Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Micromachines (Basel) ; 15(1)2023 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-38258146

RESUMO

Using devices with microfluidic channels can allow for precise control over liquids flowing through them. Merging flows of immiscible liquids can create emulsions with highly monodispersed microdroplets within a carrier liquid, which are ideal for miniaturised reaction vessels which can be generated with a high throughput of tens of thousands of droplets per second. Control of the size and composition of these droplets is generally performed by controlling the pumping system pushing the liquids into the device; however, this is an indirect manipulation and inadequate if absolute precision is required in the size or composition of the droplets. In this work, we extend the previous development of image-based closed-loop feedback control over microdroplet generation to allow for the control of not only the size of droplets but also the composition by merging two aqueous flows. The feedback allows direct control over the desired parameters of volume and ratio of the two components over a wide range of ratios and outperforms current techniques in terms of monodispersity in volume and composition. This technique is ideal for situations where precise control over droplets is critical, or where a library of droplets of different concentrations but the same volume is required.

2.
Anal Chem ; 92(18): 12605-12612, 2020 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-32786490

RESUMO

High- and ultrahigh-throughput label-free sample analysis is required by many applications, extending from environmental monitoring to drug discovery and industrial biotechnology. HTS methods predominantly are based on a targeted workflow, which can limit their scope. Mass spectrometry readily provides chemical identity and abundance for complex mixtures, and here, we use microdroplet generation microfluidics to supply picoliter aliquots for analysis at rates up to and including 33 Hz. This is demonstrated for small molecules, peptides, and proteins up to 66 kDa on three commercially available mass spectrometers from salty solutions to mimic cellular environments. Designs for chip-based interfaces that permit this coupling are presented, and the merits and challenges of these interfaces are discussed. On an Orbitrap platform droplet infusion rates of 6 Hz are used for analysis of cytochrome c, on a DTIMS Q-TOF similar rates were obtained, and on a TWIMS Q-TOF utilizing IM-MS software rates up to 33 Hz are demonstrated. The potential of this approach is demonstrated with proof of concept experiments on crude mixtures including egg white, unpurified recombinant protein, and a biotransformation supernatant.


Assuntos
Dispositivos Lab-On-A-Chip , Peptídeos/análise , Proteínas/análise , Bibliotecas de Moléculas Pequenas/análise , Espectrometria de Massas , Tamanho da Partícula , Software , Propriedades de Superfície
3.
Analyst ; 144(3): 872-891, 2019 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-30601490

RESUMO

High throughput screening (HTS) of molecular analytes is in high demand from and implemented in many areas of chemistry, medicine and industrial biotechnology including the discovery of biomarkers and the development of new chemical entities. Despite its prevalence, technical challenges remain in many of the new application areas of HTS which require rapid results from complex mixtures, for example in: screening biotransformations; targeted metabolomics; and in locating drugs and/or metabolites in biological matrices. Common to all of these are lengthy and costly sample preparation stages, involving recovery from cell cultures, extractions followed by low throughput LC-MS/MS methods or specific fluorescence measurements. In the latter the target molecules need to be inherently fluorescent or to include a fluorescent label or tag which can adversely influence a cellular system. Direct infusion mass spectrometry coupled with robotic sample infusion is a viable contender for information rich HTS with sub-second analysis times, and recent developments in ambient ionisation have heralded a new era where screening can be performed on crude cell lysates or even from live cells. Besides commercially available technologies such as RapidFire, Acoustic Mist Ionisation, and the TriVersa ChipMate there are promising new developments from academic groups. Novel applications using desorption electrospray ionisation, microfluidics, rapid LC-separation and 'one cell' direct infusion methods offer much potential for increasing throughput from 'messy' complex samples and for significantly reducing the amount of material that needs to be analysed. Here we review recent advances in HTS coupled with MS with an emphasis on methods that reduce or remove all sample preparation and will facilitate single cell screening approaches.


Assuntos
Ensaios de Triagem em Larga Escala/métodos , Substâncias Macromoleculares/análise , Espectrometria de Massas/métodos , Análise de Célula Única/métodos , Humanos
4.
Small ; 12(13): 1788-96, 2016 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-26865562

RESUMO

Microfluidic microdroplets have increasingly found application in biomolecular sensing as well as nanomaterials growth. More recently the synthesis of plasmonic nanostructures in microdroplets has led to surface-enhanced Raman spectroscopy (SERS)-based sensing applications. However, the study of nanoassembly in microdroplets has previously been hindered by the lack of on-chip characterization tools, particularly at early timescales. Enabled by a refractive index matching microdroplet formulation, dark-field spectroscopy is exploited to directly track the formation of nanometer-spaced gold nanoparticle assemblies in microdroplets. Measurements in flow provide millisecond time resolution through the assembly process, allowing identification of a regime where dimer formation dominates the dark-field scattering and SERS. Furthermore, it is shown that small numbers of nanoparticles can be isolated in microdroplets, paving the way for simple high-yield assembly, isolation, and sorting of few nanoparticle structures.


Assuntos
Nanopartículas Metálicas/química , Microfluídica/métodos , Fenômenos Ópticos , Análise Espectral Raman/métodos , Ouro/química , Refratometria
5.
Adv Funct Mater ; 25(26): 4091-4100, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26213532

RESUMO

Supramolecular self-assembly offers routes to challenging architectures on the molecular and macroscopic scale. Coupled with microfluidics it has been used to make microcapsules-where a 2D sheet is shaped in 3D, encapsulating the volume within. In this paper, a versatile methodology to direct the accumulation of capsule-forming components to the droplet interface using electrostatic interactions is described. In this approach, charged copolymers are selectively partitioned to the microdroplet interface by a complementary charged surfactant for subsequent supramolecular cross-linking via cucurbit[8]uril. This dynamic assembly process is employed to selectively form both hollow, ultrathin microcapsules and solid microparticles from a single solution. The ability to dictate the distribution of a mixture of charged copolymers within the microdroplet, as demonstrated by the single-step fabrication of distinct core-shell microcapsules, gives access to a new generation of innovative self-assembled constructs.

6.
ACS Nano ; 7(7): 5955-64, 2013 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-23805985

RESUMO

We report a microfluidic droplet-based approach enabling the measurement of chemical reactions of individual enzyme molecules and its application to a single-molecule-counting immunoassay. A microfluidic device is used to generate and manipulate <10 fL droplets at rates of up to 1.3 × 10(6) per second, about 2 orders of magnitude faster than has previously been reported. The femtodroplets produced with this device can be used to encapsulate single biomolecular complexes tagged with a reporter enzyme; their small volume enables the fluorescent product of a single enzyme molecule to be detected within 10 min of on-chip incubation. Our prototype system is validated by detection of a biomarker for prostate cancer in buffer, down to a concentration of 46 fM. This work demonstrates a highly flexible and sensitive diagnostic platform that exploits extremely high-speed generation of monodisperse femtoliter droplets for the counting of individual analyte molecules.


Assuntos
Técnicas Biossensoriais/instrumentação , Imunoensaio/instrumentação , Microquímica/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/sangue , Neoplasias da Próstata/diagnóstico , Biomarcadores/análise , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Masculino , Nanomedicina/instrumentação
7.
Anal Chem ; 85(8): 3812-6, 2013 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-23514243

RESUMO

Droplet-based fluidics is emerging as a powerful platform for single cell analysis, directed evolution of enzymes, and high throughput screening studies. Due to the small amounts of compound compartmentalized in each droplet, detection has been primarily by fluorescence. To extend the range of experiments that can be carried out in droplets, we have developed the use of electrospray ionization mass spectrometry (ESI-MS) to measure femtomole quantities of proteins in individual pico- to nanoliter droplets. Surfactant-stabilized droplets containing analyte were produced in a flow-focusing droplet generation microfluidic device using fluorocarbon oil as the continuous phase. The droplets were collected off-chip for storage and reinjected into microfluidic devices prior to spraying the emulsion into an ESI mass spectrometer. Crucially, high quality mass spectra of individual droplets were obtained from emulsions containing a mixture of droplets at >150 per minute, opening up new routes to high throughput screening studies.


Assuntos
Ensaios de Triagem em Larga Escala/métodos , Técnicas Analíticas Microfluídicas/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Anidrases Carbônicas/análise , Quimotripsinogênio/análise , Citocromos c/análise , Emulsões , Análise de Injeção de Fluxo , Fluorocarbonos/química , Ensaios de Triagem em Larga Escala/instrumentação , Óleos Industriais , Técnicas Analíticas Microfluídicas/instrumentação , Muramidase/análise , Nanotecnologia , Espectrometria de Massas por Ionização por Electrospray/instrumentação , Tensoativos/química
8.
Bioorg Med Chem Lett ; 17(14): 3972-7, 2007 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-17502144

RESUMO

A potent and selective series of 2-amino-3,5-diarylbenzamide inhibitors of IKK-alpha and IKK-beta is described. The most potent compounds are 8h, 8r and 8v, with IKK-beta inhibitory potencies of pIC(50) 7.0, 6.8 and 6.8, respectively. The series has excellent selectivity, both within the IKK family over IKK-epsilon, and across a wide variety of kinase assays. The potency of 8h in the IKK-beta enzyme assay translates to significant cellular activity (pIC(50) 5.7-6.1) in assays of functional and mechanistic relevance.


Assuntos
Benzamidas/farmacologia , Inibidores Enzimáticos/farmacologia , Quinase I-kappa B/antagonistas & inibidores , Benzamidas/química , Inibidores Enzimáticos/química , Ligação de Hidrogênio , Modelos Moleculares
9.
Org Biomol Chem ; 3(15): 2701-12, 2005 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-16032348

RESUMO

Highly-functionalised difluorinated cyclooctenones were synthesised from trifluoroethanol using either metallated difluoroenol acetal or carbamate chemistry, followed by a [2,3]-Wittig rearrangement or aldol reaction. Efficient RCM reactions afforded the title compounds which showed rather restricted fluxional behaviour by VT (19)F NMR. Topological characterisation by molecular modelling and NOESY/ROESY experiments offered a number of challenges, but allowed the identification of two favoured boat-chair conformers which interconverted by pseudorotation with relatively large activation barriers.


Assuntos
Carboidratos/química , Flúor/química , Hidrocarbonetos Aromáticos/química , Hidrocarbonetos Aromáticos/síntese química , Mimetismo Molecular , Espectroscopia de Ressonância Magnética , Modelos Moleculares , Conformação Molecular , Espectrometria de Massas de Bombardeamento Rápido de Átomos
10.
Org Lett ; 7(5): 843-6, 2005 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-15727455

RESUMO

The use of the pentafluorophenyl (PFP) group as a sulfonic acid protecting group has allowed the synthesis of new biaryl- and heterobiaryl-PFP-sulfonate esters by use of the Suzuki-Miyaura reaction. The successful employment of a novel inorganic base, anhydrous sodium tetraborate, was crucial to give the products in excellent yields. The PFP-sulfonate ester has been previously shown to be an excellent alternative to sulfonyl chlorides in the synthesis of sulfonamides. [structure: see text]

11.
Chem Commun (Camb) ; (13): 1526-7, 2004 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-15216363

RESUMO

A (bromodifluoromethyl)alkyne has been deployed in a stereoselective route to difluorinated aldonic acid analogues, in which a Sharpless asymmetric dihydroxylation reaction and diastereoisomer separation set the stage for phenyl group oxidation.

12.
Org Biomol Chem ; 2(4): 528-41, 2004 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-14770232

RESUMO

4-Deoxy-4,4-difluoro-glycosides have been synthesised for the first time via a direct sequence involving ring-closing metathesis and indium-mediated difluoroallylation with 1-bromo-1,1-difluoropropene in water. Two protecting group strategies were explored, one to allow protection of the primary C-6 hydroxyl group throughout the sequence, while the second was intended to allow deprotection after RCM and before dihydroxylation. The benzyl ether could be used in the first role, and pivaloyl is effective in the second. Dihydroxylations were highly stereoselective and controlled by the orientation of the glycosidic C-O bond.


Assuntos
Compostos de Flúor/síntese química , Glicosídeos/síntese química , Modelos Moleculares , Estrutura Molecular
13.
Chem Commun (Camb) ; (3): 302-3, 2004 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-14740048

RESUMO

Difluorinated cyclooctenones, synthesised using RCM, can be used as templates for stereoselective oxidative transformations to products that undergo transannular reactions to afford conformationally-locked analogues of 2-deoxy-2,2-difluorosugars with different stereochemical relationships between the C-2 and C-3 hydroxyl groups.


Assuntos
Desoxiaçúcares/química , Flúor/química , Configuração de Carboidratos , Ciclização , Hidroxilação , Estereoisomerismo
14.
Chem Commun (Camb) ; (3): 228-9, 2002 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-12120378

RESUMO

Building block methodology from trifluoroethanol and ring-closing metathesis using a Fürstner modification of Grubbs' conditions allows the rapid synthesis of novel difluorinated cyclooctenones.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA