Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
1.
ESC Heart Fail ; 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38769653

RESUMO

AIMS: Technological advances and the current shortage of donor organs have contributed to an increase in the number of left ventricular assist device (LVAD) implantations in patients with end-stage heart failure. Demographic change and medical progress might raise the number of these patients, resulting in a further increase in the number of LVAD implantations. The aim of this study was to evaluate the long-term costs of LVAD therapy and identify diagnoses resulting in expensive stays. METHODS AND RESULTS: In this retrospective analysis of prospectively collected data, all patients after implantation of a second- or third-generation LVAD by 31 March 2022 were included. In addition to demographic and survival data, revenues and case mix points were determined for each patient. Of the 163 patients included, 75.5% were male. The mean age at LVAD implantation was 52 ± 14 years. The mean survival was 1458 ± 127 days. During follow-up, the total inpatient treatment time per patient was 70 ± 87 days. The average duration of outpatient treatment was 55.1%, based on the total duration of support. The average revenue per patient for the implant stay was $193 192.35 ± $111 801.29, for inpatient readmissions $52 068.96 ± $116 630.00, and for outpatient care $53 195.94 ± $62 363.53. CONCLUSIONS: LVAD implantation in patients with end-stage heart failure leads to improved survival but a significant increase in treatment costs. Further multi-centre studies are necessary in order to be able to assess the effects of long-term LVAD treatment on the healthcare system.

2.
J Clin Med ; 13(7)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38610851

RESUMO

Background: The global rise of obesity and its association with cardiovascular risk factors (CVRF) have highlighted its connection to chronic heart failure (CHF). Paradoxically, obese CHF patients often experience better outcomes, a phenomenon known as the 'obesity paradox'. This study evaluated the 'obesity paradox' within a large cohort in Germany and explored how varying degrees of obesity affect HF outcome. Methods: Anonymized health claims data from the largest German insurer (AOK) for the years 2014-2015 were utilized to analyze 88,247 patients hospitalized for myocardial infarction. This analysis encompassed baseline characteristics, comorbidities, interventions, complications, and long-term outcomes, including overall survival, freedom from CHF, and CHF-related rehospitalization. Patients were categorized based on body mass index. Results: Obese patients encompassed 21.3% of our cohort (median age 68.69 years); they exhibited a higher prevalence of CVRF (p < 0.001) and comorbidities than non-obese patients (median age 70.69 years). Short-term outcomes revealed lower complication rates and mortality (p < 0.001) in obese compared to non-obese patients. Kaplan-Meier estimations for long-term analysis illustrated increased incidences of CHF and rehospitalization rates among the obese, yet with lower overall mortality. Multivariable Cox regression analysis indicated that obese individuals faced a higher risk of developing CHF and being rehospitalized due to CHF but demonstrated better overall survival for those classified as having low-level obesity (p < 0.001). Conclusions: This study underscores favorable short-term outcomes among obese individuals. The 'obesity paradox' was confirmed, with more frequent CHF cases and rehospitalizations in the long term, alongside better overall survival for certain degrees of obesity.

3.
ESC Heart Fail ; 11(1): 271-281, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37967837

RESUMO

AIMS: Current guidelines suggest calcium channel blockers (CCBs) as the second or third option for blood pressure management in patients with left ventricular assist device (LVAD). However, the clinical outcomes of patients with LVAD who receive CCBs remain unclear. Our study aims to analyse the association of CCBs with clinical outcomes in patients after LVAD implantation. METHODS AND RESULTS: This is a retrospective analysis based on the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) from 2006 to 2017, and adult patients who were alive with LVAD and CCB treatment information at 6 months after implantation were included. Among 10 717 patients, 1369 received CCBs 6 months after implantation, and there was an increasing trend of CCB use after LVAD. Patients receiving CCB therapy at 6 months had a similar 5 year survival rate to those not receiving CCB [49.6%, 95% confidence interval (CI): 47.5-51.7% vs. 51.1%, 95% CI: 45.3-56.7%]. In both Cox and competing risk regressions after adjusting for confounding factors, CCB treatment at 6 months after implantation was not associated with long-term mortality [hazard ratio (HR): 1.03, 95% CI: 0.91-1.17, P = 0.624 and subdistribution HR (SHR): 1.07, 95% CI: 0.95-1.22, P = 0.260]. Consistently, in time-varying models, CCB treatment was not linked to long-term mortality (HR: 0.97, 95% CI: 0.87-1.09, P = 0.682 and SHR: 1.05, 95% CI: 0.94-1.18, P = 0.359). This null association remained in subgroup analysis according to device strategy and propensity-matching analyses. Neurological dysfunction, stroke, bleeding, rehospitalization, and renal dysfunction were more likely to occur among those with CCB when compared with those without CCB treatment. CONCLUSIONS: In patients with LVAD, CCB therapy fails to show benefits in long-term survival and is associated with increased incidences of neurological dysfunction, bleeding, renal dysfunction, and rehospitalization.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Nefropatias , Adulto , Humanos , Coração Auxiliar/efeitos adversos , Bloqueadores dos Canais de Cálcio/uso terapêutico , Estudos Retrospectivos
4.
Front Cardiovasc Med ; 10: 1223635, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38028489

RESUMO

Aims: Cardiomyopathy in Fabry disease (FD) is a major determinant of morbidity and mortality. This study investigates the effects of FD-specific treatment using enzyme replacement therapy (ERT) and chaperone therapy on left atrial (LA) function using two-dimensional speckle tracking echocardiography (2DSTE). Methods and results: In this prospective observational single-center study, 20 FD patients [10 (50%) females] treated with migalastat, 48 FD patients [24 (50%) females] treated with ERT (agalsidase-alfa and agalsidase-beta), and 30 untreated FD patients (all females) as controls were analyzed. The mean follow-up time ranged from 26 to 81 months. 2DSTE was performed for left ventricle strain, right ventricle strain, and LA strain (LAS). FD-specific treated patients presented with increased left ventricular mass index (LVMi) and higher frequency of left ventricular hypertrophy at baseline, whereas untreated control patients showed normal baseline values. FD-specific treated (including migalastat and ERT) patients showed stabilization of LAS over time (p > 0.05). LVMi was also stable in treated FD patients during observation (p > 0.05). Conclusion: In patients with FD, treated with either ERT or chaperone therapy, LAS values measured by echocardiographic speckle tracking were stable over time, pointing toward disease stabilization.

5.
J Heart Lung Transplant ; 42(4): 512-521, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36333208

RESUMO

BACKGROUND: Elevated pulmonary vascular resistance (PVR) is broadly accepted as an imminent risk factor for mortality after heart transplantation (HTx). However, no current HTx recipient risk score includes PVR or other hemodynamic parameters. This study examined the utility of various hemodynamic parameters for risk stratification in a contemporary HTx population. METHODS: Patients from seven German HTx centers undergoing HTx between 2011 and 2015 were included retrospectively. Established risk factors and complete hemodynamic datasets before HTx were analyzed. Outcome measures were overall all-cause mortality, 12-month mortality, and right heart failure (RHF) after HTx. RESULTS: The final analysis included 333 patients (28% female) with a median age of 54 (IQR 46-60) years. The median mean pulmonary artery pressure was 30 (IQR 23-38) mm Hg, transpulmonary gradient 8 (IQR 5-10) mm Hg, and PVR 2.1 (IQR 1.5-2.9) Wood units. Overall mortality was 35.7%, 12-month mortality was 23.7%, and the incidence of early RHF was 22.8%, which was significantly associated with overall mortality (log-rank HR 4.11, 95% CI 2.47-6.84; log-rank p < .0001). Pulmonary arterial elastance (Ea) was associated with overall mortality (HR 1.74, 95% CI 1.25-2.30; p < .001) independent of other non-hemodynamic risk factors. Ea values below a calculated cutoff represented a significantly reduced mortality risk (HR 0.38, 95% CI 0.19-0.76; p < .0001). PVR with the established cutoff of 3.0 WU was not significant. Ea was also significantly associated with 12-month mortality and RHF. CONCLUSIONS: Ea showed a strong impact on post-transplant mortality and RHF and should become part of the routine hemodynamic evaluation in HTx candidates.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Doenças Vasculares , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/cirurgia , Transplante de Coração/mortalidade , Hemodinâmica , Circulação Pulmonar/fisiologia , Estudos Retrospectivos , Doenças Vasculares/complicações , Doenças Vasculares/mortalidade , Doenças Vasculares/fisiopatologia , Resistência Vascular/fisiologia
6.
Thorac Cardiovasc Surg ; 70(6): 475-481, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35785810

RESUMO

BACKGROUND: Tricuspid regurgitation (TR) is common and related to poor prognosis in patients after left ventricular assist device (LVAD) implantation. The concomitant tricuspid valve surgery (TVS) at the time of LVAD implantation on short and long-term outcomes are controversial in current evidence. METHODS: This is a single-center, observational, retrospective study. We enrolled patients with moderate-to-severe TR who received LVAD implantations from 2009 to 2020. Postoperative right ventricular failure (RVF), right ventricular assist device (RVAD) use, hospital mortality, new-onset renal replacement therapy (RRT), and acute kidney injury (AKI) were evaluated retrospectively. RESULTS: Sixty-eight patients were included, 36 with and 32 without concomitant TVS. Baseline characteristics did not differ between the two groups. Patients receiving TVS had significantly increased incidences of postoperative RVF (52.8 vs. 25.0%, p = 0.019), RVAD implantation (41.7 vs. 18.8%, p = 0.041), and new-onset RRT (22.2 vs. 0%, p = 0.004). No difference in the incidence of AKI and hospital mortality was detected. Besides, these associations remained consistent in patients who underwent LVAD implantation via median sternotomy. During a median follow-up of 2.76 years, Kaplan-Meier analysis and competing-risk analysis showed that TVS was not associated with better overall survival in patients after LVAD implantation compared with the no-TVS group. CONCLUSION: Our study suggests that concomitant TVS failed to show benefits in patients receiving LVAD implantation. Even worse, concomitant TVS is associated with significantly increased incidences of RVF, RVAD use, and new-onset of RRT. Considering the small sample size and short follow-up, these findings warrant further study.


Assuntos
Injúria Renal Aguda , Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Coração Auxiliar , Insuficiência da Valva Tricúspide , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/etiologia , Injúria Renal Aguda/terapia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia
7.
Int J Artif Organs ; 45(5): 497-505, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35388731

RESUMO

OBJECTIVES: Left ventricular assist device (LVAD) implantation has become a reliable therapeutic strategy in patients with advanced heart failure. C-reactive protein (CRP) is a well-established biomarker of inflammation. This study aims to determine the prognostic effect of CRP level on clinical outcomes of patients who undergo LVAD implantation. METHODS: This is a single-center, observational, retrospective study. One hundred fifty-three patients who received continuous-flow LVAD implantation were included and were divided into two groups of high (>3.9 mg/dL) versus low CRP (⩽3.9 mg/dL). RESULTS: Patients with high pre-implant CRP levels were prone to severe preoperative clinical conditions and complicated intraoperative procedures. Compared with patients in the low CRP group, elevated pre-implant CRP was associated with increased hospital mortality (31.4% vs 8.4%, p < 0.001), postoperative right ventricular failure (47.1% vs 30.1%, p = 0.031), right ventricular assist device use (34.3% vs 16.9%, p = 0.013), AKI (70% vs 51.8%, p = 0.022) and significantly prolonged duration of postoperative mechanical ventilation and intensive care unit length of stay. Univariate Cox regression showed that high pre-implant CRP was significantly associated with increased risk of long-term mortality (Hazard ratio (HR) 2.632 95%; CI: 1.657-4.183, p < 0.001), and multivariable Cox regression also revealed the higher risk of long-term mortality in patients with elevated pre-implant CRP (HR, 2.848 95%CI: 1.659-4.888, p < 0.001). These results remained stable when treating pre-implant CRP as a continuous variable. Besides, the prognostic effect of post-implant CRP was also observed. CONCLUSIONS: CRP is a reliable risk-stratification biomarker in patients receiving continuous-flow -LVAD and can be used as a predictor for short- and long-term outcomes.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Proteína C-Reativa , Coração Auxiliar/efeitos adversos , Mortalidade Hospitalar , Humanos , Estudos Retrospectivos , Resultado do Tratamento
8.
Eur J Cardiothorac Surg ; 62(1)2022 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-35024851

RESUMO

OBJECTIVES: Gastrointestinal bleeding in patients with continuous-flow left ventricular assist devices (CF-LVAD) impairs quality of life and increases hospitalization rate. The Utah Bleeding Risk Score (UBRS) has been created to predict gastrointestinal bleeding (GIB) in patients on left ventricular assist device. We here aimed to externally validate UBRS on our cohort of CF-LVAD patients. METHODS: Utah Bleeding Risk Score was calculated, GIB events summarized on follow-up and patients stratified into 3 risk groups. Predictive ability of UBRS was examined at 3 years and during whole support time and person time incidence rates correlated to UBRS. In a sub-analysis, single effects of UBRS variables on freedom from GIB were assessed. RESULTS: A total of 111 CF-LVAD patients were included. The median UBRS was 2 (3-1). Receiver operating characteristic curve analysis showed an area under the curve of 0.519 (P = 0.758, 95% confidence interval = 0.422-0.615) at 3 years and an area under the curve of 0.515 (P = 0.797, 95% confidence interval = 0.418-0.611) during whole support time. No significant difference was observed in UBRS between bleeders and non-bleeders (P = 0.80). No significant difference in freedom from GIB was observed (P3 years = 0.7; Psupport-time = 0.816) and no independent significance regarding the freedom from bleeding at 3 years for any variable was observed. Coronary artery disease was associated with higher risk of GIB beyond the 3rd year (P = 0.048). CONCLUSIONS: UBRS was not able to predict GIB and therefore not applicable in our cohort of patients. Coronary artery disease could lead to a higher risk for GIB during support time. An additional validation in a larger cohort is advisable.


Assuntos
Doença da Artéria Coronariana , Insuficiência Cardíaca , Coração Auxiliar , Doença da Artéria Coronariana/complicações , Hemorragia Gastrointestinal/epidemiologia , Hemorragia Gastrointestinal/etiologia , Coração Auxiliar/efeitos adversos , Humanos , Qualidade de Vida , Estudos Retrospectivos , Fatores de Risco , Utah/epidemiologia
9.
Adv Clin Exp Med ; 31(5): 475-487, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35092651

RESUMO

BACKGROUND: Currently, data on sacubitril/valsartan therapy from the real-world settings are scarce and the predictors of a good clinical responsiveness to this drug are unknown. OBJECTIVES: To assess efficacy and safety profile of sacubitril/valsartan and to identify predictors for a better clinical outcome. MATERIAL AND METHODS: Clinical, laboratory and echocardiographic data of 95 chronic heart failure (CHF) patients with reduced ejection fraction (HFrEF) were retrospectively analyzed. A good efficacy of sacubitril/valsartan was defined as the fulfilment of at least 2 of the following criteria: improvement of left ventricular ejection fraction (LVEF) or functional status, and reduction of N-terminal pro-brain natriuretic peptide (NT-proBNP) levels or hospitalization rates. RESULTS: Under sacubitril/valsartan, major improvements were observed in LVEF, the New York Heart Association (NYHA) class, NT-proBNP levels, and hospitalization rates. Patients with a good efficacy of sacubitril/valsartan were characterized by initially worse LVEF (median (interquartile range (IQR)): 29.0% (23.0-33.0%) compared to 32.0% (28.5-38.0%) with more frequent nonischemic etiology (65.4% compared to 41.9%) and hospitalizations for CHF/month (0.016 (0.004-0.057) compared to 0.000 (0.000-0.012)), lower cholesterol (42.3% compared to 65.1%), higher C-reactive protein (CRP) levels at baseline (0.5 mg/L (0.5-1.0 mg/L) compared to 0.5 mg/L (0.5-0.5 mg/L)), and a shorter timespan between CHF diagnosis and the start of sacubitril/valsartan treatment (66.0 (11.0-127.0) compared to 111 (73.0-211.0) months) (p < 0.05 each). In a multivariate Cox analysis, only the last 2 parameters were shown to be independent predictors of good clinical responsiveness to sacubitril/valsartan (hazard ratio (HR) = 1.263, 95% confidence interval (95% CI) = [1.048; 1.521]; HR = 0.992, 95% CI = [0.987; 0.997], p < 0.05, respectively). CONCLUSIONS: Sacubitril/valsartan improved LVEF, NYHA class, NT-proBNP levels, and hospitalization rates, mostly without relevant side effects. The independent predictors of a good clinical efficacy were higher CRP levels at baseline and a shorter delay between CHF diagnosis and the initialization of sacubitril/valsartan therapy.


Assuntos
Insuficiência Cardíaca , Aminobutiratos/efeitos adversos , Antagonistas de Receptores de Angiotensina/efeitos adversos , Compostos de Bifenilo/efeitos adversos , Combinação de Medicamentos , Insuficiência Cardíaca/tratamento farmacológico , Humanos , Pacientes Ambulatoriais , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento , Valsartana/efeitos adversos , Função Ventricular Esquerda
10.
Front Cardiovasc Med ; 8: 763827, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34901224

RESUMO

Aims: Thromboembolic events, including stroke, are typical complications of COVID-19. Whether arrhythmias, frequently described in severe COVID-19, are disease-specific and thus promote strokes is unclear. We investigated the occurrence of arrhythmias and stroke during rhythm monitoring in critically ill patients with COVID-19, compared with severe pneumonia of other origins. Methods and Results: This retrospective study included 120 critically ill patients requiring mechanical ventilation in three European tertiary hospitals, including n =60 COVID-19, matched according to risk factors for the occurrence of arrhythmias in n = 60 patients from a retrospective consecutive cohort of severe pneumonia of other origins. Arrhythmias, mainly atrial fibrillation (AF), were frequent in COVID-19. However, when compared with non-COVID-19, no difference was observed with respect to ventricular tachycardias (VT) and relevant bradyarrhythmias (VT 10.0 vs. 8.4 %, p = ns and asystole 5.0 vs. 3.3%, p = ns) with consequent similar rates of cardiopulmonary resuscitation (6.7 vs. 10.0%, p = ns). AF was even more common in non-COVID-19 (AF 18.3 vs. 43.3%, p = 0.003; newly onset AF 10.0 vs. 30.0%, p = 0.006), which resulted in a higher need for electrical cardioversion (6.7 vs. 20.0%, p = 0.029). Despite these findings and comparable rates of therapeutic anticoagulation (TAC), the incidence of stroke was higher in COVID-19 (6.7.% vs. 0.0, p = 0.042). These events also happened in the absence of AF (50%) and with TAC (50%). Conclusions: Arrhythmias were common in severe COVID-19, consisting mainly of AF, yet less frequent than in matched pneumonia of other origins. A contrasting higher incidence of stroke independent of arrhythmias also observed with TAC, seems to be an arrhythmia-unrelated disease-specific feature of COVID-19.

11.
Thorac Cardiovasc Surg ; 69(1): 70-82, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-31170737

RESUMO

Cardiac rehabilitation physicians are faced to an increasing number of heart failure patients supported by left ventricular assist devices (LVAD). Many of these patients have complex medical issues and prolonged hospitalizations and therefore need special cardiac rehabilitation strategies including psychological, social, and educational support which are actually poorly implemented.Cardiac rehabilitation with clear guidance and more evidence should be considered as an essential component of the patient care plan especially regarding the increasing number of destination patients and their long-term follow-up.In this article the working group for postimplant treatment and rehabilitation of LVAD patients of the German Society for Prevention and Rehabilitation of Cardiovascular Diseases has summarized and updated the recommendations for the cardiac rehabilitation of LVAD patients considering the latest literature.


Assuntos
Reabilitação Cardíaca , Insuficiência Cardíaca/terapia , Coração Auxiliar , Pacientes Internados , Implantação de Prótese/instrumentação , Implantação de Prótese/reabilitação , Função Ventricular Esquerda , Reabilitação Cardíaca/efeitos adversos , Reabilitação Cardíaca/mortalidade , Consenso , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Implantação de Prótese/efeitos adversos , Implantação de Prótese/mortalidade , Recuperação de Função Fisiológica , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
12.
Artif Organs ; 44(3): 248-256, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31435951

RESUMO

For the success of the treatment with a left ventricular assist device (LVAD), both adequate self-management by the patient and an optimum level of support from the implanting hospital are crucial. A smartphone application has recently been developed within the framework of a European research project for the close monitoring of LVAD patients in order to improve upon their current aftercare situation. Using this new tool, different relevant parameters (eg, weight, international normalized ratio [INR], medication, LVAD parameters, symptoms, and photos of the driveline exit) can be sent daily or as required to a corresponding clinical application at the hospital for evaluation. The objective of this study was to monitor the functionality, acceptance, and usability of this smartphone application in LVAD patients. Prospective single-center study: in total, 13 patients (60 ± 7 years, 92% male, 1027 ± 653 days after LVAD implantation) were requested to test the application for approx. 4 weeks. At the end of the study, all entered data were evaluated and the patients were questioned regarding the acceptance and the usability. During the study period of mean 34 ± 8 days, a total of 453 data records (mean 35 ± 7 per patient) arrived at the hospital. In addition, a total of 19 photos of the driveline exit site were also sent via smartphone. The clinical application registered a total of 160 conspicuities. These comprised 126 INR deviations (target range 2.3-2.8) and 34 symptoms (mainly nosebleeds). The smartphone application functioned reliably, was well received by the patients and was graded highly for acceptance and usability. The results show that smartphone applications can definitely be used to improve aftercare in LVAD therapy in selected patients. Long-term studies are now needed to investigate the extent to which complications can be prevented, healthcare costs reduced, and quality of life increased.


Assuntos
Assistência ao Convalescente , Coração Auxiliar , Aplicativos Móveis , Telemedicina , Idoso , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Smartphone
13.
Int J Artif Organs ; 42(4): 201-206, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30520328

RESUMO

Following implantation of a left ventricular assist device, the build-up and long-term maintenance of adequate exercise capacity and functional performance become crucial. The aim of this study was to observe the development of exercise-related values at different times, as well as to detect possible influencing factors. We performed a prospective single-centre study: 10 patients (63 years, 100% male, body mass index = 27.5, 100% HeartWare) underwent the following diagnostic tests during cardiac rehabilitation and during two subsequent ambulatory visits: 6-min walking test, handgrip strength test, cardiopulmonary exercise test and Minnesota Living with Heart Failure questionnaire. Mean follow-up was 482 days after left ventricular assist device implantation. Significant improvements could be observed between the end of cardiac rehabilitation and ambulatory visit 1; 6-min walking distance increased from 367 to 449 m (p < 0.01), peak VO2 from 10.0 to 11.9 mL/kg/min (p < 0.05) and peak load from 62.4 to 83.0 W (p < 0.01). However, there were no further improvements between ambulatory visit 1 and ambulatory visit 2. In the long term, a significant mean weight gain of more than 10 kg could be observed (p < 0.01). A negative linear correlation between weight gain and absolute improvement in peak load (r = -0.77, p < 0.01) and peak VO2 (r = -0.75, p < 0.05) could be demonstrated. In conclusion, exercise-related values following left ventricular assist device implantation initially improve significantly. Later, however, no further improvements can be observed. In the long term, pronounced weight gain is conspicuous, concomitant with a significantly lower increase in exercise values of the patients. In the future, both dietary and structured physical activity follow-up interventions should be integrated in patient routines.


Assuntos
Tolerância ao Exercício , Insuficiência Cardíaca , Sobrepeso , Qualidade de Vida , Índice de Massa Corporal , Teste de Esforço/métodos , Força da Mão , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/psicologia , Insuficiência Cardíaca/terapia , Coração Auxiliar , Humanos , Assistência de Longa Duração/métodos , Assistência de Longa Duração/psicologia , Masculino , Pessoa de Meia-Idade , Sobrepeso/diagnóstico , Sobrepeso/etiologia , Sobrepeso/prevenção & controle , Desempenho Físico Funcional , Estudos Prospectivos
14.
Eur Heart J Cardiovasc Imaging ; 19(5): 532-543, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-28977417

RESUMO

Aim: Presence and consequent extent of infection in patients on continuous-flow left ventricular assist devices (CF-LVADs) can be challenging with the current diagnostic tools. The present study sought to demonstrate the diagnostic power of 18F-Fluorodeoxyglucose-Positron-Emission Tomography/Computed Tomography (18F-FDG PET/CT) in detecting infection in patients supported with CF-LVAD. Background: The present study sought to demonstrate the diagnostic power of 18F-fluorodeoxyglucose-positron-emission tomography/computed tomography (18F-FDG PET/CT) in detecting infection in patients supported with CF-LVAD. Methods and results: Between July 2009 and April 2016, 61 PET/CT examinations were performed in 47 patients (median age 64.13 years, IQR 18.77) supported with a CF-LVAD. PET/CT assessments were performed qualitatively and quantitatively at three different levels: at the piercing site of driveline (first level), along the intracorporeal course of driveline (second level), and around the device (third level). Final diagnosis of LVAD infection was prospectively performed and was based upon microbiological samples taken at hospital admission, during the surgical revision/transplantation and recurrence of symptoms on long-term follow-up. At last follow-up a total of 40 (65.57%) final diagnoses of LVAD-infection could be ascertained. Matching the final diagnosis with the PET/CT assessments the sensitivity, specificity, and positive and negative predictive value were 90.0, 71.4, 85.71, and 78.94%, respectively. Level sub-analyses of SUV max showed an optimal discriminator power for levels 1 and 2 (AUC of level 1-0.824, P < 0.001; AUC of level 2-0.849, P < 0.001, respectively). At the third level semi-quantitative analysis showed poor discriminator power (AUC 0.589, P = 0.33). Qualitative visual analysis instead indicated a trend toward significance (P = 0.07). Conclusions: Quantitative 18F-FDG PET/CT is an optimal diagnostic tool in detecting superficial and deep driveline infections. However, diagnostic accuracy with regard to the diagnosis of pump housing infection is limited. Here, clinical and qualitative PET/CT analyses must be better considered.


Assuntos
Fluordesoxiglucose F18 , Coração Auxiliar/efeitos adversos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/epidemiologia , Intensificação de Imagem Radiográfica , Centros Médicos Acadêmicos , Adulto , Idoso , Antibacterianos/uso terapêutico , Estudos de Coortes , Terapia Combinada , Feminino , Transplante de Coração/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Prognóstico , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/terapia , Curva ROC , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Taxa de Sobrevida , Resultado do Tratamento
16.
Thorac Cardiovasc Surg ; 66(8): 637-644, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-28602018

RESUMO

BACKGROUND: Primary malignant cardiac tumors rarely occur in clinical care. Little is known about the impact of a parameter on postoperative survival. METHODS: From May 1991 to May 2014, a total of 24 patients underwent surgical treatment of a primary cardiac sarcoma in our center. We analyzed our clinical database retrospectively for information on patient characteristics and treatment data. The follow-up could be completed to 91.7%. RESULTS: Angiosarcoma and non-otherwise-specified sarcoma were the most common tumor entities. R0 resection was achieved in most cases. Postoperative mortality within the first 30 days was 20.8% (n = 5). In four of these five cases, postoperative low-output cardiac failure was the leading cause of death. The cumulative survival rate was 77.3% after 30 days, 68.2% after 3 months, 50.0% after 6 months, 45.0% after 12 months, and 18.0% after 24 months. The mean survival time in the whole group was 47.0 months. A low tumor differentiation was associated with low mean survival, but this was not statistically significant. Mean survival of sarcoma was higher after R0 resection. There was no significant rate of survival difference regarding the adjuvant therapy concept. CONCLUSION: Extended surgery alone or in combination with chemo- and/or radiotherapy may be successful in certain cases and may offer a satisfactory quality of life. The establishment of a multicenter heart tumor register in Germany is necessary to increase the number of cases in studies, get more remarkable study results, and standardize the diagnosis and therapy.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Neoplasias Cardíacas/cirurgia , Complicações Pós-Operatórias/etiologia , Sarcoma/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Procedimentos Cirúrgicos Cardíacos/mortalidade , Quimioterapia Adjuvante , Criança , Bases de Dados Factuais , Feminino , Alemanha , Neoplasias Cardíacas/mortalidade , Neoplasias Cardíacas/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Qualidade de Vida , Radioterapia Adjuvante , Estudos Retrospectivos , Fatores de Risco , Sarcoma/mortalidade , Sarcoma/patologia , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
17.
Z Psychosom Med Psychother ; 63(4): 388-404, 2017 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-29214945

RESUMO

Quality of life and mental health of patients with severe heart failure with or without technical support for the left cardiac ventricle - a cross-sectional study Objectives: Chronic heart failure is associated with reduced quality of life (QoL) and poor prognosis. Support via a left ventricular assist device (LVAD) is an alternative to optimised medical management for patients with advanced heart failure. This study evaluated health-related QoL with both therapy options. METHODS: In this consecutive cross-sectional study, patients with LVAD support (n = 50) and patients with optimised medical management (n = 50) were interviewed comprehensively about various domains of QoL, emotional stress, perceived self-efficacy, social support, life satisfaction, and communication. RESULTS: LVAD patients had a better overall QoL (KCCQ, clinical summary: MW: 67.4 vs. 52.9). Patients with medical management reported increased emotional stress stemming from depressed mood (HADS-D, MW: 7.1 vs.MW: 6.0). Depressed mood proved to be the most significant negative predictor for health-related QoL as well as for emotional well-being. CONCLUSIONS: Although they had a worse clinical situation preoperatively, LVAD patients had a significantly better QoL in both physical dimensions and functional competencies as well as significantly less psychological stress through depressed mood and anxiety.


Assuntos
Assistência ao Convalescente/psicologia , Insuficiência Cardíaca/psicologia , Insuficiência Cardíaca/terapia , Coração Auxiliar/psicologia , Transtornos Mentais/psicologia , Complicações Pós-Operatórias/psicologia , Qualidade de Vida/psicologia , Adaptação Psicológica , Comunicação , Estudos Transversais , Humanos , Comunicação Interdisciplinar , Colaboração Intersetorial , Transtornos Mentais/diagnóstico , Equipe de Assistência ao Paciente , Satisfação do Paciente , Complicações Pós-Operatórias/diagnóstico , Autoeficácia , Apoio Social
18.
Eur J Nucl Med Mol Imaging ; 44(11): 1870-1877, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28547176

RESUMO

PURPOSE: A continuous-flow left ventricular assist device (LVAD) is a new and highly promising therapy in supporting end-stage heart failure patients, either bridging them to heart transplantation or as a destination therapy. Infection is one of the major complications associated with LVAD implants. 18F-FDG PET/CT has already been shown to be useful in the detection of LVAD infection. The goal of this study was to compare the diagnostic accuracy of different PET analysis techniques (visual grading versus SUVmax and metabolic volume). METHODS: We retrospectively analyzed 48 patients with implanted LVAD who underwent an 18F-FDG PET/CT that were either suspected to have a driveline or device infection or inflammation of unknown origin. PET/CT was analyzed qualitatively (visual grading) and quantitatively (SUVmax and metabolic volume) and matched to the final clinical diagnosis concerning driveline infection. The final diagnosis (standard of reference) was made at the end of clinically recorded follow-up or transplantation and included microbiological cultures of the driveline exit site and/or surgical samples, and clinical signs of infection despite negative cultures as well as recurrence of symptoms. RESULTS: Sensitivity, specificity, positive and negative predictive value were 87.5%, 79%, 81% and 86% for visual score, 87.5%, 87.5%, 87.5% and 87.5% for SUVmax and 96%, 87.5%, 88.5%, 95.5% for metabolic volume, respectively. ROC analysis revealed an AUC of .929 for SUVmax and .969 for metabolic volume. Both SUVmax and metabolic volume had a high detection rate of patients with driveline infection (21/24 = 91.5% true positive vs. 23/26 = 88.5% true positive, respectively). However, metabolic volume detected more patients without any infection correctly (1/22 = 4.5% false negative vs. 3/24 = 12.5% false negative). CONCLUSIONS: 18F-FDG PET/CT is a valuable tool for the diagnosis of LVAD driveline infection with high diagnostic accuracy. Particularly the use of the metabolic volume yields very high accuracy and performs slightly better than SUVmax.


Assuntos
Fluordesoxiglucose F18/farmacocinética , Coração Auxiliar/efeitos adversos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Infecções Relacionadas à Prótese/diagnóstico por imagem , Compostos Radiofarmacêuticos/farmacocinética , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/normas , Sensibilidade e Especificidade
19.
Minerva Med ; 108(4): 299-304, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28326754

RESUMO

BACKGROUND: The aim of the current study was to evaluate the role of PET-CT in the diagnosis of prosthetic valve endocarditis (PVE). METHODS: This is a single-center study including 13 PET/CT examinations performed between February 2009 and March 2016 in 13 patients (76.9% men, mean age 68.1 years, IQR 11.1) because of suspect of PVE. Median interval time between first operation and PET/CT examination was 19.02 months (IQR 85.5). Final diagnosis was made according to pathological criteria (histological and microbiological) of the Duke classification. RESULTS: Eleven patients (84.6%) presented at the hospital admission positive blood cultures. Eight patients (61.5%) had inconclusive transesophageal echocardiography (TEE). Abnormal 18F-FDG uptake suggestive of active PVE was observed in 10 patients (76.9%), whereas in 3 patients (23.1%) PET/CT did not show any pathological tracer uptake at the level of the previous implanted prostheses. PET/CT revealed 15 (115.4%) new extracardiac findings and one (7.7%) new cardiac focus not previously detected in TEE. All patients underwent redo surgery. Matching the intraoperative findings with those of PET/CT, a total of 10 true positives, 2 true negatives, no false positive and 1 false negative finding was reported. Sensitivity, specificity, and positive and negative predictive values of PET/CT were 90.9%, 100%, 100% and 50% whereas for TEE they were 81.82%, 50%, 81.82%, and 50% respectively. In 61.63% of patients (N. 8) PET/CT and echo findings were concordant. In those cases the diagnosis of endocarditis was confirmed in all. CONCLUSIONS: This study highlights the potential advantages of PET-CT in patients with suspected prosthesis endocarditis. Further prospective evaluations are needed to confirm those preliminary results.


Assuntos
Endocardite/diagnóstico por imagem , Endocardite/microbiologia , Fluordesoxiglucose F18 , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas/efeitos adversos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Compostos Radiofarmacêuticos , Idoso , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA