Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 93
Filtrar
1.
Handb Clin Neurol ; 201: 19-42, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38697740

RESUMO

Electrodiagnostic testing (EDX) has been the diagnostic tool of choice in peripheral nerve disease for many years, but in recent years, peripheral nerve imaging has been used ever more frequently in daily clinical practice. Nerve ultrasound and magnetic resonance (MR) neurography are able to visualize nerve structures reliably. These techniques can aid in localizing nerve pathology and can reveal significant anatomical abnormalities underlying nerve pathology that may have been otherwise undetected by EDX. As such, nerve ultrasound and MR neurography can significantly improve diagnostic accuracy and can have a significant effect on treatment strategy. In this chapter, the basic principles and recent developments of these techniques will be discussed, as well as their potential application in several types of peripheral nerve disease, such as carpal tunnel syndrome (CTS), ulnar neuropathy at the elbow (UNE), radial neuropathy, brachial and lumbosacral plexopathy, neuralgic amyotrophy (NA), fibular, tibial, sciatic, femoral neuropathy, meralgia paresthetica, peripheral nerve trauma, tumors, and inflammatory neuropathies.


Assuntos
Doenças do Sistema Nervoso Periférico , Humanos , Doenças do Sistema Nervoso Periférico/diagnóstico , Doenças do Sistema Nervoso Periférico/diagnóstico por imagem , Ultrassonografia/métodos , Imageamento por Ressonância Magnética/métodos , Eletrodiagnóstico/métodos
2.
Korean J Radiol ; 25(5): 449-458, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38685735

RESUMO

Selective fascicular involvement of the median nerve trunk above the elbow leading to anterior interosseous nerve (AIN) syndrome is a rare form of peripheral neuropathy. This condition has recently garnered increased attention within the medical community owing to advancements in imaging techniques and a growing number of reported cases. In this article, we explore the topographical anatomy of the median nerve trunk and the clinical features associated with AIN palsy. Our focus extends to unique manifestations captured through MRI and ultrasonography (US) studies, highlighting noteworthy findings, such as nerve fascicle swelling, incomplete constrictions, hourglass-like constrictions, and torsions, particularly in the posterior/posteromedial region of the median nerve. Surgical observations have further enhanced the understanding of this complex neuropathic condition. High-resolution MRI not only reveals denervation changes in the AIN and median nerve territories but also illuminates these alterations without the presence of compressing structures. The pivotal roles of high-resolution MRI and US in diagnosing this condition and guiding the formulation of an optimal treatment strategy are emphasized.


Assuntos
Imageamento por Ressonância Magnética , Nervo Mediano , Ultrassonografia , Humanos , Imageamento por Ressonância Magnética/métodos , Nervo Mediano/diagnóstico por imagem , Ultrassonografia/métodos , Braço/inervação , Braço/diagnóstico por imagem , Neuropatia Mediana/diagnóstico por imagem , Síndrome
3.
Skeletal Radiol ; 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38581584

RESUMO

OBJECTIVE: This study examines the correlation between MRI findings and difficult dissection during proximal primary hamstring repair and postoperative sciatica. MATERIALS AND METHODS: A total of 32 cases of surgically repaired hamstring tendon tears that underwent preoperative and postoperative MRI were divided into sciatica (n = 12) and control (n = 20) groups based on the presence or absence of postoperative sciatica. Cases were scored by two blinded musculoskeletal radiologists for imaging features associated with difficult surgical dissection and the development of subsequent sciatica. Intra- and interrater agreements, as well as correlation of MRI findings with symptoms (odds ratio, OR), were calculated. RESULTS: On preoperative MRI, diffuse hamstring muscle edema pattern suggestive of active denervation (OR 9.4-13.6), and greater sciatic perineural scar circumference (OR 1.9-2) and length (OR 1.2-1.3) were significantly correlated with both difficult dissection and postoperative sciatica. Preoperatively, a greater number of tendons torn (OR 3.3), greater tear cross-sectional area (CSA, OR 1.03), and increased nerve T2-weighted signal (OR 3.2) and greater perineural scar thickness (OR 1.7) were also associated with difficult dissection, but not postoperative sciatica. On postoperative MRI, hamstring denervation, sciatic nerve tethering to the hamstring tendon, and development of perineural scar and greater perineural scar extent were all significantly correlated with postoperative sciatica. CONCLUSION: Preoperative hamstring MRI demonstrates findings predictive of difficult sciatic nerve dissection; careful MRI evaluation of the nerve and for the presence and extent of perineural scar is important for preoperative planning. Preoperative and postoperative MRI both depict findings that correlate with postoperative sciatica.

4.
Eur Spine J ; 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38472429

RESUMO

PURPOSE: To test equivalency of deep-learning 3D lumbar spine MRI with "CT-like" contrast to CT for virtual pedicle screw planning and geometric measurements in robotic-navigated spinal surgery. METHODS: Between December 2021 and June 2022, 16 patients referred for spinal fusion and decompression surgery with pre-operative CT and 3D MRI were retrospectively assessed. Pedicle screws were virtually placed on lumbar (L1-L5) and sacral (S1) vertebrae by three spine surgeons, and metrics (lateral deviation, axial/sagittal angles) were collected. Vertebral body length/width (VL/VW) and pedicle height/width (PH/PW) were measured at L1-L5 by three radiologists. Analysis included equivalency testing using the 95% confidence interval (CI), a margin of ± 1 mm (± 2.08° for angles), and intra-class correlation coefficients (ICCs). RESULTS: Across all vertebral levels, both combined and separately, equivalency between CT and MRI was proven for all pedicle screw metrics and geometric measurements, except for VL at L1 (mean difference: - 0.64 mm; [95%CI - 1.05, - 0.24]), L2 (- 0.65 mm; [95%CI - 1.11, - 0.20]), and L4 (- 0.78 mm; [95%CI - 1.11, - 0.46]). Inter- and intra-rater ICC for screw metrics across all vertebral levels combined ranged from 0.68 to 0.91 and 0.89-0.98 for CT, and from 0.62 to 0.92 and 0.81-0.97 for MRI, respectively. Inter- and intra-rater ICC for geometric measurements ranged from 0.60 to 0.95 and 0.84-0.97 for CT, and 0.61-0.95 and 0.93-0.98 for MRI, respectively. CONCLUSION: Deep-learning 3D MRI facilitates equivalent virtual pedicle screw placements and geometric assessments for most lumbar vertebrae, with the exception of vertebral body length at L1, L2, and L4, compared to CT for pre-operative planning in patients considered for robotic-navigated spine surgery.

5.
Clin Imaging ; 108: 110112, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38457906

RESUMO

PURPOSE: To illustrate MRI findings in patients with femoral neuropathy following anterior approach total hip arthroplasty (THA). METHODS: This was a retrospective review of patients who underwent MRI for femoral neuropathy following anterior approach THA between January 1, 2010, and July 1, 2022. Included patients had no preexisting neurologic condition. Clinical and diagnostic data were collected. MRIs were reviewed in consensus by 2 musculoskeletal radiologists. RESULTS: A total of 115 patient records were reviewed, 17 of which were included in the final analysis (mean age 64 years; 11 females). Study subjects presented with weakness with hip flexion and knee extension and pain and numbness in the femoral nerve distribution. In 7 subjects, the femoral nerve appeared normal. In 5 subjects, the femoral nerve was hyperintense on fluid-sensitive fat-suppressed imaging. In 4 patients, mass effect on the femoral nerve by either ill-defined soft tissue edema (n = 2), seroma (n = 1), or heterotopic ossification (n = 1) was detected. Only 1 patient had a nerve transection. Patients were imaged at a median time of 8 months (range: 1 day to 11 years) following arthroplasty placement. Clinical follow-up was available in 8 patients, of whom half had complete symptomatic resolution and half had partial improvement at a mean follow-up time of 39.3 months (SD 51.1). Of these 8, 1 underwent revision arthroplasty, 1 had removal of hardware, and another had excision of heterotopic ossification. CONCLUSION: MRI provides a means to directly evaluate the femoral nerve following anterior approach THA in both the immediate and chronic postoperative periods.


Assuntos
Artroplastia de Quadril , Neuropatia Femoral , Ossificação Heterotópica , Feminino , Humanos , Pessoa de Meia-Idade , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Neuropatia Femoral/diagnóstico por imagem , Neuropatia Femoral/etiologia , Nervo Femoral/diagnóstico por imagem , Nervo Femoral/lesões , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Imageamento por Ressonância Magnética , Estudos Retrospectivos , Resultado do Tratamento
6.
Front Neurol ; 15: 1359033, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38426170

RESUMO

Introduction: T2 mapping can characterize peripheral neuropathy and muscle denervation due to axonal damage. Three-dimensional double echo steady-state (DESS) can simultaneously provide 3D qualitative information and T2 maps with equivalent spatial resolution. However, insufficient signal-to-noise ratio may bias DESS-T2 values. Deep learning reconstruction (DLR) techniques can reduce noise, and hence may improve quantitation of high-resolution DESS-T2. This study aims to (i) evaluate the effect of DLR methods on DESS-T2 values, and (ii) to evaluate the feasibility of using DESS-T2 maps to differentiate abnormal from normal nerves and muscles in the upper extremities, with abnormality as determined by electromyography. Methods and results: Analysis of images from 25 subjects found that DLR decreased DESS-T2 values in abnormal muscles (DLR = 37.71 ± 9.11 msec, standard reconstruction = 38.56 ± 9.44 msec, p = 0.005) and normal muscles (DLR: 27.18 ± 6.34 msec, standard reconstruction: 27.58 ± 6.34 msec, p < 0.001) consistent with a noise reduction bias. Mean DESS-T2, both with and without DLR, was higher in abnormal nerves (abnormal = 75.99 ± 38.21 msec, normal = 35.10 ± 9.78 msec, p < 0.001) and muscles (abnormal = 37.71 ± 9.11 msec, normal = 27.18 ± 6.34 msec, p < 0.001). A higher DESS-T2 in muscle was associated with electromyography motor unit recruitment (p < 0.001). Discussion: These results suggest that quantitative DESS-T2 is improved by DLR and can differentiate the nerves and muscles involved in peripheral neuropathies from those uninvolved.

7.
Global Spine J ; : 21925682241232328, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38324511

RESUMO

STUDY DESIGN: Human Cadaveric Study. OBJECTIVE: This study aims to explore the feasibility of using preoperative magnetic resonance imaging (MRI), zero-time-echo (ZTE) and spoiled gradient echo (SPGR), as source data for robotic-assisted spine surgery and assess the accuracy of pedicle screws. METHODS: Zero-time-echo and SPGR MRI scans were conducted on a human cadaver. These images were manually post-processed, producing a computed tomography (CT)-like contrast. The Mazor X robot was used for lumbar pedicle screw-place navigating of MRI. The cadaver underwent a postoperative CT scan to determine the actual position of the navigated screws. RESULTS: Ten lumbar pedicle screws were robotically navigated of MRI (4 ZTE; 6 SPGR). All MR-navigated screws were graded A on the Gertzbein-Robbins scale. Comparing preoperative robotic planning to postoperative CT scan trajectories: The screws showed a median deviation of overall 0.25 mm (0.0; 1.3), in the axial plane 0.27 mm (0.0; 1.3), and in the sagittal plane 0.24 mm (0.0; 0.7). CONCLUSION: This study demonstrates the first successful registration of MRI sequences, ZTE and SPGR, in robotic spine surgery here used for intraoperative navigation of lumbar pedicle screws achieving sufficient accuracy, showcasing potential progress toward radiation-free spine surgery.

8.
Skeletal Radiol ; 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38386108

RESUMO

OBJECTIVE: To evaluate the impact of deep learning (DL) reconstruction in enhancing image quality and nerve conspicuity in LSP MRN using DESS sequences. Additionally, a geometric image combination (GIC) method to improve DESS signals' combination was proposed. MATERIALS AND METHODS: Adult patients undergoing 3.0 Tesla LSP MRN with DESS were prospectively enrolled. The 3D DESS echoes were separately reconstructed with and without DL and DL-GIC combined reconstructions. In a subset of patients, 3D T2-weighted short tau inversion recovery (STIR-T2w) sequences were also acquired. Three radiologists rated 4 image stacks ('DESS S2', 'DESS S2 DL', 'DESS GIC DL' and 'STIR-T2w DL') for bulk motion, vascular suppression, nerve fascicular architecture, and overall nerve conspicuity. Relative SNR, nerve-to-muscle, -fat, and -vessel contrast ratios were measured. Statistical analysis included ANOVA and Wilcoxon signed-rank tests. p < 0.05 was considered statistically significant. RESULTS: Forty patients (22 females; mean age = 48.6 ± 18.5 years) were enrolled. Quantitatively, 'DESS GIC DL' demonstrated superior relative SNR (p < 0.001), while 'DESS S2 DL' exhibited superior nerve-to-background contrast ratio (p value range: 0.002 to < 0.001). Qualitatively, DESS provided superior vascular suppression and depiction of sciatic nerve fascicular architecture but more bulk motion as compared to 'STIR-T2w DL'. 'DESS GIC DL' demonstrated better nerve visualization for several smaller, distal nerve segments than 'DESS S2 DL' and 'STIR-T2w DL'. CONCLUSION: Application of a DL reconstruction with geometric image combination in DESS MRN improves nerve conspicuity of the LSP, especially for its smaller branch nerves.

10.
Skeletal Radiol ; 53(6): 1173-1181, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38165469

RESUMO

OBJECTIVE: Describe features of iatrogenic "overshoot" nerve injuries on ultrasound and MRI, which occur when an instrument passes through the bone and injures the nerve after it penetrates the opposite cortex. MATERIALS AND METHODS: After a keyword search of the radiology database at a tertiary care orthopedic hospital from January 2016 to December 2022, those fulfilling the inclusion criteria of (1) instrumentation through the bone during surgery, (2) acute neuropathy immediately after surgery, (3) nerve injury confirmed on electrodiagnostics, and (4) imaging consistent with overshoot nerve injury were included. Imaging studies were retrospectively evaluated to determine primary and secondary signs of an overshoot nerve injury. RESULTS: Six patients (3 females, mean age 26.7 (range 10-49) years) had nerve injury fitting the mechanism of injury: 3 injuries to the radial nerve during fixation of distal humerus fractures, 1 tibial nerve and 1 superficial peroneal nerve injury during fixation of tibial fractures, and 1 posterior interosseous nerve injury during biceps tendon repair. Ultrasounds were performed in all while 4 also had MRI. Secondary signs included (1) cortical defect adjacent to injured nerve (n=2); (2) scar extending from bone to injured nerve (n=2); (3) screw tip pointing to injured nerve (n=1, 4) tract in bone on MRI from previous instrumentation pointing to injured nerve (n=2). CONCLUSION: In addition to primary signs such as laceration or neuroma, secondary signs of "overshoot" nerve injury include cortical defect, scar extending to nerve, screw tip pointing to nerve, and linear tract in the bone on MRI.


Assuntos
Cicatriz , Traumatismos dos Nervos Periféricos , Feminino , Humanos , Criança , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Estudos Retrospectivos , Tendões , Traumatismos dos Nervos Periféricos/diagnóstico por imagem , Traumatismos dos Nervos Periféricos/etiologia , Doença Iatrogênica
11.
Phys Med Biol ; 68(21)2023 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-37816375

RESUMO

Objective.High-resolution MRI of the cervical spine (c-spine) and extraspinal neck region requires close-fitting receiver coils to maximize the signal-to-noise ratio (SNR). Conventional, rigid C-spine receiver coils do not adequately contour to the neck to accommodate varying body shapes, resulting in suboptimal SNR. Recent innovations in flexible surface coil array designs may provide three-dimensional (3D) bendability and conformability to optimize SNR, while improving capabilities for higher acceleration factors.Approach.This work describes the design, implementation, and preliminaryin vivotesting of a novel, conformal 23-channel receive-only flexible array for cervical and extraspinal (FACE) MRI at 3-Tesla (T), with use of high-impedance elements to enhance the coil's flexibility. Coil performance was tested by assessing SNR and geometry factors (g-factors) in a phantom compared to a conventional 21-channel head-neck-unit (HNU).In vivoimaging was performed in healthy human volunteers and patients using high-resolution c-spine and neck MRI protocols at 3T, including MR neurography (MRN).Main results.Mean SNR with the FACE was 141%-161% higher at left, right, and posterior off-isocenter positions and 4% higher at the isocenter of the phantom compared to the HNU. Parallel imaging performance was comparable for an acceleration factor (R) = 2 × 2 between the two coils, but improved forR= 3 × 3 with meang-factors ranging from 1.46-2.15 with the FACE compared to 2.36-3.62 obtained with the HNU. Preliminary human volunteer and patient testing confirmed that equivalent or superior image quality could be obtained for evaluation of osseous and soft tissue structures of the cervical region with the FACE.Significance.A conformal and highly flexible cervical array with high-impedance coil elements can potentially enable higher-resolution imaging for cervical imaging.


Assuntos
Imageamento por Ressonância Magnética , Pescoço , Humanos , Imageamento por Ressonância Magnética/métodos , Pescoço/diagnóstico por imagem , Razão Sinal-Ruído , Vértebras Cervicais/diagnóstico por imagem , Imagens de Fantasmas , Desenho de Equipamento
12.
Sensors (Basel) ; 23(17)2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37688046

RESUMO

Flexible and stretchable radiofrequency coils for magnetic resonance imaging represent an emerging and rapidly growing field. The main advantage of such coil designs is their conformal nature, enabling a closer anatomical fit, patient comfort, and freedom of movement. Previously, we demonstrated a proof-of-concept single element stretchable coil design with a self-tuning smart geometry. In this work, we evaluate the feasibility of scaling this coil concept to a multi-element coil array and the associated engineering and manufacturing challenges. To this goal, we study a dual-channel coil array using full-wave simulations, bench testing, in vitro, and in vivo imaging in a 3 T scanner. We use three fabrication techniques to manufacture dual-channel receive coil arrays: (1) single-layer casting, (2) double-layer casting, and (3) direct-ink-writing. All fabricated arrays perform equally well on the bench and produce similar sensitivity maps. The direct-ink-writing method is found to be the most advantageous fabrication technique for fabrication speed, accuracy, repeatability, and total coil array thickness (0.6 mm). Bench tests show excellent frequency stability of 128 ± 0.6 MHz (0% to 30% stretch). Compared to a commercial knee coil array, the stretchable coil array is more conformal to anatomy and provides 50% improved signal-to-noise ratio in the region of interest.


Assuntos
Comércio , Engenharia , Humanos , Articulação do Joelho , Metais , Movimento
13.
Magn Reson Imaging ; 104: 29-38, 2023 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-37769881

RESUMO

OBJECTIVE: Pre-operative lumbar spine MRI is usually acquired with the patient supine, whereas lumbar spine surgery is most commonly performed prone. For MRI to be used reliably and safely for intra-operative navigation for foraminal and extraforaminal decompression, the magnitude of dorsal root ganglion (DRG) displacement between supine and prone positions needs to be understood. METHODS: A prospective study of a degenerative lumbar spine cohort of 18 subjects indicated for lumbar spine surgery. Three-dimensional T2-weighted fast spin echo and T1-weighted spoiled gradient echo sequences were acquired at 3 T. Displacement and cross-sectional area (CSA) of the bilateral DRGs at 5 motion levels (L1-2 to L5-S1) were determined via 3D segmentation by 2 independent evaluators. Wilcoxon rank-sum tests without correction for multiple comparison were performed against hypothesized 1-mm absolute displacement and corresponding 24% CSA change. RESULTS: DRG mean absolute displacement was <1 mm (p > 0.99, mean = 0.707 mm, 95% confidence interval (CI) = 0.659 to 0.755 mm), with the largest directional displacement in the dorsal-to-ventral direction from supine to prone (mean = 0.141 mm, 95% CI = 0.082 to 0.200 mm). Directional displacements caudal-to-cephalad were 0.087 mm (95% CI = 0.022 to 0.151 mm), and left-right were -0.030 mm (95%CI = -0.059 to -0.001 mm). Mean CSA change was within 24% (p > 0.99, mean = -8.30%, 95% CI = -10.5 to -6.09%). Mean absolute displacement was largest for the L1 (mean = 0.811 mm) and L2 (mean = 0.829 mm) DRGs. CONCLUSIONS: Minimal, non-statistically significant soft tissue displacement and morphological area differences were demonstrated between supine and prone positions during 3D lumbar spine MRI.

14.
J Magn Reson Imaging ; 2023 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-37702553

RESUMO

BACKGROUND: Parsonage-Turner syndrome (PTS) is characterized by severe, acute upper extremity pain and subsequent paresis and most commonly involves the long thoracic nerve (LTN). While MR neurography (MRN) can detect LTN hourglass-like constrictions (HGCs), quantitative muscle MRI (qMRI) can quantify serratus anterior muscle (SAM) neurogenic changes. PURPOSE/HYPOTHESIS: 1) To characterize qMRI findings in LTN-involved PTS. 2) To investigate associations between qMRI and clinical assessments of HGCs/electromyography (EMG). STUDY TYPE: Prospective. POPULATION: 30 PTS subjects (25 M/5 F, mean/range age = 39/15-67 years) with LTN involvement who underwent bilateral chest wall qMRI and unilateral brachial plexus MRN. FIELD STRENGTH/SEQUENCES: 3.0 Tesla/multiecho spin-echo T2-mapping, diffusion-weighted echo-planar-imaging, multiecho gradient echo. ASSESSMENT: qMRI was performed to obtain T2, muscle diameter fat fraction (FF), and cross-sectional area of the SAM. Clinical reports of MRN and EMG were obtained; from MRN, the number of HGCs; from EMG, SAM measurements of motor unit recruitment levels, fibrillations, and positive sharp waves. qMRI/MRN were performed within 90 days of EMG. EMG was performed on average 185 days from symptom onset (all ≥2 weeks from symptom onset) and 5 days preceding MRI. STATISTICAL TESTS: Paired t-tests were used to compare qMRI measures in the affected SAM versus the contralateral, unaffected side (P < 0.05 deemed statistically significant). Kendall's tau was used to determine associations between qMRI against HGCs and EMG. RESULTS: Relative to the unaffected SAM, the affected SAM had increased T2 (50.42 ± 6.62 vs. 39.09 ± 4.23 msec) and FF (8.45 ± 9.69 vs. 4.03% ± 1.97%), and decreased muscle diameter (74.26 ± 21.54 vs. 88.73 ± 17.61 µm) and cross-sectional area (9.21 ± 3.75 vs. 16.77 ± 6.40 mm2 ). There were weak to negligible associations (tau = -0.229 to <0.001, P = 0.054-1.00) between individual qMRI biomarkers and clinical assessments of HGCs and EMG. DATA CONCLUSION: qMRI changes in the SAM were observed in subjects with PTS involving the LTN. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 1.

15.
Muscle Nerve ; 2023 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-37610034

RESUMO

INTRODUCTION/AIMS: Hourglass-like constrictions (HGCs) of involved nerves in neuralgic amyotrophy (NA) (Parsonage-Turner syndrome) have been increasingly recognized with magnetic resonance neurography (MRN). This study sought to determine the sensitivity of HGCs, detected by MRN, among electromyography (EMG)-confirmed NA cases. METHODS: This study retrospectively reviewed records of patients with the clinical diagnosis of NA, and with EMG confirmation, who underwent 3-Tesla MRN within 90 days of EMG at a single tertiary referral center between 2011 and 2021. "Severe NA" positive cases were defined by a clinical diagnosis and specific EMG criteria: fibrillation potentials or positive sharp waves, along with motor unit recruitment (MUR) grades of "discrete" or "none." On MRN, one or more HGCs, defined as focally decreased nerve caliber or diffusely beaded appearance, was considered "imaging-positive." Post hoc inter-rater reliability for HGCs was measured by comparing the original MRN report against subsequent blinded interpretation by a second radiologist. RESULTS: A total of 123 NA patients with 3-Tesla MRN performed within 90 days of EMG were identified. HGCs were observed in 90.2% of all NA patients. In "severe NA" cases, based on the above EMG criteria, HGC detection resulted in a sensitivity of 91.9%. Nerve-by-nerve analysis (183 nerve-muscle pairs, nerves assessed by MRN, muscles assessed by EMG) showed a sensitivity of 91.0%. The second radiologist largely agreed with the original HGC evaluation, (94.3% by subjects, 91.8% by nerves), with no significant difference between evaluations (subjects: χ2 = 2.27, P = .132, nerves: χ2 = 0.98, P = .323). DISCUSSION: MRN detection of HGCs is common in NA.

16.
Radiology ; 308(2): e230531, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37581501

RESUMO

Over the past decades, MRI has become increasingly important for diagnosing and longitudinally monitoring musculoskeletal disorders, with ongoing hardware and software improvements aiming to optimize image quality and speed. However, surging demand for musculoskeletal MRI and increased interest to provide more personalized care will necessitate a stronger emphasis on efficiency and specificity. Ongoing hardware developments include more powerful gradients, improvements in wide-bore magnet designs to maintain field homogeneity, and high-channel phased-array coils. There is also interest in low-field-strength magnets with inherently lower magnetic footprints and operational costs to accommodate global demand in middle- and low-income countries. Previous approaches to decrease acquisition times by means of conventional acceleration techniques (eg, parallel imaging or compressed sensing) are now largely overshadowed by deep learning reconstruction algorithms. It is expected that greater emphasis will be placed on improving synthetic MRI and MR fingerprinting approaches to shorten overall acquisition times while also addressing the demand of personalized care by simultaneously capturing microstructural information to provide greater detail of disease severity. Authors also anticipate increased research emphasis on metal artifact reduction techniques, bone imaging, and MR neurography to meet clinical needs.


Assuntos
Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Humanos , Imageamento por Ressonância Magnética/métodos , Software , Algoritmos
17.
Radiology ; 308(1): e222732, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37404146

RESUMO

Postoperative MRI of the lumbar spine is a mainstay for detailed anatomic assessment and evaluation of complications related to decompression and fusion surgery. Key factors for reliable interpretation include clinical presentation of the patient, operative approach, and time elapsed since surgery. Yet, recent spinal surgery techniques with varying anatomic corridors to approach the intervertebral disc space and implanted materials have expanded the range of normal (expected) and abnormal (unexpected) postoperative changes. Modifications of lumbar spine MRI protocols in the presence of metallic implants, including strategies for metal artifact reduction, provide important diagnostic information. This focused review discusses essential principles for the acquisition and interpretation of MRI after lumbar spinal decompression and fusion surgery, highlights expected postoperative changes, and describes early and delayed postoperative complications with examples.


Assuntos
Fusão Vertebral , Estenose Espinal , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Região Lombossacral/cirurgia , Imageamento por Ressonância Magnética , Descompressão Cirúrgica/efeitos adversos , Descompressão Cirúrgica/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/cirurgia , Fusão Vertebral/efeitos adversos , Fusão Vertebral/métodos , Resultado do Tratamento
19.
Eur J Radiol ; 161: 110727, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36753810

RESUMO

PURPOSE: This study aims to characterize iatrogenic sciatic nerve injury patterns in the early, perioperative period following posterior-approach total hip arthroplasty (THA) with magnetic resonance imaging (MRI). METHODS: This was an IRB-approved retrospective analysis of patients acquired from a longitudinal, single site radiology database of patients who underwent MRI for "foot drop" within 4 weeks following posterior-approach THA surgery, over a 20-year period. RESULTS: MRI exams from 51 patients (mean age 62 years; 32 females) who met inclusion criteria were evaluated. Mean time to MRI was 2.4 days. Of 51 patients, 43 underwent primary THA, 6 revision THA and 2 explantation with antibiotic spacer placement. Ten exams revealed a normal appearance of the sciatic nerve. Nineteen showed compression of the sciatic nerve by edema or a fluid collection, without intrinsic nerve abnormality. Fifteen demonstrated perineural tethering or scar/granulation tissue encasement of the nerve, and in half of these cases the sciatic nerve was enlarged and/or hyperintense on fluid-sensitive sequences. Six patients had sciatic nerve compression secondary to quadratus femoris retraction. Six patients had complete resolution of the foot drop at a mean follow-up of 37.3 months following surgery, and in these cases the sciatic nerve appeared normal on the initial postoperative MRI. Remaining patients all had persistent weakness and paresthesias in the sciatic nerve distribution at a mean follow-up duration of 34.3 months. CONCLUSION: This retrospective case series demonstrates various sciatic nerve injury patterns in the early perioperative period on MRI and proposes a targeted MRI protocol to evaluate the sciatic nerve post THA surgery.


Assuntos
Artroplastia de Quadril , Neuropatias Fibulares , Neuropatia Ciática , Feminino , Humanos , Pessoa de Meia-Idade , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Estudos Retrospectivos , Nervo Isquiático , Neuropatia Ciática/diagnóstico por imagem , Neuropatia Ciática/etiologia , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética
20.
Skeletal Radiol ; 52(9): 1781-1784, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36752829

RESUMO

Beginning in May 2022, monkeypox infection and vaccination rates dramatically increased due to a worldwide outbreak. This case highlights magnetic resonance (MR) neurography findings in an individual who developed Parsonage-Turner syndrome (PTS) 5 days after monkeypox symptom onset and 12 days after receiving the JYNNEOS vaccination. MR neurography of the patient's left suprascapular nerve demonstrated intrinsic hourglass-like constrictions, a characteristic finding of peripheral nerves involved in PTS. Other viral infections and vaccinations are well-documented triggers of PTS, an underrecognized peripheral neuropathy that is thought to be immune-mediated and results in severe upper extremity pain and weakness. The close temporal relationship between monkeypox infection and vaccination, and PTS onset, in this case, suggests a causal relationship and marks the first known report of peripheral neuropathy associated with monkeypox.


Assuntos
Neurite do Plexo Braquial , Mpox , Doenças do Sistema Nervoso Periférico , Humanos , Neurite do Plexo Braquial/etiologia , Neurite do Plexo Braquial/complicações , Mpox/complicações , Imageamento por Ressonância Magnética/métodos , Doenças do Sistema Nervoso Periférico/diagnóstico por imagem , Doenças do Sistema Nervoso Periférico/etiologia , Vacinação/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA