1.
J Craniofac Surg ; 30(2): 539-540, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30640854

RESUMO

Porous alloplastic materials such as titanium mesh and porous polyethylene allow for the ingrowth of fibrovascular tissues into the implant; stabilizing the implant and reducing the risk of extrusion and extrusion-related complications (such as hematoma formation). The literature contains 2 specific reports of delayed atraumatic orbital hematomas occurring 8 months and 3 years after orbital floor reconstruction with porous polyethylene implants. In this study, an atraumatic orbital hematoma occurring 16 years after orbital floor reconstruction with a porous polyethylene implant was presented. The hematoma was evacuated and the implant was removed without replacement of a secondary implant. The remaining fibrovascular tissue on the underside of the implant provided enough support of the orbital soft tissues to achieve excellent anatomic and physiologic outcomes.


Assuntos
Hematoma/etiologia , Órbita/lesões , Fraturas Orbitárias/cirurgia , Implantes Orbitários/efeitos adversos , Diplopia/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Órbita/cirurgia , Polietileno , Porosidade , Fatores de Tempo