Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Kidney Int Rep ; 8(10): 2088-2099, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37849993

RESUMO

Introduction: The penetrance and phenotypic spectrum of autosomal dominant Alport Syndrome (ADAS), affecting 1 in 106, remains understudied. Methods: Using data from 174,418 participants in the Geisinger MyCode/DiscovEHR study, an unselected health system-based cohort with whole exome sequencing, we identified 403 participants who were heterozygous for likely pathogenic COL4A3 variants. Phenotypic data was evaluated using International Classification of Diseases (ICD) codes, laboratory data, and chart review. To evaluate the phenotypic spectrum of genetically-determined ADAS, we matched COL4A3 heterozygotes 1:5 to nonheterozygotes using propensity scores by demographics, hypertension, diabetes, and nephrolithiasis. Results: COL4A3 heterozygotes were at significantly increased risks of hematuria, decreased estimated glomerular filtration rate (eGFR), albuminuria, and kidney failure (P < 0.05 for all comparisons) but not bilateral sensorineural hearing loss (P = 0.9). Phenotypic severity was more severe for collagenous domain glycine missense variants than protein truncating variants (PTVs). For example, patients with Gly695Arg (n = 161) had markedly increased risk of dipstick hematuria (odds ratio [OR] 9.50; 95% confidence interval [CI]: 6.32, 14.28) and kidney failure (OR 7.02; 95% CI: 3.48, 14.16) whereas those with PTVs (n = 119) had moderately increased risks of dipstick hematuria (OR 1.64; 95% CI: 1.03, 2.59) and kidney failure (OR 3.44; 95% CI: 1.28, 9.22). Less than a third of patients had albuminuria screening completed, and fewer than 1 of 3 were taking inhibitors of the renin-angiotensin-aldosterone system. Conclusion: This study demonstrates a wide spectrum of phenotypic severity in ADAS due to COL4A3 with phenotypic variability by genotype. Future studies are needed to evaluate the impact of earlier diagnosis, appropriate evaluation, and treatment of ADAS.

2.
Eye (Lond) ; 37(14): 2946-2949, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37165011

RESUMO

OBJECTIVES: To compare the diabetic retinopathy (DR) severity level determined when considering only the ETDRS 7-field region versus the entire ultrawidefield (UWF) image. METHODS: In this retrospective, cross-sectional study, UWF pseudocolor images were graded on the Eyenuk image viewing, grading, and annotation platform for the severity of DR considering only the regions within the ETDRS 7-fields as well as the entire UWF image using two different protocols: 1) the simple International Classification of Diabetic Retinopathy (ICDR) scale and 2) the more complex DRCR.net Protocol AA grading scale. RESULTS: A total of 250 eyes from 157 patients were included in this analysis. Six eyes (2.4%) demonstrated a discrepancy in severity level between the ETDRS 7-field region and the entire UWF image when using the ICDR classification system. The discrepancies were due to the presence of lesions [intraretinal haemorrhage (n = 2), neovascular disease (n = 4)] in the peripheral fields which were not identified in the ETDRS 7-fields. Fourteen eyes (5.6%) had a discrepancy in severity level between the ETDRS 7-field region and the entire UWF image when using the ETDRS DRSS Protocol AA grading scale. The discrepancies were due to the presence of a higher level of disease [intraretinal haemorrhage (n = 4), neovascularization (n = 4), preretinal haemorrhage (n = 2), scatter laser scars (n = 4)] in the peripheral fields. CONCLUSION: Although considering regions outside of the ETDRS 7-fields altered the DR severity level assessment in <5% of cases in this cohort, significant and potentially vision-threatening lesions including neovascularization and preretinal haemorrhage were identified in these peripheral regions. This highlights the importance of evaluating the entire UWF region when assessing patients with diabetic retinopathy.


Assuntos
Diabetes Mellitus , Retinopatia Diabética , Humanos , Retinopatia Diabética/diagnóstico , Estudos Transversais , Estudos Retrospectivos , Olho , Hemorragia
3.
medRxiv ; 2023 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-37163122

RESUMO

Most data on Alport Syndrome (AS) due to COL4A3 are limited to families with autosomal recessive AS or severe manifestations such as focal segmental glomerulosclerosis (FSGS). Using data from 174,418 participants in the Geisinger MyCode/DiscovEHR study, an unselected health system-based cohort with whole exome sequencing, we identified 403 participants (0.2%) who were heterozygous for likely pathogenic COL4A3 variants. Phenotypic data was evaluated using International Classification of Diseases (ICD) codes, laboratory data, and chart review. To evaluate the phenotypic spectrum of genetically-determined autosomal dominant AS, we matched COL4A3 heterozygotes 1:5 to non-heterozygotes using propensity scores by demographics, hypertension, diabetes, and nephrolithiasis. COL4A3 heterozygotes were at significantly increased risks of hematuria, decreased estimated glomerular filtration rate (eGFR), albuminuria, and end-stage kidney disease (ESKD) (p<0.05 for all comparisons) but not bilateral sensorineural hearing loss (p=0.9). Phenotypic severity tended to be more severe among patients with glycine missense variants located within the collagenous domain. For example, patients with Gly695Arg (n=161) had markedly increased risk of dipstick hematuria (OR 9.47, 95% CI: 6.30, 14.22) and ESKD diagnosis (OR 7.01, 95% CI: 3.48, 14.12) whereas those with PTVs (n=119) had moderately increased risks of dipstick hematuria (OR 1.63, 95% CI: 1.03, 2.58) and ESKD diagnosis (OR 3.43, 95% CI: 1.28, 9.19). Less than a third of patients had albuminuria screening completed, and fewer than 1/3 were taking inhibitors of the renin-angiotensin-aldosterone system (RAASi). Future studies are needed to evaluate the impact of earlier diagnosis, appropriate evaluation, and treatment of ADAS.

4.
Ophthalmol Sci ; 3(1): 100228, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36345378

RESUMO

Objective: To compare general ophthalmologists, retina specialists, and the EyeArt Artificial Intelligence (AI) system to the clinical reference standard for detecting more than mild diabetic retinopathy (mtmDR). Design: Prospective, pivotal, multicenter trial conducted from April 2017 to May 2018. Participants: Participants were aged ≥ 18 years who had diabetes mellitus and underwent dilated ophthalmoscopy. A total of 521 of 893 participants met these criteria and completed the study protocol. Testing: Participants underwent 2-field fundus photography (macula centered, disc centered) for the EyeArt system, dilated ophthalmoscopy, and 4-widefield stereoscopic dilated fundus photography for reference standard grading. Main Outcome Measures: For mtmDR detection, sensitivity and specificity of EyeArt gradings of 2-field, fundus photographs and ophthalmoscopy grading versus a rigorous clinical reference standard comprising Reading Center grading of 4-widefield stereoscopic dilated fundus photographs using the ETDRS severity scale. The AI system provided automatic eye-level results regarding mtmDR. Results: Overall, 521 participants (999 eyes) at 10 centers underwent dilated ophthalmoscopy: 406 by nonretina and 115 by retina specialists. Reading Center graded 207 positive and 792 eyes negative for mtmDR. Of these 999 eyes, 26 eyes were ungradable by the EyeArt system, leaving 973 eyes with both EyeArt and Reading Center gradings. Retina specialists correctly identified 22 of 37 eyes as positive (sensitivity 59.5%) and 182 of 184 eyes as negative (specificity 98.9%) for mtmDR versus the EyeArt AI system that identified 36 of 37 as positive (sensitivity 97%) and 162 of 184 eyes as negative (specificity of 88%) for mtmDR. General ophthalmologists correctly identified 35 of 170 eyes as positive (sensitivity 20.6%) and 607 of 608 eyes as negative (specificity 99.8%) for mtmDR compared with the EyeArt AI system that identified 164 of 170 as positive (sensitivity 96.5%) and 525 of 608 eyes as negative (specificity 86%) for mtmDR. Conclusions: The AI system had a higher sensitivity for detecting mtmDR than either general ophthalmologists or retina specialists compared with the clinical reference standard. It can potentially serve as a low-cost point-of-care diabetic retinopathy detection tool and help address the diabetic eye screening burden.

5.
Curr Hypertens Rep ; 24(9): 353-359, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35666406

RESUMO

PURPOSE OF REVIEW: To review the clinical characteristics of paroxysmal hypertension (pseudopheochromocytoma), its previously unsuspected cause, and effective treatment approaches. RECENT FINDINGS: Patients with paroxysmal hypertension experience recurrent, sudden, unprovoked, symptomatic, and severe elevations of blood pressure that occur independently of current stress or perceived emotional distress. Recent findings point to a previously unsuspected psychosomatic etiology, linked in most to a past history of abuse, trauma, or prolonged severe stress, often with repression of pertinent emotions, or to a repressive coping style. Consistent with this understanding, treatment with an antidepressant is thus far the only pharmacologic intervention demonstrated to be effective in preventing recurrent paroxysms, and is effective in most patients. Other treatment approaches are discussed, including medications to acutely lower blood pressure during paroxysms, and, in some cases, the possibility of emotional healing.  Recent findings indicate that paroxysmal hypertension is a psychosomatic disorder frequently linked to a past history of trauma or prolonged severe stress, usually with longstanding repression of pertinent emotions. Data strongly encourage treatment with an antidepressant in patients with recurrent or severe paroxysms. Further studies are needed.


Assuntos
Neoplasias das Glândulas Suprarrenais , Hipertensão , Feocromocitoma , Antidepressivos/uso terapêutico , Pressão Sanguínea , Humanos , Hipertensão/tratamento farmacológico , Hipertensão/etiologia
6.
JAMA Netw Open ; 4(11): e2134254, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34779843

RESUMO

Importance: Diabetic retinopathy (DR) is a leading cause of blindness in adults worldwide. Early detection and intervention can prevent blindness; however, many patients do not receive their recommended annual diabetic eye examinations, primarily owing to limited access. Objective: To evaluate the safety and accuracy of an artificial intelligence (AI) system (the EyeArt Automated DR Detection System, version 2.1.0) in detecting both more-than-mild diabetic retinopathy (mtmDR) and vision-threatening diabetic retinopathy (vtDR). Design, Setting, and Participants: A prospective multicenter cross-sectional diagnostic study was preregistered (NCT03112005) and conducted from April 17, 2017, to May 30, 2018. A total of 942 individuals aged 18 years or older who had diabetes gave consent to participate at 15 primary care and eye care facilities. Data analysis was performed from February 14 to July 10, 2019. Interventions: Retinal imaging for the autonomous AI system and Early Treatment Diabetic Retinopathy Study (ETDRS) reference standard determination. Main Outcomes and Measures: Primary outcome measures included the sensitivity and specificity of the AI system in identifying participants' eyes with mtmDR and/or vtDR by 2-field undilated fundus photography vs a rigorous clinical reference standard comprising reading center grading of 4 wide-field dilated images using the ETDRS severity scale. Secondary outcome measures included the evaluation of imageability, dilated-if-needed analysis, enrichment correction analysis, worst-case imputation, and safety outcomes. Results: Of 942 consenting individuals, 893 patients (1786 eyes) met the inclusion criteria and completed the study protocol. The population included 449 men (50.3%). Mean (SD) participant age was 53.9 (15.2) years (median, 56; range, 18-88 years), 655 were White (73.3%), and 206 had type 1 diabetes (23.1%). Sensitivity and specificity of the AI system were high in detecting mtmDR (sensitivity: 95.5%; 95% CI, 92.4%-98.5% and specificity: 85.0%; 95% CI, 82.6%-87.4%) and vtDR (sensitivity: 95.1%; 95% CI, 90.1%-100% and specificity: 89.0%; 95% CI, 87.0%-91.1%) without dilation. Imageability was high without dilation, with the AI system able to grade 87.4% (95% CI, 85.2%-89.6%) of the eyes with reading center grades. When eyes with ungradable results were dilated per the protocol, the imageability improved to 97.4% (95% CI, 96.4%-98.5%), with the sensitivity and specificity being similar. After correcting for enrichment, the mtmDR specificity increased to 87.8% (95% CI, 86.3%-89.5%) and the sensitivity remained similar; for vtDR, both sensitivity (97.0%; 95% CI, 91.2%-100%) and specificity (90.1%; 95% CI, 89.4%-91.5%) improved. Conclusions and Relevance: This prospective multicenter cross-sectional diagnostic study noted safety and accuracy with use of the EyeArt Automated DR Detection System in detecting both mtmDR and, for the first time, vtDR, without physician assistance. These findings suggest that improved access to accurate, reliable diabetic eye examinations may increase adherence to recommended annual screenings and allow for accelerated referral of patients identified as having vtDR.


Assuntos
Inteligência Artificial/estatística & dados numéricos , Retinopatia Diabética/diagnóstico , Encaminhamento e Consulta/estatística & dados numéricos , Transtornos da Visão/diagnóstico , Seleção Visual/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Retinopatia Diabética/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Padrões de Referência , Sensibilidade e Especificidade , Transtornos da Visão/etiologia , Seleção Visual/normas , Adulto Jovem
7.
Ophthalmol Retina ; 5(1): 71-77, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32562885

RESUMO

PURPOSE: Retinal screening examinations can prevent vision loss resulting from diabetes but are costly and highly underused. We hypothesized that artificial intelligence-assisted nonmydriatic point-of-care screening administered during primary care visits would increase the adherence to recommendations for follow-up eye care in patients with diabetes. DESIGN: Prospective cohort study. PARTICIPANTS: Adults 18 years of age or older with a clinical diagnosis of diabetes being cared for in a metropolitan primary care practice for low-income patients. METHODS: All participants underwent nonmydriatic fundus photography followed by automated retinal image analysis with human supervision. Patients with positive or inconclusive screening results were referred for comprehensive ophthalmic evaluation. Adherence to referral recommendations was recorded and compared with the historical adherence rate from the same clinic. MAIN OUTCOME MEASURE: Rate of adherence to eye screening recommendations. RESULTS: By automated screening, 8.3% of the 180 study participants had referable diabetic eye disease, 13.3% had vision-threatening disease, and 29.4% showed inconclusive results. The remaining 48.9% showed negative screening results, confirmed by human overread, and were not referred for follow-up ophthalmic evaluation. Overall, the automated platform showed a sensitivity of 100% (confidence interval, 92.3%-100%) in detecting an abnormal screening results, whereas its specificity was 65.7% (confidence interval, 57.0%-73.7%). Among patients referred for follow-up ophthalmic evaluation, the adherence rate was 55.4% at 1 year compared with the historical adherence rate of 18.7% (P < 0.0001, Fisher exact test). CONCLUSIONS: Implementation of an automated diabetic retinopathy screening system in a primary care clinic serving a low-income metropolitan patient population improved adherence to follow-up eye care recommendations while reducing referrals for patients with low-risk features.


Assuntos
Instituições de Assistência Ambulatorial , Inteligência Artificial , Retinopatia Diabética/diagnóstico , Processamento de Imagem Assistida por Computador/métodos , Programas de Rastreamento/métodos , Atenção Primária à Saúde/métodos , Retina/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
8.
Eye (Lond) ; 35(1): 334-342, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32341536

RESUMO

PURPOSE: The aim of this study is to investigate the efficacy of a mobile platform that combines smartphone-based retinal imaging with automated grading for determining the presence of referral-warranted diabetic retinopathy (RWDR). METHODS: A smartphone-based camera (RetinaScope) was used by non-ophthalmic personnel to image the retina of patients with diabetes. Images were analyzed with the Eyenuk EyeArt® system, which generated referral recommendations based on presence of diabetic retinopathy (DR) and/or markers for clinically significant macular oedema. Images were independently evaluated by two masked readers and categorized as refer/no refer. The accuracies of the graders and automated interpretation were determined by comparing results to gold standard clinical diagnoses. RESULTS: A total of 119 eyes from 69 patients were included. RWDR was present in 88 eyes (73.9%) and in 54 patients (78.3%). At the patient-level, automated interpretation had a sensitivity of 87.0% and specificity of 78.6%; grader 1 had a sensitivity of 96.3% and specificity of 42.9%; grader 2 had a sensitivity of 92.5% and specificity of 50.0%. At the eye-level, automated interpretation had a sensitivity of 77.8% and specificity of 71.5%; grader 1 had a sensitivity of 94.0% and specificity of 52.2%; grader 2 had a sensitivity of 89.5% and specificity of 66.9%. DISCUSSION: Retinal photography with RetinaScope combined with automated interpretation by EyeArt achieved a lower sensitivity but higher specificity than trained expert graders. Feasibility testing was performed using non-ophthalmic personnel in a retina clinic with high disease burden. Additional studies are needed to assess efficacy of screening diabetic patients from general population.


Assuntos
Diabetes Mellitus , Retinopatia Diabética , Edema Macular , Retinopatia Diabética/diagnóstico , Humanos , Fotografação , Retina/diagnóstico por imagem , Sensibilidade e Especificidade , Smartphone
9.
Diabetes Technol Ther ; 21(11): 635-643, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31335200

RESUMO

Background: Current manual diabetic retinopathy (DR) screening using eye care experts cannot scale to screen the growing population of diabetes patients who are at risk for vision loss. EyeArt system is an automated, cloud-based artificial intelligence (AI) eye screening technology designed to easily detect referral-warranted DR immediately through automated analysis of patient's retinal images. Methods: This retrospective study assessed the diagnostic efficacy of the EyeArt system v2.0 analyzing 850,908 fundus images from 101,710 consecutive patient visits, collected from 404 primary care clinics. Presence or absence of referral-warranted DR (more than mild nonproliferative DR [NPDR]) was automatically detected by the EyeArt system for each patient encounter, and its performance was compared against a clinical reference standard of quality-assured grading by rigorously trained certified ophthalmologists and optometrists. Results: Of the 101,710 visits, 75.7% were nonreferable, 19.3% were referable to an eye care specialist, and in 5.0%, the DR level was unknown as per the clinical reference standard. EyeArt screening had 91.3% (95% confidence interval [CI]: 90.9-91.7) sensitivity and 91.1% (95% CI: 90.9-91.3) specificity. For 5446 encounters with potentially treatable DR (more than moderate NPDR and/or diabetic macular edema), the system provided a positive "refer" output to 5363 encounters achieving sensitivity of 98.5%. Conclusions: This study captures variations in real-world clinical practice and shows that an AI DR screening system can be safe and effective in the real world. This study demonstrates the value of this easy-to-use, automated tool for endocrinologists, diabetologists, and general practitioners to address the growing need for DR screening and monitoring.


Assuntos
Retinopatia Diabética/diagnóstico , Interpretação de Imagem Assistida por Computador , Edema Macular/diagnóstico , Programas de Rastreamento , Oftalmologia/tendências , Inteligência Artificial , Retinopatia Diabética/fisiopatologia , Humanos , Edema Macular/classificação , Pessoa de Meia-Idade , Variações Dependentes do Observador , Padrões de Referência , Estudos Retrospectivos
10.
Acta Ophthalmol ; 96(2): e168-e173, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28926199

RESUMO

PURPOSE: We examined the sensitivity and specificity of an automated algorithm for detecting referral-warranted diabetic retinopathy (DR) on Optos ultrawidefield (UWF) pseudocolour images. METHODS: Patients with diabetes were recruited for UWF imaging. A total of 383 subjects (754 eyes) were enrolled. Nonproliferative DR graded to be moderate or higher on the 5-level International Clinical Diabetic Retinopathy (ICDR) severity scale was considered as grounds for referral. The software automatically detected DR lesions using the previously trained classifiers and classified each image in the test set as referral-warranted or not warranted. Sensitivity, specificity and the area under the receiver operating curve (AUROC) of the algorithm were computed. RESULTS: The automated algorithm achieved a 91.7%/90.3% sensitivity (95% CI 90.1-93.9/80.4-89.4) with a 50.0%/53.6% specificity (95% CI 31.7-72.8/36.5-71.4) for detecting referral-warranted retinopathy at the patient/eye levels, respectively; the AUROC was 0.873/0.851 (95% CI 0.819-0.922/0.804-0.894). CONCLUSION: Diabetic retinopathy (DR) lesions were detected from Optos pseudocolour UWF images using an automated algorithm. Images were classified as referral-warranted DR with a high degree of sensitivity and moderate specificity. Automated analysis of UWF images could be of value in DR screening programmes and could allow for more complete and accurate disease staging.


Assuntos
Algoritmos , Retinopatia Diabética/diagnóstico , Técnicas de Diagnóstico Oftalmológico , Processamento de Imagem Assistida por Computador/métodos , Adulto , Idoso , Área Sob a Curva , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fotografação/métodos , Curva ROC , Sensibilidade e Especificidade , Software
11.
J Diabetes Sci Technol ; 10(2): 254-61, 2016 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-26888972

RESUMO

BACKGROUND: Diabetic retinopathy (DR)-a common complication of diabetes-is the leading cause of vision loss among the working-age population in the western world. DR is largely asymptomatic, but if detected at early stages the progression to vision loss can be significantly slowed. With the increasing diabetic population there is an urgent need for automated DR screening and monitoring. To address this growing need, in this article we discuss an automated DR screening tool and extend it for automated estimation of microaneurysm (MA) turnover, a potential biomarker for DR risk. METHODS: The DR screening tool automatically analyzes color retinal fundus images from a patient encounter for the various DR pathologies and collates the information from all the images belonging to a patient encounter to generate a patient-level screening recommendation. The MA turnover estimation tool aligns retinal images from multiple encounters of a patient, localizes MAs, and performs MA dynamics analysis to evaluate new, persistent, and disappeared lesion maps and estimate MA turnover rates. RESULTS: The DR screening tool achieves 90% sensitivity at 63.2% specificity on a data set of 40 542 images from 5084 patient encounters obtained from the EyePACS telescreening system. On a subset of 7 longitudinal pairs the MA turnover estimation tool identifies new and disappeared MAs with 100% sensitivity and average false positives of 0.43 and 1.6 respectively. CONCLUSIONS: The presented automated tools have the potential to address the growing need for DR screening and monitoring, thereby saving vision of millions of diabetic patients worldwide.


Assuntos
Retinopatia Diabética/diagnóstico , Técnicas de Diagnóstico Oftalmológico , Adulto , Idoso , Algoritmos , Automação Laboratorial , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Programas de Rastreamento/métodos , Sensibilidade e Especificidade
12.
IEEE Trans Image Process ; 13(12): 1627-39, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15575157

RESUMO

Information-theoretic analyses for data hiding prescribe embedding the hidden data in the choice of quantizer for the host data. In this paper, we propose practical realizations of this prescription for data hiding in images, with a view to hiding large volumes of data with low perceptual degradation. The hidden data can be recovered reliably under attacks, such as compression and limited amounts of image tampering and image resizing. The three main findings are as follows. 1) In order to limit perceivable distortion while hiding large amounts of data, hiding schemes must use image-adaptive criteria in addition to statistical criteria based on information theory. 2) The use of local criteria to choose where to hide data can potentially cause desynchronization of the encoder and decoder. This synchronization problem is solved by the use of powerful, but simple-to-implement, erasures and errors correcting codes, which also provide robustness against a variety of attacks. 3) For simplicity, scalar quantization-based hiding is employed, even though information-theoretic guidelines prescribe vector quantization-based methods. However, an information-theoretic analysis for an idealized model is provided to show that scalar quantization-based hiding incurs approximately only a 2-dB penalty in terms of resilience to attack.


Assuntos
Algoritmos , Gráficos por Computador , Segurança Computacional , Interpretação de Imagem Assistida por Computador/métodos , Armazenamento e Recuperação da Informação/métodos , Reconhecimento Automatizado de Padrão/métodos , Processamento de Sinais Assistido por Computador , Retroalimentação , Hipermídia , Patentes como Assunto , Rotulagem de Produtos/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA