Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Vestn Oftalmol ; 133(1): 81-87, 2017.
Artigo em Russo | MEDLINE | ID: mdl-28291205

RESUMO

The present review covers the use of chorioretinal photocoagulation, which is now a popular treatment for many diseases of the ocular fundus. The review includes a detailed 50-year history of the technology with account to both Russian and foreign achievements. The current state of the field is shown through Russian and foreign literature data. A particular emphasis is placed on subthreshold, pattern, and navigated techniques. Breakthrough solutions, such as optoacoustic monitoring, that ensure high precision of the procedure, maximum saving of tissues, and high therapeutic effectiveness are described.


Assuntos
Oftalmopatias/terapia , Terapia a Laser/métodos , Oftalmopatias/diagnóstico , Fundo de Olho , Humanos , Oftalmoscopia/métodos , Pupila , Federação Russa
2.
Vestn Oftalmol ; 130(2): 37-42, 2014.
Artigo em Russo | MEDLINE | ID: mdl-24864498

RESUMO

The article studies application possibilities and potency of near infrared coagulative radiation of a diode laser for correction of postoperative iris defects followed by pupillary deformities and displacement. It is found that the use of near infrared diode laser radiation at 0.810 microm enables visual improvement through pupil enlargement or its shift to the optical centre. The use of the wavelength specified does not cause severe atrophic or cosmetic changes in the iris.


Assuntos
Raios Infravermelhos/uso terapêutico , Iris/cirurgia , Fotocoagulação a Laser/métodos , Lasers Semicondutores/uso terapêutico , Procedimentos de Cirurgia Plástica , Complicações Pós-Operatórias/cirurgia , Pseudofacia/cirurgia , Distúrbios Pupilares/cirurgia , Humanos , Iris/fisiopatologia , Distúrbios Pupilares/fisiopatologia , Acuidade Visual
3.
J Biomech ; 46(10): 1648-54, 2013 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-23680349

RESUMO

Currently, investigations of biomechanical properties of the fibrous tunic are becoming even more topical, especially for diagnosis of corneal ectatic disease, as well as correct interpretation of intraocular pressure (IOP) parameters, particularly in patients with prior surgery on cornea. The study principle is based on the ability of substances to change optical anisotropy depending on mechanical strain applied to them. An experimental set-up was constructed which allows assessment of polarization degree of light which is emitted during luminescence of strained collagen. The study was performed on 18 corneoscleral discs of chinchilla rabbit eyes at 15 and 50mm Hg pressure, among them in 6 cases before and after making radial incisions, and in 6 cases before and after conducting the mechanical cornea abrasions that were asymmetrical by depth until reaching the local zone of iatrogenic keratectasia. Corneal collagen mechanical strain mappings were formed on 3 experimental models (intact cornea, cornea post radial keratotomy and keratectasia) under intra-chamber pressure of 15 and 50mm Hg. Corneal collagen mechanical strain is evenly allocated in the intact cornea. After radial keratotomy the main mechanical loading was concentrated over the middle part of corneal periphery, particularly in the bottom of keratotomic incisions. The increased intra-chamber pressure made the strain rise in those models. Upon cornea abrasion the main straining is distributed within the thinning zone, and the increase of intra-chamber pressure only increases the load over residual stroma. A new principle of corneal biomechanical properties investigation based on assessment of degree of light polarization emitted during luminescence of strained collagen, has been proposed and experimentally tested.


Assuntos
Colágeno/fisiologia , Substância Própria/fisiologia , Animais , Fenômenos Biomecânicos , Luminescência , Pressão , Coelhos , Estresse Mecânico
4.
Vestn Oftalmol ; 127(4): 49-56, 2011.
Artigo em Russo | MEDLINE | ID: mdl-21882642

RESUMO

The features of interaction of laser radiation with iris tissue were determined in experimental morphological study. The potential of laser irradiation with different spectral characteristics for pupil ectopia correction is estimated. The results of morphometry showed effectiveness of near-infrared diode laser radiation, that presents as an iris contraction in coagulation region with minimal tissue trauma. This fact allows us to propose a near-infrared diode laser radiation as a treatment option for correction of pupil form and location. Alternatively visible wave-length laser showed to be less effective and more traumatic.


Assuntos
Iris , Fotocoagulação a Laser , Lasers Semicondutores/uso terapêutico , Terapia com Luz de Baixa Intensidade , Distúrbios Pupilares/radioterapia , Distúrbios Pupilares/cirurgia , Animais , Biometria , Técnicas Histológicas , Humanos , Raios Infravermelhos/efeitos adversos , Raios Infravermelhos/uso terapêutico , Iris/patologia , Iris/efeitos da radiação , Fotocoagulação a Laser/efeitos adversos , Fotocoagulação a Laser/classificação , Fotocoagulação a Laser/instrumentação , Lasers Semicondutores/efeitos adversos , Lasers Semicondutores/normas , Terapia com Luz de Baixa Intensidade/efeitos adversos , Terapia com Luz de Baixa Intensidade/classificação , Terapia com Luz de Baixa Intensidade/instrumentação , Microscopia Acústica , Distúrbios Pupilares/patologia , Coelhos , Projetos de Pesquisa , Resultado do Tratamento
5.
Vestn Oftalmol ; 127(3): 3-5, 2011.
Artigo em Russo | MEDLINE | ID: mdl-21800715

RESUMO

The degree of impact of several fibrous tunic biomechanical parameters on biomechanical indices was studied using multifactor correlation analysis. In patients with "normal" cornea corneal thickness was found to be the most significant factor influencing corneal hysteresis, corneal resistance factor, elasticity coefficient and elasticity rise, hence values of corneal biomechanical properties prevail over all other biomechanical indices studied in this work. However influence of significant changes in scleral biomechanics (e. g. in high myopia) on these factors (especially corneal hysteresis and elasticity rise) can not be excluded.


Assuntos
Córnea/anatomia & histologia , Córnea/fisiologia , Esclera/anatomia & histologia , Esclera/fisiologia , Adolescente , Adulto , Fenômenos Biomecânicos , Biometria , Elasticidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Refração Ocular , Adulto Jovem
6.
Vestn Oftalmol ; 127(3): 5-7, 2011.
Artigo em Russo | MEDLINE | ID: mdl-21800716

RESUMO

The potential relation of biomechanical indices with topographic features in keratoconus was studied using multifactor correlation analysis. Topographic features in keratoconus were found to have influence on biomechanical measurements in the central zone of the cornea. If the zone of ectasia is distant from the central part of the cornea the central biomechanics can remain normal. Elasticity coefficient was found to be the most sensitive and keratoconus topography-dependent biomechanical index compared with other biomechanical parameters studied in this work.


Assuntos
Ceratocone/patologia , Ceratocone/fisiopatologia , Esclera/patologia , Esclera/fisiopatologia , Adulto , Fenômenos Biomecânicos , Córnea/patologia , Córnea/fisiopatologia , Feminino , Humanos , Masculino , Refração Ocular , Adulto Jovem
7.
Vestn Oftalmol ; 127(2): 56-8, 2011.
Artigo em Russo | MEDLINE | ID: mdl-21721278

RESUMO

The results of development of test device for estimation of viscoelactic properties of biological tussues are presented. Special software provides opportunity to make a graph representing intension within tested material. A high correlation between acoustic density and lens viscoelactic properties was found when isolated lenses after extracapsular cataract extraction were tested.


Assuntos
Catarata/diagnóstico , Técnicas de Imagem por Elasticidade/instrumentação , Cristalino/fisiopatologia , Animais , Catarata/fisiopatologia , Modelos Animais de Doenças , Elasticidade , Desenho de Equipamento , Coelhos , Reprodutibilidade dos Testes
8.
Vestn Oftalmol ; 126(2): 27-30, 2010.
Artigo em Russo | MEDLINE | ID: mdl-21105375

RESUMO

The current methods widely used in ophthalmology to examine patients to diagnose the dry eye syndrome and to trace the course of a process are invasive. Both the Norn test using stains and the Schirmer test with the filter paper strips being inserted are stimuli that affect the rate of tear generation, which misrepresents the data obtainable. The developed procedures for examining the eye in polarized light permit one to considerably reduce the invasiveness of patient examination. The study indicated the high efficiency and diagnostic value of the proposed procedures in the examination of patients with the dry eye syndrome. Polarization filters available in the standard kit of up-to-date slit lamps make it possible to use the proposed procedures without any modification of ophthalmological equipment in wide clinical practice.


Assuntos
Técnicas de Diagnóstico Oftalmológico , Síndromes do Olho Seco/diagnóstico , Adulto , Idoso , Síndromes do Olho Seco/patologia , Diagnóstico Precoce , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
9.
Vestn Oftalmol ; 124(5): 25-8, 2008.
Artigo em Russo | MEDLINE | ID: mdl-19062554

RESUMO

A new principle in the determination of mechanical stress distribution in the cornea is proposed on the basis of estimation of the polarization of light emitted by luminescence of strained collagen. It has been found, collagen fiber stress is inversely proportional to corneal stress on the intact cornea of a rabbit, and absolute values are determined by intraocular pressure values. After applying keratotomic incisions, the stress distribution map changes, at the same time, the major stress falls on the residual thickness of the stroma at the bottom of a keratotomic scar and close to this area and the central corneal region is subject to the least pressure.


Assuntos
Córnea/fisiologia , Pressão Intraocular/fisiologia , Estresse Mecânico , Animais , Fenômenos Biomecânicos , Cicatriz , Colágeno/metabolismo , Colágeno/fisiologia , Córnea/metabolismo , Córnea/cirurgia , Substância Própria/fisiologia , Topografia da Córnea , Polarização de Fluorescência , Ceratotomia Radial , Luminescência , Coelhos , Tonometria Ocular
10.
Vestn Oftalmol ; 124(5): 22-4, 2008.
Artigo em Russo | MEDLINE | ID: mdl-19062553

RESUMO

This study deals with the biomechanical properties of the cornea, which is essential in solving different problems of clinical ophthalmology, specifically in predicting the potential complications of keratorefraction operations, in early diagnosing keratoconus, and interpreting the measurements of intraocular pressure. The investigations confirmed the efficiency of using bidirectional applanation of the cornea to define its strength characteristics. A procedure has been also developed to estimate the elasticity coefficient which reflects the elastic properties of the cornea irrespective of intraocular pressure values.


Assuntos
Córnea/fisiologia , Pressão Intraocular/fisiologia , Ceratocone/diagnóstico , Hipertensão Ocular/diagnóstico , Tonometria Ocular/métodos , Adolescente , Adulto , Anti-Hipertensivos/uso terapêutico , Fenômenos Biomecânicos , Córnea/fisiopatologia , Topografia da Córnea , Transplante de Córnea , Elasticidade , Humanos , Ceratocone/cirurgia , Pessoa de Meia-Idade , Modelos Biológicos , Hipertensão Ocular/tratamento farmacológico
12.
Vestn Oftalmol ; 121(5): 19-21, 2005.
Artigo em Russo | MEDLINE | ID: mdl-16274058

RESUMO

To study the capacities of ophthalmological application of the photosensitizer Radachlorine (0.35% solution for intravenous injection), the authors carried out a series of in vivo experiments on rabbits. They studied the time parameters of distribution of the agent in the chorioretinal complex and the reaction of newly formed vessels to photodynamic therapy. Radiation of a diode laser at a wavelength of 0.662 microm was used to stimulate the photosensitizer. A video micro-camera adapted to the ocular of a split lamp was applied to fluorescence fixation. Superficial corneal vascularization was used as a model of the neovascular membrane in response to the application of a non-penetrating silk suture. The findings suggest that photodynamic therapy using Radachlorine is safe and effective in treating ocular tissue neovascularization.


Assuntos
Oftalmopatias/tratamento farmacológico , Fotoquimioterapia , Porfirinas/uso terapêutico , Radiossensibilizantes/uso terapêutico , Animais , Clorofilídeos , Neovascularização de Coroide/tratamento farmacológico , Neovascularização da Córnea/tratamento farmacológico , Modelos Animais de Doenças , Fluorescência , Injeções Intravenosas , Lasers , Porfirinas/administração & dosagem , Coelhos , Radiossensibilizantes/administração & dosagem , Neovascularização Retiniana/tratamento farmacológico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA