bony specimen-based models permitted evaluation of the accuracy of preoperative CT image-based 3-D printed models. Cartilage thickness was estimated indirectly by comparing models obtained by CT and laser scanning, and it was related to the calculated standard deviation to overcome the cartilage detection limit of CT. This study shows how each step can generate accuracy errors on the final 3-D printed model. A repeatable and sustainable workflow for creating accurate and reproducible 3-D printed models could overcome this issue. Moreover, orthopedic surgeons should be aware of 3-D printed model precision in clinical practice. CONCLUSIONS: This study provides encouraging results on the accuracy of 3-D printed models for surgical planning.


Assuntos
Impressão Tridimensional , Tomografia Computadorizada por Raios X , Fêmur , Humanos , Imageamento Tridimensional , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
4.
Materials (Basel) ; 12(9)2019 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-31075986

RESUMO

Friction stir welds are considered reliable joints for their lack of voids, cracks and distortions. When compared to the base material, friction stir welding (FSW) joints typically exhibit finer grain structured (especially at the nugget zone, NZ). Similarly, refined grain structure can also be obtained by severe plastic deformation (SPD) techniques, such as equal channel angular pressing (ECAP). In fact, the fine grain structures produced within the NZ of FSW or friction stir processed (FSP) materials are usually coarser than the ones achieved by ECAP. The former is characterized by lower dislocation density, higher high-angle boundary fraction and different mechanical strength, compared to what can be obtained by ECAP. In this study, a dedicated cold-rolling (CR) set-up, specifically designed to simulate an ECAP-equivalent shear deformation, was used to further refine the grain structure of FSW AA5754 sheets. The effect of ECAP-equivalent deformation induced by CR in a 2 mm-thick AA5754-H111 FSW joint was investigated. FSW was carried out at two different rotational (ω) and translational (v) welding speeds, 600 rpm, 200 mm/min and 1800 rpm, 75 mm/min, respectively. FSW sheets were then CR to obtain an equivalent shear strain of ε ~ 1.08, that is equivalent to 1-ECAP pass carried out with an internal die channels intersecting at an angle φ = 90° with a curvature extending over an angle Ψ = 20°. By CR, the sheet thickness reduced only by ~20%. The role of annealing on the FSW and CR plastically deformed AA5754 was also investigated. This was applied either prior or after FSW, and it resulted that whenever it follows the FSW, the mean volume fraction of dispersoids and Mg-rich particles is higher than the case of annealing preceding the FSW process. On the contrary, it was found that the annealing treatment had a minimal role on the dispersoids and particles mean size. The here reported post-FSW ECAP-simulated deformation, obtained by a customized CR process, showed sheet integrity and a significant concurrent grain size refinement.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA