Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Neuroradiology ; 62(3): 301-306, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31713667

RESUMO

PURPOSE: To compare the association of different measures of intracranial thrombus permeability on non-contrast computerized tomography (NCCT) and computed tomography angiography (CTA) with recanalization with or without intravenous alteplase. METHODS: Patients with anterior circulation occlusion from the INTERRSeCT study were included. Thrombus permeability was measured on non-contrast CT and CTA using the following methods: [1] automated method, mean attenuation increase on co-registered thin (< 2.5 mm) CTA/NCCT; [2] semi-automated method, maximum attenuation increase on non-registered CTA/NCCT (ΔHUmax); [3] manual method, maximum attenuation on CTA (HUmax); and [4] visual method, residual flow grade. Primary outcome was recanalization with intravenous alteplase on the revised AOL scale (2b/3). Regression models were compared using C-statistic, Akaike (AIC), and Bayesian information criterion (BIC). RESULTS: Four hundred eighty patients were included in this analysis. Statistical models using methods 2, 3, and 4 were similar in their ability to discriminate recanalizers from non-recanalizers (C-statistic 0.667, 0.683, and 0.634, respectively); method 3 had the least information loss (AIC = 483.8; BIC = 492.2). A HUmax ≥ 89 measured with method 3 provided optimal sensitivity and specificity in discriminating recanalizers from non-recanalizers [recanalization 55.4% (95%CI 46.2-64.6) when HUmax > 89 vs. 16.8% (95%CI 13.0-20.6) when HUmax ≤ 89]. In sensitivity analyses restricted to patients with co-registered CTA/NCCT (n = 88), methods 1-4 predicted recanalization similarly (C-statistic 0.641, 0.688, 0.640, 0.648, respectively) with Method 2 having the least information loss (AIC 104.8, BIC 109.8). CONCLUSION: Simple methods that measure thrombus permeability are as reliable as complex image processing methods in discriminating recanalizers from non-recanalizers.


Assuntos
Fibrinolíticos/uso terapêutico , Trombose Intracraniana/diagnóstico por imagem , Trombose Intracraniana/tratamento farmacológico , Ativador de Plasminogênio Tecidual/uso terapêutico , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Teorema de Bayes , Angiografia por Tomografia Computadorizada/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA