Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
1.
Ann Vasc Surg ; 2024 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-39426669

RESUMO

INTRODUCTION: Significant practice variability exists regarding the management of intermittent claudication (IC) across anatomic segments. We sought to answer the question of whether the safety, efficacy, and durability outcomes of an endovascular approach with or without common femoral endarterectomy for complex aortoiliac occlusive disease (AIOD) justify a surgical approach in patients presenting with IC. METHODS: A retrospective single-center review of all patients who were treated using an endovascular approach for AIOD with or without CFE from 2010 to 2020 was conducted. The review was limited to those with symptoms of IC. Patient- and limb-level preoperative presentations were reviewed. The outcomes were postoperative complications and patency rates in addition to freedom from re-intervention. Subgroup analyses were conducted to compare patients who underwent endovascular and hybrid procedures. RESULTS: A total of 245 limbs in 180 consecutive patients were analyzed. The mean age was 65 years and 61% were males. Of 176 patients, 101 (57%) had TASC class D and 18 (10%) had Class C. Eleven limbs (7.4%) had access site complications, 12 (7.9%) had surgical wound complications, and below-the-knee amputation was observed in 2 limbs (0.82%) (2 patients). Two (1.0%) patients had perioperative MI, 1(0.5%) stroke, 1(0.5%) AKI that progressed to dialysis, and no 30-day mortality. Rutherford's classification was improved during the follow-up period. The 1-, 2- and 5-year primary patency rates were 94%, 77%, and 58%; primary-assisted patency rates were 98%,91%, and 79%, respectively; and secondary patency rates were 100% for all follow-up periods. Patients who had concurrent CFE were likely to have hypertension, hyperlipidemia, and anatomically more diffuse disease. No significant differences in patency or reintervention-free survival were observed, though event rates were low in both outcomes and trended toward a protective effect with CFE. CONCLUSION: Endovascular management for complex AIOD with or without CFE for IC patients is safe, effective, and durable. These results justify an active, patient-centered approach for this advanced anatomic disease pattern. The morbidity of a hybrid approach in the CFE subset is low and treatment vessel patency is excellent. The presence of anatomically advanced AIOD is not prohibitive for the treatment of patients with IC, however careful patient selection is essential.

2.
Ann Vasc Surg ; 2024 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-39369886

RESUMO

OBJECTIVES: Tandem lesions of the proximal aortic branch vessels and carotid bifurcation are uncommon. While management strategies vary, a hybrid approach of carotid endarterectomy (CEA) with retrograde common carotid artery (CCA) or innominate artery (IA) stenting has become a mainstay of treatment. The purpose of this paper was to provide a review of the literature, discuss alternative treatment modalities, and highlight technical considerations of the hybrid approach. METHODS: We performed a systematic review of the literature by searching relevant key words in the the Cochrane Library, PubMed/Medline, and Embase. The primary endpoints of this study were stroke and all-cause mortality at 30 days. Secondary outcomes included rate of technical success, re-stenosis and need for re-intervention, and stroke and all-cause mortality at 1 year. RESULTS: We identified 15 retrospective cohort studies with a cumulative 242 patients who underwent hybrid repair. The average technical success rate of hybrid repair for the management of tandem carotid lesions was high (98.8%). Multiple studies reported zero events. The average 30-day mortality rate across all studies was 0.6% (pooled: 3/242, 1.2%) and average 30-day stroke rate across all studies was 0.9% (pooled: 7/242, 2.9%). Of the studies that reported rates of re-stenosis and need for re-intervention, the average re-stenosis rate was 9.6% (pooled 34/209; 16.3%). The most common area of re-stenosis was the proximal carotid CCA/IA (61.7%). The average re-intervention rate across all studies was 4.5% (pooled 13/209; 6.2%). CONCLUSIONS: A hybrid approach of CEA with retrograde CCA/IA stenting is a safe and effective treatment modality for tandem carotid disease. However, there remains a paucity of high-level data as single-center studies are subject to publication bias. This study highlights the critical need for a prospective registry to prognosticate the risk of stroke and mortality for patients with asymptomatic vs. symptomatic tandem carotid lesions.

3.
Semin Vasc Surg ; 37(2): 111-117, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39151991

RESUMO

Vascular surgeons have the ability to manage and intervene on numerous vascular diseases of both the arterial and venous systems. With the growing number of interventions available as endovascular technology evolves, it is important to determine when a procedure is safely indicated for a vascular surgery patient. Appropriate Use Criteria (AUC) offer synthesized clinical information and practice standards that can aid clinicians in making these management decisions. Professional societies, such as the Society for Vascular Surgery, bring experts in the field together to collaborate and create AUC for various vascular diseases and interventions. It is essential to publish these criteria in peer-reviewed journals, as well as make them available on public websites so the information is available to vascular surgeons and interventionalists from other specialties who also treat patients with vascular disease. Cardiology, interventional radiology, and interventional nephrology are some other specialties that perform procedures for vascular disease, and vascular interventions by nonsurgeon specialists continue to increase. The Society for Vascular Surgery has published AUC on intermittent claudication, carotid disease, and abdominal aneurysm management. These are intended to guide practice, but also have highlighted areas for improvement that would allow for more universal implementation of AUC in vascular patient care across medical specialties. Increased intersocietal participation and perhaps inclusion of government and other payer participation will allow professional society-sponsored AUC to evolve, resulting in coordinated, appropriate care for vascular surgery patients.


Assuntos
Sociedades Médicas , Doenças Vasculares , Procedimentos Cirúrgicos Vasculares , Humanos , Procedimentos Cirúrgicos Vasculares/normas , Sociedades Médicas/normas , Doenças Vasculares/terapia , Doenças Vasculares/cirurgia , Doenças Vasculares/diagnóstico , Consenso , Guias de Prática Clínica como Assunto/normas , Fidelidade a Diretrizes/normas , Cirurgiões/normas , Comitês Consultivos/normas , Procedimentos Endovasculares/normas , Procedimentos Endovasculares/efeitos adversos , Tomada de Decisão Clínica , Seleção de Pacientes , Resultado do Tratamento
4.
Ann Vasc Surg ; 2024 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-39009118

RESUMO

BACKGROUND: Advancements in the management of venous disease have been documented in scientific literature. We performed a bibliometric analysis using citations as an indication of impact to analyze the most influential articles on venous disease and treatment. METHODS: A retrospective search of the Web of Science database was conducted in May 2023. Key search terms were queried to generate relevant articles. Articles were ranked on total number of citations and average number of citations per year. Metrics analyzed included top journals, impact factor, journal discipline, institution and country of publication, author degree and gender, number of publications per year, level of evidence, and article topic area. RESULTS: The top 100 articles on venous disease were published between 1994 and 2020, with a total of 102,856 citations, average 1,028 citations/article, and mean of 70 citations/year. The most popular article was "Incidence of thrombotic complications of in critically ill Intensive Care Unit patients with COVID-19" with 3,482 citations in total. The most popular journals were New England Journal of Medicine (22 articles), Lancet (14 articles), and CHEST (13 articles), pertaining to management of deep venous thrombosis (DVT). The Journal of Vascular surgery had 2 influential articles, focused on management of chronic venous disease. Many articles were published in the United States (52), Canada (38), and Netherlands (25). Prolific authors were predominantly male (96%) and 59% were MDs versus 29% combined MD/PhD and 12% PhDs. Popular venous articles included guidelines/standards for DVT management (12%), epidemiology of venous thromboembolism (12%), and anticoagulation for DVT (12%). Specific venous thromboembolism risk factors within popular literature included prothrombotic genes, malignancy, pregnancy, trauma, and COVID-19. Articles on surgical interventions included inferior vena cava filter placement, catheter-directed thrombolysis, and risks of femoral and subclavian vein catheterization. Venous stenting and mechanical thrombectomy were not within the top articles. CONCLUSIONS: Top-cited articles on venous disease emphasized management of DVT, followed by chronic venous disease, through the collaboration of multiple medical and surgical specialties. The largest number of citations in recent DVT literature was driven by COVID-19 complications.

5.
Ann Vasc Surg ; 96: 166-175, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37169247

RESUMO

BACKGROUND: Cardiovascular complications are a major cause of morbidity and mortality in the postoperative period after major vascular surgery. Depending on the study population, up to 25% of patients have troponin elevation after noncardiac surgery, yet many do not meet the diagnosis of myocardial infarction (MI). Although outcomes of routine troponin elevation in patients undergoing mixed major vascular surgery have been evaluated, this has not been studied exclusively in elective, open abdominal aortic aneurysm repair (oAAA), especially regarding perioperative and overall mortality. METHODS: We conducted a single-center, retrospective review of routine troponin surveillance for consecutive, oAAA from 2014 to 2019. A total of 319 patients were identified and analyzed for management patterns and interventions. The cohort was stratified into groups for comparison based on those in whom troponin was routinely checked (RC) as part of a care strategy during the study period, not routinely checked (NRC), elevated troponin (ET) >0.001 ng/mL, and not elevated. The median follow-up was 21.5 ± 23.8 months. Groups were compared on demographic data, cardiac comorbidities, 30-day and 3-year outcomes for MI and death using two-sample t-tests, Wilcoxon rank sum tests, Pearson chi-square tests, and Fisher exact tests when appropriate. RESULTS: Troponin was measured in 83.7% (267/319) of patients who underwent elective oAAA repair. Routine troponin checks were obtained in 79.9% (255/319) of patients. ET was identified in 16.5% of those with RC (42/255) and 4.7% of those with NRC (3/64). Of patients with ET, 37.8% (17/45) had a cardiology consultation, 4.4% (2/45) had a percutaneous coronary intervention (PCI), and 4.4% (2/45) had another cardiac intervention. All 4 patients undergoing PCI or other cardiac intervention had received routine troponin checks. Patients with ET were older (71.2 vs. 68.6; P = 0.04), more likely to receive intraoperative blood products (P = 0.003), had longer operative times (P = 0.011), higher length of stay (9 vs. 7 days; P < 0.01), and higher 30-day MI rate (3 vs. 0; P = 0.04). They had neither longer aortic clamp times nor worse preoperative cardiac function, and the proximal clamp position during oAAA repair did not impact troponin detection. Additionally, 3-year overall mortality was increased in patients who had ET but there was not a significant difference in 3-year mortality between groups receiving routine troponin checks versus not. CONCLUSIONS: ET, identified after elective oAAA repair, was associated with a higher risk of 30-day MI and lower overall survival. However, it was not demonstrated that routine assessment of troponin levels postoperatively leads to decreased 3-year mortality in this setting.


Assuntos
Aneurisma da Aorta Abdominal , Infarto do Miocárdio , Intervenção Coronária Percutânea , Procedimentos de Cirurgia Plástica , Humanos , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/etiologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia
6.
J Vasc Surg ; 77(3): 778-784, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-37221895

RESUMO

OBJECTIVE: The Society for Vascular Surgery published abdominal aortic aneurysm (AAA) practice guidelines in 2003, 2009, and 2018 to improve the management and treatment of AAAs. In 2014, our vascular surgery department implemented a quarterly AAA dashboard (AAAdb) to record the perioperative outcomes and guideline compliance with a focus on intervention appropriateness and procedural follow-up, which supplemented our Vascular Quality Initiative data. From the available reported evidence and expert consensus opinions, nine additional criteria for the appropriate treatment of AAAs <5 cm in women and <5.5 cm in men were noted, when applicable. The purpose of our study was to assess the effects of AAAdb implementation on adherence to society and institutional guidelines, documentation of treatment rationale, and the quality of follow-up. METHODS: We performed a retrospective review of elective open and endovascular AAA repair at a single institution from 2010 to 2018. The AAAdb was implemented in the middle of this period in 2014. The patient demographics, aortic size, repair indication, repair type, 30-day mortality, and postoperative and 1-year follow-up imaging findings were analyzed. The primary outcome was adherence to intervention appropriateness and the follow-up guidelines. The categorical factors were summarized using frequencies and percentages and compared using the Pearson χ2 test or Fisher exact test. Continuous measures were summarized using the mean ± standard deviation and compared between study periods using two-sample t tests. RESULTS: From 2010 to 2018, 1549 patients had undergone elective AAA repair: 657 before and 892 after AAAdb implementation. No differences were found in AAA size after AAAdb (5.6 ± 1.2 cm vs 5.6 ± 1.1 cm; P = .88). However, the proportion of size-appropriate repairs increased (64.1% vs 71.3%; P = .003). The proportion of small AAA repairs with a documented rationale had increased (64.4% vs 80.5%; P < .001), with rapid disease progression cited most often. No difference was found in 30-day mortality (1.2% vs 1.5%; P = .69). Follow-up imaging after endovascular abdominal aortic aneurysm repair increased at <60 days postoperatively (76% vs 84%; P = .004) and at 1 year of follow-up (78% vs 86%; P = .0005). The proportion of patients with endoleak at <60 days postoperatively had increased in the post-AAAdb cohort (21% vs 29%; P = .012). CONCLUSIONS: The AAAdb served as a centerpiece for improving the appropriateness of care and compliance with national and institutional guidelines, including treatment of small AAAs in special circumstances. Its implementation was associated with higher quality follow-up and surveillance in a high-volume, regional aortic center. Consideration should be given to adding additional criteria to the Society for Vascular Surgery guidelines and Vascular Quality Initiative reporting.


Assuntos
Aneurisma da Aorta Abdominal , Masculino , Humanos , Feminino , Aorta , Consenso , Confiabilidade dos Dados
7.
Vascular ; : 17085381221141737, 2023 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-36802992

RESUMO

OBJECTIVE: Hypogastric coverage may be required for occlusive disease at the iliac arterial bifurcation. In this study, we sought to determine patency rates of common-external iliac artery (C-EIA) bare metal stents (BMS) spanning the hypogastric origin in patients with aortoiliac occlusive disease (AIOD). In addition, we sought to identify predictors of C-EIA BMS patency loss and major adverse limb events (MALE) in patients requiring hypogastric coverage. We hypothesized that worsening stenosis of the hypogastric origin would negatively influence C-EIA stent patency and freedom from MALE. METHODS: This is a single center, retrospective review of consecutive patients undergoing elective, endovascular treatment of aortoiliac disease (AIOD) between 2010 and 2018. Only patients with C-EIA BMS coverage of a patent IIA origin were included in the study. Hypogastric luminal diameter was determined from preoperative CT angiography. Analysis was performed using Kaplan-Meier survival analysis, univariable and multivariable logistic regression, and receiver operator characteristics (ROC). RESULTS: There were 236 patients (318 limbs) who were included in the study. AIOD was TASC C/D in 236/318 (74.2%) of cases. C-EIA stent primary patency was 86.5% (95% confidence interval: 81.1, 91.9) at 2 years and 79.7% (72.8, 86.7) at 4 years. Freedom from ipsilateral MALE was 77.0% (71.1, 82.9) at 2 years and 68.7% (61.3, 76.2) at 4 years. Luminal diameter of the hypogastric origin was most strongly associated with loss of C-EIA BMS primary patency in multivariable analysis (hazard ratio: 0.81, p = .02). Insulin-dependent diabetes, Rutherford's class IV or above, and stenosis of the hypogastric origin were significantly predictive of MALE in both univariable and multivariable analyses. In ROC analysis, luminal diameter of the hypogastric origin was superior to chance in prediction of C-EIA primary patency loss and MALE. Hypogastric diameter >4.5 mm had a negative predictive value of 0.94 for C-EIA primary patency loss and 0.83 for MALE. CONCLUSIONS: Patency rates of C-EIA BMS are high. Hypogastric luminal diameter is an important and potentially modifiable predictor of C-EIA BMS patency and MALE in patients with AIOD.

8.
J Vasc Surg ; 77(2): 664, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36681490
9.
Ann Vasc Surg ; 93: 300-307, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36641088

RESUMO

BACKGROUND: Strategies for embolization of type 2 endoleaks include translumbar, transgraft, transarterial, and transcaval approaches. The transcaval approach is limited by an inconsistent ability to access the aortic sac and the risk of puncturing and damaging the endograft or adjacent structures. We describe a novel technique for caval to aortic aneurysm sac access and report early outcomes. METHODS: A retrospective review of all patients who underwent transcaval embolization (TCE) at a tertiary referral center. From March 2019 to June 2021, 12 patients were identified to have undergone a novel approach to transcaval aortic sac access using a 0.014″ heavy weight tip wire guide and continuous current electrocautery to create the connection between the inferior vena cava and aortic aneurysm sac. The endoleak outflow vessel is then selectively embolized with coils or liquid embolic agents. When selective embolization was not possible, the aneurysm sac was instilled with liquid embolic agents to induce thrombosis. RESULTS: Twelve patients underwent transcaval embolization using this method over the 3-year period. The average patient age was 79.2 ± 6.2 years and 10/12 (83.3%) were male. A high rate of comorbidities was noted in the cohort. Transcaval access into the aortic sac was achieved in all patients, while selective cannulation of outflow vessels was accomplished in 2/12 (16%) target vessels. Of these, both cases had vessels embolized using detachable coils and liquid embolic agents. Nonselective embolization was performed using liquid embolic and thrombotic agents in the other 10/12 cases. There was one perioperative complication of minor bleeding (1/12, 8.3%). Two patients were observed in intensive care unit for back pain. A persistent endoleak was identified on postoperative imaging performed at 30 days in 4/12 (33.3%) patients. Sac enlargement > 5 mm following TCE was observed in 3/12 (25%) patients. Three patients underwent open conversion with endovascular aneurysm repair explant. One patient was explanted at 1 month after failure to embolize the endoleak flow channel using TCE. A second was explanted for persistent endoleak found to be a Type IIIb with aortic diameter growth > 5 mm at 15-month follow-up. The third explant was performed for aortic sac infection at 4 months postprocedure without endoleak. CONCLUSIONS: TCE is an adjunctive technique to treat endoleaks in patients who have either failed transarterial or translumbar access. An electrified 0.014″ chronic total occlusion wire technique for transcaval access to the aortic sac for endoleak embolization can be successful in all cases without significant acute morbidity or mortality. The transcaval approach is still limited by ability to steer catheters and microcatheters into the outflow vessels with a resultant persistent endoleak and eventual need for explant.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma Aórtico , Implante de Prótese Vascular , Embolização Terapêutica , Procedimentos Endovasculares , Humanos , Masculino , Idoso , Idoso de 80 Anos ou mais , Feminino , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/terapia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Implante de Prótese Vascular/efeitos adversos , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Aneurisma Aórtico/cirurgia , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/métodos , Estudos Retrospectivos
10.
Artigo em Inglês | MEDLINE | ID: mdl-36243238

RESUMO

To characterize patient risk profiles and outcomes associated with staged ultra-hybrid repair of extensive aortic disease, in which open thoracoabdominal completion was performed after thoracic stent grafting. From 1/2006 to 1/2021, 92 patients underwent open thoracoabdominal repair of chronic dissection (n=58, 63%), degenerative aneurysm (n=28, 30%), endoleak (n=4, 4.3%), or symptomatic acute type B dissection (n=2, 2.2%) after descending thoracic stent grafting (69, 75%), frozen elephant trunk (5, 5%), or both (18, 20%). The surgical graft was sewn to the distal endovascular device in situ, reducing the extent of the open procedure and eliminating the need for hypothermic circulatory arrest. Mean age was 58±13 years, 89 (97%) were hypertensive, 38 (43%) had chronic obstructive pulmonary disease, 63 (72%) were smokers, 20 (24%) had a prior stroke, and 33 (36%) had a suspected or confirmed heritable aortic condition. Hospital mortality was 7.6% (n=7). Complications included dialysis (16, 20%), tracheostomy (8, 8.7%), stroke (5, 5.7%), and permanent paralysis (6, 6.9%). Survival at 1, 3, and 5 years was 80%, 71%, and 66%, respectively. Mortality was associated with higher blood urea nitrogen and longer distance between the distal endograft edge and proximal patent visceral vessel (P=0.004 and .01, respectively). Patients with extensive aortic disease undergoing open aortic repair after thoracic stent grafting are often young with chronic dissection, multiple comorbidities, or a heritable aortic condition. Success of staged ultra-hybrid operations demonstrates open and endovascular repair strategies are complementary, even when performed in a high-risk patient population.

11.
JTCVS Tech ; 14: 1-8, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35967241

RESUMO

Objectives: Debakey type I and IIIb aortic dissections are complicated by extension along the full length of the aorta. Over the long term, the thoracoabdominal aorta in these patients often continues to degenerate, requiring endovascular or open repair. The purpose of this investigation is to determine the early clinical outcome on aortic remodeling using a composite thoracic stent graft and thoracoabdominal bare metal extension stenting strategy. Methods: From April 2019 to April 2021, 73 patients with Debakey I/IIIb aortic dissection underwent endovascular stent graft repair of the descending thoracic aorta and repair of the thoracoabdominal aorta using bare metal extension stenting. Preoperative and follow-up surveillance computed tomography imaging scans were analyzed. Results: Fifty-three (73%) patients had a Debakey I aortic dissection, and 50 (69%) patients underwent surgery during the chronic (time to surgery >30 days) dissection phase. Mortality at 30 days was 4% (3 hyperacute patients). Stroke occurred in 3 (4%), paraparesis in 2 (2.7%), and acute renal failure requiring dialysis occurred in 2 (2.7%) patients. On postoperative and follow-up computed tomography, there was a significant increase in false lumen thrombosis (P < .001). This coincided with a significant increase in true lumen fraction suggestive of positive aortic remodeling (P < .001) at the time of latest follow-up. Conclusions: Altering the course of aortic remodeling, with placement of a dissection stent in the thoracoabdominal aorta simultaneous with descending thoracic aortic repair may promote true lumen re-expansion and false lumen thrombosis during acute and chronic dissection phases.

12.
J Thorac Cardiovasc Surg ; 163(5): 1739-1750.e4, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35241276

RESUMO

OBJECTIVE: The study objective was to evaluate the safety and effectiveness of the second-generation, low-profile RelayPro (Terumo Aortic) thoracic endograft for the treatment of descending thoracic aortic aneurysm or penetrating atherosclerotic ulcer. METHOD: A prospective, international, nonblinded, nonrandomized, pivotal trial analyzed a primary safety end point of major adverse events at 30 days (death, myocardial infarction, stroke, renal/respiratory failure, paralysis, bowel ischemia, procedural blood loss) and a primary effectiveness end point of treatment success at 1 year (technical success, patency, absence of aneurysm rupture, type I/III endoleaks, stent fractures, reinterventions, aneurysm expansion, and migration) compared with performance goals from the previous generation Relay pivotal study. The study was conducted in 36 centers in the United States and Japan and enrolled participants between 2017 and 2019. RESULTS: The study population of 110 patients had a median (interquartile range) age of 76 (70-81) years, 69 (62.7%) were male, and 43 (39.1%) were Asian. Patients were treated for 76 fusiform aneurysms (69%), 24 saccular aneurysms (22%), and 10 penetrating atherosclerotic ulcers (9%). Most patients (82.7%) were treated with a non-bare stent configuration. Technical success was 100%. The median (interquartile range) procedure time was 91 (64-131) minutes, and the deployment time was 16 (10-25) minutes. A total of 50 patients (73.5%) in the US cohort had percutaneous access, whereas centers in Japan used only surgical cutdown. The 30-day composite major adverse events rate was 6.4% (95% upper confidence interval, 11.6%; P = .0002): 2 strokes, 2 procedural blood losses greater than 1000 mL requiring transfusion, 2 paralysis events, and 1 renal failure. Primary effectiveness was 89.2% (lower 95% confidence interval, 81.8%; P = .0185). Nine subjects experienced 11 events (1 aneurysm expansion, 6 secondary interventions, and 4 type I endoleaks). There was no loss of stent-graft patency, no rupture, no fractures, and no migration. CONCLUSIONS: The low-profile RelayPro thoracic endograft met the study primary end points and demonstrated satisfactory 30-day safety and 1-year effectiveness for the treatment of patients with aneurysms of the descending thoracic aorta or penetrating atherosclerotic ulcers. Follow-up is ongoing to evaluate longer-term outcomes and durability.


Assuntos
Aneurisma da Aorta Torácica , Aterosclerose , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/etiologia , Aneurisma da Aorta Torácica/cirurgia , Aterosclerose/etiologia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Masculino , Paralisia/etiologia , Paralisia/cirurgia , Estudos Prospectivos , Desenho de Prótese , Stents , Resultado do Tratamento , Úlcera/diagnóstico por imagem , Úlcera/cirurgia , Estados Unidos
13.
J Vasc Surg ; 76(3): 733-740.e2, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35278651

RESUMO

OBJECTIVE: The Gore Excluder iliac branch endoprosthesis (IBE; W.L. Gore & Associates, Flagstaff, AZ) is the only iliac branch device approved in the United States to preserve blood flow to the external and internal iliac arteries (IIAs). Some surgeons have used the Gore Viabahn VBX balloon expandable endoprosthesis (VBX; W.L. Gore & Associates) in the IIA rather than the self-expanding endograft designed for the IBE, the internal iliac component (IIC). The objective of the present study was to examine the outcomes for patients treated for aortoiliac artery aneurysms using the IBE with either the IIC or VBX stent. METHODS: We performed a retrospective, single-center review of patients treated for aortoiliac artery aneurysms using the Gore IBE device, with either the IIC or VBX stent into the IIA, from February 2016 to March 2021. The patient demographics, procedure details, 30-day morbidity and mortality, and 6-month and 1-year outcomes and mortality were analyzed. The categorical factors are summarized using frequencies and proportions. Continuous measures are summarized as the mean ± standard deviation. A significance level of P = .05 was assumed for all test results. The analyses were performed using SAS software, version 9.4 (SAS Institute, Cary, NC). RESULTS: A total of 62 patients (64 arteries) had undergone elective aortoiliac artery aneurysm repair with the IBE. The IIC was used exclusively in 35 cases (55%) and the VBX in 29 (45%). The patients who had received the VBX had had a higher American Society of Anesthesiologists class (P = .006). Upper extremity access was used for VBX delivery in 24.1% of the procedures. No return to the operating room was required in either group. No differences were found in technical success (IIC, 97.1%; VBX, 93.1%; P = .59), the presence of endoleak on completion (20.0% vs 6.9%; P = .17), readmission (97.1% vs 93.1%; P = .59), or mortality (1.6% vs 0%; P = .45) at 30 days. No differences were found in the requirement for any IBE reintervention after 30 days. No type Ia, Ib, or III endoleaks had occurred in either group at any follow-up point. No significant difference was found in internal iliac limb primary patency (IIC, 100%; VBX, 96.3%) between groups. A nonstatistically significant trend was found toward fewer trunk-ipsilateral leg type II endoleaks in the VBX group during follow-up. CONCLUSIONS: These data suggest that the VBX is a reasonable substitute for the IIC, with a comparable safety and efficacy profile. Given its inherent conformability, greater range of diameters, and longer working length, the VBX stent offers expanded IIA branch options with the IBE.


Assuntos
Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma Ilíaco , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/etiologia , Aneurisma Ilíaco/cirurgia , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
14.
J Vasc Surg ; 75(6): 1855-1863.e2, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35074411

RESUMO

OBJECTIVE: Racial disparities in cardiovascular risk factors and disease outcomes have been well documented. A knowledge gap exists regarding the role that health maintenance plays in the development and outcomes of type B aortic dissection (TBAD). In the present study, we evaluated the comparative presentation and short-term outcomes of patients with TBAD across race. METHODS: In the present single-center, retrospective study, TBAD patients who had been admitted to the intensive care unit from 2015 to 2020 were identified. Patients who had self-identified as Black (n = 57) or White (n = 123) were included. The demographics, socioeconomic status, and pre-event health maintenance were compared between the two groups. Socioeconomic disadvantage was quantified using the area deprivation index (ADI). Management strategies included nonoperative and surgical repair. The outcomes assessed included 30-day mortality, hospital length of stay, and the APACHE II (acute physiology and chronic health evaluation) score. RESULTS: The present study included 180 consecutive patients with TBAD. TBAD included complicated (n = 42) and uncomplicated (n = 138) cases, of which 79 had had high-risk features. Black patients were younger than were White patients (58.9 vs 67.6 years; P < .01) and were more likely to have end-stage renal disease (8.8% vs 0.8%; P = .01) and to present with anemia (10.5% vs 2.4%; P = .03). The TBAD anatomic features and management were similar in both groups. The rate of surgical intervention during hospitalization was 40% and 46% for the Black and White patients, respectively (P = .4). Black patients were more likely to be taking three or more hypertension agents (42.2% vs 16.4%; P = .005) and were less likely to be adherent to taking the prescribed agents (27.1% vs 6.7%; P < .001). Also, Black patients had fewer primary care physician visits before TBAD (P = .03) and more emergency department usage before TBAD (57.9% vs 26.9%; P < .001). Black patients had also had higher ADI scores (86.0 ± 14.6 vs 64.4 ± 21.3; P < .001). The median APACHE II score was the same for both Black and White patients (9 [interquartile range (IQR), 6-12] and 9 [IQR, 7-13], respectively; P = .7). The median hospital length of stay was identical for both groups (7 days; IQR, 5-13 days). The readmission rate was 24.5% for Black patients vs 15.5% for White patients (P = .16), with the 30-day mortality similar between the two groups (Black, 7.0%; White, 5.7%; P = .7). CONCLUSIONS: Black patients had presented at a younger age but with similar dissection morphology, rate of anatomic high-risk features, and APACHE II scores. The fewer primary care physician visits, greater emergency department usage, and higher ADI scores suggested lower health maintenance for the Black patients. White patients with TBAD were also highly deprived of health maintenance compared with the national percentile, indicating that TBAD is a disease that affects vulnerable populations, regardless of race.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Dissecção Aórtica/complicações , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/terapia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Humanos , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
15.
J Vasc Surg ; 76(2): 461-465, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35085749

RESUMO

OBJECTIVE: The natural history of isolated common iliac artery aneurysms (CIAAs) has not been well-studied. The optimal size threshold for elective repair of isolated CIAAs is also not well-defined. We sought to determine the natural history and growth rates of isolated CIAAs to justify a surveillance protocol and size for elective repair. METHODS: Isolated CIAAs (>2 cm) identified from January 1, 2008, through February 29, 2020, at a single center were reviewed. Patient demographics, comorbidities, and details of CIAA operative repairs were retrospectively collected. All available duplex ultrasound and computed tomography scans were reviewed from time of CIAA identification through June 2020. RESULTS: There were 244 isolated CIAAs found in 167 patients. The cohort was 94% male with an average age of 68.1 ± 8.8 years at the time of CIAA detection. CIAAs were identified with ultrasound examination 69% of the time with a mean CIAA diameter of 2.3 cm. Operative repair of a CIAA was performed in 11.4% of the cohort at an average diameter of 3.30 ± 1.02 cm. The majority of these repairs were performed via an endovascular approach (73.7%; n = 14). There were no symptomatic or ruptured isolated CIAAs. Concurrent aortic growth that led to an abdominal aortic aneurysm with diameter of at least 3 cm occurred in 10.6% (n = 26) of isolated CIAAs. The average length of time from CIAA diagnosis to repair was 65.7 ± 47.1 months. The overall CIAA growth rate was 0.4 mm/y. A subgroup analysis based on CIAA size demonstrated a growth rate of 0.2 mm/y fore CIAAs 2.00 to 2.49 cm, 0.3 mm/y for CIAAs 2.50 to 2.99cm, and 1.3 mm/y for CIAAs 3.0 cm or larger. There were two CIAAs greater than 3.0 cm with extreme growth, which significantly impacted the CIAA growth rate on sensitivity analysis. After excluding those two CIAAs from the model, the overall CIAA growth rate was 0.3 mm/y. The subgroup analysis then demonstrated a growth rate of 0.2 mm/y for CIAAs 2.00 to 2.49cm, 0.3 mm/y for CIAAs 2.50 to 2.99cm, and 0.5 mm/y for CIAAs 3 cm or larger. CONCLUSIONS: Isolated CIAAs are typically slow growing aneurysms that expectedly grow faster as they enlarge. Given the rare occurrence of rapid isolated CIAA growth, we recommend surveillance at 3 years for 2.00 to 2.49 cm isolated CIAAs, 2 years for 2.50 to 2.99 cm isolated CIAAs, and yearly for isolated CIAAs greater than 3.0 cm. The lack of symptomatic or ruptured isolated CIAAs in this study supports delaying elective repair until an isolated CIAA diameter reaches at least 3.5 cm. These recommendations should be considered for isolated CIAA practice guidelines.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma Ilíaco , Idoso , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/métodos , Feminino , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/cirurgia , Artéria Ilíaca/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Ultrassonografia Doppler Dupla
16.
Ann Vasc Surg ; 83: 195-201, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34954374

RESUMO

BACKGROUND: Small abdominal aortic aneurysms (AAA) surveillance intervals remain controversial and difficult to standardize. Current Society for Vascular Surgery guidelines lack quality evidence. The objective of this study is to examine patients followed in a high volume non-invasive vascular laboratory, determine if the current guidelines are fitting in clinical practice, and attempt to further identify risk factors for accelerated aneurysm growth. METHODS: A retrospective analysis of patients who underwent at least two ultrasounds for AAA in the vascular laboratory during 2008 -2018 with baseline diameter less than 5.0 cm was conducted. Patient demographics were collected. Groups were then created for comparison using the size criteria according to SVS guidelines. In addition, we compared overall growth rates specifically evaluating rapid growth (rate of at least 1.0 cm/year and size change of at least 0.5 cm from previous imaging), expected growth (any growth below 1.0 cm/year and of at least 0.5 cm from baseline) and no growth. RESULTS: A total of 1581 patients (1232 male and 349 female) were identified with a total of 5945 ultrasound studies. The median age was 73 years and mean follow-up was 27.8 months. Baseline AAA size was 3.0 -3.9 cm in 986 patients and 4.0 -4.9 cm in 595 patients. The average maximum growth rate was 0.18 cm/year for AAAs 3.0 -3.9 cm and 0.36 cm/year for AAAs 4.0 -4.9 cm (P <0.001). Patients with AAA 4.0 -4.9 cm at baseline were more likely to be white, male, hypertensive and have chronic kidney disease (P <0.05). 1078 patients (68.2%) demonstrated no growth over the observed time period with 342 patients (21.6%) demonstrating expected growth and 161 (10.2%) rapid growth. Male gender and baseline AAA size of 4.0 -4.9 cm were more likely to demonstrate rapid growth (P = 0.002) and eventual repair (P <0.001). Metformin use was more common in the AAA group with no growth (P <0.05). Freedom from rapid growth and repair indication at 2 years was significantly lower in those patients with baseline aneurysms 3.0 -3.9 cm (P <0.001). CONCLUSION: The overall low rate of events in small AAAs supports continued surveillance every 3 years for AAAs 3.0-3.9 cm and yearly for male patients with AAAs 4.0 -4.9 cm as recommended by the SVS Guidelines. Female gender may have less rapid growth than previously reported but likely merit more rigorous surveillance particularly as the AAAs approach 5.0 cm. Metformin use continues to demonstrate it may abrogate aneurysmal growth. Lastly, there is a subset of patients that exhibit more rapid growth of their small AAAs, and further study will be required to classify these patients.


Assuntos
Aneurisma da Aorta Abdominal , Metformina , Idoso , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/epidemiologia , Aneurisma da Aorta Abdominal/cirurgia , Feminino , Humanos , Masculino , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Ultrassonografia
17.
Ann Vasc Surg ; 82: 120-130, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34788703

RESUMO

BACKGROUND: Long-segment stenting of the infrarenal aorta and bilateral iliac arteries, with or without femoral endarterectomy for diffuse disease, has been adopted for treatment of severe aortoiliac occlusive disease (AIOD). The objective of this study was to compare outcomes of this reconstruction, termed aortoiliac stenting with bifurcation reconstruction (AISBR), to aortobifemoral bypass (ABF) in patients with comparable TASC II D lesions. METHODS: This is a single-center, retrospective review of patients treated with ABF or AISBR for comparable TASC II D lesions between 2010 and 2018. ABF patients were included only if they were deemed anatomic candidates also for AISBR after review of preoperative imaging. Patients treated for acute limb ischemia and bypass graft infection were excluded. Statistics included Fisher exact test, Kaplan-Meier analysis, and Cox proportional hazards regression. RESULTS: There were 24 ABF and 75 AISBR included in the study. The primary indication for treatment was claudication in 55 (55.6%) patients, rest pain in 28 (28.3%), and tissue loss in 16 (16.2%). Patients undergoing AISBR were more likely to be female. Femoral endarterectomies were performed in 37/75 (49.3%) AISBR and 14/24 (58.3%) ABF (P = 0.44). AISBR were performed percutaneously in 34/75 (45.1%). No AISBR required conversion to ABF. Intraoperative blood loss, procedure time and hospital length of stay (LOS) were significantly less for AISBR compared to ABF. Surgical site infections (SSI) were less common in patients undergoing AISBR (AISBR: 6/75 (8.0%) vs. ABF: 9/24 (37.5%), (P< 0.01). One AISBR and two 2 ABF developed late SSI >30 days postoperatively. The reductions in blood loss, LOS and SSI remained significant after excluding percutaneous AISBR from the analysis. Five-year primary patency was 50.8% (95% CI: 33.3, 68.4%) for AISBR and 88.1% (72.7, 100.0%) for ABF (P= 0.04). Five-year survival was 76.5% (95% CI: 63.6, 89.5) for AISBR and 100% (95% CI: 100.0, 100.0) for ABF (P = 0.07). Five-year primary assisted patency, secondary patency, freedom from reintervention and major adverse limb events did not differ significantly between groups. CONCLUSIONS: AISBR is a viable option for management of TASC II D AIOD, with lower morbidity and acceptable durability when compared to traditional ABF.


Assuntos
Arteriopatias Oclusivas , Síndrome de Leriche , Aorta Abdominal/cirurgia , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/cirurgia , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Humanos , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/cirurgia , Masculino , Estudos Retrospectivos , Fatores de Risco , Stents , Resultado do Tratamento , Grau de Desobstrução Vascular
18.
Ann Vasc Surg ; 79: 264-272, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34656714

RESUMO

BACKGROUND: There is no consensus on the method of obtaining abdominal aortic aneurysm (AAA) maximum diameters based on computed tomographic angiography, and the reproducibility and accuracy of different methods have recently been debated due to advancements in imaging. This study compared the two most common methods based on orthogonal planes and centerline of flow to determine the discordances and accuracy amongst experiences readers. METHODS: The computed tomographic angiography max diameters of 148 AAAs were measured by three experienced observers, including a vascular surgeon, a radiologist and an imaging cardiologist. Observers used two different methods with standardized protocols: multiplanar reformations based on orthogonal planes, and a software using 3D aortic reconstructions to create centerline flow lumen providing diameters based on cross sections perpendicular to this lumen. Agreements and reliability of measurement methods were assessed by intra-class correlation coefficient and Bland - Altman analysis. Discordances between measurements of the methods and the original reported measurement, as well as outside hospitals were compared. RESULTS: The average age of the cohort was 75 years and aortic diameters ranged from 3.8 to 9.6 cm. For orthogonal readings, there were agreements within 3 mm between 86% and 92% of the time, while centerline - reading agreement was between 88% and 94%, which was not statistically significant. The intra-class correlation coefficient was high between method type and between readers. Within methods, agreement was between 0.96 and 0.97, while within - reader agreement measures was between 0.96 and 0.98. In comparison to the original and the outside hospital reports, 10% ≥ of the original and 20% ≥ of the outside hospital reported measurements were discordant between the readers. CONCLUSION: Maximal AAA measurements can have substantial variability leading to clinical significance and change in patient management and outcomes. Based on the results, orthogonal and centerline measurement methods have equally high agreements and concordance within 3 mm and low variations at a high volume center. However, when compared to the official read reports, there is high discordance rates that can significantly alter patient outcomes. A standardized method of measurement maximum diameter can reduce variations and discordances among different methods.


Assuntos
Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia/normas , Angiografia por Tomografia Computadorizada/normas , Idoso , Idoso de 80 Anos ou mais , Dilatação Patológica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos
19.
J Vasc Surg ; 75(2): 495-503.e5, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34500026

RESUMO

OBJECTIVE: Limited data exists on management and outcomes of patients presenting with type A aortic dissection (TAAD) and acute lower extremity ischemia (ALI). The role of limb-related revascularization and optimal treatment strategy remains undefined. The objective of this study was to analyze dissection characteristics, treatment modalities, and outcomes of patients undergoing proximal aortic repair for TAAD with ALI. METHODS: Consecutive patients who underwent proximal aortic repair for TAAD were identified from a prospectively maintained database. Clinical data, imaging, operative details, and outcomes of patients with TAAD and ALI were retrospectively analyzed. Kaplan-Meier methodology was used to estimate overall and amputation-free survival. Log-rank tests were used to compare overall curves. Predictors of revascularization and in-hospital mortality were determined using multivariable logistic regression analysis. RESULTS: From 2010 to 2018, 463 patients with TAAD underwent proximal aortic repair. A total of 81 patients (17%) presented with ALI; 48% (39/81) with isolated ALI, and 52% (42/81) with ALI and renovisceral malperfusion. Thirty percent (24/81) required revascularization in addition to proximal aortic repair. Revascularization strategies involved endovascular (46%; 11/24), open (33%; 8/24), and hybrid (21%; 5/24) interventions. The major amputation rate was 4% (3/81), and in-hospital mortality was 21% (17/81). Amputation-free survival was significantly lower in patients requiring revascularization compared with those who did not (log-rank P = .023). Overall survival did not significantly differ between the two groups (log-rank P = .095). Overall survival was significantly lower in patients with concomitant ALI and renovisceral malperfusion compared with those with isolated ALI (log-rank P = .0017). Distal extent of dissection flap into zone 11 (odds ratio [OR], 5.65; 95% confidence interval [CI], 1.58-20.2; P = .008) and partial/complete thrombosis of any iliac artery (OR, 3.94; 95% CI, 1.23-12.6; P = .021) were associated with increased risk of requiring an additional revascularization procedure. True lumen collapse at level of renovisceral aorta (OR, 8.84; 95% CI, 1.74-44.9; P = .0086) was associated with increased risk of in-hospital mortality. CONCLUSIONS: ALI resolves after proximal aortic repair of TAAD in most cases. Distal extent of aortic dissection into zone 11 and iliac thrombosis are risk factors for additional peripheral revascularization. True lumen collapse at the renovisceral aorta and TAAD with concomitant ALI and renovisceral malperfusion portends a poor prognosis. A multi-disciplinary team approach to manage these patients who present with ascending aortic dissection and distal malperfusion may improve outcomes in this complex population.


Assuntos
Aneurisma da Aorta Torácica/complicações , Dissecção Aórtica/complicações , Procedimentos Endovasculares/métodos , Isquemia/etiologia , Extremidade Inferior/irrigação sanguínea , Doença Aguda , Dissecção Aórtica/diagnóstico , Dissecção Aórtica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/cirurgia , Feminino , Seguimentos , Mortalidade Hospitalar/tendências , Humanos , Incidência , Isquemia/epidemiologia , Isquemia/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Resultado do Tratamento , Estados Unidos/epidemiologia
20.
Semin Thorac Cardiovasc Surg ; 34(3): 793-801, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34271093

RESUMO

To assess and compare patient-reported long-term health-related quality of life (HRQoL) after combined proximal aortic (arch ± ascending, root) and distal aortic (descending thoracic ± abdominal) replacement using open vs multimodal/endovascular (hybrid) approaches. From 2010 to 2016, 146 adults underwent single- or multi-stage aortic arch plus descending thoracic aorta replacement, 31 open and 115 hybrid. The 2 surgical approach groups had similar preoperative characteristics and extent of surgery. Cross-sectional follow-up revealed 49 deaths (7 open, 42 hybrid). Of the 97 survivors, 72 (74%) responded to the Patient-Reported Outcomes Measurement Information System (PROMIS) Global-10 survey (18 open, 54 hybrid) a median 6.2 years (15th, 85th percentiles: 3.1, 7.9) after their last aortic surgery. Predictors of HRQoL scores were identified by random forest regression. Overall physical HRQoL T-score was lower than that of population norms (46 vs 50, P < 0.0001); mental HRQoL T-score was similar (50 vs 50, P > 0.9). Neither T-score was significantly different according to surgical approach (P ≥ 0.3). Greater number of postoperative complications and history of chronic obstructive pulmonary disease were the most important predictors of lower physical HRQoL, and prior myocardial infarction was the most important predictor of lower mental HRQoL. Although extensive aortic replacement had a small long-term effect on patient-reported physical HRQoL, both physical and mental HRQoL can be preserved in survivors with both surgical approaches. Surgeons should recommend the approach they believe will yield the best long-term survival, but lifelong follow-up is crucial, and patients should understand that they may require multiple operations.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Adulto , Dissecção Aórtica/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Estudos Transversais , Procedimentos Endovasculares/efeitos adversos , Humanos , Qualidade de Vida , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA