Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
iScience ; 27(6): 109831, 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38784010

RESUMO

While cortical regions involved in processing binocular disparities have been studied extensively, little is known on how the human visual system adapts to changing disparity magnitudes. In this paper, we investigate causal mechanisms of coarse and fine binocular disparity processing using fMRI with a clinically validated, custom anaglyph-based stimulus. We make use of Granger causality and graph measures to reveal the existence of distinct rich and diverse clubs across different disparity magnitudes. We demonstrate that Middle Temporal area (MT) plays a specialized role with overlapping rich and diverse characteristics. Next, we show that subtle interhemispheric differences exist across various brain regions, despite an overall right hemisphere dominance. Finally, we pass the graph measures through the decision tree and found that the diverse clubs outperform rich clubs in decoding disparity magnitudes. Our study sets the stage for conducting further investigations on binocular disparity processing, particularly in the context of neuro-ophthalmic disorders with binocular impairments.

2.
IEEE Trans Biomed Eng ; 70(10): 2933-2942, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37104106

RESUMO

OBJECTIVE: We present a novel framework for the detection and continuous evaluation of 3D motion perception by deploying a virtual reality environment with built-in eye tracking. METHODS: We created a biologically-motivated virtual scene that involved a ball moving in a restricted Gaussian random walk against a background of 1/f noise. Sixteen visually healthy participants were asked to follow the moving ball while their eye movements were monitored binocularly using the eye tracker. We calculated the convergence positions of their gaze in 3D using their fronto-parallel coordinates and linear least-squares optimization. Subsequently, to quantify 3D pursuit performance, we employed a first-order linear kernel analysis known as the Eye Movement Correlogram technique to separately analyze the horizontal, vertical and depth components of the eye movements. Finally, we checked the robustness of our method by adding systematic and variable noise to the gaze directions and re-evaluating 3D pursuit performance. RESULTS: We found that the pursuit performance in the motion-through depth component was reduced significantly compared to that for fronto-parallel motion components. We found that our technique was robust in evaluating 3D motion perception, even when systematic and variable noise was added to the gaze directions. CONCLUSION: The proposed framework enables the assessment of 3D Motion perception by evaluating continuous pursuit performance through eye-tracking. SIGNIFICANCE: Our framework paves the way for a rapid, standardized and intuitive assessment of 3D motion perception in patients with various eye disorders.


Assuntos
Percepção de Movimento , Realidade Virtual , Humanos , Movimentos Oculares , Movimento (Física) , Caminhada , Acompanhamento Ocular Uniforme
3.
Surv Ophthalmol ; 68(1): 126-141, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35988744

RESUMO

We estimated the proportion of children with stereopsis following surgery in congenital and developmental cataracts by systematic review and meta-analysis and also considered the factors influencing stereopsis, such as intervention age and presence of strabismus. Stereopsis is directly related to quality of life, and investigating its levels following cataract surgery in children may help decide the right time to intervene, particularly in the context of brain plasticity. We conducted a systematic literature search using Scopus, PubMed, and Web of Science and found 25 case series, 3 cohorts, and 3 clinical trial studies from 1/1/1995 to 31/12/2020. Study-specific proportions of stereopsis from 923 children were pooled using a random-effects model, and stratified analyses were conducted based on intervention age and pre-existing strabismus as a confounder. We appraised the risk of bias using tools published by National Institutes of Health and evaluated publication bias with funnel plots and the Egger test. The pooled proportions of stereopsis based on 8 unilateral and 6 bilateral congenital cataract studies were 0.37 (95% CIs: [0.24, 0.53]) and 0.45 (95% CIs: [0.24,0.68]) when patients with preexisting strabismus were excluded as a confounder. When the intervention age was ≤6 months, proportions in unilateral congenital cataract group significantly increased to 0.52 (95% CIs: [0.37, 0.66]; P = 0.49) compared to 0.26 (95% CIs: [0.14, 0.44]; P = 0.16) otherwise. A similar increase in proportions was found when intervention age ≤4 months. In both unilateral and bilateral congenital cataract groups, proportions increased significantly when the confounder was excluded. Overall, proportions in bilateral congenital cataracts were significantly greater than unilateral cases (irrespective of confounder). Eight unilateral and 5 bilateral developmental cataract studies resulted in pooled proportions of 0.62 (95% CIs: [0.27, 0.88] and 0.82 (95% CIs: [0.4, 0.97]), respectively. Although proportions for bilateral developmental cataracts were greater than unilateral cataracts (irrespective of confounder), results were not statistically significant. Finally, proportions in unilateral developmental cataracts were significantly greater than unilateral congenital cataracts (Z = 7.413, P = 6.173694e-14). We conclude that surgical intervention within first 4-6 months can significantly affect postoperative outcomes in unilateral congenital cataracts. Analysis of existing data does not show a significant effect of intervention age on stereopsis outcomes for developmental cataracts.


Assuntos
Extração de Catarata , Catarata , Estrabismo , Criança , Humanos , Lactente , Qualidade de Vida , Acuidade Visual , Extração de Catarata/métodos , Percepção de Profundidade , Catarata/complicações , Estrabismo/cirurgia , Estudos Retrospectivos , Seguimentos
4.
Front Neurosci ; 15: 745355, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34690682

RESUMO

Standard automated perimetry (SAP) is the gold standard for evaluating the presence of visual field defects (VFDs). Nevertheless, it has requirements such as prolonged attention, stable fixation, and a need for a motor response that limit application in various patient groups. Therefore, a novel approach using eye movements (EMs) - as a complementary technique to SAP - was developed and tested in clinical settings by our group. However, the original method uses a screen-based eye-tracker which still requires participants to keep their chin and head stable. Virtual reality (VR) has shown much promise in ophthalmic diagnostics - especially in terms of freedom of head movement and precise control over experimental settings, besides being portable. In this study, we set out to see if patients can be screened for VFDs based on their EM in a VR-based framework and if they are comparable to the screen-based eyetracker. Moreover, we wanted to know if this framework can provide an effective and enjoyable user experience (UX) compared to our previous approach and the conventional SAP. Therefore, we first modified our method and implemented it on a VR head-mounted device with built-in eye tracking. Subsequently, 15 controls naïve to SAP, 15 patients with a neuro-ophthalmological disorder, and 15 glaucoma patients performed three tasks in a counterbalanced manner: (1) a visual tracking task on the VR headset while their EM was recorded, (2) the preceding tracking task but on a conventional screen-based eye tracker, and (3) SAP. We then quantified the spatio-temporal properties (STP) of the EM of each group using a cross-correlogram analysis. Finally, we evaluated the human-computer interaction (HCI) aspects of the participants in the three methods using a user-experience questionnaire. We find that: (1) the VR framework can distinguish the participants according to their oculomotor characteristics; (2) the STP of the VR framework are similar to those from the screen-based eye tracker; and (3) participants from all the groups found the VR-screening test to be the most attractive. Thus, we conclude that the EM-based approach implemented in VR can be a user-friendly and portable companion to complement existing perimetric techniques in ophthalmic clinics.

5.
Transl Vis Sci Technol ; 10(2): 1, 2021 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-34003886

RESUMO

Purpose: Assessing the presence of visual field defects (VFD) through procedures such as perimetry is an essential aspect of the management and diagnosis of ocular disorders. However, even the latest perimetric methods have shortcomings-a high cognitive demand and requiring prolonged stable fixation and feedback through a button response. Consequently, an approach using eye movements (EM)-as a natural response-has been proposed as an alternate way to evaluate the presence of VFD. This approach has given good results for computer-simulated VFD. However, its use in patients is not well documented yet. Here we use this new approach to quantify the spatiotemporal properties (STP) of EM of various patients suffering from glaucoma and neuro-ophthalmological VFD and controls. Methods: In total, 15 glaucoma patients, 37 patients with a neuro-ophthalmological disorder, and 21 controls performed a visual tracking task while their EM were being recorded. Subsequently, the STP of EM were quantified using a cross-correlogram analysis. Decision trees were used to identify the relevant STP and classify the populations. Results: We achieved a classification accuracy of 94.5% (TPR/sensitivity = 96%, TNR/specificity = 90%) between patients and controls. Individually, the algorithm achieved an accuracy of 86.3% (TPR for neuro-ophthalmology [97%], glaucoma [60%], and controls [86%]). The STP of EM were highly similar across two different control cohorts. Conclusions: In an ocular tracking task, patients with VFD due to different underlying pathology make EM with distinctive STP. These properties are interpretable based on different clinical characteristics of patients and can be used for patient classification. Translational Relevance: Our EM-based screening tool may complement existing perimetric techniques in clinical practice.


Assuntos
Glaucoma , Testes de Campo Visual , Movimentos Oculares , Glaucoma/complicações , Humanos , Transtornos da Visão/diagnóstico , Campos Visuais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA