Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J AOAC Int ; 86(4): 623-30, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-14509417

RESUMO

A convenient method was developed for determination of sulfathiazole (STZ) in Type C medicated swine feed by reversed-phase liquid chromatography (LC) with post-column derivatization. Addition of extractant solution (0.2N HCl and 1.5% diethylamine in 25% methanol) and an internal standard (IS), sulfamethylthiazole (SMZ), to 5 g sample was followed by mechanical shaking for 1 h. The extract was clarified by chilling, centrifugation, and filtering before injection onto a C18 reversed-phase column. The mobile phase components were 2% acetic acid and 1:1 acetonitrile-methanol (83 + 17%, v/v). Run time was about 20 min. Determination and, largely, the method's selectivity were based on detection at 450 nm of the derivative formed by the post-column reaction of dimethylaminobenzaldehyde with the primary amine of the analyte and IS. The IS, SMZ, differs from STZ by a single substituent methyl group, is stable, and is readily resolved from STZ. Although SMZ is not commercially available, it can be synthesized with relative ease from purchased reagents and will be supplied by the authors to interested laboratories. In single-laboratory validation, linearity was demonstrated over the range of 0.055-550 microg/mL, well beyond the target concentration of 5.5 microg/mL. The estimated limit of detection was 0.04 microg/mL; the calculated limit of quantitation was 0.13 microg/mL (feed concentration of 2.4 g/T or 2.7 mg/kg). Wet-spiking trials with a variety of swine feed matrixes showed recovery to be 100-102% for the intended concentration range, 50-200 g/T, with coefficient of variation (CV) < 2%. The method ruggedness was verified with an overall CV of 2.9%.


Assuntos
Ração Animal/análise , Anti-Infecciosos/análise , Cromatografia Líquida de Alta Pressão/métodos , Sulfatiazóis/análise , Suínos , Animais , Indicadores e Reagentes , Controle de Qualidade , Sensibilidade e Especificidade , Sulfatiazol , Sulfatiazóis/administração & dosagem
2.
J AOAC Int ; 86(2): 197-201, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12723905

RESUMO

A method for determination of riboflavin in animal feeds using liquid chromatography (LC) was developed for feed samples fortified with riboflavin at 1 mg/lb or greater (up to 10,000 mg/lb). Feed samples were extracted in 0.1 N HCl with heating on a steam bath for 30 min, followed immediately by mechanical shaking for 30 min. Sample extracts were diluted to target volume with 2% acetic acid and filtered; riboflavin was determined by LC on a reversed-phase C18 column with 2% acetic acid-acetonitrile (85 + 15) mobile phase for separation and fluorescence detection with excitation at 460 nm and emission at 530 nm. The extraction was compared with that of the AOAC Official Method for riboflavin in food and feed premixes. The 2 method extractions were not significantly different from each other at the 95% confidence level. The developed method also had good linearity over 4 orders of magnitude, recovery of 95-99% from spiked feed samples, a limit of detection of riboflavin at 0.00034 microg/mL in solution, a limit of quantitation of 0.023 mg/lb in feed, and good ruggedness.


Assuntos
Ração Animal/análise , Riboflavina/análise , Algoritmos , Cromatografia Líquida , Indicadores e Reagentes , Padrões de Referência , Reprodutibilidade dos Testes
3.
J AOAC Int ; 85(3): 533-40, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12083243

RESUMO

An improved method for extraction and analysis of tiamulin is presented to address issues that arose during routine analysis of Type C medicated swine feeds under the current U.S. Food and Drug Administration-Center for Veterinary Medicine (FDA-CVM) approved method. The issues included the need for higher sample throughput and the ability to accommodate a wider variety of feed matrixes. Changes to the FDA-CVM approved method include reduced sample size and solvent volumes, phosphate buffering of tartaric acid, centrifugation, and use of a new liquid chromatography column and adjusted mobile phase composition. A paired sample study was performed to compare performance of the new and existing methods. The paired sample study showed no statistical difference between sample means of paired sets of 17 samples analyzed by both methods (t = 1.95 at 0.05 significance level, p = 0.068). A recovery study showed the method precision to be 2.06% (coefficient of variation) with an average standard recoveryof 95.8%. Ruggedness test results indicated good overall ruggedness of the method.


Assuntos
Ração Animal/análise , Cromatografia Líquida/métodos , Diterpenos/análise , Animais , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA