Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Mech Behav Biomed Mater ; 155: 106572, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38754153

RESUMO

The personalisation of finite element models is an important problem in the biomechanical fields where subject-specific analyses are fundamental, particularly in studying soft tissue mechanics. The personalisation includes the choice of the constitutive law of the model's material, as well as the choice of the material parameters. In vivo identification of the material properties of soft tissues is challenging considering the complex behaviour of soft tissues that are, among other things, non-linear hyperelastic and heterogeneous. Hybrid experimental-numerical methods combining in vivo indentations and inverse finite element analyses are common to identify these material parameters. Yet, the uniqueness and the uncertainty of the multi-material hyperelastic model have not been evaluated. This study presents a sensitivity analysis performed on synthetic indentation data to investigate the identification uncertainties of the material parameters in a bi-material thigh phantom. Synthetic numerical data, used to replace experimental measurements, considered several measurement modalities: indenter force and displacement, stereo-camera 3D digital image correlation of the indented surface, and ultrasound B-mode images. A finite element model of the indentation was designed with either Ogden-Moerman or Mooney-Rivlin constitutive laws for both materials. The parameters' identifiability (i.e. the possibility of converging to a unique parameter set within an acceptable margin of error) was assessed with various cost functions formulated using the different synthetic data sets. The results underline the need for multiple experimental modalities to reduce the uncertainty of the identified parameters. Additionally, the experimental error can impede the identification of a unique parameter set, and the cost function depends on the constitutive law. This study highlights the need for sensitivity analyses before the design of the experimental protocol. Such studies can also be used to define the acceptable range of errors in the experimental measurement. Eventually, the impact of the evaluated uncertainty of the identified parameters should be further investigated according to the purpose of the finite element modelling.


Assuntos
Análise de Elementos Finitos , Teste de Materiais , Fenômenos Biomecânicos , Fenômenos Mecânicos , Testes Mecânicos , Elasticidade
2.
J Neuroeng Rehabil ; 21(1): 67, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38689255

RESUMO

BACKGROUND: Foot and ankle unloading is essential in various clinical contexts, including ulcers, tendon ruptures, and fractures. Choosing the right assistive device is crucial for functionality and recovery. Yet, research on the impact of devices beyond crutches, particularly ankle-foot orthoses (AFOs) designed to unload the ankle and foot, is limited. This study investigates the effects of three types of devices-forearm crutches, knee crutch, and AFO-on biomechanical, metabolic, and subjective parameters during walking with unilateral ankle-foot unloading. METHODS: Twenty healthy participants walked at a self-selected speed in four conditions: unassisted able-bodied gait, and using three unloading devices, namely forearm crutches, iWalk knee crutch, and ZeroG AFO. Comprehensive measurements, including motion capture, force plates, and metabolic system, were used to assess various spatiotemporal, kinematic, kinetic, and metabolic parameters. Additionally, participants provided subjective feedback through questionnaires. The conditions were compared using a within-subject crossover study design with repeated measures ANOVA. RESULTS: Significant differences were found between the three devices and able-bodied gait. Among the devices, ZeroG exhibited significantly faster walking speed and lower metabolic cost. For the weight-bearing leg, ZeroG exhibited the shortest stance phase, lowest braking forces, and hip and knee angles most similar to normal gait. However, ankle plantarflexion after push-off using ZeroG was most different from normal gait. IWalk and crutches caused significantly larger center-of-mass mediolateral and vertical fluctuations, respectively. Participants rated the ZeroG as the most stable, but more participants complained it caused excessive pressure and pain. Crutches were rated with the highest perceived exertion and lowest comfort, whereas no significant differences between ZeroG and iWalk were found for these parameters. CONCLUSIONS: Significant differences among the devices were identified across all measurements, aligning with previous studies for crutches and iWalk. ZeroG demonstrated favorable performance in most aspects, highlighting the potential of AFOs in enhancing gait rehabilitation when unloading is necessary. However, poor comfort and atypical sound-side ankle kinematics were evident with ZeroG. These findings can assist clinicians in making educated decisions about prescribing ankle-foot unloading devices and guide the design of improved devices that overcome the limitations of existing solutions.


Assuntos
Tornozelo , , Caminhada , Humanos , Fenômenos Biomecânicos , Masculino , Caminhada/fisiologia , Feminino , Adulto , Tornozelo/fisiologia , Pé/fisiologia , Órtoses do Pé , Tecnologia Assistiva , Adulto Jovem , Muletas , Estudos Cross-Over , Marcha/fisiologia
3.
J Mech Behav Biomed Mater ; 140: 105708, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36801779

RESUMO

Reliable identification of soft tissue material parameters is frequently required in a variety of applications, particularly for biomechanical simulations using finite element analysis (FEA). However, determining representative constitutive laws and material parameters is challenging and often comprises a bottleneck that hinders the successful implementation of FEA. Soft tissues exhibit a nonlinear response and are commonly modeled using hyperelastic constitutive laws. In-vivo material parameter identification, for which standard mechanical tests (e.g., uniaxial tension and compression) are inapplicable, is commonly achieved using finite macro-indentation test. Due to the lack of analytical solutions, the parameters are commonly identified using inverse FEA (iFEA), in which simulated results and experimental data are iteratively compared. However, determining what data must be collected to accurately identify a unique parameter set remains unclear. This work investigates the sensitivities of two types of measurements: indentation force-depth data (e.g., measured using an instrumented indenter) and full-field surface displacements (e.g., using digital image correlation). To eliminate model fidelity and measurement-related errors, we employed an axisymmetric indentation FE model to produce synthetic data for four 2-parameter hyperelastic constitutive laws: compressible Neo-Hookean, and nearly incompressible Mooney-Rivlin, Ogden, and Ogden-Moerman models. For each constitutive law, we computed the objective functions representing the discrepancies in the reaction force, the surface displacement, and their combination, and visualized them for hundreds of parameter sets, spanning a representative range as found in the literature for the bulk soft tissue complex in human lower limbs. Moreover, we quantified three identifiability metrics, which provided insights into the uniqueness (or lack thereof) and the sensitivities. This approach provides a clear and systematic evaluation of the parameter identifiability, which is independent of the selection of the optimization algorithm and initial guesses required in iFEA. Our analysis indicated that the indenter's force-depth data, despite being commonly used for parameter identification, was insufficient for reliably and accurately identifying both parameters for all the investigated material models and that the surface displacement data improved the parameter identifiability in all cases, although the Mooney-Rivlin parameters remained poorly identifiable. Informed by the results, we then discuss several identification strategies for each constitutive model. Finally, we openly provide the codes used in this study, to allow others to further investigate the indentation problem according to their specifications (e.g., by modifying the geometries, dimensions, mesh, material models, boundary conditions, contact parameters, or objective functions).


Assuntos
Extremidade Inferior , Fenômenos Mecânicos , Humanos , Análise de Elementos Finitos , Algoritmos , Elasticidade , Modelos Biológicos , Estresse Mecânico , Fenômenos Biomecânicos
4.
Artigo em Inglês | MEDLINE | ID: mdl-33095704

RESUMO

This research presents the design and preliminary evaluation of an electromyographically (EMG) controlled 2-degree-of-freedom (DOF) ankle-foot prosthesis designed to enhance rock climbing ability in persons with transtibial amputation. The prosthesis comprises motorized ankle and subtalar joints, and is capable of emulating some key biomechanical behaviors exhibited by the ankle-foot complex during rock climbing maneuvers. The free space motion of the device is volitionally controlled via input from EMG surface electrodes embedded in a custom silicone liner worn on the residual limb. The device range of motion is 0.29 radians of each dorsiflexion and plantar flexion, and 0.39 radians each of inversion and eversion. Preliminary evaluation of the device was conducted, validating the system mass of 1292 grams, build height of 250 mm, joint velocity of 2.18 radians/second, settling time of 120 milliseconds, and steady state error of 0.008 radians. Clinical evaluation of the device was performed during a preliminary study with one subject with transtibial amputation. Joint angles of the ankle-foot, knee, and hip were measured during rock climbing with the robotic prosthesis and with a traditional passive prosthesis. We found that the robotic prosthesis increases the range of achieved ankle and subtalar positions compared to a standard passive prosthesis. In addition, maximum knee flexion and hip flexion angles are decreased while climbing with the robotic prosthesis. These results suggest that a lightweight, actuated, 2-DOF EMG-controlled robotic ankle-foot prosthesis can improve ankle and subtalar range of motion and climbing biomechanical function.


Assuntos
Tornozelo , Membros Artificiais , Articulação do Tornozelo , Fenômenos Biomecânicos , Humanos , Desenho de Prótese , Amplitude de Movimento Articular
5.
Nat Biomed Eng ; 4(10): 954-972, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-33093670

RESUMO

Devices that facilitate nonverbal communication typically require high computational loads or have rigid and bulky form factors that are unsuitable for use on the face or on other curvilinear body surfaces. Here, we report the design and pilot testing of an integrated system for decoding facial strains and for predicting facial kinematics. The system consists of mass-manufacturable, conformable piezoelectric thin films for strain mapping; multiphysics modelling for analysing the nonlinear mechanical interactions between the conformable device and the epidermis; and three-dimensional digital image correlation for reconstructing soft-tissue surfaces under dynamic deformations as well as for informing device design and placement. In healthy individuals and in patients with amyotrophic lateral sclerosis, we show that the piezoelectric thin films, coupled with algorithms for the real-time detection and classification of distinct skin-deformation signatures, enable the reliable decoding of facial movements. The integrated system could be adapted for use in clinical settings as a nonverbal communication technology or for use in the monitoring of neuromuscular conditions.


Assuntos
Algoritmos , Face , Monitorização Fisiológica/instrumentação , Pele/patologia , Esclerose Lateral Amiotrófica/fisiopatologia , Dimetilpolisiloxanos , Módulo de Elasticidade , Desenho de Equipamento , Humanos , Modelos Biológicos , Monitorização Fisiológica/métodos , Reprodutibilidade dos Testes , Sorriso
6.
IEEE Trans Biomed Eng ; 66(10): 2740-2752, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-30676943

RESUMO

Effective prosthetic socket design following lower limb amputation depends upon the accurate characterization of the shape of the residual limb as well as its volume and shape fluctuations. OBJECTIVE: This study proposes a novel framework for the measurement and analysis of residual limb shape and deformation, using a high-resolution and low-cost system. METHODS: A multi-camera system was designed to capture sets of simultaneous images of the entire residuum surface. The images were analyzed using a specially developed open-source three-dimensional digital image correlation (3D-DIC) toolbox, to obtain the accurate time-varying shapes as well as the full-field deformation and strain maps on the residuum skin surface. Measurements on a transtibial amputee residuum were obtained during knee flexions, muscle contractions, and swelling upon socket removal. RESULTS: It was demonstrated that 3D-DIC can be employed to quantify with high resolution time-varying residuum shapes, deformations, and strains. Additionally, the enclosed volumes and cross-sectional areas were computed and analyzed. CONCLUSION: This novel low-cost framework provides a promising solution for the in vivo evaluation of residuum shapes and strains, as well as has the potential for characterizing the mechanical properties of the underlying soft tissues. SIGNIFICANCE: These data may be used to inform data-driven computational algorithms for the design of prosthetic sockets, as well as of other wearable technologies mechanically interfacing with the skin.


Assuntos
Algoritmos , Cotos de Amputação/anatomia & histologia , Cotos de Amputação/diagnóstico por imagem , Membros Artificiais , Imageamento Tridimensional/métodos , Desenho de Prótese/métodos , Desenho de Equipamento , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional/instrumentação , Perna (Membro) , Impressão Tridimensional
7.
Ann Biomed Eng ; 45(8): 1963-1973, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28451990

RESUMO

Optoelectronic plethysmography (OEP) is a noninvasive method for assessing lung volume variations and the contributions of different anatomical compartments of the chest wall (CW) through measurements of the motion of markers attached to the CW surface. The present study proposes a new method for analyzing the local CW kinematics from OEP measurements based on the kinematics of triangular Cosserat point elements (TCPEs). 52 reflective markers were placed on the anterior CW to create a mesh of 78 triangles according to an anatomical model. Each triangle was characterized by a TCPE and its kinematics was described using four time-variant scalar TCPE parameters. The total CW volume ([Formula: see text]) and the contributions of its six compartments were also estimated, using the same markers. The method was evaluated using measurements of ten healthy subjects, nine patients with Pompe disease, and ten patients with Duchenne muscular dystrophy (DMD), during spontaneous breathing (SB) and vital capacity maneuvers (VC) in the supine position. TCPE parameters and compartmental volumes were compared with [Formula: see text] by computing the phase angles [Formula: see text] (for SB) and the correlation r (for VC) between them. Analysis of [Formula: see text] and r of the outward translation parameter [Formula: see text] of each TCPE revealed that for healthy subjects it provided similar results to those obtained by compartmental volumes, whereas for the neuromuscular patients the TCPE method was capable of detecting local asynchronous and paradoxical movements also in cases where they were undistinguished by volumes. Therefore, the TCPE approach provides additional information to OEP that may enhance its clinical evaluation capabilities.


Assuntos
Medidas de Volume Pulmonar/métodos , Modelos Biológicos , Doenças Neuromusculares/fisiopatologia , Fotopletismografia/métodos , Mecânica Respiratória , Parede Torácica/fisiopatologia , Volume de Ventilação Pulmonar , Adolescente , Adulto , Idoso , Simulação por Computador , Feminino , Análise de Elementos Finitos , Doença de Depósito de Glicogênio Tipo II , Humanos , Masculino , Pessoa de Meia-Idade , Doenças Neuromusculares/diagnóstico , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
8.
J Biomech ; 62: 110-116, 2017 09 06.
Artigo em Inglês | MEDLINE | ID: mdl-28256246

RESUMO

The aim of this study was to analyze the accuracy of bone pose estimation based on sub-clusters of three skin-markers characterized by triangular Cosserat point elements (TCPEs) and to evaluate the capability of four instantaneous physical parameters, which can be measured non-invasively in vivo, to identify the most accurate TCPEs. Moreover, TCPE pose estimations were compared with the estimations of two least squares minimization methods applied to the cluster of all markers, using rigid body (RBLS) and homogeneous deformation (HDLS) assumptions. Analysis was performed on previously collected in vivo treadmill gait data composed of simultaneous measurements of the gold-standard bone pose by bi-plane fluoroscopy tracking the subjects' knee prosthesis and a stereophotogrammetric system tracking skin-markers affected by soft tissue artifact. Femur orientation and position errors estimated from skin-marker clusters were computed for 18 subjects using clusters of up to 35 markers. Results based on gold-standard data revealed that instantaneous subsets of TCPEs exist which estimate the femur pose with reasonable accuracy (median root mean square error during stance/swing: 1.4/2.8deg for orientation, 1.5/4.2mm for position). A non-invasive and instantaneous criteria to select accurate TCPEs for pose estimation (4.8/7.3deg, 5.8/12.3mm), was compared with RBLS (4.3/6.6deg, 6.9/16.6mm) and HDLS (4.6/7.6deg, 6.7/12.5mm). Accounting for homogeneous deformation, using HDLS or selected TCPEs, yielded more accurate position estimations than RBLS method, which, conversely, yielded more accurate orientation estimations. Further investigation is required to devise effective criteria for cluster selection that could represent a significant improvement in bone pose estimation accuracy.


Assuntos
Fêmur/fisiologia , Marcha/fisiologia , Prótese do Joelho , Idoso , Artefatos , Fenômenos Biomecânicos , Feminino , Fluoroscopia/métodos , Humanos , Análise dos Mínimos Quadrados , Masculino , Pessoa de Meia-Idade , Fotogrametria/métodos
9.
Ann Biomed Eng ; 44(4): 1181-90, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26194039

RESUMO

Accurate estimation of the position and orientation (pose) of a bone from a cluster of skin markers is limited mostly by the relative motion between the bone and the markers, which is known as the soft tissue artifact (STA). This work presents a method, based on continuum mechanics, to describe the kinematics of a cluster affected by STA. The cluster is characterized by triangular cosserat point elements (TCPEs) defined by all combinations of three markers. The effects of the STA on the TCPEs are quantified using three parameters describing the strain in each TCPE and the relative rotation and translation between TCPEs. The method was evaluated using previously collected ex vivo kinematic data. Femur pose was estimated from 12 skin markers on the thigh, while its reference pose was measured using bone pins. Analysis revealed that instantaneous subsets of TCPEs exist which estimate bone position and orientation more accurately than the Procrustes Superimposition applied to the cluster of all markers. It has been shown that some of these parameters correlate well with femur pose errors, which suggests that they can be used to select, at each instant, subsets of TCPEs leading an improved estimation of the underlying bone pose.


Assuntos
Fêmur/fisiologia , Artefatos , Fenômenos Biomecânicos , Humanos , Extremidade Inferior/fisiologia , Movimento , Fotogrametria , Rotação , Pele
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA