Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Intern Med J ; 53(11): 2123-2127, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37997271

RESUMO

A review of laboratory results across New Zealand for therapeutic drug monitoring (TDM) of infliximab and adalimumab concentrations and antidrug antibodies (ADAs) over 4 years was completed. Of 6591 results, the median serum concentration for infliximab was 5.7 mg/L and for adalimumab was 5.5 mg/L. Subtherapeutic drug concentrations (<7 mg/L) were measured in 54% of samples. Drug concentrations <2 mg/L were measured in 23% of samples, with ADAs detected in 51% of these. The high number of samples with subtherapeutic drug concentrations and common ADA detection is consistent with failing therapy but could also suggest that standard dosing is frequently too low for patients. These results reinforce the value of antitumour necrosis factor drug TDM in making decisions to adjust dosing or switch agents in patients taking infliximab and adalimumab.


Assuntos
Adalimumab , Infliximab , Humanos , Adalimumab/uso terapêutico , Monitoramento de Medicamentos/métodos , Infliximab/uso terapêutico , Nova Zelândia , Laboratórios
3.
J Immunol Methods ; 474: 112672, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31525368

RESUMO

Adalimumab is a TNF specific monoclonal widely used therapeutically. Monitoring adalimumab levels is important for guiding treatment strategies and is predominantly performed using an ELISA. The homogeneous mobility shift assay (HMSA) has many advantages over an ELISA for adalimumab monitoring but current HMSA methodologies do not discriminate between adalimumab and other TNF specific monoclonals such as infliximab. The development and validation of a competitive binding HMSA (cHMSA) specific for adalimumab is reported here. The cHMSA had a lower limit of quantitation of 1.25 µg/ml and the intra-assay and inter-assay coefficents of variation (CV) were <20%. No signal was detected in adalimumab naïve control serum including those containing rheumatoid factor or infliximab. The majority (14/20) of adalimumab patient samples containing anti-adalimumab antibodies gave a cHMSA signal >3 standard deviations lower than the controls. The performance of the cHMSA and an ELISA was compared using adalimumab patient samples (n = 82). There was a strong correlation between the assays (r = 0.91) and the intra-class correlation coefficient (0.88) was indicative of good-excellent inter-assay reliability. Bland-Altman plots showed little overall bias and comparison of the sub-groups defined using cut-points (1.25 or 7.3 µg/ml) gave percent agreement (>90%) and Cohens kappa (95% CI: 0.61-0.93) values indicative of substantial-almost perfect agreement. These results demonstrate that cHMSA provides an accurate and specific method for monitoring adalimumab levels and can additionally provide an initial screen for the presence of anti-adalimumab antibodies.


Assuntos
Adalimumab/sangue , Monitoramento de Medicamentos/métodos , Ensaio de Desvio de Mobilidade Eletroforética , Inibidores do Fator de Necrose Tumoral/sangue , Ensaio de Imunoadsorção Enzimática , Humanos , Limite de Detecção , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
4.
Ther Drug Monit ; 40(6): 705-715, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30439789

RESUMO

BACKGROUND: The measurement of anti-drug antibody (ADA) levels in adalimumab (ADAL)-treated and infliximab (IFX)-treated patients is critical for guiding therapeutic strategies. The homogeneous mobility shift assay (HMSA) and affinity capture elution (ACE) assay provide effective, drug-tolerant formats for measuring total ADA levels. However, their ability to discriminate between ADA from samples with or without neutralizing capacity is unclear and therefore was analyzed in this study. METHODS: Sera from ADAL and IFX patients with low drug levels (<1 mcg/mL) were analyzed by ACE, HMSA, and bridging assay. Neutralizing capacity was determined by competitive ligand-binding assay. RESULTS: HMSA and ACE detected high ADA levels in all ADAL (19/42) and IFX (27/64) samples with neutralizing capacity. ADA was also detected in most of the samples without neutralizing capacity, but levels were significantly lower (P < 0.0001). Receiver operator characteristic curve analysis demonstrated that for both assays, ADA levels were a strong discriminatory marker of neutralizing ADA (area under the curve > 0.9, P < 0.0001). Using a signal >8× background as a cut-point, neutralizing ADA could be identified with high specificity (HMSA > 95%, ACE > 85%) and sensitivity (HMSA > 70%, ACE > 80%). The detection of multimeric drug-ADA complexes after HMSA was also a highly specific marker (specificity > 95%) of neutralizing ADA in both ADAL and IFX patients. Results using ACE and HMSA were highly correlated. CONCLUSIONS: Results obtained after HMSA and ACE analysis are strongly correlated, and in both assays, high ADA levels are a specific marker of neutralizing capacity. The detection of multimeric complexes by HMSA also selectively identifies sera with neutralizing capacity. These data support the use of these assays as quantitative rather than simple qualitative measures of ADA.


Assuntos
Adalimumab/imunologia , Anticorpos Neutralizantes/sangue , Ensaio de Desvio de Mobilidade Eletroforética/métodos , Ensaio de Imunoadsorção Enzimática/métodos , Infliximab/imunologia , Adolescente , Adulto , Idoso , Anticorpos Neutralizantes/imunologia , Criança , Ensaios Clínicos como Assunto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA